Viscoelastic shear properties of in vivo breast lesions measured by MR elastography.

Elastography is a technique to assess the viscoelastic properties of tissue by measuring an acoustic wave propagating though the object. Here, the technique is applied in the course of standard MR mammography to 15 patients with different pathologies (six breast cancer cases, six fibroadenoma cases and three mastopathy cases). Low-frequency mechanical waves are coupled longitudinally into the tissue in order to obtain sufficient wave amplitude throughout the entire breast. This leads to the presence of a substantial fraction of compressional waves, which contribute to the total displacement field. It is shown theoretically that the correct evaluation of these contributions from the compressional wave is rather difficult due to the almost incompressible nature of tissue. To overcome this problem, it is proposed to apply the curl-operator to the measured displacement field in order to completely remove contributions from the compressional wave. Results from simulations and a breast phantom demonstrate the feasibility of the technique. The in vivo results show a good separation between breast cancer and benign fibroadenoma utilizing the shear modulus. Breast cancer appears on average 2.2 (P<.001) times stiffer. All breast cancer cases showed a good delineation to the surrounding breast tissue with an average elevation of a factor of 3.3 (P< 1.4 x 10(-6)). The results as obtained for the shear viscosity do not indicate to be useful for separating benign from malignant lesions.

Acoustics↗

Assessment of elastic parameters of human skin using dynamic elastography.

Sonoelastography and transient elastography are two ultrasound-based techniques that facilitate noninvasive characterization of the viscoelastic properties of soft tissues by investigating their response to shear mechanical excitation. Young's modulus is the principle assessment parameter. Because it defines local tissue stiffness, it is of major interest for the medical imaging and cosmetic industries as it could replace subjective palpation by yielding local, quantitative information. In this paper, we describe a new high-resolution device capable of measuring local Young's modulus in very thin layers (1-5 mm) and devoted to the in vivo evaluation of the elastic properties of human skin. It uses an ultrasonic probe (50 MHz) for tracking the displacements induced by a 300 Hz shear wave generated by a ring surrounding the transducer. The displacements are measured using a conventional cross-correlation technique between successive ultrasonic back-scattered echoes. First, this noninvasive technique has been experimentally proven to be accurate for investigating elasticity in different skin-mimicking phantoms. Second, data were acquired in vivo on human forearms. As expected, Young's modulus was found to be higher in the dermis than in the hypodermis and other soft tissues.

Elasticity↗

Transient elastography in anisotropic medium: application to the measurement of slow and fast shear wave speeds in muscles.

From the measurement of a low frequency (50-150 Hz) shear wave speed, transient elastography evaluates the Young's modulus in isotropic soft tissues. In this paper, it is shown that a rod source can generate a low frequency polarized shear strain waves. Consequently this technique allows to study anisotropic medium such as muscle. The evidence of the polarization of low frequency shear strain waves is supported by both numeric simulations and experiments. The numeric simulations are based on theoretical Green's functions in isotropic and anisotropic media (hexagonal system). The experiments in vitro led on beef muscle proves the pertinent of this simple anisotropic pattern. Results in vivo on man biceps shows the existence of slow and fast shear waves as predicted by theory.

Acoustic Stimulation↗

Shear modulus imaging with 2-D transient elastography.

In previous works, we have shown that time-resolved 2-D transient elastography is a promising technique for characterizing the elasticity of soft tissues. It involves the measurement of the displacements induced by the propagation of low frequency (LF) pulsed shear waves in biological tissues. In this paper, we present a novel apparatus that contains a LF vibrating device surrounding a linear array of 128 ultrasonic transducers that performs ultrafast ultrasonic imaging (up to 10,000 frames/s) and that is able to follow in real time the propagation of a LF shear wave in the human body. The vibrating device is made of two rods, fixed to electromagnetic vibrators, that produce in the ultrasonic image area a large amplitude shear wave. The geometry has been chosen both to enhance the sensitivity and to create a quasi linear shear wave front in the imaging plane. An inversion algorithm is used to recover the shear modulus map from the spatio-temporal data, and the first experimental results obtained from tissue-equivalent materials are presented.

Algorithms↗

Shear elasticity probe for soft tissues with 1-D transient elastography.

Important tissue parameters such as elasticity can be deduced from the study of the propagation of low frequency shear waves. A new method for measuring the shear velocity in soft tissues is presented in this paper. Unlike conventional transient elastography, in which the ultrasonic transducer and the low frequency vibrator are two separated parts, the new method relies on a probe that associates the vibrator and the transducer, which is built on the axis of the vibrator. This setup is easy to use. The low frequency shear wave is driven by the transducer itself that acts as a piston while it is used in pulse echo mode to acquire ultrasonic lines. The results obtained with the new method are in good agreement with those obtained with the conventional one.

Algorithms↗