Search PubMed⌕ Search

Biomedical subjects

Simon Wildermuth

Publications and source records attributed to Simon Wildermuth.

44 records · Page 3Linked to original sources

Aortoiliac and renal arteries: prospective intraindividual comparison of contrast-enhanced three-dimensional MR angiography and multi-detector row CT angiography.

PURPOSE: To compare contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography and multi-detector row computed tomographic (CT) angiography in the same patients for assessment of the aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the standard of reference. MATERIALS AND METHODS: DSA, 3D MR angiography, and multi-detector row CT angiography were performed in 46 consecutive patients. A total of 769 arterial segments were analyzed for arterial stenosis by using a four-point grading system. Aneurysmal changes were noted. The time required for performing 3D reconstructions and image analysis of both MR and CT data sets was measured. Patient acceptance for each modality was assessed with a visual analogue scale. Statistical analysis of data was performed. RESULTS: Sensitivity of MR angiography for detection of hemodynamically significant arterial stenosis was 92% for reader 1 and 93% for reader 2, and specificity was 100% and 99%, respectively. Sensitivity of CT angiography was 91% for reader 1 and 92% for reader 2, and specificity was 99% and 99%, respectively. Differences between the two modalities were not significant. Interobserver and intermodality agreement was excellent (kappa = 0.88-0.90). The time for performance of 3D reconstruction and image analysis of CT data sets was significantly longer than that for MR data sets (P <.001). Patient acceptance was best for CT angiography (P =.016). CONCLUSION: There is no statistically significant difference between 3D MR angiography and multi-detector row CT angiography in the detection of hemodynamically significant arterial stenosis of the aortoiliac and renal arteries.

Aged↗

Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool.

PURPOSE: The purpose of this study was to assess accuracy and reliability of a volumetric analysis of abdominal aneurysms on the basis of multidetector row computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) with a commercially available automated vessel analysis software program. MATERIALS AND METHODS: Twenty patients with abdominal aortic aneurysms underwent preoperative CTA and MRA before endovascular repair. Postdeployment CTA was performed in 15 of these 20 patients (75%). All preoperative CTA and MRA and postdeployment CTA data sets were analyzed with an automated software tool. The length of the stent grafts on postdeployment CTA was measured and compared with the true length of the primary component. Two readers independently evaluated 13 vessel parameters on preoperative CTA and MRA, which are considered to be important in planning stent graft deployment. RESULTS: With the automated analysis software tool, all measurements could be performed on either CTA or MRA data sets. There was no statistically significant difference between postdeployment measurements of stent graft length on CTA and the true dimensions of the implanted stent grafts. Interobserver agreement for all of the measurements with either CTA or MRA was good to excellent (interclass coefficient, 0.71 to 0.99) with only minimal mean differences of measured dimensions between both readers (range, -2.0 to +2.3 mm, Bland-Altman). Intermodality agreement between CTA and MRA was good to excellent (interclass coefficient, 0.62 to 0.98) with small mean differences of measured dimensions between both methods (range, -4.1 to +2.1 mm, Bland-Altman). CONCLUSION: Volumetric measurement with an automated analysis software tool allows a fast, precise, and reliable noninvasive preoperative determination of all aortic dimensions on the basis of either CTA or MRA data sets.

Aged↗

Endovascular therapeutic options for isolated iliac aneurysms with a working classification.

The purpose of this paper is to demonstrate a variety of stent-grafting and embolization techniques and describe a new classification for endovascular treatment of isolated iliac artery aneurysms. A total of 19 patients were treated for isolated iliac aneurysms. Depending on the proximal iliac neck and the uni-/bilaterality of common iliac artery aneurysms (CIAA's) the patient may be treated by a tube (Type Ia) or a bifurcated stent-graft (Type Ib) in addition to internal iliac artery embolization. Neck anatomy is also critical in determining therapeutical options for internal iliac artery aneurysms (IIAA's). These are tube stent-grafting plus internal iliac branch embolization (Type IIa), coiling of afferent and efferent internal iliac vessels (Type IIb) and IIAA packing (Type IIc). The average length of stay for these procedures was 3.8 days. During the mean follow-up of 20.9 months, aneurysm size remained unchanged in all but 4 patients. Reinterventions were necessary in option Type Ib (3/8 pat.) and Type Ia (1/7 pat.) due to extender stent-graft migration (n = 2) or reperfusion leaks (n = 2). We conclude that Iliac artery aneurysms may be successfully and safely treated by a tailored approach using embolization or a combination of embolization and stent-grafting. Long-term CT imaging follow-up is necessary, particularly in patients treated with bifurcated stent-grafts (Type Ib).

Aged↗

Computational fluid dynamics: hemodynamic changes in abdominal aortic aneurysm after stent-graft implantation.

The aim of this study was to demonstrate quantitatively and qualitatively the hemodynamic changes in abdominal aortic aneurysms (AAA) after stent-graft placement based on multidetector CT angiography (MDCT-A) datasets using the possibilities of computational fluid dynamics (CFD). Eleven patients with AAA and one patient with left-side common iliac aneurysm undergoing MDCT-A before and after stent-graft implantation were included. Based on the CT datasets, three-dimensional grid-based models of AAA were built. The minimal size of tetrahedrons was determined for grid-independence simulation. The CFD program was validated by comparing the calculated flow with an experimentally generated flow in an identical, anatomically correct silicon model of an AAA. Based on the results, pulsatile flow was simulated. A laminar, incompressible flow-based inlet condition, zero traction-force outlet boundary, and a no-slip wall boundary condition was applied. The measured flow volume and visualized flow pattern, wall pressure, and wall shear stress before and after stent-graft implantation were compared. The experimentally and numerically generated streamlines are highly congruent. After stenting, the simulation shows a reduction of wall pressure and wall shear stress and a more equal flow through both external iliac arteries after stenting. The postimplantation flow pattern is characterized by a reduction of turbulences. New areas of high pressure and shear stress appear at the stent bifurcation and docking area. CFD is a versatile and noninvasive tool to demonstrate changes of flow rate and flow pattern caused by stent-graft implantation. The desired effect and possible complications of a stent-graft implantation can be visualized. CFD is a highly promising technique and improves our understanding of the local structural and fluid dynamic conditions for abdominal aortic stent placement.

Aortic Aneurysm, Abdominal↗

Accuracy and time efficiency for the detection of thoracic cage fractures: volume rendering compared with transverse computed tomography images.

OBJECTIVE: To compare the accuracy and time efficiency of volume rendering (VR) compared with transverse images of multidetector-row computed tomography data to identify thoracic cage fractures. METHODS: Computed tomography scans of 50 patients with acute blunt chest trauma were retrospectively analyzed by using VR and transverse images. The number, location, and type of rib and sternal fractures revealed by these viewing methods were compared, and the time needed for diagnosis was measured. RESULTS: Thirty of 50 patients had a total of 178 rib fractures. The mean sensitivity, specificity, and accuracy for their detection were similar for transverse (96%, 100%, and 99%) and VR (98%, 100%, and 100%) images. Three sternal fractures were correctly diagnosed with VR, and 1 was missed on transverse images by both readers. The time to read VR images (mean of 105 seconds) was significantly reduced compared with the time needed for transverse image reading (mean of 167 seconds; P < 0.001). CONCLUSION: Volume rendering of computed tomography data depicts thoracic cage fractures with a high accuracy similar to that of transverse images but is considerably faster.

Adolescent↗

Experience of 4 years with open MR defecography: pictorial review of anorectal anatomy and disease.

Functional disorders of the pelvic floor are a common clinical problem. Diagnosis and treatment of these disorders, which frequently manifest with nonspecific symptoms such as constipation or incontinence, remain difficult. Fluoroscopic x-ray defecography has been shown to aid in detection of functional and morphologic abnormalities of the anorectal region. With the advent of open-configuration magnetic resonance (MR) imaging systems, MR defecography with the patient in a vertical position became possible. MR defecography permits analysis of the anorectal angle, the opening of the anal canal, the function of the puborectal muscle, and the descent of the pelvic floor during defecation. Good demonstration of the rectal wall permits visualization of intussusceptions and rectoceles. Excellent demonstration of the perirectal soft tissues allows assessment of spastic pelvic floor syndrome and descending perineum syndrome and visualization of enteroceles. MR defecography with an open-configuration magnet allows accurate assessment of anorectal morphology and function in relation to surrounding structures without exposing the patient to harmful ionizing radiation.

Adolescent↗

Nontraumatic emergent abdominal vascular conditions: advantages of multi-detector row CT and three-dimensional imaging.

In the past decade, great strides have been made in the development of helical computed tomography (CT) that have led to shorter scanning time and higher spatial resolution. A wide range of traumatic and nontraumatic emergent conditions may be quickly and accurately diagnosed with multi-detector row CT. Multi-detector row CT angiography is the preferred method for imaging in emergent abdominal vascular conditions because it enables the acquisition of high-spatial-resolution volumetric image data during a single breath hold. Unlike catheter angiography, multi-detector row CT angiography not only depicts the vessels but also allows assessment of perfusion in adjacent organs. To make the most effective diagnostic use of multi-detector row CT angiography and three-dimensional image postprocessing, radiologists must be familiar with the optimal CT angiographic protocols and with the typical CT findings in various emergent vascular conditions. This article describes the protocols used in 11 patients with conditions including ruptured abdominal aortic aneurysm, secondary aortoduodenal fistula, splanchnic segmental arterial mediolysis, and Wegener-type vasculitis with visceral involvement. All of the diagnoses in these 11 cases were made in the emergency department, and the delay between imaging and diagnosis was decreased considerably by avoiding the transfer of patients for catheter angiography.

Abdomen, Acute↗

Vascular emergencies of the thorax after blunt and iatrogenic trauma: multi-detector row CT and three-dimensional imaging.

Multi-detector row computed tomographic (CT) angiography is an effective modality for vascular imaging in the thorax. It allows acquisition of high-resolution data sets during a single breath hold, making it the preferred method for evaluation of patients with acute vascular disease. In contrast to conventional angiography, multirow CT angiography not only depicts the vessels but also allows assessment of adjacent structures. Multirow CT angiography with two- and three-dimensional reformation can be used to diagnose vascular emergencies of the thorax after blunt and iatrogenic trauma. These include incomplete and complete aortic rupture; traumatic aortic dissection; arterial dissection and rupture after minor trauma in patients with Ehlers-Danlos syndrome; traumatic intramural hematoma; pseudoaneurysm after endovascular repair; injuries due to Swan-Ganz catheters; complications of central venous cannulation, pacemaker implantation, and percutaneous pericardial drainage; and foreign-body embolism. The diagnoses can be established with multirow CT angiography in the emergency department. Thus, the time to diagnosis can be considerably decreased by obviating conventional angiography. Knowledge of the CT findings in various vascular conditions is essential to make use of multirow CT angiography in combination with two- and three-dimensional reformation as an efficient and accurate diagnostic tool in emergency radiology.

Adult↗