Search PubMed⌕ Search

Biomedical subjects

Spiridon V Spirou

Publications and source records attributed to Spiridon V Spirou.

3 recordsLinked to original sources

A new method of incorporating systematic uncertainties in intensity-modulated radiotherapy optimization.

Uncertainties in tumor position during intensity-modulated radiotherapy (IMRT) plan optimization are usually accounted for by adding margins to a clinical target volume (CTV), or additionally, to organs at risk (OAR). The former approach usually favors target coverage over OAR protection, whereas the latter does not account for correlation in target and OAR movement. We investigate a new approach to incorporate systematic errors in tumor and organ position. The method models a distribution of systematic errors due to setup error and organ motion with displaced replicas of volumes of interest, each representing the patient geometry for a possible systematic error, and maximizes a score function that counts the number of replicas meeting dose or biological constraints for both CTV and OAR. Dose constraints are implemented by logistic functions of Niemierko's generalized model of equivalent uniform dose (EUD). The method is applied to prostate and nasopharynx IMRT plans, in which CTV and OAR each consists of five replicas, one representing no error (the position in the planning CT) and the other four discrete systematic setup displacements in one dimension with equal probability. The resulting IMRT plans are compared with those from two other EUD-based optimizations: a standard planning target volume (PTV) approach consisting of a single replica of each OAR in the planned position and a single PTV encompassing all CTV replicas, and a PTV-PRV approach consisting of a single PTV and a single planning risk volume (PRV) for each OAR encompassing all replicas. When systematic error is present, multiple-replica optimization provides better critical organ protection while maintaining similar target coverage compared with the PTV approach, and provides better CTV-to-OAR therapeutic ratio compared with the PTV-PRV instances where there is substantial PTV-PRV overlap. The method can be used for other systematic errors due to organ motion and deformation.

Body Burden↗

CT image-guided intensity-modulated therapy for paraspinal tumors using stereotactic immobilization.

PURPOSE: To design and implement a noninvasive stereotactic immobilization technique with daily CT image-guided positioning to treat patients with paraspinal lesions accurately and to quantify the systematic and random patient setup errors occurring with this method. METHODS AND MATERIALS: A stereotactic body frame (SBF) was developed for "rigid" immobilization of paraspinal patients. The inherent accuracy of this system for stereotactic CT-guided treatment was evaluated with phantom studies. Seven patients with thoracic and lumbar spine lesions were immobilized with the SBF and positioned for 33 treatment fractions using daily CT scans. For all 7 patients, the daily setup errors, as assessed from the daily CT scans, were corrected at each treatment fraction. A retrospective analysis was also performed to assess what the impact on patient treatment would have been without the CT-based corrections (i.e., if patient setup had been performed only with the SBF). RESULTS: The average magnitude of systematic and random errors from uncorrected patient setups using the SBF was approximately 2 mm and 1.5 mm (1 SD), respectively. For fixed phantom targets, the system accuracy for the SBF localization and treatment was shown to be within 1 mm (1 SD) in any direction. Dose-volume histograms incorporating these uncertainties for an intensity-modulated radiotherapy plan for lumbar spine lesions were generated, and the effects on the dose-volume histograms were studied. CONCLUSION: We demonstrated a very accurate and precise method of patient immobilization and treatment delivery based on a noninvasive SBF and daily image guidance for paraspinal lesions. The SBF provides excellent immobilization for paraspinal targets, with setup accuracy better than 2 mm (1 SD). However, for highly conformal paraspinal treatments, uncorrected systematic and random errors of 2 mm in magnitude can result in a significantly greater (>100%) dose to the spinal cord than planned, even though the planned target coverage may not change substantially. With daily CT guidance using the SBF, we showed that the maximal spinal cord dose is ensured to be within 10-15% of the planned value.

Humans↗

Intensity-modulated radiotherapy.

Intensity-modulated radiotherapy represents a recent advancement in conformal radiotherapy. It employs specialized computer-driven technology to generate dose distributions that conform to tumor targets with extremely high precision. Treatment planning is based on inverse planning algorithms and iterative computer-driven optimization to generate treatment fields with varying intensities across the beam section. Combinations of intensity-modulated fields produce custom-tailored conformal dose distributions around the tumor, with steep dose gradients at the transition to adjacent normal tissues. Thus far, data have demonstrated improved precision of tumor targeting in carcinomas of the prostate, head and neck, thyroid, breast, and lung, as well as in gynecologic, brain, and paraspinal tumors and soft tissue sarcomas. In prostate cancer, intensity-modulated radiotherapy has resulted in reduced rectal toxicity and has permitted tumor dose escalation to previously unattainable levels. This experience indicates that intensity-modulated radiotherapy represents a significant advancement in the ability to deliver the high radiation doses that appear to be required to improve the local cure of several types of tumors. The integration of new methods of biologically based imaging into treatment planning is being explored to identify tumor foci with phenotypic expressions of radiation resistance, which would likely require high-dose treatments. Intensity-modulated radiotherapy provides an approach for differential dose painting to selectively increase the dose to specific tumor-bearing regions. The implementation of biologic evaluation of tumor sensitivity, in addition to methods that improve target delineation and dose delivery, represents a new dimension in intensity-modulated radiotherapy research.

Abdominal Neoplasms↗