Search PubMed⌕ Search

Biomedical subjects

Sayan D Pathak

Publications and source records attributed to Sayan D Pathak.

5 recordsLinked to original sources

Parametric shape modeling using deformable superellipses for prostate segmentation.

Automatic prostate segmentation in ultrasound images is a challenging task due to speckle noise, missing boundary segments, and complex prostate anatomy. One popular approach has been the use of deformable models. For such techniques, prior knowledge of the prostate shape plays an important role in automating model initialization and constraining model evolution. In this paper, we have modeled the prostate shape using deformable superellipses. This model was fitted to 594 manual prostate contours outlined by five experts. We found that the superellipse with simple parametric deformations can efficiently model the prostate shape with the Hausdorff distance error (model versus manual outline) of 1.32 +/- 0.62 mm and mean absolute distance error of 0.54 +/- 0.20 mm. The variability between the manual outlinings and their corresponding fitted deformable superellipses was significantly less than the variability between human experts with p-value being less than 0.0001. Based on this deformable superellipse model, we have developed an efficient and robust Bayesian segmentation algorithm. This algorithm was applied to 125 prostate ultrasound images collected from 16 patients. The mean error between the computer-generated boundaries and the manual outlinings was 1.36 +/- 0.58 mm, which is significantly less than the manual interobserver distances. The algorithm was also shown to be fairly insensitive to the choice of the initial curve.

Algorithms↗

Quantitative image analysis: software systems in drug development trials.

Multi-dimensional image analysis is being used increasingly to arrive at surrogate end-points for drug development trials. Various imaging modalities such as computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET) and ultrasound are used to analyze treatments for diseases such as cancer, multiple sclerosis, osteoarthritis, and Alzheimer's disease. However, extracting information from images can be tedious and is prone to high user variability. The medical image analysis community is moving towards advanced software systems specifically designed for drug development trials. These systems can automatically identify the anatomy of interest in medical images (segmentation methods), can compare the anatomy over time or between patients (registration methods) and allow the quantitative extraction of anatomical features and the integration of the data and results into a database management system, automatically tracking the changes made to the data (audit trail generation). In this article, we present a case study using a prototype system that is used for quantifying multiple sclerosis lesions from multivariate MRI.

Clinical Trials as Topic↗

Effects of video digitization in pubic arch interference assessment for prostate brachytherapy.

Recently, it has been shown that prior to surgery a transrectal ultrasound (TRUS) study of the prostate and pubic arch can effectively determine pubic arch interference (PAI), a major stumbling block for the prostate brachytherapy (radioactive seed implantation) procedure. This PAI determination is currently being done with digital images taken directly from an ultrasound (US) machine. However, 70-75% of US machines used in prostate brachytherapy do not have a method to save or transfer digital image data for external use. To allow PAI assessment regardless of US platform and to keep costs to a minimum, we need to digitize the images from the US video output when there is no direct digital transfer capability. D/A and A/D conversions can introduce quantization error and other noises in these digitized images. The purpose of this work is to assess the image degradation caused by digitization and quantitatively evaluate whether after digitization it is still possible to accurately assess PAI. We used a PAI assessment algorithm (developed in previous research by our group) to predict the location of the pubic arch on both digital images and those captured after digitization. These predicted arch locations were compared to the "true" position of the pubic arch as established during surgery. Despite apparent image degradation due to the D/A and A/D conversions, we found no statistically significant difference between the accuracy of the predicted arch locations from the digitized images and those from the digital images. By demonstrating equally accurate determination of pubic arch locations using digital and digitized images, we conclude that TRUS-based PAI assessment can be easily and inexpensively performed in clinics where it is needed.

Brachytherapy↗

Tomosynthesis-based localization of radioactive seeds in prostate brachytherapy.

Accurately assessing the quality of prostate brachytherapy intraoperatively would be valuable for improved clinical outcome by ensuring the delivery of a prescribed tumoricidal radiation dose to the entire prostate gland. One necessary step towards this goal is the robust and rapid localization of implanted seeds. Several methods have been developed to locate seeds from x-ray projection images, but they fail to detect completely-overlapping seeds, thus necessitating manual intervention. To overcome this limitation, we have developed a new method where (1) a three-dimensional volume is reconstructed from x-ray projection images using a brachytherapy-specific tomosynthesis reconstruction algorithm with built-in blur compensation and (2) the seeds are located in this reconstructed volume. In contrast to other projection-based methods, our method can detect completely overlapping seeds. Our simulation results indicate that we can locate all implanted seeds in the prostate using a tomosynthesis angle of 30 degrees and seven projection images. The mean localization error is 1.27 mm for a case with 100 seeds. We have also tested our method using a prostate phantom with 61 implanted seeds and succeeded in locating all seeds automatically. We believe this new method can be useful for the intraoperative quality assessment of prostate brachytherapy in the future.

Brachytherapy↗

Ultrasonography and fluoroscopic fusion for prostate brachytherapy dosimetry.

PURPOSE: To investigate the feasibility of performing postimplant and intraoperative dosimetry for prostate brachytherapy by fusing transrectal ultrasound (TRUS) and fluoroscopic data. METHODS AND MATERIALS: Registration of ultrasound (prostate boundary) and fluoroscopic (seed) data requires spatial markers that are detectable by both imaging modalities. In this study, the needle tips were considered as such fiducials. Prostate phantoms were implanted with the seeds, and four localization needles were inserted. In the TRUS frame of reference, the longitudinal coordinate of the needle tip was determined by advancing the needle until the echo from its tip just registered at a known probe depth. The tip's transverse coordinates were determined from the associated TRUS slice. The three-dimensional needle tip positions were also calculated in the fluoroscopic coordinate system using a seed reconstruction method. The transformation between the TRUS and fluoroscopy coordinate systems was established by the least-squares solution using the singular value decomposition. RESULTS: With three of four needle tips as fiducials and the one remaining needle as a test target, the mean fiducial registration error was 0.8 mm and the test target registration error was 2.5 mm. When all four points were used for registration, the errors decreased to 1.1 mm. A comparison between the proposed method and CT-based dosimetry yielded a percentage of prostate volume receiving 100% and 150% of the prescribed minimal peripheral dose and minimal dose received by 90% of the prostate gland that agreed within 0.4%, 2.7%, and 4.2%, respectively. CONCLUSION: The combination of TRUS and fluoroscopy is a feasible alternative to the currently used CT-based postimplant dosimetry. Furthermore, because of online imaging capability, the method lends itself to real-time intraoperative applications.

Brachytherapy↗