Search PubMed⌕ Search

Biomedical subjects

Seiki Hamada

Publications and source records attributed to Seiki Hamada.

28 records · Page 2Linked to original sources

Comparison of quality of multiplanar reconstructions and direct coronal multidetector CT scans of the lung.

OBJECTIVE: The purpose of this study was to compare the quality of coronal multiplanar reconstructions with the quality of direct coronal thin-section multidetector CT (MDCT) scans. MATERIALS AND METHODS: Axial multidetector CT (MDCT) scans were obtained through the entire lung in 10 normal autopsy lung specimens using an MDCT scanner. Four protocols were used: 0.5-mm collimation with a 0.5-mm reconstruction interval; 0.5-mm collimation with a 0.3-mm reconstruction interval; 1-mm collimation with a 0.5-mm reconstruction interval; and 2-mm collimation with a 1-mm reconstruction interval. Multiplanar reconstruction images with 0.5-mm slice thickness were obtained from the four types of data sets. Direct coronal thin-section CT of the same 10 autopsy lung specimens was performed using 0.5-mm scan collimation, a 0.3-mm reconstruction interval, a 25.6-cm field of view, and a 512 x 512 matrix. Two independent observers compared the image quality of each of the four coronal multiplanar reconstruction sets with that of direct coronal thin-section CT scans. The observers analyzed visualization of anatomic features and artifacts. RESULTS: The total image quality of the multiplanar reconstructions obtained from 0.5-mm collimation data with or without 0.3-mm overlapping reconstruction was equal to that of direct coronal thin-section CT scans in all 20 interpretations. The image quality of multiplanar reconstruction images from 0.5-mm collimation data either with or without overlapping reconstruction was superior to multiplanar reconstruction images obtained from 1- or 2-mm collimation scans (p < 0.01, Fisher's exact test). Stairstep artifacts in multiplanar reconstructions using 0.5-mm collimation without overlapping reconstruction were equal to those with overlapping reconstruction and were fewer than those on 1- or 2-mm collimation (p < 0.01, Mann-Whitney U test). CONCLUSION: The image quality of coronal multiplanar reconstructions from isotropic voxel data obtained using 0.5-mm collimation, with or without overlapping reconstruction, is similar to that of direct coronal thin-section CT scans.

Aged↗

Using the World Health Organization Classification of thymic epithelial neoplasms to describe CT findings.

OBJECTIVE: Our purpose was to assess the CT features of various subtypes of thymic epithelial neoplasms on the basis of the 1999 World Health Organization classification. MATERIALS AND METHODS: Thymic epithelial neoplasms in 53 patients who underwent thymectomy were retrospectively assessed histologically according to the 1999 World Health Organization classification. Type A and B neoplasms correspond to thymomas and type C, to thymic carcinoma. The study included four patients with type A, 14 with type AB, nine with type B1, 14 with type B2, four with type B3, and eight with type C epithelial tumors. Two observers independently assessed the CT scans without knowledge of the histologic findings. RESULTS: Type A tumors were more likely to have smooth contours on CT (4/4, 100%) and round shapes (3.5/4, 88%) than any other type of thymic epithelial tumor (all, p < 0.05). Type C tumors had a higher prevalence of irregular contours (6/8, 75%) than any other type of thymic epithelial tumor (all, p < 0.05). Calcification was more frequently seen in type B1 (4/9, 44%), type B2 (8.5/14, 61%), and type B3 (3/4, 75%) tumors than in type AB (2/14, 14%) and type C (0.5/8, 6%) tumors (all, p < 0.05). CONCLUSION: Smooth contours and a round shape are most suggestive of type A thymic epithelial tumor, whereas irregular contours are most suggestive of type C tumor. Calcification is suggestive of type B tumors. CT is of limited value, however, in differentiating type AB, B1, B2, and B3 tumors.

Adult↗

[Technical application of three-dimensional visualization and measurement for breast cancer using multidetector-row CT scanner].

This paper describes an integrated methodology that addresses the operation of 3D imaging and measurement for the diagnosis and surgical operation of breast cancer. The main system for breast CT imaging used a multi-slice CT scanner and 3D-workstation. The clinical sequence was performed in three phases with non-contrast and biphasic contrast-enhanced studies that were performed with multi-slice helical CT scanning. Acquired DICOM images were directly sent to the 3D workstation that implemented our developed functions. Four types of transfer functions (mammary skin, vessel, lymph node, and tumor) were set based on region-of-interest (ROI) measurements. After that, two types of segmentation were prepared with volumetry and measurement of the size of breast cancer. Batch processing for 3D visualization and the measurement of breast tumors was helpful for diagnosis and surgical planning.

Breast Neoplasms↗

[Visualization by dynamic CT: invention of 2D-CT chronogram].

Dynamic computed tomography is one of the methods used for the functional analysis of blood flow information. We devised a simple method of visualization for dynamic CT. Re-sliced images were stacked as multi-slice images for the different acquisition times to show a continuous spatial arrangement with dynamic data. Images processed into re-sliced images termed 2D-CT Chronograms were observed in many directions and were useful for comprehending the blood flow function of the target organ. Time-density curves with motion dependency and color displays similar to those of ultrasound images are easily acquired from the 2D-Chronogram. We introduce some clinical applications of the 2-D Chronogram.

Contrast Media↗

[Evaluation of the retrospective ECG-gated helical scan using half-second multi-slice CT: motion phantom study for volumetry].

ECG synchronized technique on multi-slice CT provide the thinner (less 2 mm slice thickness) and faster (0.5sec/rotation) scan than that of the single detector CT and can acquire the coverage of the entire heart volume within one breath-hold. However, temporal resolution of multi-slice CT is insufficient on practical range of heart rate. The purpose of this study was to evaluate the accuracy of volumetry on cardiac function measurement in retrospective ECG-gated helical scan. We discussed the influence of the degradation of image quality and limitation of the heart rate in cardiac function measurement (volumetry) using motion phantom.

Electrocardiography↗

Quantitative analysis for computed tomography findings of various diffuse lung diseases using volume histogram analysis.

OBJECTIVES: : The aim of this study was to achieve the quantitative analysis of the characteristic computed tomography (CT) findings and course of interstitial pneumonia using the volume histogram method. METHODS: : Contrast (CNT), variance (VAR), and entropy (EPY) values from whole-lung volume data were compared between normal lungs and 5 diseases that have characteristic CT findings. Thirteen cases with nonspecific interstitial pneumonia (NSIP) were evaluated before and after treatment. RESULTS: : In cases with thickening of the bronchovascular bundles and interlobular thickening, ground-glass attenuation, airspace consolidation, and honeycombing, the values of VAR and EPY were greater than those in the normal cases (P < 0.05). In the cases with NSIP, the CNT value after treatment was significantly greater and the values of VAR and EPY after treatment were significantly lower than those before treatment (P < 0.05). CONCLUSIONS: : Volume histogram analysis is a promising method for the evaluation of diffuse lung diseases and the effectiveness of treatment.

Adolescent↗

Pathologic subgroups of nonspecific interstitial pneumonia: differential diagnosis from other idiopathic interstitial pneumonias on high-resolution computed tomography.

OBJECTIVE: To determine whether the subtypes of nonspecific interstitial pneumonia (NSIP) could be differentiated from other idiopathic interstitial pneumonias (IIPs) on the basis of findings on high-resolution computed tomography (CT). METHODS: Two observers evaluated the high-resolution CT findings in 90 patients with IIPs. The patients included 36 with NSIP, 11 with usual interstitial pneumonia (UIP), 8 with cryptogenic organizing pneumonia (COP), 10 with acute interstitial pneumonia (AIP), 14 with desquamative interstitial pneumonia (DIP) or respiratory bronchiolitis-associated interstitial lung disease (RB-ILD), and 11 with lymphoid interstitial pneumonia (LIP). The NSIP cases were subdivided into group 1 NSIP (n = 6), group 2 NSIP (n = 15), and group 3 NSIP (n = 15). RESULTS: Observers made a correct diagnosis with a high level of confidence in 65% of NSIP cases, 91% of UIP cases, 44% of COP cases, 40% of AIP cases, 32% of DIP or RB-ILD cases, and 82% of LIP cases. Group 1 NSIP was misdiagnosed as AIP, DIP or RB-ILD, and LIP in 8.3% of patients, respectively. Group 2 NSIP was misdiagnosed as COP in 10% of patients, LIP in 6.7%, AIP in 3.3%, and DIP or RB-ILD in 3.3%. Group 3 NSIP was misdiagnosed as UIP in 6.7% of patients, COP in 6.7%, and DIP or RB-ILD in 3.3%. CONCLUSIONS: In most patients, NSIP can be distinguished from other IIPs based on the findings on high-resolution CT. Only a small percentage of patients with predominantly fibrotic NSIP (group 3 NSIP) show overlap with the high-resolution CT findings of UIP.

Adult↗

Coronal multiplanar reconstruction view from isotropic voxel data sets obtained with multidetector-row CT: assessment of detection and size of mediastinal and hilar lymph nodes.

OBJECTIVE: To assess the detection and size of mediastinal and hilar lymph nodes by multiplanar reconstruction (MPR) view from isotropic voxel data sets obtained with multidetector-row computed tomography (MDCT). MATERIALS AND METHODS: Thin-section CT of 27 patients with mediastinal or hilar lymph node swelling was obtained with a 25.6-cm FOV, 512 x 512 matrix, and two protocols: A) 0.5-mm collimation, 0.3-mm interval, and B) 2-mm collimation, 1-mm interval. MPR views with a 0.5-mm slice thickness were obtained from these two data sets. Postcontrast axial CT used 5-mm collimation (set C). Two observers evaluated the presence and cranio-caudal length of swollen lymph nodes. Two other board-certified chest radiologists evaluated all three sets and established a gold standard by consensus. RESULTS: The accuracy of detection was 76%, 73%, and 68% for sets A, B, and C, respectively. There was a significant difference between sets A and C (McNemar's test: p<0.05) but not between sets A and B or B and C (p>0.05). The cranio-caudal length of lymph nodes was significantly correlated with the gold standard only in set A (Pearson's correlation coefficient: r=0.53, p<0.05). CONCLUSION: Non-contrast enhanced coronal MPR views constructed from isotropic voxel data sets may be substituted for axial enhanced CT for the evaluation of mediastinal and hilar lymph nodes.

Adolescent↗

Coronal multiplanar reconstruction view from whole lung thin-section CT by multidetector-row CT: determination of malignant or benign lesions and differential diagnosis in 68 cases of solitary pulmonary nodule.

PURPOSE: The purpose of this study was to evaluate the usefulness of the coronal multiplanar reconstruction (MPR) view in comparison with transverse helical thin-section CT for both the determination of malignant or benign lesions and the differential diagnosis of solitary pulmonary nodules. MATERIALS AND METHODS: Sixty-eight cases of pathologically proved solitary pulmonary nodule less than 3 cm in diameter were enrolled in this study. For the routine study, transverse helical thin-section CT (1.25 mm collimation, FOV 20 cm) covering the areas with solitary pulmonary nodules as well as whole lung helical thin-section CT (2.5 mm collimation, 1.25 mm reconstruction interval, FOV 34.5 cm, pitch 6:1, high-spatial frequency algorithm) were scanned with a multidetector-row CT (MDCT) scanner. From the whole lung thin-section CT data, coronal MPR views (2.5 mm slice thickness) were reconstructed on a workstation. ROC analysis was used for an observer performance study, in which three observers indicated their confidence level for the determination of malignant or benign lesion for the nodules by means of transverse thin-section CT and coronal MPR. In addition, the observers recorded appropriate disease entities as the final diagnosis of each case. Accuracies of the final diagnosis based on the two sets of images were compared with McNemer' s test. RESULTS: In terms of the determination of malignant or benign lesion, there was no significant difference between the two sets of images (coronal MPR and transverse thin-section CT; mean Az=0.853 and 0.854, respectively). In addition, accuracy of the final diagnosis based on coronal MPR views (74%) was almost equal to that based on transverse thin-section CT (71%) (p=0.3). CONCLUSIONS: The diagnostic efficacy of the coronal MPR view is comparable to that of transverse thin-section CT for the evaluation of solitary pulmonary nodules.

Adult↗

Evaluation of major aortopulmonary collateral arteries (MAPCAs) using three-dimensional CT angiography: two case reports.

Pulmonary atresia (PA) and ventricular septal defect (VSD) are usually associated with major aortopulmonary collateral arteries (MAPCAs). Preoperative evaluation of MAPCAs is essential for effective planning of unifocalization. Multidetector-row computed tomography (MDCT) with three-dimensional volume rendering (3D-VR) demonstrates MAPCAs as well as conventional angiography. We report two cases of PA and VSD associated with MAPCAs examined pre- and postoperatively by means of angiography and MDCT with the 3D-VR technique. MDCT with the 3D-VR technique had the potential to elucidate all MAPCAs demonstrated by invasive angiography. This technique is useful with preoperative conventional angiography as a standard examination for the planning of staged surgery.

Adult↗