Search PubMed⌕ Search

Biomedical subjects

Stephen J Dodd

Publications and source records attributed to Stephen J Dodd.

6 recordsLinked to original sources

Catheter confocal fluorescence imaging and functional magnetic resonance imaging of local and systems level recovery in the regenerating rodent sciatic nerve.

The goal of the present work was to develop minimally invasive imaging techniques to monitor local regeneration of peripheral nerves and to determine the extent of return to function of brain cortical regions associated with that nerve. The sciatic nerve crush model was applied to Sprague-Dawley rats and conventional histological staining for myelin, axons and cell architecture was carried out, as well as traditional behavioral testing, to verify that nerve regeneration was occurring. The rate of sciatic nerve regeneration was measured by determining the distance a lipophilic, fluorescence probe (DiO) would move along the nerve's membrane following a direct injection into the sciatic nerve. This movement was monitored using a catheter based, confocal fluorescence microscope. Two to five days after the crush, the dye moved 1.4 + 0.6 mm/day, as compared to a distance of 5.3 + 0.5 mm/day in the normal nerve. Between 9 and 13 days following the crush, the distance the dye moved increases to 5.5 + 0.5 mm/day, similar to the control, and by 15 days following the crush, the distance increased to 6.5 + 0.9 mm/day. Functional Magnetic Resonance Imaging (fMRI) measurements were performed on alpha-chloralose anesthetized rats to monitor the return of somatosensory cortical functions, which were activated by the stimulation of the lesioned peripheral nerve. fMRI results showed the return of cortical activation around 15 days following the crush procedure. However, the somatosensory cortical region activated by stimulating the crushed hindpaw was significantly smaller in extent than the intact hindpaw stimulation. These findings demonstrate that fluorescence imaging and fMRI can integrate local and system level correlates of nerve regeneration in a non-destructive manner, thus enabling serial imaging of individual animals.

Animals↗

Orientational dependence of intermolecular double quantum coherence (iDQC) signal from tendon tissue.

The proton signal changes as the long axis of tendon tissue is rotated with respect to the main magnetic field (B(0)). The orientational changes in the tendon signal obtained using the correlation spectroscopy revamped by asymmetric z-gradient echo detection (CRAZED) sequence, which allows the effects of intermolecular dipolar interactions to be observed, were investigated and compared with the orientational changes of the signals produced using correlation spectroscopy (COSY), spin-echo (SE), and one-pulse sequences. The intermolecular double quantum coherence (iDQC) signal obtained using the CRAZED sequence showed a variation in the signal from tendon tissue, with sharper peaks and greater relative differences between minimum and maximum signal values compared to the variations in the signal obtained from the COSY, SE, and one-pulse sequences. This result is attributed to the orientational dependence of the transverse relaxation rate of single (SQC) and double (DQH) quantum coherences R(2) and R(2,2), respectively.

Animals↗

Water in tendon: orientational analysis of the free induction decay.

The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a specimen and the external magnetic field is changed from the "magic angle" of 54.7 degrees to 0 degrees. The strength of residual dipolar interactions between water protons was estimated by orientational analysis of the signal intensity to be equal to 780 Hz. Apparent signal maxima are observed at orientations 8-13 degrees away from 54.7 degrees due to an inhomogeneous contribution to the decay. A small fraction of total water in tendon is detectable at all orientations and exhibits a shift in the precession frequency. It is hypothesized that this water fraction resides in the interconnecting gaps at the ends of collagen molecules. The gaps have a disordered environment that allows for a zero time average of dipolar interactions. Measured frequency and phase shifts are interpreted as signatures of the bulk magnetic susceptibility effect due to geometry of the cavity formed by adjacent gaps at the ends of the collagen molecules. The multiexponentiality of the FID decay is hypothesized to be due to the exchange between orientationally restricted water structured along the length of the collagen molecule and disordered water in the cavity.

Animals↗

Testing the three-pool white matter model adapted for use with T2 relaxometry.

A three-pool model was used to improve white-matter T2 relaxometry in low signal-to-noise (SNR) data. To verify the model very high SNR T2 relaxometry experiments were performed on myelinated tissue samples and three-pool fractions were consistently found. Relaxation curves based on the in vitro results were simulated with multiple SNRs and fit using the three-pool model and three less constraining nonnegative least squares-based methods. All methods performed well with noiseless data. At lower SNR values the three-pool model was superior, primarily due to the fact that the other methods often could not unambiguously calculate pool fractions.

Algorithms↗

Short planar gradient coils for MR microscopy using concentric return paths.

The aim of this work is to design a set of gradient coils with an optimal geometry for magnetic resonance microscopy studies. Designs for a three-axis gradient coil system particularly suited for studies with small radiofrequency coils are presented. The novel geometry involves a planar section with concentric return paths to keep the coil short. Reduction of the external field has been attempted by varying the positions of the return paths using a simulated annealing algorithm. A biplanar version of x- and z-directed prototype gradients was built and tested. A 2D-MR image of a grid phantom has been obtained on a 7-T MR instrument to demonstrate the theory. A three-axis set used as a surface gradient set has also been built and used to obtain high-resolution MR images.

Equipment Design↗

Temperature mapping of laser-induced hyperthermia in an ocular phantom using magnetic resonance thermography.

Laser-induced heating in an ocular phantom is measured with magnetic resonance thermography (MRT) using temperature-dependent phase changes in proton resonance frequency. The ocular phantom contains a layer of melanosomes isolated from bovine retinal pigment epithelium. The phantom is heated by the 806-nm output of a continuous wave diode laser with an irradiance of 2.4 to 21.6 W/cm2 in a beam radius of 0.8 or 2.4 mm, depending on the experiment. MRT is performed with a 2 T magnet, and a two-turn, 6-cm-diam, circular radio frequency coil. Two-dimensional temperature gradients are measured within the plane of the melanin layer, as well as normal to it, with a temperature resolution of 1 degrees C or better. The temperature gradients extending within the melanin layer are broader than those orthogonal to the layer, consistent with the higher optical absorption and consequent heating in the melanin. The temperature gradients in the phantom measured by MRT closely approximate the predictions of a classical heat diffusion model. Three-dimensional temperature maps with a spatial resolution of 0.25 mm in all directions are also made. Although the temporal resolution is limited in the prototype system (22.9 s for a single image "slice"), improvements in future implementations are likely. These results indicate that MRT has sufficient spatial and temperature resolution to monitor target tissue temperature during transpupillary thermotherapy in the human eye.

Animals↗