Low-frequency electrical stimulation increases muscle strength and improves blood supply in patients with chronic heart failure.

BACKGROUND: This study was designed to evaluate the effects of low-frequency electrical stimulation (LFES) on muscle strength and blood flow in patients with advanced chronic heart failure (CHF). METHODS AND RESULTS: Patients with CHF (n=15; age 56.5 +/- 5.2 years; New York Heart Association III - IV; ejection fraction 18.7 +/- 3.3%) were examined before and after 6 weeks of LFES (10 Hz) of the quadriceps and calf muscles of both legs (1 h/day, 7 days/week). Dynamometry was performed weekly to determine maximal muscle strength (F(max); N) and isokinetic peak torque (PT(max); Nm); blood flow velocity (BFV) was measured at baseline and after 6 weeks of LFES using pulsed-wave Doppler velocimetry of the right femoral artery. Six weeks of LFES significantly increased F(max) (from 224.5 +/- 96.8 N to 340.0 +/- 99.4 N; p<0.001), and also PT(max) (from 94.5 +/- 41.5 Nm to 135.3 +/- 28.8 Nm; p<0.01). BFV in the femoral artery increased after 6 weeks from 35.7 +/- 15.4 cm/s to 48.2 +/- 18.1 cm/s (p<0.05); BFV values at rest before and after 6 weeks of LFES did not differ significantly. CONCLUSIONS: LFES may improve muscle strength and blood supply, and could be recommended for the treatment of patients with severe CHF.

Biomarkers↗

Electrical stimulation of skeletal muscles. An alternative to aerobic exercise training in patients with chronic heart failure?

The aim of this study was to investigate whether electrical stimulation of skeletal muscles could represent a rehabilitation alternative for patients with chronic heart failure (CHF). Thirty patients with CHF and NYHA class II-III were randomly assigned to a rehabilitation program using either electrical stimulation of skeletal muscles or bicycle training. Patients in the first group (n = 15) had 8 weeks of home-based low-frequency electrical stimulation (LFES) applied simultaneously to the quadriceps and calf muscles of both legs (1 h/day for 7 days/week); patients in the second group (n = 15) underwent 8 weeks of 40 minute aerobic exercise (3 times a week). After the 8-week period significant increases in several functional parameters were observed in both groups: maximal VO2 uptake (LFES group: from 17.5 +/- 4.4 mL/kg/min to 18.3 +/- 4.2 mL/kg/min, P < 0.05; bicycle group: from 18.1 +/- 3.9 mL/kg/min to 19.3 +/- 4.1 mL/kg/min, P < 0.01), maximal workload (LFES group: from 84.3 +/- 15.2 W to 95.9 +/- 9.8 W, P < 0.05; bicycle group: from 91.2 +/- 13.4 W to 112.9 +/- 10.8 W, P < 0.01), distance walked in 6 minutes (LFES group: from 398 +/- 105 m to 435 +/- 112 m, P < 0.05; bicycle group: from 425 +/- 118 m to 483 +/- 120 m, P < 0.03), and exercise duration (LFES group: from 488 +/- 45 seconds to 568 +/- 120 seconds, P < 0.05; bicycle group: from 510 +/- 90 seconds to 611 +/- 112 seconds, P < 0.03). These results demonstrate that an improvement of exercise capacities can be achieved either by classical exercise training or by home-based electrical stimulation. LFES should be considered as a valuable alternative to classical exercise training in patients with CHF.

Bicycling↗

Development of the pulsation device for rotary blood pumps.

A rotary blood pump (RP) is desirable as a small ventricular assist device (VAD). However, an RP is nonpulsatile. We tried to develop a device that attaches a pulse to the RP. We also tried to develop a pulse-generating equipment that was not air-pressure driven. The ball screw motor was considered a candidate. The application of a small-sized shape memory alloy was also attempted. An electrohydraulic system was adopted, and actuator power was connected to the diaphragm. The diaphragm was placed on the outer side of the ventricle. Most RPs that have been developed all over the world drain blood from the ventricle. The wave of a pulse should be generated if a pulse is added by the drawn part. The output assistance from the outer side of the ventricle was attempted in animal experiments, and the device operated effectively. This device can be used during implantable operation of RP. This may serve as an effective device in patients experiencing problems in peripheral circulation and in the function of internal organs.

Animals↗

Development of an ultra-portable echo device connected to USB port.

In practical cardiology, a stethoscope based auscultation has been used to reveal the patient's clinical status. Recently, several hand-held echo devices are going on market and they are expected to play a role as "visible" auscultation instead of stethoscope. We have developed a portable and inexpensive echo device which can be used for screening of cardiac function. Two single element transducers were attached 180 degrees apart to a rotor with 14-mm diameter. The mechanical scanner, integrated circuits for transmitting and receiving ultrasonic signals and an A/D converter were encapsulated in a 150 x 40 mm probe weighing 200 g. The scan was started and the image was displayed on a Windows based personal computer (PC) as soon as the probe was connected to USB 2.0 port of the PC. The central frequency was available between 2.5 and 7.5 MHz, the image depth was 15 cm and the frame rate was 30/s. The estimated price of this ultra-portable ultrasound is about 3000 US dollars with software. For 69 cardiac patients with informed consent, image quality was compared with those obtained with basic range diagnostic echo machines. Left ventricular ejection fraction (EF) derived from normal M-mode image of standard machines (EFm) were compared with visual EF of the ultra-portable ultrasound device (EFv). The image quality was comparable to the basic range diagnostic echo machines although short axis view of aortic root was not clearly visualized because the probe was too large for intercostal approach. EFv agreed well with EFm. The ultra-portable ultrasound may provide useful information on screening and health care.

Echocardiography↗

Acoustic properties of aortic aneurysm obtained with scanning acoustic microscopy.

In aortic aneurysm tissues, macrophages and their secretion of matrix metalloproteinases (MMPs) are playing important role for tissue degeneration. Some studies have shown that weakening of the mechanical properties of the degenerated tissues may progress the expansion of the aneurysm. However, actual measurement of the mechanical properties has not been investigated at microscopic level. The objective of the present study is to assess the mechanical properties of aortic aneurysm tissues by measuring acoustic properties by scanning acoustic microscopy (SAM). Twenty-one cases of aortic aneurysm including renal and common iliac aneurysm tissues were surgically excised. Each tissue was fixed by 4% formaldehyde and the specimens were treated as (1) picrosirius red staining for normal and polarized light microscopy, (2) CD68 staining for macrophage detection, and (3) no staining for acoustic microscopy. A specially developed SAM system operating in the frequency range of 100-200 MHz, was employed in the measurement. Images of amplitude and phase are obtained in a field of 2x2 mm. The intima was mainly consisted of degenerated collagen without polarization of picrosirius red staining. Macrophages stained by CD68 were observed near the degenerated collagen fibers. The sound speed was 1567 m/s in the intima, 1576 m/s in the media, 1640 m/s in the adventitia, respectively. Infiltration of macrophages showed higher values of attenuation and sound speed than the surrounding tissues. The sound speed of the intima was significantly lower than our previous measurement of atherosclerotic aorta without aneurismal change. As the tissue elasticity is closely correlated with the sound speed, the elasticity of the intima was considered to be lower in aneurysm tissues. This mechanical weakness may contribute to the expansion of the diameter of the aneurysm. Acoustic microscopy provided important data for assessing tissue mechanical properties of abdominal aneurysm.

Acoustics↗

Addition of rhythm to non-pulsatile circulation.

The development of a rotary blood pump (RP) is desirable as it can be used as a small ventricular assistance device (VAD). However, a RP does not generate any pulse. It may be physiologically better for the patient if the RP could generate a pulse. We have attempted to develop a device that produces a pulse in the RP. Intra-aortic balloon pumping (IABP) is effective in producing a pulse. However, the IABP cannot be implanted inside the body. Therefore, an attempt was made to develop pulse-generating equipment that was not driven by air pressure. The ball screw motor was considered as a possible candidate. In the future, we plan to apply small shape memory alloys. An electrohydraulic system was adopted, and actuator power output was connected to the diaphragm. The diaphragm was placed outside the ventricle. Most RPs developed throughout the world drain blood from the ventricle. The pulse wave should be generated if a pulse is added by the part from which blood is being drawn. In this study, animal experiments were conducted and the output assistance was tested from outside the ventricle. The device operated effectively in the animal experiment. The RP can easily be equipped with this device at the time of performing the implant operation. For a patient with problems of peripheral circulation and the internal organ function, it may prove to be an effective device.

Animal Experimentation↗

Open-loop analysis of transfer characteristics from blood pressure to heart rate using an effectively total artificial heart.

It is desirable for the dynamic behavior of the drive rate of the artificial heart to be as similar as possible to that of the recipient's heart rate (HR) before implantation. This requires a model which can simulate the behavior of HR on the basis of only the information measured with the limited number of approvable implanted sensors. This article provides a linear time series model for explaining the behavior of HR only with aortic pressure and right atrial pressure. This could be obtained from open-loop analysis using a total artificial heart, which was introduced for measuring HR in vivo and for eliminating its effect on blood pressure. The model was identified in a goat equipped with a special biventricular assist device called the effectively total artificial heart (ETAH). The ETAH was introduced to make an open loop and awake situation in the animal with almost intact autonomic nerves, which could enhance the accuracy and reliability of the identification of the model. The adequacy of the proposed model was ascertained in several data sets measured in two goats, which were different from the data set used for identification. Most of the mean estimation errors were less than 3 beats/min and auto-correlation analysis showed approvable statistical appropriateness. However, it was clarified through comparison with the 1/R control method that the proposed model has a few problems still to be solved before its future implementation as an automatic controller of the TAH.

Animals↗

Can personality traits predict pathological responses to audiovisual stimulation?

The "Pockemon shock" is the most famous accident in the history of the broadcasting industry in Japan. Based on the experiences of this unfortunate accident from famous animation program "Pocket Monster", this study focused on the psychology and psychosomatics of the patients. A head-mounted display was used as the three-dimensional image presentation device and "Descent", a free software shooting game, was used as the software. Ten healthy adult male volunteers were used in this experiment after obtaining their informed consent. The oxygen metabolic change in the anterior lobe of the brain was measured by near infrared spectroscopy and recorded on an electrocardiogram. The mental scaling tendency of the object was analyzed using the type A behavior pattern and the hostility scaling. The Cook and Medley hostility (HO) scale from the Minnesota multiphasic personality inventory (MMPI) was also used in this experiment. From this scaling methodology, the paranoid scale, cynicism scale, lie scale, social support quality and social support quantity were calculated. All measured time series data were kept in the normal range, and no fatal arrhythmia or epilepsy were observed during experiments. In some cases, the brain oxygen metabolism may completely differ for the objects of Type A and Type B behavior patterns. On the whole, correlation did not become significant in type A scaling and hostility scaling. In a comparison of the percent changes of the HF in HRV with lie scaling, significant negative correlation was observed. The social support quantity was calculated from Cook and Medley, and significant negative correlations were observed with percent changes of LF/HF in HRV. The lie scale and social support quantity are opposite scaling. The sympathetic nervous system and parasympathetic nervous system have an opposite function also. Therefore, our results showed an interesting phenomenon, when considering the relationship between the autonomic function and the pathophysiological reaction to the audiovisual stimulations. As for the photo sensitive epilepsy, it was reported to be only 5-10% for all patients. Therefore, 90% or more of the cause could not be determined in patients who started a morbid response. The results in this study suggest that the autonomic function was connected to the mental tendency of the objects. By examining such directivity, it is expected that subjects, which show morbid reaction to an audiovisual stimulation, can be screened beforehand.

Acoustic Stimulation↗

Influence of tissue preparation on the acoustic properties of tissue sections at high frequencies.

The purpose of the present study was to clarify the influence of tissue preparation on the high-frequency acoustic properties by comparing the acoustic properties of the formalin-fixed, paraffin-embedded, deparaffinized sections and formalin-fixed, frozen sections for two types of fat-containing renal cancer and fat-free renal oncocytoma using a SAM. There was no significant difference for the sound speed among the clear cell, granular cell renal cancer and oncocytoma in either groups, but the attenuation constant was significantly higher for the frozen than for that of the paraffin section in fat-containing renal cancer. In fat-free oncocytoma, there was no significant difference for the attenuation constant in either group. The data suggest that the fat component, which had been eluted by paraffinization, is stored and the true acoustic properties of the tissue can be measured in frozen section.

Adenocarcinoma, Clear Cell↗

In vivo test of pressure head and flow rate estimation in a continuous-flow artificial heart.

To avoid using sensors with low biocompatibility and low durability in implantable total artificial heart (TAH) systems, the authors previously proposed a new method for estimating instantaneous values of flow rate and pressure head on the basis of voltage, current, and rotational speed in a motor driven centrifugal pump. The previous in vitro experiments showed that the proposed estimator could automatically compensate for the effect of the change in blood viscosity on the estimation accuracy by employing two kinds of autoregressive exogenous models. In this study, validity and reliability of this estimation method were ascertained in an acute animal experiment. In the experiment, two centrifugal blood pumps were implanted into an adult goat as a total artificial heart. Results of estimation were compared with true values when blood viscosity was changed by injecting physiological saline. The results indicated that the system could successfully estimate pressure head by compensating the change of viscosity, although the estimation accuracy of the in vivo estimation was not so high as that of the previous in vitro tests.

Animals↗

Recent progress in artificial organ research at Tohoku University.

Tohoku University has developed various artificial organs over the last 30 years. Pneumatic driven ventricular assist devices with a silicone ball valve have been designed by the flow visualization method, and clinical trials have been performed in Tohoku University Hospital. On the basis of these developments, a pneumatic driven total artificial heart has been developed and an animal experimental evaluation was conducted. The development of artificial organs in Tohoku University has now progressed to the totally implantable type using the transcutaneous energy transmission system with amorphous fibers for magnetic shielding. Examples of implantable systems include a vibrating flow pump for ventricular assist device, an artificial myocardium by the use of shape memory alloy with Peltier elements, and an artificial sphincter for patients with a stoma. An automatic control system for artificial organs had been developed for the ventricular assist devices including a rotary blood pump to avoid suction and to maintain left and right heart balance. Based upon the technology of automatic control algorithm, a new diagnostic tool for evaluating autonomic nerve function has been developed as a branch of artificial organ research and this new machine has been tested in Tohoku University Hospital. Tohoku University is following a variety of approaches aimed at innovation in artificial organs and medical engineering fields.

Academic Medical Centers↗

Chaos attractors of ventricular elastance to evaluate cardiac performance.

Quantitative evaluation of cardiac function is very important in the clinical application of a ventricular assist device. This article reports a new evaluating method of E max, which is the most reliable parameter to evaluate cardiac function. Fluctuation in the E max time series data was evaluated by the nonlinear mathematical analyzing method including chaos and fractal theory. Experimental goats were anesthetized with halothane inhalation, and left ventricular volume and pressure were measured with other hemodynamic parameters to evaluate E max during various drug administrations. E max was evaluated by two methods. One was the conventional pressure volume loop evaluation and the other was the parameter optimization method without left ventricular volume data. As a result, E max evaluated by the parameter optimization method correlated well with the E max with conventional PV curve. Furthermore, interesting results were obtained. There were rhythmical fluctuations in the E max time series data. By the methodology of Takens, E max time series data was embedded into the phase space and a strange attractor was observed. These results may be important when considering E max evaluation during left ventricular assistance.

Animals↗

Outflow control for avoiding atrial suction in a continuous flow total artificial heart.

Continuous flow blood pumps, such as axial flow and centrifugal pumps, have been gaining interest as circulatory devices for total artificial hearts (TAHs) because of their smaller size and simpler structure compared to pulsatile pumps. However, continuous flow pumps are more prone to atrial wall suction than pulsatile pumps are. Sudden increases in flow rate to meet changes in physiological demand, especially in the left pump, often cause atrial wall suction. In this study, a control algorithm to prevent atrial wall suction from occurring in the left atrium by controlling the rotational speed of the right pump, instead of reducing the cardiac output of the left pump, was developed and investigated. The method was tested in a mock circulatory system and in acute animal experiments with adult goats. Two centrifugal pumps were used to totally replace the circulatory function of the natural heart. The cardiac output of each pump was determined independently by a control algorithm running on a computer connected through a serial interface to the pump driving units. Results showed that left atrial wall suction could be prevented using this method, and that the method could be performed simultaneously with physiological control of the artificial heart.

Algorithms↗

Computational flow visualization in vibrating flow pump type artificial heart by unstructured grid.

Computational flow visualization in the casing of vibrating flow pump (VFP) was made for various conditions based on the novel techniques of fluid dynamics. VFP type artificial heart can generate the oscillated flow and can be applied to the left ventricular assist device. Flow pattern of blood in an artificial heart is closely connected to mechanical performance and serious biomechanical problems such as hemolysis and blood coagulation. To effectively design the VFP for a left ventricular assist device, the numerical codes for solving Navier-Stokes equations were developed for three-dimensional blood flow based on the finite volume method. Furthermore, the simulation techniques based on the artificial compressibility method and the unstructured grid were also developed here. The numerical calculations were based on the precise configurations and the flow conditions of the prototype device. From the viewpoint of computational fluid dynamics (CFD), the detailed discussion of flow patterns in the casing of VFP, which were closely connected with hemolysis and blood coagulation, was made and the computational results were visualized by the use of the recent technique of computational graphics. Some useful design data of VFP were presented.

Blood Flow Velocity↗

Non-linear dynamic analysis of hemodynamic parameters in an undulation type artificial heart system.

Undulation pump total artificial heart (UPTAH) is a unique total artificial heart implant (TAH) using an undulation pump that is a continuous blood flow pump. To evaluate the autonomic nerve function mediating the circulation system, we analyzed the hemodynamic parameters during animal experiments with UPTAH using the non-linear mathematical analyzing technique, including chaos and fractal theory. Adult female goats were used for the implantation of UPTAH. The natural heart was replaced with UPTAH under extra-corporal circulation. The conductance- and arterial pressure-based control method (1/R control) was applied on the 5th to 7th post-operative day as the influences of the cardiopulmonary bypass circulation were diagnosed to be terminated. Hemodynamic parameters were recorded on the data recorder, and non-linear mathematical analysis was performed. For the quantitative evaluation of the strange attractor, which was the characteristics of the deterministic chaos, the fractal dimension analysis was carried out. As a result, hemodynamic parameters fluctuated on the time axis and showed fractal characteristics, which were thought to be the characteristics of the deterministic chaos. The reconstructed attractor of the hemodynamics showed various behaviors according to changes in the situation of the goats. These results suggest that non-linear dynamical analysis might be useful in monitoring the circulatory regulatory system in artificial heart circulation.

Animals↗

Non-linear dynamic analysis of hemodynamic behavior during virtual reality immersion.

Several years ago, a famous accident occurred in Japan. Hundreds of children, who were watching a cartoon on television, suddenly complained of spasms and vertigo, and were taken to hospital. In this study, the autonomic nervous system was evaluated during audiovisual stimulation with three dimensional Virtual Reality (VR) imaging. In our previous studies, we designed the diagnosis machine for an autonomic function using multi-parameters, including electrocardiography, arterial blood pressure, respiration and stroke volume as detected by ultrasonic cardiography. Healthy adult volunteers were used in this experiment with their satisfactory informed consent. The three-dimensional content for VR included dinosaur images in a pre-historic scene. The content was projected on a wide screen and volunteers watched an audiovisual screen for about 20 minutes and the 3-D and 2-D images were compared. There was no significant arrhythmia during experiments in both images. No significant alteration was observed in the quantified hemodynamic data during the experiment. Spectral analysis was performed to evaluate the heart rate variability (HRV) during the experiment. LF, HF and LF/HF of HRV were calculated. However, there were no significant changes during the experiment. Significant change was observed in the fractal dimension of the stroke volume during 2-D and 3-D image VR immersion. Our results suggest that a significant response was observed in the autonomic function according to the 2-D or 3-D images. Our study, which aims at safe audiovisual stimulating equipment, must be developed.