Reliability of HemoCue in patients with gastrointestinal bleeding.

OBJECTIVE: HemoCue is routinely used to manage bleeding patients, but few studies have evaluated its accuracy in this population. We compared HemoCue with laboratory determination of blood hemoglobin in patients with gastrointestinal bleeding. DESIGN AND SETTING: A prospective observational study in a 14-bed medicosurgical ICU and an emergency department in an urban general hospital. PATIENTS: 94 patients admitted to the emergency department or to the ICU for gastrointestinal bleeding. INTERVENTIONS: Blood was drawn at admission to measure laboratory hemoglobin and capillary hemoglobin was measured simultaneously by HemoCue. The unit of hospitalization and the presence or absence of impaired vital signs (tachycardia and/or hypotension and/or shock) were recorded. MEASUREMENTS AND RESULTS: The mean difference between HemoCue and hemoglobin (bias) was -0.06 g/dl and standard deviation (precision) 0.87 g/dl. (95% CI -1.8 to 1.68). Discrepancies between HemoCue and hemoglobin were greater than 1 g/dl in 21% of cases. Bias was comparable between patients admitted to the ICU and those in the emergency department. The accuracy of HemoCue was not affected by the presence of impaired vital signs or by a hemoglobin level below 9 g/dl or 7 g/dl. CONCLUSIONS: Although we demonstrated a low bias between HemoCue and blood hemoglobin determination, large HemoCue vs. hemoglobin differences may still occur, and therefore therapeutic decisions based upon capillary HemoCue alone should be very cautious.

Gastrointestinal Hemorrhage↗

Pulmonary edema induced by calcium-channel blockade for tocolysis.

Nicardipine is used in the treatment of premature labor. There are no previous reports in the anesthesia literature of serious side effects associated with this drug. We report a case of pulmonary edema induced by nicardipine therapy for tocolysis in a pregnant 27-yr-old patient admitted to our hospital for preterm labor with intact membranes at 27 wk of gestation.

Adult↗

Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system.

OBJECTIVE: To compare measurements of cardiac output using a new pulmonary artery catheter with those obtained using two "gold standard" methods: the periaortic transit time ultrasonic flow probe and the conventional pulmonary artery thermodilution. DESIGN: Prospective clinical trial. SETTING: Cardiac surgery operating room and surgical ICU in a university hospital. MATERIAL AND METHODS: In the operating room, a new pulmonary artery catheter (truCCOMS system) was inserted in eight patients. A periaortic flow probe was inserted in four of them. Measurements of cardiac output obtained with the truCCOMS catheter and with the flow probe were compared at different phases of the surgical procedure. In the intensive care unit, the cardiac output displayed by the truCCOMS monitor was compared with the value obtained after bolus injection performed subsequently. RESULTS: In the operating room (70 measurements), the coefficient of correlation between cardiac output measured by the flow probe and the truCCOMS system was r2 = 0.79, the bias was +0.11 l/min with a precision of 0.47 l/min, and limits of agreement -0.83 to +1.05 l/min. In the intensive care unit (108 measurements), the coefficient of correlation between cardiac output measured by thermodilution and the truCCOMS system was r2 = 0.56, the bias was -0.07 l/min, the precision was 0.66 l/min, and the limits of agreement were -1.39 to +1.25 l/min. CONCLUSION: The truCCOMS system is a reliable method of continuous cardiac output measurement in cardiac surgery patients.

Aorta↗