Guide wire reconstruction and visualization in 3DRA using monoplane fluoroscopic imaging.

A method has been developed that, based on the guide wire position in monoplane fluoroscopic images, visualizes the approximate guide wire position in the three-dimensional (3-D) vasculature, that is obtained prior to the intervention with 3-D rotational X-ray angiography (3DRA). The method assumes the position of the guide wire in the fluoroscopic images is known. A two-dimensional feature image is determined from the 3DRA data. In this feature image, the guide wire position is determined in a two-step approach: a mincost algorithm is used to determine a suitable position for the guide wire, and subsequently a snake optimization technique is applied to move the guide wire to a better position. The resulting guide wire can then be visualized in 3-D in combination with the 3DRA dataset. The reconstruction accuracy of the method has been evaluated using a 3DRA image of a vascular phantom filled with contrast, and monoplane fluoroscopic images of the same phantom without contrast and with a guide wire inserted. The evaluation has been performed for different projection angles, and with different parameters for the method. The final result does not appear to be very sensitive to the parameters of the method. The average mean error of the estimated 3-D guide wire position is 1.5 mm, and the average tip distance is 2.3 mm. The effect of inaccurate C-arm geometry information is also investigated. Small errors in geometry information (up to 1 degrees) will slightly decrease the 3-D reconstruction accuracies, with an error of at most 1 mm. The feasibility of this approach on clinical data is demonstrated.

Algorithms↗

Endpoint localization in guide wire tracking during endovascular interventions.

RATIONALE AND OBJECTIVES: A method is presented to track guide wires during endovascular interventions under X-ray fluoroscopy. Accurate guide wire tracking can be used to improve guide wire visualization in the low quality fluoroscopic images, and to estimate the position of the guide wire in world coordinates for navigation purposes. MATERIALS AND METHODS: A two-step procedure is used to track the guide wire in subsequent frames. First, the position of the guide wire is obtained by fitting a spline to the image. Subsequently, the spline is iteratively moved toward the tip of the guide wire for accurate tip localization. For both steps, a feature image is used in which line-like structures are enhanced. The method is validated using a reference standard, obtained by manual tracings of three observers. RESULTS: The method is evaluated on 20 image sequences, 10 sequences with a J-tipped guide wire and 10 with a straight guide wire. The tracking success was 96% for J-tipped and 100% for straight guide wires, whereas accurate endpoint localization could be performed in 91.3% and 94.4% of the frames respectively, with a tip localization error of less than 1.5 mm. CONCLUSIONS: Accurate endpoint localization can be performed for both J-tipped and straight guide wires and therefore the presented tracking method can be used for navigation purposes.

Algorithms↗

Guide-wire tracking during endovascular interventions.

A method is presented to extract and track the position of a guide wire during endovascular interventions under X-ray fluoroscopy. The method can be used to improve guide-wire visualization in low-quality fluoroscopic images and to estimate the position of the guide wire in world coordinates. A two-step procedure is utilized to track the guide wire in subsequent frames. First, a rough estimate of the displacement is obtained using a template-matching procedure. Subsequently, the position of the guide wire is determined by fitting a spline to a feature image. The feature images that have been considered enhance line-like structures on: 1) the original images; 2) subtraction images; and 3) preprocessed images in which coherent structures are enhanced. In the optimization step, the influence of the scale at which the feature is calculated and the additional value of using directional information is investigated. The method is evaluated on 267 frames from ten clinical image sequences. Using the automatic method, the guide wire could be tracked in 96% of the frames, with a similar accuracy to three observers, although the position of the tip was estimated less accurately.

Algorithms↗

Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature.

Using three-dimensional rotational X-ray angiography (3DRA), three-dimensional (3-D) information of the vasculature can be obtained prior to endovascular interventions. However, during interventions, the radiologist has to rely on fluoroscopy images to manipulate the guide wire. In order to take full advantage of the 3-D information from 3DRA data during endovascular interventions, a method is presented that yields an integrated display of the position of the guide wire and vasculature in 3-D. The method relies on an automated method that tracks the guide wire simultaneously in biplane fluoroscopy images. Based on the calibrated geometry of the C-arm, the 3-D guide-wire position is determined and visualized in the 3-D coordinate system of the vasculature. The method is evaluated in an intracranial anthropomorphic vascular phantom. The influence of the angle between projections, distortion correction of the projection images, and accuracy of geometry knowledge on the accuracy of 3-D guide-wire reconstruction from biplane images is determined. If the calibrated geometry information is used and the images are corrected for distortion, a mean distance to the reference standard of 0.42 mm and a tip distance of 0.65 mm is found, which means that accurate guide-wire reconstruction from biplane images can be performed.

Algorithms↗