Search PubMed⌕ Search

Biomedical subjects

Stephen L Keeling

Publications and source records attributed to Stephen L Keeling.

2 recordsLinked to original sources

Three-dimensional models of individual cardiac histoanatomy: tools and challenges.

There is a need for, and utility in, the acquisition of data sets of cardiac histoanatomy, with the vision of reconstructing individual hearts on the basis of noninvasive imaging, such as MRI, enriched by reference to detailed atlases of serial histology obtained from representative samples. These data sets would be useful not only as a repository of knowledge regarding the specifics of cardiac histoanatomy, but could form the basis for generation of individualized high-resolution cardiac structure-function models. The current article presents a step in this general direction: it illustrates how whole-heart noninvasive imaging can be combined with whole-heart histology in an approach to achieve automated construction of histoanatomically detailed models of cardiac 3D structure and function at hitherto unprecedented resolution and accuracy (based on 26.4 x 26.4 x 24.4 microm MRI voxel size, and enriched by histological detail). It provides an overview of the tools used in this quest and outlines challenges posed by the approach in the light of applications that may benefit from the availability of such data and tools.

Animals↗

Diffusion tensor imaging using single-shot SENSE-EPI.

SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind of image distortion. Whether DTI is feasible in combination with SENSE has not yet been explored, and is the focus of this study. Using a SENSE-reduction factor of 2, DTI scans in eight healthy volunteers were carried out with regular- and high-resolution acquisition matrices. To further improve the stability of the SENSE reconstruction, a new coil-sensitivity estimation technique based on variational calculus and the principles of matrix regularization was applied. With SENSE, maps of the trace of the diffusion tensor and of fractional anisotropy (FA) had improved spatial resolution and less geometric distortion. Overall, the geometric distortions were substantially removed and a significant resolution enhancement was achieved with almost the same scan time as regular EPI. DTI was even possible without the use of quadrature body coil (QBC) reference scans. Geometry-factor-related noise enhancement was only discernible in maps generated with higher-resolution matrices. Error boundaries for residual fluctuations in SENSE reconstructions are discussed. Our results suggest that SENSE can be combined with DTI and may present an important adjunct for future neuroimaging applications of this technique.

Brain↗