Search PubMed⌕ Search

Biomedical subjects

Stephan M Perren

Publications and source records attributed to Stephan M Perren.

8 recordsLinked to original sources

Surgical aspects of infection involving osteosynthesis implants: implant design and resistance to local infection.

Infection is still a major complication associated with surgery in orthopedics and traumatology. The implant design, the implant material, and the implantation technique may play essential roles in preventing infection. The goal of this paper is to discuss a series of experiments evaluating different aspects of both surgical procedures and implants. For this purpose, standardized local application of the human pathogen Staphylococcus aureus was performed in an animal model. Although these experimental results may be clinically relevant, direct extrapolation to clinical infection rates should be avoided.

Animals↗

In vivo measurement of bending stiffness in fracture healing.

BACKGROUND: Measurement of the bending stiffness a healing fracture represents a valid variable in the assessment of fracture healing. However, currently available methods typically have high measurement errors, even for mild pin loosening. Furthermore, these methods cannot provide actual values of bending stiffness, which precludes comparisons among individual fractures. Thus, even today, little information is available with regards to the fracture healing pattern with respect to actual values of bending stiffness. Our goals were, therefore: to develop a measurement device that would allow accurate and sensitive measurement of bending stiffness, even in the presence of mild pin loosening; to describe the course of healing in individual fractures; and help to evaluate whether the individual pattern of bending stiffness can be predicted at an early stage of healing. METHODS: A new measurement device has been developed to precisely measure the bending stiffness of the healing fracture by simulating four-point-bending. The system was calibrated on aluminum models and intact tibiae. The influence of pin loosening on measurement error was evaluated. The system was tested at weekly intervals in an animal experiment to determine the actual bending stiffness of the fracture. Transverse fractures were created in the right tibia of twelve sheep, and then stabilized with an external fixator. At ten weeks, bending stiffness of the tibiae were determined in a four-point-bending test device to validate the in-vivo-measurement data. RESULTS: In-vivo bending stiffness can be measured accurately and sensitive, even in the early phase of callus healing. Up to a bending stiffness of 10 Nm/degree, measurement error was below 3.4% for one pin loose, and below 29.3% for four pins loose, respectively. Measurement of stiffness data over time revealed a significant logarithmic increase between the third and seventh weeks, whereby the logarithmic rate of change among sheep was similar, but started from different levels. Comparative measurements showed that early individual changes between the third and fourth weeks can be used as a predictor of bending stiffness at seven weeks (r = 0.928) and at ten weeks (r = 0.710). CONCLUSION: Bending stiffness can be measured precisely, with less error in the case of pin loosening. Prediction of the future healing course of the individual fracture can be assessed by changes from the third to the fourth week, with differences in stiffness levels. Therefore, the initial status of the fracture seems to have a high impact on the individual healing course.

Animals↗

The effect of delayed autogenous bone grafting on the healing of diaphyseal defects in a canine model.

Bone grafting of osseous defects is often delayed to minimize the risk of infection, however, the effect of this delay on defect healing is not clear. Unilateral oblong unicortical diaphyseal femoral defects (30 x 4.5 mm) were created in 3 groups of 18 adult canines that were grafted with autogenous bone immediately, at 2 weeks, and at 6 weeks. After an 8-week healing period, paired femurs, h consisted of defect versus intact specimens, were assessed by biomechanical testing and microradiography. No differences were demonstrated biomechanically or radiographically between the healing defects with immediate versus delayed bone grafting. This study suggests that within the first 6 weeks postoperatively osseous defects can be grafted with autologous bone without adversely affecting bone graft incorporation.

Analysis of Variance↗

Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology.

The advent of 'biological internal fixation' is an important development in the surgical management of fractures. Locked nailing has demonstrated that flexible fixation without precise reduction results in reliable healing. While external fixators are mainly used today to provide temporary fixation in fractures after severe injury, the internal fixator offers flexible fixation, maintaining the advantages of the external fixator but allowing long-term treatment. The internal fixator resembles a plate but functions differently. It is based on pure splinting rather than compression. The resulting flexible stabilisation induces the formation of callus. With the use of locked threaded bolts, the application of the internal fixator foregoes the need of adaptation of the shape of the splint to that of the bone during surgery. Thus, it is possible to apply the internal fixator as a minimally invasive percutaneous osteosynthesis (MIPO). Minimal surgical trauma and flexible fixation allow prompt healing when the blood supply to bone is maintained or can be restored early. The scientific basis of the fixation and function of these new implants has been reviewed. The biomechanical aspects principally address the degree of instability which may be tolerated by fracture healing under different biological conditions. Fractures may heal spontaneously in spite of gross instability while minimal, even non-visible, instability may be deleterious for rigidly fixed small fracture gaps. The theory of strain offers an explanation for the maximum instability which will be tolerated and the minimal degree required for induction of callus formation. The biological aspects of damage to the blood supply, necrosis and temporary porosity explain the importance of avoiding extensive contact of the implant with bone. The phenomenon of bone loss and stress protection has a biological rather than a mechanical explanation. The same mechanism of necrosis-induced internal remodelling may explain the basic process of direct healing.

Animals↗