Search PubMed⌕ Search

Biomedical subjects

Sonia Chawla

Publications and source records attributed to Sonia Chawla.

4 recordsLinked to original sources

Postpartum feeding attitudes, maternal depression, and breastfeeding in Barbados.

Maternal feeding attitudes, maternal moods and infant feeding practices during the first 6 months postpartum were assessed in 226 healthy, well-nourished Barbadian mother-infant dyads. Factor analysis of the feeding attitudes questionnaire resulted in six independent factors. The belief that breastfeeding was better than bottle-feeding was associated with higher family income, more information seeking behavior and older maternal age at the time of her first pregnancy. Women who believed that breastfeeding was better at 7 weeks postpartum were also more likely to breastfeed at concurrent and later ages, up to 6 months postpartum. This belief was also associated with less maternal depression at 7 weeks and 6 months. The association between feeding attitudes and actual feeding practices was significant even after correcting for maternal moods and other background variables. Conversely, after controlling for feeding attitudes, maternal mood at 7 weeks was still significantly associated with infant feeding practices at 6 months. Thus, feeding attitudes and maternal moods were closely linked, but each contributed independently and uniquely to different aspects of breastfeeding, especially at 6 months. These findings suggest that early intervention addressing maternal feeding attitudes, may improve the extent of breastfeeding and the health of children in this setting.

Adult↗

High-performance liquid chromatography method development and validation for simultaneous determination of five model compounds, antipyrine, metoprolol, ketoprofen, furosemide and phenol red, as a tool for the standardization of rat in situ intestinal permeability studies using timed wavelength detection.

A simple, precise, accurate and rugged reversed-phase high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of five permeability model compounds, viz. antipyrine, metoprolol, ketoprofen, furosemide and phenol red. The method was intended to standardize rat in situ single-pass intestinal perfusion studies to assess the intestinal permeability of drugs in the market as well as new chemical entities. Optimum resolution was achieved by gradient elution on a Symmetry Shield C-18 analytical column with the mobile phase consisting of a mixture of aqueous potassium dihydrogen orthophosphate (pH 5.5; 0.01 m) and methanol at a flow rate of 1.5 mL/min. The retention times of antipyrine, metoprolol, ketoprofen, phenol red and furosemide were about 9, 12, 13, 16 and 17 min, respectively. Data acquisition was carried out using a photo diode array detector in the wavelength range 210-600 nm. Extraction of chromatograms was carried out by timed wavelength. Data obtained in all studies indicated that the method was suitable for the intended purpose. The validated method was found to be linear and precise in the working range. Suitability of storage under various conditions and freeze/thaw impact at cold temperature were established to ensure complete sample recovery without any stability issues. Recovery very close to the spiked amounts indicated that the method was highly accurate and suitable for use on routine basis.

Animals↗

Validated HPLC analytical method with programmed wavelength UV detection for simultaneous determination of DRF-4367 and Phenol red in rat in situ intestinal perfusion study.

A simple, precise and accurate isocratic reverse-phase liquid chromatography method with programmed wavelength detection has been validated to quantify DRF-4367 and Phenol red, simultaneously for application in rat in situ single pass intestinal perfusion study to assess intestinal permeability of DRF-4367, a novel cox-2 inhibitor. The method was validated on RP C-18 analytical column. Mobile phase consisted of sodium dihydrogen orthophosphate (pH 3.2, 0.01 M)-acetonitrile-methanol (30:50:20, v/v/v). The developed method has a short run time of 12 min with a flow rate of 1.0 ml/min. The injector volume was set to 20 microl and acquisition was carried out using a PDA detector while processing was done by timed wavelength extraction. The percentage R.S.D. and recovery in all studies indicated that the method was suitable for the intended purpose. The validated method was found to be linear and precise in the working range. Suitability of storage at cold temperature was ensured along with complete sample recovery.

Animals↗

Night and day: are siblings as different in temperament as parents say they are?

Twin studies suggest that parent ratings of temperament exaggerate differences between twins. The present study examined whether such contrast effects also operate for nontwin siblings. The activity level (AL) and shyness of 95 nontwin sibling pairs (ages 3 to 8 years) were assessed via parent ratings and objective measures (actigraph and observer ratings). Siblings showed no resemblance in either parent-rated AL or shyness; however, sibling resemblance for actigraph AL and observer-rated shyness was substantial. Thus, parents do contrast their nontwin siblings when rating these 2 temperament dimensions. Moreover, the importance of sibling differences in temperament to the sibling relationship and differential maternal treatment varied across the different measures of AL and shyness, suggesting that parent perceptions may play a role in these associations.

Child↗