Search PubMed⌕ Search

Biomedical subjects

Sichun Zhang

Publications and source records attributed to Sichun Zhang.

9 recordsLinked to original sources

A catalytic nanomaterial-based optical chemo-sensor array.

An optical sensor array based on chemiluminescent images from spots of nanomaterials has been employed to recognize odorous samples. The distinctive images obtained from the array permit identification of a wide range of analytes, even homologous compounds.

Journal Article↗

Generation and optical properties of monodisperse wurtzite-type ZnS microspheres.

Monodisperse wurtzite-type ZnS microspheres have been prepared by using glutathione (GSH) as a sulfur source at low reaction temperatures ranging from 160 to 210 degrees C. The diameter of the ZnS microspheres can be tuned from approximately 254 to approximately 597 nm by changing the reaction parameters such as temperature, molar ratio of reactants (GSH/Zn2+), and reaction medium (ethylenediamine or ammonia). Our results demonstrate that monodentate amines (ammonia) play the same role as that of bidentate amines (ethylenediamine) in the formation of the wurtzite-type ZnS microspheres. The formation process of the monodisperse ZnS microspheres consists of a GSH-dominated nucleation process and an amine-dominated assembly process. The as-synthesized monodisperse ZnS microspheres readily self-assemble into ordered hexagonal patterns and thus have potential applications as colloidal crystalline materials. Blue fluorescence emission peaks at 415 and 466 nm in wavelength, attributed to deep-trap emission, are observed at room temperature.

Journal Article↗

Growth and optical properties of wurtzite-type CdS nanocrystals.

This paper reports wurtzite-type CdS nanostructures synthesized via a hydrothermal reaction route using dithiol glycol as the sulfur source. The reaction time was found to play an important role in the shape of the CdS nanocrystals: from dots to wires via an oriented attachment mechanism. This work has enabled us to generate nanostructures with controllable geometric shapes and structures and thus optical properties. The CdS nanostructures show a hexagonal wurtzite phase confirmed by X-ray diffraction and show no evidence for a mixed phase of cubic symmetry. The Raman peak position of the characteristic first-order longitudinal optical phonon mode does not change greatly, and the corresponding full width at half-maximum is found to decrease with the CdS shape, changing from nanoparticles to nanowires because of crystalline quality improvement. The photoluminescence measurements indicate tunable optical properties just through a change in the shape of the CdS nanocrystals; i.e., CdS nanoparticles show a band-edge emission at approximately 426 nm in wavelength, while the CdS nanowires show a band-edge emission at approximately 426 nm as well as a weaker trap-state green emission at approximately 530 nm in wavelength. These samples provide an opportunity for the study of the evolution of crystal growth and optical properties, with the shape of the nanocrystals varying from nearly spherical particles to wires.

Journal Article↗

Atomization of hydride with a low-temperature, atmospheric pressure dielectric barrier discharge and its application to arsenic speciation with atomic absorption spectrometry.

This paper describes a novel hydride atomizer based on atmospheric pressure dielectric barrier discharge (DBD) plasma. The plasma was generated with a 3700-V, 20.3-kHz, and 5-W electrical power supply and easily sustained with inert gases (He or Ar) at a flow rate of 250 mL.min(-1) after optimization. However, it cannot be sustained with N2. This atomizer offers the advantages of low operation temperature and low power consumption in comparison with the currently used electrothermal quartz atomization operated at 900 degrees C with a power supply of several hundred watts. To confirm the utility of the proposed atomizer, four arsenic species (As(III), As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA)) were determined by the present atomization technique. A hyphenation of HPLC coupled to hydride generation AAS with the optimized DBD atomizer has been successfully used for the speciation of arsenic in order to demonstrate the potential of this atomizer in the present study. The characteristics of the DBD atomizer and the effects of different parameters (discharge gas, gas flow rate, voltage, HCl concentration, KBH4 concentration) are discussed in the paper. Compared with other hydride atomization techniques, the proposed method shows the following features: (1) small size (70 mm x 15 mm x 5 mm), which is preferable for the miniaturization of the total analytical system; (2) low power consumption (< or =5 W), which indicates the possibility of the development of portable, fieldable analytical instrumentation for in situ detection using battery as power supply; (3) low atomizer temperature (approximately 70 degrees C), which is in favor of the compactness of the total instruments; (4) avoidance of residue moisture removal in comparison with the existed GD system, which leads to the facility of the system. The analytical figures of the present technique were evaluated. The detection limits of As(III), As(V), MMA, and DMA obtained with HG-DBD-AAS were 1.0, 11.8, 2.0, and 18.0 microg.L(-1), respectively. The accuracy of the system was verified by the determination of arsenic in reference material of orchard leaves SRM 1571. The concentration of As determined by the present method agreed well with the reference values. The speciation of arsenic in the freeze-dried urine SRM 2670 were carried out, and the results obtained were in agreement with the results of HPLC-ICPMS and the reported values by other laboratories.

Journal Article↗

Development of an aerosol chemiluminescent detector coupled to capillary electrophoresis for saccharide analysis.

A novel aerosol chemiluminescent (CL) detector coupling to capillary electrophoresis (CE) for the detection of saccharides is reported. This CL detector is composed of a postcapillary nebulizer and porous alumina as catalyzer in quartz tube. The CL emission could be generated due to the catalyzing oxidization of saccharides on the surface of porous alumina. The saccharides such as sucrose, alpha-lactose, maltose, raffinose, galactose, xylose, and glucose with only weak UV absorbance can be successfully detected. The linear ranges of those saccharides are from 30-2000 to 50-2000 mg/L; relative standard deviations range from 2.1 to 3.7% (200 mg/L, n = 11). Compared with the traditional UV detector currently used in CE, this novel detector shows the advantage of high sensitivity to the compounds with only weak UV absorption. Thus, it could be an important supplement of CE detectors for UV-lacking compounds.

Aerosols↗

Development of a detector for liquid chromatography based on aerosol chemiluminescence on porous alumina.

This paper describes a novel aerosol chemiluminescence-based detector, which can be coupled to liquid chromatography for the determination of the chemicals with weak optical absorbance in the UV-visible region. This aerosol chemiluminescence (CL)-based detector, in which HPLC effluent is converted to aerosol and then generated CL emission on the surface of porous alumina, is composed of three main processes: nebulization of HPLC effluent, CL emission on surface of porous alumina material, and optical detection. To demonstrate the utility of the aerosol chemiluminescence detector, some compounds such saccharides, poly(ethylene glycol)s, amino acids, and steroid pharmaceuticals are determined by the present aerosol chemiluminescence detection method. Compared with an evaporative light scattering detector, the proposed detector shows the following features: (a) extensive CL emissions on porous alumina by many compounds tested, which leads to the potential application for the determination of volatile and nonvolatile chemicals with or without UV-visible absorbance; (b) a CL mechanism based on the catalytic oxidation of analytes, not on the light scattering, which suggests the present detector be free from the interference of the inorganic and nonvolatile mobile-phase modifiers. The CL characteristics and effect of different parameters, such as temperature and nebulizer gas flow rate, were also discussed in this paper. Furthermore, this aerosol chemiluminescence-based detector was successfully applied to the determination of raffinose, glucose, sucrose, maltose, and alpha-lactose.

Journal Article↗

Simultaneous determination of alpha-fetoprotein and free beta-human chorionic gonadotropin by element-tagged immunoassay with detection by inductively coupled plasma mass spectrometry.

BACKGROUND: An inductively coupled plasma mass spectrometry (ICP-MS)-based immunoassay has been proposed independently by Baranov et al. (Anal Chem 2002;74:1629-36) and our group, but the applicability of this method for multianalyte analysis in clinical samples has not been fully illustrated. We developed a dual-label immunoassay method for the simultaneous determination of alpha-fetoprotein (AFP) and free beta-human chorionic gonadotropin (hCGbeta) in human serum. METHODS: Monoclonal antibodies immobilized on microtiter plates captured AFP and hCGbeta, which were detected by use of Eu(3+)-labeled anti-AFP and Sm(3+)-labeled anti-hCGbeta monoclonal antibodies. Eu(3+) and Sm(3+) were dissociated from the immunocomplex with HNO(3) solution (10 mL/L) and delivered by peristaltic pump to the ICP mass spectrometer. RESULTS: The measurable ranges of AFP and hCGbeta were 4.6-500 and 5.0-170 microg/L, respectively, with detection limits of 1.2 and 1.7 microg/L (3 SD above mean of zero calibrator), respectively. The intraassay imprecision (CV) for AFP was 8.3%, 4.0%, and 2.7% at 16.3, 86, and 354 microg/L, respectively, and the interassay CV was 10%, 5.7%, and 3.5%. For hCGbeta, the intraassay CV was 5.4%, 6.4%, and 3.1%, respectively, at 10.5, 45.2, and 105 microg/L, and the interassay CV was 7.2%, 8.0%, and 3.7%. Comparison with IRMAs for AFP and hCGbeta yielded correlation coefficients (r(2)) of 0.97 and 0.95. CONCLUSIONS: Two proteins can be measured simultaneously by immunoassays using two rare earth elemental tags (Eu(3+) and Sm(3+)) and ICP-MS detection. The multielement capability and the multiple potential elemental labels make ICP-MS attractive for multianalyte immunoassays. Implementation of ICP-MS-linked immunoassays may be relatively straightforward because the labeling and immunoreaction procedures have been well developed for clinical time-resolved immunofluorometric assays.

Antibodies, Monoclonal↗