Search PubMed⌕ Search

Biomedical subjects

Shouhei Yamamura

Publications and source records attributed to Shouhei Yamamura.

4 recordsLinked to original sources

Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes.

A novel method for DNA quantification and specific sequence detection in a highly integrated silicon microchamber array is described. Polymerase chain reaction (PCR) mixture of only 40 nL volume could be introduced precisely into each chamber of the mineral oil layer coated microarray by using a nanoliter dispensing system. The elimination of carry-over and cross-contamination between microchambers, and multiple DNA amplification and detection by TaqMan chemistry were demonstrated, for the first time, by using our system. Five different gene targets, related to Escherichia coli were amplified and detected simultaneously on the same chip by using DNA from three different serotypes as the templates. The conventional method of DNA quantification, which depends on the real-time monitoring of variations in fluorescence intensity, was not applied to our system, instead a simple method was established. Counting the number of the microchambers with a high fluorescence signal as a consequence of TaqMan PCR provided the precise quantification of trace amounts of DNA. The initial DNA concentration for Rhesus D (RhD) gene in each microchamber was ranged from 0.4 to 12 copies, and quantification was achieved by observing the changes in the released fluorescence signals of the microchambers on the chip. DNA target could be detected as small as 0.4 copies. The amplified DNA was detected with a CCD camera built-in to a fluorescence microscope, and also evaluated by a DNA microarray scanner with associated software. This simple method of counting the high fluorescence signal released in microchambers as a consequence of TaqMan PCR was further integrated with a portable miniaturized thermal cycler unit. Such a small device is surely a strong candidate for low-cost DNA amplification, and detected as little as 0.4 copies of target DNA.

Biosensing Techniques↗

On-chip micro-flow polystyrene bead-based immunoassay for quantitative detection of tacrolimus (FK506).

Tacrolimus (FK506) is a widely used immunosuppressant for preventing allograft rejection and the treatment of atopic dermatitis. FK506 necessitates therapeutic drug monitoring because of inter- and intrapatient variability and the lack of correlation between the administered dose and the blood concentration. Previous immunoassay-based methods required a relatively long assay time and troublesome liquid-handling procedures. In the present study, we aimed to establish a rapid monitoring method for FK506 determination by using a poly(dimethylsiloxane) (PDMS)-based microfluidic device. Polystyrene beads were coated with mouse anti-FK506 antibody and placed in the flow channel. As a competitive assay, sample solution was allowed to react in the flow channel. After the addition of the fluorogenic substrate, the fluorescent signal was observed under a microscope. As a result, the developed assay allowed a short detection time of approximately 15 min per each sample and a high sensitivity even by using only a single bead. The feasibility of performing a competitive assay using a PDMS-based antibody chip gives promising results over the existing immunoassay-based methods.

Animals↗

On-chip nanoliter-volume multiplex TaqMan polymerase chain reaction from a single copy based on counting fluorescence released microchambers.

A novel method for multiplex TaqMan PCR in nanoliter volumes on a highly integrated silicon microchamber array is described. Three different gene targets, related to beta-actin, sex-determining region Y (SRY), and Rhesus D (RhD) were amplified and detected simultaneously on the same chip by using three different types of human genomic DNA as the templates. The lack of cross-contamination and carryover was shown using alternate dispensing of mineral oil-coated microchambers containing template and those without template. To confirm the specificity of our system to beta-actin, SRY, and RhD genes, we employed the larger volume PCR samples to a commercial real-time PCR system, SmartCycler. The samples were cycled with the same sustaining temperatures as with the microchamber array. Instead of the conventional method of DNA quantification, counting the number of the fluorescence released microchambers in consequence to TaqMan PCR was employed to our chip. This simple method of observing the end point signal had provided a dynamic quantitative range. Stochastic amplification of 0.4 copies/reaction chamber was achieved. The microfabricated PCR chip demonstrated a rapid and highly sensitive response for simultaneous multiple-target detection, which is a promising step toward the development of a fully integrated device for the "lab-on-a-chip" DNA analysis.

Actins↗