Search PubMed⌕ Search

Biomedical subjects

Sharon E Ungersma

Publications and source records attributed to Sharon E Ungersma.

4 recordsLinked to original sources

Magnetic resonance imaging with T1 dispersion contrast.

Prepolarized MRI uses pulsed magnetic fields to produce MR images by polarizing the sample at one field strength (approximately 0.5 T) before imaging at a much lower field (approximately 50 mT). Contrast reflecting the T(1) of the sample at an intermediate field strength is achieved by polarizing the sample and then allowing the magnetization to decay at a chosen "evolution" field before imaging. For tissues whose T(1) varies with field strength (T(1) dispersion), the difference between two images collected with different evolution fields yields an image with contrast reflecting the slope of the T(1) dispersion curve between those fields. Tissues with high protein content, such as muscle, exhibit rapid changes in their T(1) dispersion curves at 49 and 65 mT due to cross-relaxation with nitrogen nuclei in protein backbones. Tissues without protein, such as fat, have fairly constant T(1) over this range; subtracting images with two different evolution fields eliminates signal from flat T(1) dispersion species. T(1) dispersion protein-content images of the human wrist and foot are presented, showing clear differentiation between muscle and fat. This technique may prove useful for delineating regions of muscle tissue in the extremities of patients with diseases affecting muscle viability, such as diabetic neuropathy, and for visualizing the protein content of tissues in vivo.

Algorithms↗

Prepolarized magnetic resonance imaging around metal orthopedic implants.

A prepolarized MRI (PMRI) scanner was used to image near metal implants in agar gel phantoms and in in vivo human wrists. Comparison images were made on 1.5- and 0.5-T conventional whole-body systems. The PMRI experiments were performed in a smaller bore system tailored to extremity imaging with a prepolarization magnetic field of 0.4 T and a readout magnetic field of 27-54 mT (1.1-2.2 MHz). Scan parameters were chosen with equal readout gradient strength over a given field of view and matrix size to allow unbiased evaluation of the benefits of lower readout frequency. Results exhibit substantial reduction in metal susceptibility artifacts under PMRI versus conventional scanners. A new artifact quantification technique is also presented, and phantom results confirm that susceptibility artifacts improve as expected with decreasing readout magnetic field using PMRI. This proof-of-concept study demonstrates that prepolarized techniques have the potential to provide diagnostic cross-sectional images for postoperative evaluation of patients with metal implants.

Adult↗

Three-dimensional prepolarized magnetic resonance imaging using rapid acquisition with relaxation enhancement.

Prepolarized MRI (PMRI) with pulsed electromagnets has the potential to produce diagnostic quality 0.5- to 1.0-T images with significantly reduced cost, susceptibility artifacts, specific absorption rate, and gradient noise. In PMRI, the main magnetic field cycles between a high field (B(p)) to polarize the sample and a homogeneous, low field (B(0)) for data acquisition. This architecture combines the higher SNR of the polarizing field with the imaging benefits of the lower field. However, PMRI can only achieve high SNR efficiency for volumetric imaging with 3D rapid imaging techniques, such as rapid acquisition with relaxation enhancement (RARE) (FSE, TSE), because slice-interleaved acquisition and longitudinal magnetization storage are both inefficient in PMRI. This paper demonstrates the use of three techniques necessary to achieve efficient, artifact-free RARE in PMRI: quadratic nulling of concomitant gradient fields, electromotive force cancelation during field ramping, and phase compensation of CPMG echo trains. This paper also demonstrates the use of 3D RARE in PMRI to achieve standard T(1) and fat-suppressed T(2) contrast in phantoms and in vivo wrists. These images show strong potential for future clinical application of PMRI to extremity musculoskeletal imaging and peripheral angiography.

Algorithms↗

Shim design using a linear programming algorithm.

The advent of open magnetic resonance imaging (MRI) scanners and dedicated MRI scanners tailored to specific body parts has led to an increasing number of noncylindrical MRI scanner geometries, for which noncylindrical gradients and shims are needed. These new scanner geometries are driving the need for fast, flexible shim design methods that can design shim coils for any geometry. A linear programming (LP) algorithm was developed to design minimum-power resistive shim coils on an arbitrary surface. These coils can be designed to produce any order shim field over an arbitrarily shaped target region, which can be placed anywhere within the coil. The resulting designs are relatively sparse and can be readily constructed. This algorithm was used to design and construct a seven-coil cylindrical shim set for a knee imaging magnet with a cylindrical homogeneous region. The algorithm was then used to design shim coils for a biradial head imager with an asymmetrically located spherical target region for brain imaging.

Algorithms↗