Search PubMed⌕ Search

Biomedical subjects

Stéphanie Montmerle

Publications and source records attributed to Stéphanie Montmerle.

6 recordsLinked to original sources

Effects of gravity and blood volume shifts on cardiogenic oscillations in respired gas.

During the cardiac cycle, cardiogenic oscillations of expired gas (x) concentrations (COS([x])) are generated. At the same time, there are heart-synchronous cardiogenic oscillations of airway flow (COS(flow)), where inflow occurs during systole. We hypothesized that both phenomena, although primarily generated by the heartbeat, would react differently to the cephalad blood shift caused by inflation of an anti-gravity (anti-G) suit and to changes in gravity. Twelve seated subjects performed a rebreathing-breath-holding-expiration maneuver with a gas mixture containing O2 and He at normal (1 G) and moderately increased gravity (2 G); an anti-G suit was inflated to 85 mmHg in each condition. When the anti-G suit was inflated, COS(flow) amplitude increased (P = 0.0028) at 1 G to 186% of the control value without inflation (1-G control) and at 2 G to 203% of the control value without inflation (2-G control). In contrast, the amplitude of COS of the concentration of the blood-soluble gas O2 (COS([O2/He])), an index of the differences in pulmonary perfusion between lung units, declined to 75% of the 1-G control value and to 74% of the 2-G control value (P = 0.0030). There were no significant changes in COS(flow) or COS([O2/He]) amplitudes with gravity. We conclude that the heart-synchronous mechanical agitation of the lungs, as expressed by COS(flow), is highly dependent on peripheral-to-central blood shifts. In contrast, COS([blood-soluble gas]) appears relatively independent of this mechanical agitation and seems to be determined mainly by differences in intrapulmonary perfusion.

Adaptation, Physiological↗

Cardiovascular effects of anti-G suit inflation at 1 and 2 G.

We sought to determine to which pressure a full-coverage anti-G suit needs to be inflated in order to obtain the same stroke volume during a brief exposure to twice the normal gravity (2 G) as that at 1 G without anti-G suit inflation. Nine sitting subjects were studied at normal (1 G) and during 20 s of exposure to 2 G. They wore anti-G suits, which were inflated at both G-levels to the following target pressures: 0, 70, 140 and 210 mmHg. Stroke volume was computed from cardiac output, which was measured by rebreathing. Heart rate and mean arterial pressure at heart level were recorded. Inflation to 70 mmHg compensated for the decrease in stroke volume and cardiac output caused by hypergravity. Mean arterial pressure at heart level was comparable at 1 G and at 2 G and increased gradually and similarly with inflation (P<0.001) at both gravity levels. Thus, anti-G suits act by increasing both preload and afterload but the two effects counteract each other in terms of cardiac output, so that cardiac output at 2 G is maintained at its 1 G level. This effect is reached already at 70 mmHg of inflation. Greater inflation pressure further increases mean arterial pressure at heart level and compensates for the increased difference in hydrostatic pressure between heart and head in moderate hypergravity.

Abdominal Pain↗

Residual heterogeneity of intra- and interregional pulmonary perfusion in short-term microgravity.

We hypothesized that the perfusion heterogeneity in the human, upright lung is determined by nongravitational more than gravitational factors. Twelve and six subjects were studied during two series of parabolic flights. We used cardiogenic oscillations of O(2)/SF(6) as an indirect estimate of intraregional perfusion heterogeneity (series 1) and phase IV amplitude (P(4)) as a indirect estimate of interregional perfusion heterogeneity (series 2). A rebreathing-breath holding-expiration maneuver was performed. In flight, breath holding and expiration were performed either in microgravity (0 G) or in hypergravity. Controls were performed at normal gravity (1 G). In series 1, expiration was performed at 0 G. Cardiogenic oscillations of O(2)/SF(6) were 19% lower when breath holding was performed at 0 G than when breath holding was performed at 1 G [means (SD): 1.7 (0.3) and 2.3 (0.6)% units] (P = 0.044). When breath holding was performed at 1.8 G, values did not differ from 1-G control [2.6 (0.8)% units, P = 0.15], but they were 17% larger at 1.8 G than at 1 G. In series 2, expiration was performed at 1.7 G. P(4) changed with gravity (P < 0.001). When breath holding was performed at 0 G, P(4) values were 45 (46)% of control. When breath holding was performed at 1.7 G, P(4) values were 183 (101)% of control. We conclude that more than one-half of indexes of perfusion heterogeneity at 1 G are caused by nongravitational mechanisms.

Adaptation, Physiological↗

Long-term bed rest-induced reductions in stroke volume during rest and exercise: cardiac dysfunction vs. volume depletion.

Long-term head-down-tilt bed rest (HDT) causes cardiovascular deconditioning, attributed to reflex dysfunctions, plasma volume reduction, or cardiac impairments. Our objective with the present study was to evaluate the functional importance and relative contribution of these during rest and exercise in supine and upright postures. We studied six subjects before (baseline), during [days 60 (D60) and 113 (D113)], and after [recovery days 0 (R0), 3 (R3), and 15 (R15)] 120 days of -6 degrees HDT. We determined cardiac output, stroke volume (SV), mean arterial pressure, and heart rate during rest and exercise in supine and upright postures. Cardiac output and SV decreased significantly in all four conditions, but the time courses differed for rest and exercise. Upright resting SV was decreased by 24 +/- 9% at D60 compared with baseline but had recovered already at R3. Supine exercise SV decreased more slowly (by 5 +/- 8% at D60 and by 18 +/- 4% at D113) and recovered more slowly after HDT termination. Steady-state mean arterial pressure showed no changes. Heart rate had increased by 18 +/- 4% at D60 and had recovered partially at R3. Our data indicate that long-term HDT causes both a rapid, preload-dependent reduction in SV, most evident during rest in the upright position, and a more slowly developing cardiac dysfunction, most evident during supine exercise. However, the ability to maintain blood pressure and to perform sustained low levels of dynamic exercise is not influenced by HDT.

Adaptation, Physiological↗

Physiological evaluation of a new quantitative SPECT method measuring regional ventilation and perfusion.

We have developed a new quantitative single-photon-emission computed tomography (SPECT) method that uses (113m)In-labeled albumin macroaggregates and Technegas ((99m)Tc) to estimate the distributions of regional ventilation and perfusion for the whole lung. The multiple inert-gas elimination technique (MIGET) and whole lung respiratory gas exchange were used as physiological evaluations of the SPECT method. Regional ventilation and perfusion were estimated by SPECT in nine healthy volunteers during awake, spontaneous breathing. Radiotracers were administered with subjects sitting upright, and SPECT images were acquired with subjects supine. Whole lung gas exchange of MIGET gases and arterial Po(2) and Pco(2) gases was predicted from estimates of regional ventilation and perfusion. We found a good agreement between measured and SPECT-predicted exchange of MIGET and respiratory gases. Correlations (r(2)) between SPECT-predicted and measured inert-gas excretions and retentions were 0.99. The method offers a new tool for measuring regional ventilation and perfusion in humans.

Adult↗

Lung function during and after prolonged head-down bed rest.

We determined the effects of prolonged head-down tilt bed rest (HDT) on lung mechanics and gas exchange. Six subjects were studied in supine and upright postures before (control), during [day 113 (D113)], and after (R + number of days of recovery) 120 days of HDT. Peak expiratory flow (PF) never differed between positions at any time and never differed from controls. Maximal midexpiratory flow (FEF(25-75%)) was lower in the supine than in the upright posture before HDT and was reduced in the supine posture by about 20% between baseline and D113, R + 0, and R + 3. The diffusing capacity for carbon monoxide corrected to a standardized alveolar volume (volume-corrected DL(CO)) was lower in the upright than in the supine posture and decreased in both postures by 20% between baseline and R + 0 and by 15% between baseline and R + 15. Pulmonary blood flow (Q(C)) increased from R + 0 to R + 3 by 20 (supine) and 35% (upright). As PF is mostly effort dependent, our data speak against major respiratory muscle deconditioning after 120 days of HDT. The decrease in FEF(25-75%) suggests a reduction in elastic recoil. Time courses of volume-corrected DL(CO) and Q(C) could be explained by a decrease in central blood volume during and immediately after HDT.

Adult↗