Search PubMed⌕ Search

Biomedical subjects

Satoshi Saito

Publications and source records attributed to Satoshi Saito.

At least 109 records · Page 6Linked to original sources

Missense mutation of exon 3 in the type A human natriuretic peptide receptor gene is associated with myocardial infarction.

BACKGROUND: Myocardial infarction (MI) is a complex multifactorial and polygenic disorder that is thought to result from interaction between genetic make-up and various environmental factors. We previously identified a missense mutation, methionine (ATG) to isoleucine (ATC) at nucleotide 1023 (M341I), in exon 3 of the human natriuretic peptide receptor A type (hNPRA) gene. This mutation is associated with increased risk for essential hypertension (EH). The purpose of this study was to investigate association between MI and the M341I mutation in the hNPRA gene. MATERIAL/METHODS: The study population included 305 healthy control subjects and 230 patients with MI, all of whom were below the age of 70 years. To assess the identified mutation in the target exon using Taq I restriction fragment length polymorphism (RFLP), specific primers were utilized. Based on the results of the PCR-RFLP, we developed a convenient and automatic method for genotyping by allelic discrimination using TaqMan PCR chemistry. RESULTS: Multiple logistic linear regression analysis showed significant difference in genotype distribution between the control and MI groups. Overall distribution of alleles also differed significantly between the MI and control groups (p=0.028). The C allele was found more frequently in the MI group than in the control group. CONCLUSIONS: We conclude that the M341I missense mutation is associated with risk for MI and may be a genetic marker of MI in Japanese people.

Aged↗

[Three-dimensional analysis of left ventricular geometry using magnetic resonance imaging: feasibility and comparison with echocardiographic analysis].

OBJECTIVES: Reliability of left ventricular geometry assessed by echocardiography (Echo) using an assumed left ventricular mass (LVM) and one-dimensional eccentricity (relative wall thickness: RWT), remains questionable. This study evaluated the feasibility of three-dimensional left ventricular geometric analysis using magnetic resonance imaging (MRI). METHODS: Echocardiography and MRI were performed on 55 patients with hypertension. LVM was calculated using 0.8 (American Society of Echocardiography-cube LVM) + 0.6 g for Echo and the slice summation method for MRI. Eccentricity was determined by RWT (septal wall thickness + posterior wall thickness/left ventricular inner diameter) for Echo and LVM/1.05/left ventricular end-diastolic volume (LVEDV) ratio [MRI-mass volume/cavity (M/C) ratio] for MRI. Left ventricular geometry was classified into four patterns according to the presence/absence of left ventricular hypertrophy and abnormal/normal eccentricity (partition value: RWT = 0.44, MRI; M/C ratio = 2.0), and the patient distribution was compared between the two methods. RESULTS: Although the mean values for LVM were similar, the mean value for LVEDV by echocardiography was significantly higher (p < 0.0001) and the mean M/C ratio was significantly lower (r = 0.004) than those by MRI. There were widely dispersed LVM values at higher underlying values of LVM and significant correlations between MRI-LVEDV and MRI-LVM (r = 0.87) and between Echo-LVEDV and Echo-LVM (r = 0.75). There was a significant difference in patient distribution according to left ventricular geometric pattern between the two methods (p < 0.01). Concentric (n = 18) and eccentric hypertrophy (n = 12) were dominant patterns in Echo analysis, and concentric hypertrophy (n = 23) and concentric remodeling (n = 21) were dominant in MRI analysis. The left ventricular geometric patterns were different in 32 patients (58.0%). Inadequate LVEDV values in Echo were the primary cause of this phenomenon. CONCLUSIONS: Left ventricular geometric analysis by Echo results in inaccurate values. Three-dimensional left ventricular geometric analysis using MRI provides more accurate information about left ventricular geometry.

Aged↗

Circulatory support for long-term treatment of heart failure: experience with an intraventricular continuous flow pump.

BACKGROUND: A lifetime mechanical solution for advanced heart failure must be reliable, with a low risk of life-threatening complications. After extensive laboratory testing, we began clinical trials with an axial flow pump for long-term treatment of New York Heart Association class IV, transplant-ineligible patients. METHODS AND RESULTS: The Jarvik 2000 is a continuous flow device that is implanted in the apex of the left ventricle with offloading to the descending thoracic aorta. Skull-based percutaneous power delivery was derived from cochlear implant technology. We used this system in 4 patients with end-stage dilated cardiomyopathy. Exercise capacity, quality of life, device parameters, and native heart function were monitored serially. One patient died from right heart failure at 3 months. The other patients were discharged from hospital between 3 and 8 weeks postoperatively and are currently New York Heart Association I or II. Follow-up lasted between 9 and 20 months. There has been no device failure or hemolysis. Native heart function and quality of life were markedly improved. CONCLUSIONS: The Jarvik 2000 is a true assist (rather than replacement) device that functions synergistically with the native left ventricle and provides excellent quality of life. Adverse events are infrequent. This blood pump may provide a mechanical solution for end-stage heart failure in the community.

Adrenergic beta-Antagonists↗

Acute type A dissection: conservative methods provide consistently low mortality.

BACKGROUND: A wide spectrum of operative techniques are applied in acute type A dissection. Most convey hospital mortality between 10% and 20%. In this high-risk setting, we believe that a conservative approach to the aortic root and the complete resection of the primary tear are important. We reviewed the results of this policy from our aortic surgery database. METHODS: Between 1988 and December 2000, 95 acute type A dissection patients were operated on by one surgeon. They included 70 men and 25 women aged 37 to 81 years (mean 65 years). Six had Marfan syndrome. Aortic root restoration or replacement was performed during cooling, open arch repair during circulatory arrest, and hemostasis while rewarming. Eighty-seven patients had ascending aortic replacement with glue resuspension of the valve. Two others had had aortic valve replacement previously. Aortic root and partial arch replacement was performed in 6 Marfan patients. Eighteen patients had hemiarch replacement, and 6 had total arch replacement to excise the tear. RESULTS: Five patients died in hospital (5.3% 30-day mortality) and another after early readmission for mediastinal infection (6.3% total mortality). There were no deaths from bleeding. Two patients required aortic valve replacement for aortic regurgitation 2.5 and 3.0 years postoperatively. Two others required total arch replacement and thromboexclusion procedures, respectively. CONCLUSIONS: Our policy of primary tear excision and preservation of the native aortic valve has resulted in low overall mortality. We still prefer to replace the aortic root in dissected Marfan patients. In this high-risk condition, hospital survival is of paramount importance. A conservative "pathology-oriented" approach helps to achieve this aim.

Adult↗

Implant technique for the Jarvik 2000 Heart.

The Jarvik 2000 Heart is a silent compact axial flow impeller pump which is now undergoing clinical trials for both bridge to transplantation and permanent mechanical circulatory support. The pump is implanted into the apex of the failing left ventricle by left thoracotomy. A vascular graft offloads to the descending thoracic aorta so that only the left pleural cavity is opened. Power supply is through an abdominal drive line or postauricular titanium pedestal according to the treatment strategy.

Heart, Artificial↗

End-organ function during chronic nonpulsatile circulation.

BACKGROUND: Evolving blood pump technology has produced user-friendly continuous flow left ventricular assist devices, but uncertainty exists about the safety of chronic nonpulsatile circulation. We established consistently nonpulsatile blood flow in a sheep model using the Terumo magnetically suspended centrifugal pump. We then compared end-organ function between pulseless and control animals. METHODS: Fifteen healthy sheep (65 to 85 kg) were allocated to either left ventricular assist device (n = 9) or control (n = 6) groups. We implanted the device through a left thoracotomy and determined the flow rate at which pulse pressure was absent. The flow rate was then adjusted to exceed that rate (4.2 +/- 1.5 L/min), and all variables of pump function were continuously monitored by computer. Blood tests were taken serially for hepatic and renal function and plasma renin levels. The sheep were sacrificed electively at 30 (n = 3), 90 (n = 4), 180 (n = 1), and 340 (n = 1) days. Detailed histologic examination was made of the brain, liver, kidney, myocardium, and major arteries. RESULTS: All animals remained in good condition until sacrifice. All measures of end-organ function remained within normal limits for both groups. There were no histologic differences between the organs of pulsatile and nonpulsatile animals. Although there was no significant difference in mean blood pressure, plasma renin levels were substantially elevated in pulseless animals (1.4 +/- 0.3 pg/mL versus 2.9 +/- 0.3 pg/mL; p < 0.05). We also identified thinning of the medial layer of the ascending aorta in nonpulsatile sheep (1.8 +/- 0.4 mm in left ventricular assist device animals versus 2.6 +/- 0.6 mm in control sheep; p < 0.05). CONCLUSIONS: Chronic nonpulsatile circulation was well tolerated, and we found neither functional nor histologic changes in major end organs. The renin-angiotensin system was upregulated, but this did not provide a significant rise in blood pressure. The changes in the aortic wall merit further investigation. As a result of these findings, we consider that nonpulsatile devices can be used safely for long-term circulatory support.

Animals↗

Aortic root remodeling in atheromatous aneurysms: the role of selected sinus repair.

OBJECTIVE: Atheromatous ascending aortic aneurysms (AAA) frequently present with aortic regurgitation (AR) from dilatation of the sino-tubular junction (STJ) and extension of the pathological process into the root. Experience suggests that root dilatation begins in the non-coronary, then right coronary sinus. Rather than employ aortic root replacement or the David procedure, we have elected to replace the ascending aorta and remodel the STJ and involved sinuses. We studied the outcome after selective sinus replacement in 29 consecutive AAA patients between 1995 and 2001. METHODS: There were nine male and 20 females. Age ranged from 47 to 79 years (mean 67.5). Seven had arch aneurysms and four coronary artery disease. Nineteen were NYHA III or IV. Grade of AR was IV in 20, III in five and II in four. The STJ was dilated >50% of annulus diameter in each case (5.3-10.0 cm, mean 6.4 cm). All valves had three cusps. All patients underwent ascending aortic replacement. Seven had arch replacement and four coronary artery bypass. Seven had replacement of both right and non-coronary sinuses with re-implantation of the right coronary ostium. Twelve had replacement of the non-coronary sinus alone whilst nine had right coronary sinus replacement. One with dextrocardia had left coronary sinus replacement with ostial re-implantation. The graft size was within 2 mm of annulus size except for two patients (24 mm 12, 26 mm 11, and 28 mm six). Post operative echocardiographic studies were performed. None of the patients received anticoagulation. RESULTS: There were no hospital or late deaths and no thromboembolic or infective complications. Two patients had mild to moderate aortic regurgitation. These had a size 28 graft, which in retrospect was too large. Others had no significant regurgitation. CONCLUSIONS: The native aortic valve can be preserved in the majority of patients with AAA. Remodelling of the STJ and selective sinus replacement restores valve competence. Anticoagulation and prosthesis related complications are thereby avoided.

Aged↗

The Jarvik 2000 Heart. Clinical validation of the intraventricular position.

OBJECTIVE: Heart failure is now a public health epidemic. Donor hearts are severely restricted in availability. Permanent mechanical circulatory support or bridge to myocardial recovery are emerging alternatives. After extensive laboratory experience we sought to evaluate the intraventricular Jarvik 2000 Heart in patients with endstage heart failure. METHODS: The Jarvik 2000 Heart is a novel thumb-sized left ventricular assist device (LVAD) which is fitted within the apex of the native left ventricle. A vascular graft off loads this to the descending thoracic aorta. The pump rotor spins at between 8000 and 12,000 rpm providing 5-6 litres blood flow per minute. We have used the device with skull-mounted power delivery for seven permanent implants and trans-abdominal drive line for ten bridge-to-transplant patients. RESULTS: All patients survived the operation. Three died from non-device related complications. Survivors had early resolution of heart failure with return to NYHA I/II. All had pulsatile circulation. The device was user-friendly and imperceptible to the patient. Both the pump and native left ventricle contributed to the cardiac output during exercise. Seven patients have been transplanted successfully. All explanted devices were free from thrombus formation. Two permanent implant patients left hospital as early as 3 weeks postoperatively. CONCLUSIONS: The Jarvik 2000 is an effective user-friendly LVAD which allows early discharge from hospital. The intraventricular position has distinct advantages especially through absence of an inflow cannula. Synergy develops between the LVAD and native left ventricle. Early experience suggests that this may be a realistic LVAD to treat heart failure routinely in the outpatient setting.

Adult↗

Cooled-tip ablation results in increased radiofrequency power delivery and lesion size in the canine heart: importance of catheter-tip temperature monitoring for prevention of popping and impedance rise.

UNLABELLED: Since myocardial lesion size during radio-frequency (RF) ablation is limited at high power by impedance rise when electrode tip temperature exceed 100 degrees C, controlling tip temperature by continuous intraelectrode saline infusion could permit generation of larger lesion. (1) Two dogs randomly received either standard or cooled tip RF ablation at 4 to 6 separate LV sites. Power output of 30 W was delivered via modified 7 Fr deflectable catheter with 4 mm tip for up to 120 sec or until impedance rise occurred. (2) Six dogs randomly received cooled tip RF ablation at power output of 20, 30, 40 W for 120 sec. (3) Three dogs randomly received cooled tip RF ablation using room temperature saline (21-25 degrees C) or chilled saline (1-4 degrees C) infusion. RESULTS: Overall, peak tip temperature was lower for cooled vs standard RF deliveries (97 +/- 17 degrees C vs. 42 +/- 8 degrees C). Lesion depth and volume were significantly larger for cooled burns. Lesion depth and volume and the incidence of abrupt impedance rise/popping did not differ between room temperature saline and chilled saline infusion. The catheter-tip temperature at the onset of popping and abrupt impedance rise was 54 +/- 5 degrees C (48-60 degrees C) and 59 +/- 10 degrees C (50-75 degrees C). CONCLUSION: Cooled tip RF current delivery at high power is associated with increased myocardial lesion size which may facilitate successful ablation of ventricular tachycardia associated with acquired structural heart disease. Catheter-tip temperature should be maintained below 45 degrees C to prevent popping and abrupt impedance rise during RF energy delivery.

Animals↗

Relationship between polarity of the flutter wave in the surface ECG and endocardial atrial activation sequence in patients with typical counterclockwise and clockwise atrial flutter.

BACKGROUND: The relation between ECG and activation patterns within atria in typical atrial flutter (AFL) patients (pts) has not been defined due to the lack of simultaneous multisite right and left atrial mapping. METHODS: In 13 pts with AFL, a Halo catheter was positioned along tricuspid annulus and multipolar catheters were placed in right atrial appendage, His bundle region, coronary sinus (CS), proximal portion of right pulmonary artery (Bachmann's bundle region, BB) and esophagus (Eso) to record right and left atrial activation simultaneously. RESULTS: In counterclockwise (CCW) AFL (11 pts), 9 showed negative flutter wave (F) and 2 positive F in the inferior leads. CCW/negative F; CS electrograms (EGs) were proximal to distal, Eso EGs were inferior to superior and BB activation was later than CS and Eso. positive F; BB activation was earlier than CS. Eso EGs were superior to inferior or simultaneous. In clockwise (CW) AFL (7 pts), 5 showed positive F and 2 negative F. CW/positive F; BB activation preceded Eso and CS. Eso EGs were superior to inferior. CS EGs were proximal to distal (1), middle to proximal, distal (3) or proximal, distal to middle (1). negative F; CS EGs were proximal to distal. CS activation was earlier than BB or CS and BB activation were simultaneous. Eso EGs were inferior to superior. CONCLUSION: Impulse conduction to the left atrial free wall through either lower or upper interatrial connection is a major determinant of ECG morphology in AFL.

Adult↗

Ectopic atrial rhythm with exit block following catheter ablation for focal atrial tachycardias in a patient with prior surgery for atrial septal defect.

The patient was a 40-year-old woman with a history of surgery for atrial septal defect and catheter ablation for typical atrial flutter. An electrophysiological study was performed because she had palpitation and syncope. She had ectopic atrial rhythm originating from low lateral RA. Two focal atrial tachycardias ([1] superior vena cava-RA junction and [2] a lowposteroseptal RA) were successfully ablated. Following catheter ablation for the second atrial tachycardia, she developed junctional rhythm because ectopic atrial rhythm showed exit block. However, atrial activation of junctional rhythm could conduct into the ectopic atrial rhythm focus and reset the rhythm when atrial activation of junctional rhythm reached the blocked line after atrial refractoriness by preceding ectopic atrial rhythm.

Adult↗

Platelet transfusion refractoriness caused by a mismatch in HLA-C antigens.

BACKGROUND: HLA-C antigens have been thought to be of little significance in determining the efficacy of platelet transfusions. However, six alloimmunized patients were encountered who were refractory to platelet transfusions because of anti-HLA-Cw3, -Cw3, -Cw7, or -Cw8. STUDY DESIGN AND METHODS: Between 1995 and the present, 88 patients with hematologic malignancies became refractory to random-donor platelet transfusions due to HLA antibodies. HLA-A- and HLA-B-compatible platelet transfusions were successful in boosting platelet levels with 82 of the patients. This study concerns the remaining six HLA-immunized patients who were refractory to HLA-A- and HLA-B-compatible platelet transfusions. The response to the platelet transfusions was assessed by calculating both 1- and 24-hour posttransfusion CCIs for each transfusion. RESULTS: The average CCI(1 hour) and CCI(24 hours) in all patients were 20.0 and 12.8 for HLA-A-, HLA-B-, and HLA-C-compatible transfusions and were 1.4 and 1.2 for HLA-A- and HLA-B-compatible but HLA-C-incompatible transfusions, respectively (p < 0.001). CONCLUSION: These findings clearly indicate that matching of the HLA-C antigens is also required in some alloimmunized patients to obtain the effectiveness of platelet transfusions.

Adolescent↗

HLA DRB10405-DQB10401 haplotype is associated with autoimmune pancreatitis in the Japanese population.

BACKGROUND & AIMS: Autoimmune pancreatitis is a distinctive disease entity characterized by high serum immunoglobulin G4 concentrations. Because of the close association between some autoimmune diseases and particular alleles of major histocompatibility complex genes, we investigated the association between HLA alleles and autoimmune pancreatitis. METHODS: HLA-A, -B, -C, -DR, and -DQ gene typing and HLA-DRB1, -DQB1, and -DPB1 allele typing were performed by the polymerase chain reaction sequence-specific primers method and the restriction fragment length polymorphism method, respectively, in 40 patients with autoimmune pancreatitis, 43 patients with chronic calcifying pancreatitis, and 201 healthy subjects. RESULTS: In patients with autoimmune pancreatitis compared with healthy subjects, we found a significant increase in DR4 (73% vs. 44%, corrected P = 0.01) and DRB1*0405 (58% vs. 21%, corrected P = 0.000026) and DQ4 (58% vs. 26%, corrected P = 0.001) and DQB1*0401 (58% vs. 21%, corrected P = 0.000017). The DRB1*0405-DQB1*0401 haplotype in autoimmune pancreatitis showed no significant association with any HLA class I antigens, in contrast to the B54-DRB1*0405-DQB1*0401 haplotype reported in autoimmune hepatitis. The frequencies of DRB1*0405 and DQB1*0401 were significantly high in patients with autoimmune pancreatitis compared with chronic calcifying pancreatitis. CONCLUSIONS: It is probable that DRB1*0405-DQB1*0401 haplotype is associated with autoimmune pancreatitis in the Japanese population.

Adult↗

Association of a novel single nucleotide polymorphism of the prostacyclin synthase gene with myocardial infarction.

BACKGROUND: Myocardial infarction (MI) is a complex multifactorial and polygenic disorder that is thought to result from an interaction between an individual's genetic makeup and various environmental factors. The purpose of this study was to investigate the association between a novel single nucleotide polymorphism in the prostacyclin synthase gene and MI. METHODS AND RESULTS: By the use of polymerase chain reaction-single-strand conformation polymorphism analysis, we identified a single nucleotide polymorphism, C1117A, in exon 8. This nucleotide change did not cause an amino acid change in codon 373. We performed an association study of the polymorphism in 138 patients and 130 healthy control subjects. Multiple logistic linear regression analysis showed the genotype distributions were significantly different between the control group and the MI group (odds ratio, 2.12; 95% CI, 1.47-3.05, P =.04). The C/C genotype was found more frequently in the MI group than in the control group. CONCLUSIONS: We conclude that the C1117A polymorphism in exon 8 is associated with risk for MI and may be a genetic marker of MI in Japanese persons.

Case-Control Studies↗

Postauricular percutaneous power delivery for permanent mechanical circulatory support.

OBJECTIVE: Percutaneous driveline infection continues to detract from both quality and length of life in patients with a left ventricular assist device. We have pursued an alternative route by using a skull-mounted percutaneous pedestal similar to cochlear implant technology. We have now used this method in patients implanted with the Jarvik 2000 heart (Jarvik Heart, Inc, New York, NY) as destination therapy for end-stage (New York Heart Association class IV) heart failure. METHODS: Four men with cardiomyopathy aged 61 to 72 years received the Jarvik 2000 heart with postauricular power delivery for permanent mechanical circulatory support. The power cable was brought through the second posterior intercostal space and routed through the neck to a percutaneous titanium implant screwed to the skull. This joins with the cable to the external controller and battery. RESULTS: In 3 patients the pedestal healed well and remained free from infection up to 1 year. The system was user friendly, and the whole external apparatus is exchangeable. The second patient had a subdural hematoma. This caused us to improve the preparation and modify the implant procedure. CONCLUSION: For widespread use, permanent implantable circulatory support requires a reliable, user-friendly device with freedom from powerline infection. Our early experience with the Jarvik 2000 heart suggests that rigid fixation and the vascularity of scalp skin promote healing and reduce the risk of driveline infection.

Aged↗

Nafamostat mesilate attenuates radical formation in the rat lung infused with endotoxin.

We previously reported direct evidence of respiratory bursting by neutrophils in the pulmonary circulation of endotoxin-infused rats. To evaluate the effect of the protease inhibitor nafamostat mesilate (NM) on leukocyte-mediated radical formation in the pulmonary circulation of rats infused with endotoxin, we observed and measured the number of sticking leukocytes and quantified radical production in the pulmonary circulation of endotoxin-infused rats by means of a fluorescent imaging technique. Plasma C3a (desArg) was also measured using an enzyme-linked immunosorbent assay. Three groups (n = 5) of rats were infused with 4.5 mg/kg/h endotoxin (Et group), 50 microg/kg/h NM + endotoxin (NM group), or physiological saline (Ct group) for 2 h. The number of the leukocytes adhering within pulmonary capillaries, oxygen radical production in the rat pulmonary circulation, and plasma C3a (desArg) were all lower in the NM group than in the Et group. The leukocytes producing oxygen radicals were confirmed to be neutrophils by electron microscopic analysis of cerium deposition. We conclude that NM attenuates plasma C3a formation, neutrophil adherence to pulmonary capillaries, and their production of oxygen radical in rats infused with endotoxin.

Animals↗

Sclerosing encapsulating peritonitis: regional changes of peritoneum.

Sclerosing encapsulating peritonitis (SEP) is characterized by the diffuse appearance of marked sclerotic thickening of the peritoneal membrane. We experienced a case with SEP accompanied by regional changes of peritoneum. A 37-year-old woman with end-stage renal failure was started on continuous ambulatory peritoneal dialysis in 1985 and was transferred to hemodialysis in 1997. She was admitted because of ileus in 1998 with SEP and died of septicemia. The diagnosis of SEP was confirmed via the autopsy. The root of the mesentery was retracted and shortened. Since the peritoneal change was marked in the regions with free margin of mesentery and was less apparent in the regions not adhered to mesentery, it is indicated that mechanical stress also contributes to the occurrence of SEP. Since calcification and ossification were only seen in a free margin of small bowel from mesentery, it is suggested that there is a close relationship between calcification and ossification. Since fibrosis invaded into the muscle layer, dysfunction of bowel movement as well as bowel obstruction contributed to the appearance of ileus. It is suggested that mechanical stress by the root of mesentery which is retracted and shortened also contributes to the appearance of SEP.

Adult↗