Search PubMed⌕ Search

Biomedical subjects

Sergey A Grinshpun

Publications and source records attributed to Sergey A Grinshpun.

At least 19 recordsLinked to original sources

Physical collection efficiency of filter materials for bacteria and viruses.

The purpose of this study was to determine the physical collection efficiency of commercially available filters for collecting airborne bacteria, viruses, and other particles in the 10-900 nm (nanometer) size range. Laboratory experiments with various polytetrafluoroethylene (PTFE), polycarbonate (PC) and gelatin filters in conjunction with Button Inhalable samplers and three-piece cassettes were undertaken. Both biological and non-biological test aerosols were used: Bacillus atrophaeus, MS2, polystyrene latex (PSL), and sodium chloride (NaCl). The B.atrophaeus endospores had an aerodynamic diameter of 900 nm, whereas MS2 virion particles ranged from 10 to 80 nm. Monodisperse 350 nm PSL particles were used as this size was believed to have the lowest filtration efficiency. NaCl solution (1% weight by volume) was used to create a polydisperse aerosol in the 10-600 nm range. The physical collection efficiency was determined by measuring particle concentrations size-selectively upstream and downstream of the filters. The PTFE and gelatin filters showed excellent collection efficiency (>93%) for all of the test particles. The PC filters showed lower collection efficiency for small particles especially <100 nm. Among the tested filters, the lowest collection efficiencies, 49 and 22%, were observed for 1 and 3-microm pore size PC filters at the particle sizes of 47 and 63 nm, respectively. The results indicate that the effect of filter material is more significant for the size range of single virions than for bacteria. The effect of filter loading was examined by exposing filters to mixtures of PSL particles, which aimed at mimicking typical indoor dust levels and size distributions. A 4-h loading did not cause significant change in the physical collection efficiency of the tested filters.

Air Microbiology↗

Estimating sampling frequency in pollen exposure assessment over time.

A time series model was fitted to the pollen concentration data collected in the Greater Cincinnati area for the Cincinnati Childhood Allergy and Air Pollution Study (CCAAPS). A traditional time series analysis and temporal variogram approach were applied to the regularly spaced databases (collected in 2003) and irregularly spaced ones (collected in 2002), respectively. The aim was to evaluate the effect of the sampling frequency on the sampling precision in terms of inverse of standard error of the overall level of mean value across time. The presence of high autocorrelation in the data was confirmed and indicated some degree of temporal redundancy in the pollen concentration data. Therefore, it was suggested that sampling frequency could be reduced from once a day to once every several days without a major loss of sampling precision of the overall mean over time. Considering the trade-offs between sampling frequency and the possibility of sampling bias increasing with larger sampling interval, we recommend that the sampling interval should take values from 3 to 5 days for the pollen monitoring program, if the goal is to track the long-term average.

Air Pollution↗

Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks?

BACKGROUND: Respiratory protection devices are used to protect the wearers from inhaling particles suspended in the air. Filtering face piece respirators are usually tested utilizing nonbiologic particles, whereas their use often aims at reducing exposure to biologic aerosols, including infectious agents such as viruses and bacteria. METHODS: The performance of 2 types of N95 half-mask, filtering face piece respirators and 2 types of surgical masks were determined. The collection efficiency of these respiratory protection devices was investigated using MS2 virus (a nonharmful simulant of several pathogens). The virions were detected in the particle size range of 10 to 80 nm. RESULTS: The results indicate that the penetration of virions through the National Institute for Occupational Safety and Health (NIOSH)-certified N95 respirators can exceed an expected level of 5%. As anticipated, the tested surgical masks showed a much higher particle penetration because they are known to be less efficient than the N95 respirators. The 2 surgical masks, which originated from the same manufacturer, showed tremendously different penetration levels of the MS2 virions: 20.5% and 84.5%, respectively, at an inhalation flow rate of 85 L/min. CONCLUSION: The N95 filtering face piece respirators may not provide the expected protection level against small virions. Some surgical masks may let a significant fraction of airborne viruses penetrate through their filters, providing very low protection against aerosolized infectious agents in the size range of 10 to 80 nm. It should be noted that the surgical masks are primarily designed to protect the environment from the wearer, whereas the respirators are supposed to protect the wearer from the environment.

Air Microbiology↗

Personal exposure to airborne dust and microorganisms in agricultural environments.

Airborne dust and microorganisms are associated with respiratory diseases and increased mortality and morbidity. Farmers are at high risk of exposure to both of these hazards. Very limited information, however, is available on the combined exposures to both hazards on different types of farms. Moreover, most of the previous studies have measured the mass concentration of particles ignoring the particle size. In this study, farmers' exposure to airborne dust and microorganisms was studied using our newly developed personal sampling system. Particle number concentration and size distribution were measured with an optical particle counter. Simultaneously, particles were collected on a filter and analyzed for microorganisms. The field measurements were conducted in animal confinements (swine, poultry, and dairy) and during grain harvesting (corn and soybean). The results show the following average concentrations on the workers' breathing zone: 1.7 x 10(6) to 2.9 x 10(7) particles/m(3) for total dust, 0.9 x 10(3) to 3.9 x 10(4) spores/m(3) for total fungal spores, 0.3 x 10(3) to 3.6 x 10(4)CFU/m(3) for culturable fungal spores, 0.3 x 10(4) to 3.3 x 10(8) CFU/m(3) for culturable bacteria, and limit of detection (LOD) to 2.8 x 10(3) CFU/m(3) for culturable actinomycetes in animal confinements. The respective concentrations were 4.4 x 10(6) to 5.8 x 10(7) particles/m(3), 3.4 x 10(4) to 6.1 x 10(6) spores/m(3), 8.2 x 10(4) to 7.4 x 10(6) CFU/m(3), 0.4 x 10(5) to 1.4 x 10(6) CFU/m(3), and LOD to 2.6 x 10(4) CFU/m(3) during grain harvesting. The highest contribution of large particles (3-10 microm) in total particles was found during grain harvesting, whereas the size distribution was dominated by smaller particles (< 3 microm) in animal confinements. High fraction (up to 37%) of particles between 2-10 microm was found to be fungal spores. The results indicate that an increase in the concentration of large dust particles (2-10 microm) during grain harvesting was partially attributed to the increase in the concentration of the fungal spores. Overall, the combined exposure to airborne dust and microorganisms was found to be more severe during harvesting than in animal confinements.

Aerosols↗

Assessment of fungal contamination in moldy homes: comparison of different methods.

In an effort to better understand the relationship between different fungal sampling methods in the indoor environment, four methods were used to quantify mold contamination in 13 homes with visible mold. Swab, fungal spore source strength tester (FSSST), and air samples (total of 52 samples) were analyzed using both the microscopic (total spore count) and culture-based (CFU count) enumeration techniques. Settled dust samples were analyzed for culturable fungi only, as the microscopic enumeration was restricted by the masking effect. The relationships between the data obtained with the different sampling methods were examined using correlation analysis. Significant relationships were observed between the data obtained from swab and FSSST samples both by the total counting (r = 0.822, p < 0.05) and by the CFU counting (r = 0.935, p < 0.01). No relationships were observed between air and FSSST samples or air and settled dust samples. Percentage culturability of spores for each sampling method was also calculated and found to vary greatly for all three methods (swab: 0.03% to 63%, FSSST: 0.1% to > 100%, air: 0.7% to 79%). These findings confirm that reliance on one sampling or enumeration method for characterization of an indoor mold source might not provide an accurate estimate of fungal contamination of a microenvironment. Furthermore, FSSST sampling appears to be an effective measurement of a mold source in the field, providing an upper bound estimate of potential mold spore release into the indoor air. Because of the small sample size of this study, however, further research is needed to better understand the observed relationships in this study.

Air Microbiology↗

Specific fungal exposures, allergic sensitization, and rhinitis in infants.

Indoor air quality has become increasingly important as we live in a society where the majority of our time is spent indoors. Specific attention has been drawn to airborne fungal spores as a factor affecting indoor air quality. This study targeted shortcomings of other studies by utilizing long-term air sampling and total fungal spore enumeration to determine associations between health outcomes and fungal spore concentrations. Infants (n = 144) were clinically evaluated and had skin prick tests (SPT) for 17 allergens. Airborne fungal spores were collected using a Button Personal Inhalable Sampler (SKC Inc.) for 48 h at a flow rate of 4 l/min. Sampling was conducted in the spring (March-May) or fall (August-October) in 2003-2004. Fungal spores were analyzed using microscopy-based total counting and identified to the genus/group level. Total spore and individual genus concentrations were analyzed for associations with rhinitis and positive SPT results. Overall, concentrations varied widely, between <2 and 2294 spores/m(3). While no relationship was observed between SPT(+) and total fungal counts, several significant associations were found when analysis was conducted on the various fungal genera and health outcomes. Positive associations were obtained between: Basidiospores and rhinitis (p < 0.01), Penicillium/Aspergillus and SPT(+) to any allergen (p < 0.01), and Alternaria and SPT(+) to any allergen (p < 0.01). Inverse associations were found between: Cladosporium and SPT(+) to any allergen (p < 0.05), and Cladosporium and SPT(+) to aeroallergens (p < 0.05). This study indicates that health outcome may vary by fungal genera; some fungal types may have sensitizing effects while others may have a beneficial role.

Air Microbiology↗

Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles.

Protection of the human respiratory system from exposure to nanoparticles is becoming an emerging issue in occupational hygiene. The potential adverse health effects associated with particles of approximately 1-100 nm are probably greater than submicron or micron-sized particles. The performance of two models of N95 half-facepiece-filtering respirators against nano-sized particles was evaluated at two inhalation flow rates, 30 and 85 l min(-1), following a manikin-based protocol. The aerosol concentration was measured outside and inside the facepiece using the Wide-Range Particle Spectrometer. Sodium chloride particles, conventionally used to certify N-series respirators under NIOSH 42 CFR 84 regulations, were utilized as the challenge aerosol. The targeted particle sizes ranged from 10 to 600 nm, although the standard certification tests are performed with particles of approximately 300 nm, which is assumed to be the most penetrating size. The results indicate that the nanoparticle penetration through a face-sealed N95 respirator may be in excess of the 5% threshold, particularly at high respiratory flow rates. Thus, N95 respirators may not always provide the expected respiratory protection for workers. The highest penetration values representing the poorest respirator protection conditions were observed in the particle diameter range of approximately 30-70 nm. Based on the theoretical simulation, we have concluded that for respirators utilizing mechanical filters, the peak penetration indeed occurs at the particle diameter of approximately 300 nm; however, for pre-charged fiber filters, which are commonly used for N95 respirators, the peak shifts toward nano-sizes. This study has confirmed that the neutralization of particles is a crucial element in evaluating the efficiency of a respirator. The variability of the respirator's performance was determined for both models and both flow rates. The analysis revealed that the coefficient of variation of the penetration ranged from 0.10 to 0.54 for particles of 20-100 nm in diameter. The fraction of N95 respirators for which the performance test at 85 l min(-1) demonstrated excessive (>5%) penetration of nanoparticles was as high as 9/10. The test results obtained in a relatively small (0.096 m(3)) test chamber and in a large (24.3 m(3)) walk-in chamber were found essentially the same, thus, suggesting that laboratory-based evaluations have a good potential to adequately represent the respirator field performance.

Aerosols↗

Correlation of ambient inhalable bioaerosols with particulate matter and ozone: a two-year study.

In this study, we have examined the relationships between the concentrations of ambient inhalable airborne fungi and pollen with PM10, PM2.5, ozone, organic carbon, selected trace metals (cadmium, copper, lead, and zinc), temperature, and relative humidity. The database was collected in Cincinnati, Ohio, USA, during two consecutive years. Measurements of all environmental variables were performed at the same site continuously 5 days a week except during winter months. The airborne concentrations of biological and non-biological pollutants ranged as follows: total fungi: 184-16 979 spores m(-3); total pollen: 0-6692 pollen m(-3); PM10: 6.70-65.38 microg m(-3); PM2.5: 5.04-45.02 microg m(-3); and ozone: 2.54-64.17 ppb. Higher levels of total inhalable fungi and particulate matter were found during fall and summer months. In contrast, total pollen concentration showed elevated levels in spring. Peak concentrations of ozone were observed during summer and beginning of fall. Our study concluded that several types of inhalable airborne fungi and pollen, particulate matter, and ozone could be positively correlated as a result of the atmospheric temperature influence.

Aerosols↗

Sampling over time: developing a cost effective and precise exposure assessment program.

Studies requiring ambient exposure assessments invariably ask: How often should measurements be taken? Answer to such questions is dictated by budgetary considerations as well as spatial and temporal variability in the data. For example, do we obtain measurements during all seasons, all months within seasons, weeks within months and days within weeks? On one hand, we can obtain a one-time snapshot sample and regard it as representing the "true" mean exposure. On the other hand, we may obtain a large number of measurements over time and then average these in order to represent this "true" mean exposure. The former estimate is the least expensive but may also be the least precise while the latter, may be very precise but prohibitively costly. In this paper, we demonstrate how a pilot study can be undertaken with a potentially promising and feasible sampling plan for the full-scale study. By applying the statistical methodology of variance component analysis (VCA) to the pilot study data and exploiting mathematical relationship between the variance of the overall mean exposure and posited variance components, we can develop a sampling design with decreased sampling costs and/or increased precision of the mean exposure. Our approach was applied to determine sampling design choices for an on-going study that aimed at assessing ambient particulate matter exposure. We conclude that a pilot study followed by the VCA analysis may often lead to sampling design choices that offer considerable cost savings and, at the same time, promise to provide relatively precise estimates of the mean exposure for the subsequent full-scale study.

Analysis of Variance↗

The effect of filter material on bioaerosol collection of Bacillus subtilis spores used as a Bacillus anthracis simulant.

The objective of this study was to determine filter materials and extraction methods that are appropriate to use for environmental sampling of B. anthracis. Four types of filters were tested: mixed cellulose ester (MCE) with a pore size of 3 microm, polytetrafluoroethylene (PTFE) with pore sizes of 1 and 3 microm, and gelatin with a pore size of 3 microm. Bacillus subtilis var. niger endospores (also known as Bacillus globigii[BG]) were used as a surrogate for B. anthracis. Endospores were collected into Button Inhalable Aerosol Samplers with sampling times of 15 minutes, 1 hour, and 4 hours. Physical collection efficiency was determined by measuring upstream and downstream B. subtilis concentrations with an optical particle counter. Vortexing with ultrasonic agitation and vortexing with shaker agitation extraction methods were evaluated. The MCE, 1 microm PTFE, and gelatin filters provided physical collection efficiencies of 94% or greater. The 3 microm PTFE filter showed inconsistent physical efficiency characteristics between filters. Epifluorescence microscopic analysis of the gelatin filter extraction fluid revealed the presence of contamination by non-culturable bacteria. Mean differences for microbial culturability were not statistically significant for filter materials and extraction methods. However, the vortexing with shaker agitation extraction method resulted in higher total microbial counts in the extraction fluids for MCE and 1 microm PTFE filters when compared to vortexing with ultrasonic agitation. In summary, the MCE and 1 microm PTFE filters in combination with vortexing and shaker extraction demonstrated the best performance for the filter collection and extraction of BG spores.

Aerosols↗

Laboratory and field evaluation of a new personal sampling system for assessing the protection provided by the N95 filtering facepiece respirators against particles.

OBJECTIVES: We have recently developed a new personal sampling system for the real-time measurement of the protection provided by respirators against airborne dust and micro-organisms. The objective of this study was to evaluate the performance characteristics of the new sampling system in both laboratory and field conditions. METHODS: The measurements were conducted using the N95 filtering facepiece respirators and the newly developed personal sampling system put on a manikin (laboratory study) or donned by a human subject (laboratory and field studies). Two inhalation flow rates (0 and 40 l min(-1)) in conjunction with the sampling flow rate (10 l min(-1)) were tested in the manikin-based experiments to investigate the effects of the leak location (nose, cheek and chin) and the depth of the sampling probe (0, 5, 10 and 15 mm) within the respirator. The effect of human activity on the protection factor was evaluated using a variety of head movements and breathing patterns when a human subject wore the respirator in a room-size laboratory test chamber. The field study was conducted during corn harvesting with a respirator worn by a human subject on a combine. RESULTS: There was no significant difference in the protection factors for different leak locations, or for sampling probe depths, when the inhalation rate was 0 l min(-1). For the inhalation rate of 40 l min(-1), the protection factors for nose leaks were higher than those for chin and cheek leaks. Furthermore, the protection factor was the lowest and showed the least variation when the sampling probe depth was equal to 0 mm (imbedded on the respirator surface). Human subject testing showed that the grimace maneuver decreased the protection factor and changed the original respirator fit. The protection factor during breath holding was lower than that found during inhalation and exhalation. Field results showed greater variation than laboratory results. CONCLUSIONS: The newly designed personal sampling system efficiently detected the changes in protection factors in real time. The sampling flow was least affected by the inhalation flow when the sampling probe was imbedded on the respirator surface. Leak location, breathing patterns and exercises did affect the measurement of the protection factors obtained using an N95 filtering facepiece respirator. This can be attributed to the differences in the in-mask airflow dynamics contributed by the leak, filter material, sampling probe and inhalation. In future studies, it would be beneficial if the laboratory data could be integrated with the field database.

Equipment Design↗

Is it traffic type, volume, or distance? Wheezing in infants living near truck and bus traffic.

BACKGROUND: Previous studies of air pollution have not examined the association between exposure to varying types, distance, and amounts of traffic and wheezing in very young infants. OBJECTIVE: We sought to determine the relationship between types of traffic, traffic volume, and distance and wheezing among infants less than 1 year of age. METHODS: A geographic information system and a classification scheme were developed to categorize infants enrolled in the study as living near moving truck and bus traffic (highway >50 miles per hour, >1000 trucks daily, <400 m), stop-and-go truck and bus traffic (<50 miles per hour, <100 m), or unexposed and not residing near either. Symptom data were based on health questionnaires administered to parents when the infants were 6 months of age and monthly health diaries. RESULTS: Infants living very near (<100 m) stop-and-go bus and truck traffic had a significantly increased prevalence of wheezing (adjusted odds ratio, 2.50; 95% CI, 1.15-5.42) when compared with unexposed infants. The prevalence of wheezing among nonwhite infants was at least twice that of white infants, regardless of exposure. Infants living less than 400 m from a high volume of moving traffic, however, did not have an increased prevalence of wheezing. CONCLUSION: These results suggest that the distance from and type of traffic exposures are more significant risk factors than traffic volume for wheezing in early infancy.

Environmental Exposure↗

Respiratory protection provided by N95 filtering facepiece respirators against airborne dust and microorganisms in agricultural farms.

A new system was used to determine the workplace protection factors (WPF) for dust and bioaerosols in agricultural environments. The field study was performed with a subject wearing an N95 filtering facepiece respirator while performing animal feeding, grain harvesting and unloading, and routine investigation of facilities. As expected, the geometric means (GM) of the WPFs increased with increasing particle size ranging from 21 for 0.7-1 microm particles to 270 for 5-10 microm particles (p < 0.001). The WPF for total culturable fungi (GM = 35) was significantly greater than for total culturable bacteria (GM = 9) (p = 0.01). Among the different microorganism groups, the WPFs of Cladosporium, culturable fungi, and total fungi were significantly correlated with the WPFs of particles of the same sizes. As compared with the WPFs for dust particles, the WPFs for bioaerosols were found more frequently below 10, which is a recommended assigned protection factor (APF) for N95 filtering facepiece respirators. More than 50% of the WPFs for microorganisms (mean aerodynamic diameter < 5 microm) were less than the proposed APF of 10. Even lower WPFs were calculated after correcting for dead space and lung deposition. Thus, the APF of 10 for N95 filtering facepiece respirators seems inadequate against microorganisms (mean aerodynamic size < 5 microm). These results provide useful pilot data to establish guidelines for respiratory protection against airborne dust and microorganisms on agricultural farms. The method is a promising tool for further epidemiological and intervention studies in agricultural and other similar occupational and nonoccupational environments.

Agriculture↗

Evaluation and optimization of an urban PM2.5 monitoring network.

The objective of this study was to evaluate the PM(2.5) monitoring network established in the Greater Cincinnati and Northern Kentucky metropolitan area for measuring the 24 h integrated PM(2.5) concentration, as well as-at selected sites-hourly PM(2.5) concentration and 24 h integrated PM(2.5) speciation. The data collected during three years at 13 measurement sites were analyzed for spatial and temporal variations. It was found that both daily and hourly concentrations of PM(2.5) have low spatial variation due to a regional influence of secondary ammonium sulfate. In contrast, the trace element concentrations had high spatial variation. Seasonal variation accounted for most of the total temporal variation (60%), while yearly, monthly, weekly and daily variations were lower. The variance components and cluster analyses were applied to optimize the number of sites for measuring the 24 h PM(2.5) concentration. It was found that the 13-site network may be optimized by reducing the number of sites to 8, which would result in a relative precision reduction of 9% and a relative cost reduction of 36%. At the same time, the data suggest that the spatial resolution of speciation monitors and real-time PM(2.5) mass monitors should be increased to better represent spatial and temporal variations of the markers of local air pollution sources.

Air Pollutants↗

Fungal spore source strength tester: laboratory evaluation of a new concept.

The airborne fungal spore concentration measured with air samplers during specific time intervals does not always adequately represent the maximum spore concentration levels, because of the sporadic nature of spore release. Hence, a reliable method is needed to directly assess the indoor fungal sources with respect to their spore aerosolization potential. In this study, the newly developed fungal spore source strength tester (FSSST), which aerosolizes spores from growth surfaces and samples the airborne fungi into a bioaerosol sampler, was evaluated in the laboratory. The FSSST's operational flow rates of 30 and 12.5 l/min were tested. The fungal spores released from moldy surfaces were measured with an optical particle counter. Simultaneously, the spores were collected by a bioaerosol sampler: either with a 37-mm filter cassette or with the BioSampler. Three material types, ceiling tile, gypsum board and plastic sheet coated with agar, were tested after they were inoculated with the fungus Aspergillus versicolor. In addition, gypsum board naturally contaminated with various fungi (obtained from a mold-problem home) was tested in the laboratory using the FSSST. In all three laboratory-inoculated materials, the release rate of A. versicolor was found to be higher when the FSSST operated at 30 l/min than at 12.5 l/min. Nevertheless, even at 12.5 l/min the number of spores aerosolized from the source during 10 min was found sufficient to reflect the highest level of release that may occur in indoor environments. At 12.5 l/min, the release rate of A. versicolor during the first 10-min period was (23.9 +/- 17.7)x10(4) cm(-2) for ceiling tile, (1.3 +/- 0.3)x10(4) cm(-2) for gypsum board and (0.13 +/- 0.08)x10(4) cm(-2) for agar surface (based on the samples collected with the BioSampler). The spore release rate was higher during the first 10 min than during the second 10 min of the FSSST application. It was observed that the particles aerosolized from the A. versicolor culture included spore aggregates and single spores, as well as mycelial fragments. Overall, 0.6 +/- 0.3% of spores detected on 1 cm2 of ceiling tile inoculated with A. versicolor were aerosolized during the 10-min source testing. The respective number was 9.2 +/- 1.0% for the laboratory-inoculated gypsum board, 0.002 +/- 0.001% for the laboratory-inoculated plastic covered with agar and 1.8 +/- 0.2% for naturally contaminated gypsum board. Our data suggest that the FSSST provides very favorable conditions for the spore aerosolization and thus can be used in the field to assess the maximum potential spore release from a fungal source.

Aerosols↗

Assessment of electrical charge on airborne microorganisms by a new bioaerosol sampling method.

Bioaerosol sampling is necessary to monitor and control human exposure to harmful airborne microorganisms. An important parameter affecting the collection of airborne microorganisms is the electrical charge on the microorganisms. Using a new design of an electrostatic precipitator (ESP) for bioaerosol sampling, the polarity and relative strength of the electrical charges on airborne microorganisms were determined in several laboratory and field environments by measuring the overall physical collection efficiency and the biological collection efficiency at specific precipitation voltages and polarities. First, bacteria, fungal spores, and dust dispersed from soiled carpets were sampled in a walk-in test chamber. Second, a simulant of anthrax-causing Bacillus anthracis spores was dispersed and sampled in the same chamber. Third, bacteria were sampled in a small office while four adults were engaged in lively discussions. Fourth, bacteria and fungal spores released from hay and horse manure were sampled in a horse barn during cleanup operations. Fifth, bacteria in metalworking fluid droplets were sampled in a metalworking simulator. It was found that the new ESP differentiates between positively and negatively charged microorganisms, and that in most of the tested environments the airborne microorganisms had a net negative charge. This adds a signature to the sampled microorganisms that may assist in their identification or differentiation, for example, in an anti-bioterrorism network.

Aerosols↗

Assessment of human exposure to airborne fungi in agricultural confinements: personal inhalable sampling versus stationary sampling.

Accurate exposure assessment to airborne fungi in agricultural environments is essential for estimating the associated occupational health hazards of workers. The objective of this pilot study was to compare personal and stationary sampling for assessing farmers' exposure to airborne fungi in 3 different agricultural confinements located in Ohio, USA (hog farm, dairy farm, and grain farm), using Button Personal Inhalable Samplers. Personal exposures were measured with samplers worn by 3 subjects (each carrying 2 samplers) during 3 types of activities, including animal feeding in the hog farm, cleaning and animal handling in the dairy farm, and soybean unloading and handling in the grain farm. Simultaneously, the stationary measurements were performed using 5 static Button Samplers and 1 revolving Button Sampler. The study showed that the total concentration of airborne fungi ranged from 1.4 x 10(4)-1.2 x 10(5) spores m(-3) in 3 confinements. Grain unloading and handling activity generated highest concentrations of airborne fungi compared to the other 2 activities. Prevalent airborne fungi belonged to Cladosporium, Aspergillus/Penicillium, Ascospores, smut spores, Epicoccum, Alternaria, and Basidiospores. Lower coefficients of variations were observed for the fungal concentrations measured by personal samplers (7-12%) compared to the concentrations measured by stationary samplers (27-37%). No statistically significant difference was observed between the stationary and personal measurement data for the total concentrations of airborne fungi (p > 0.05). Revolving stationary and static stationary Button Samplers demonstrated similar performance characteristics for the collection of airborne fungi. This reflects the low sensitivity of the sampler's efficiency to the wind speed and direction. The results indicate that personal exposure of agricultural workers in confinements may be adequately assessed by placing several Button Samplers simultaneously operating in a static stationary mode throughout the work site.

Agriculture↗

Release of Streptomyces albus propagules from contaminated surfaces.

The release of Streptomyces albus propagules from contaminated agar and ceiling tile surfaces was studied under controlled environmental conditions in a newly developed aerosolization chamber. The experiments revealed that both spores and cell fragments can be simultaneously released from the colonized surface by relatively gentle air currents of 0.3 ms(-1). A 100 x increase of the air velocity can result in a 50-fold increase in the number of released propagules. The aerosolization rate depends strongly on the type and roughness of the contaminated surface. Up to 90% of available actinomycete propagules can become airborne during the first 10 min of the release process. Application of vibration to the surface did not reveal any influence on the aerosolization process of S. albus propagules under the tested conditions. This study has shown that propagules in the fine particle size range can be released in large amounts from contaminated surfaces. Measurement of the number of S. albus fragments in the vicinity of a contaminated area, as an alternative to conventional air or surface sampling, appears to be a promising approach for quantitative exposure assessment.

Aerosols↗