Search PubMed⌕ Search

Biomedical subjects

Sanjeev Kaul

Publications and source records attributed to Sanjeev Kaul.

At least 19 recordsLinked to original sources

Vattikuti Institute prostatectomy: contemporary technique and analysis of results.

OBJECTIVES: Contemporary techniques of radical prostatectomy achieve excellent oncologic outcomes; erectile dysfunction is the most common adverse effect. We have modified our technique of robotic radical prostatectomy (Vattikuti Institute prostatectomy [VIP]) in an attempt to minimize decrease of erectile function while maintaining the excellent oncologic outcomes achieved by the radical retropubic prostatectomy. We present our current technique of VIP with preservation of the lateral prostatic fascia ("veil of Aphrodite"). METHODS: A total of 2652 patients with localized carcinoma prostate underwent VIP. The salient features of our current technique are early transection of the bladder neck, preservation of the prostatic fascia, and control of the dorsal vein complex after dissection of the prostatic apex. Oncologic and functional outcomes were obtained through a questionnaire collected by a third party not involved in patient care. RESULTS: Complete follow-up information was obtained in 1142 patients with a minimum follow-up of 12 mo (range: 12-66 mo; median: 36 mo). The actuarial 5-yr biochemical recurrence rate was 8.4% and the actual biochemical recurrence rate was 2.3%. Median duration of incontinence was 4 wk; 0.8% patients had total incontinence at 12 mo. The intercourse rate was 93% in men with no preoperative erectile dysfunction undergoing veil nerve-sparing surgery, although only 51% returned to baseline function. CONCLUSIONS: VIP with veil nerve sparing offers oncologic and continence results that are comparable to the results of conventional nerve-sparing radical prostatectomy. Early potency results are encouraging.

Adult↗

da Vinci-assisted robotic partial nephrectomy: technique and results at a mean of 15 months of follow-up.

OBJECTIVE: Laparoscopic partial nephrectomy is gaining acceptance as an alternative to open surgery for small renal tumours, although technical difficulty of intracorporeal suturing and concerns over warm ischemia time are limitations. Previous work has demonstrated that suturing with the robotic system is easier compared with laparoscopy. We believe the robot has an application and we report our initial experience in 10 patients undergoing robotic partial nephrectomy. METHODS: Ten patients with small exophytic renal masses underwent intraperitoneal robotic partial nephrectomy. Principles of traditional open surgery were followed and intraoperative ultrasound was used to define resection margins. The renal artery was clamped with laparoscopic bulldog clamps and indigo carmine was administered intravenously to detect entry into collecting system. Suture closure and FLOSEAL were used for hemostasis. Frozen sections were obtained in all patients. RESULTS: Seven men and three women, mean age 59 yr, underwent robotic partial nephrectomy. Mean tumour size was 2 cm. Mean console and warm ischemia time were 158 min and 21 min, respectively. The median hospital stay was 1.5 d. Pathology revealed renal cell carcinoma in eight, oncocytoma in one, and lipoma in one. All resection margins were negative. Follow-up ranged from 6 to 28 mo. CONCLUSIONS: Robotic partial nephrectomy is a viable alternative to open or laparoscopic partial nephrectomy in carefully selected patients with small renal tumours. The advantages of the robotic system must be weighed against its cost. Further studies will determine if reduction in procedure complexity warrants the expense of such technology.

Adult↗

Robotic radical prostatectomy: evolution from conventional to VIP.

Following the popularization of Vattikuti Institute Prostatectomy technique of robotic radical prostatectomy (RARP) by Menon et al., RARP has been gaining steady acceptance as a preferred alternative to both open and laparoscopic radical prostatectomy (LRP). Up until now, radical retropubic prostatectomy has been considered the gold standard for treatment of organ confined prostate cancer. Despite significant improvements in intraoperative blood loss and functional outcomes, driven primarily by the description of anatomical radical prostatectomy by Walsh, the perioperative morbidity, analgesic requirement, and recovery times have remained disadvantages of the open approach. LRP has been unable to gain widespread acceptance because of technical difficulty and a steep learning curve. The da Vinci assisted approach incorporates the advantages of minimally invasive approach while improving upon the results of the open approach. This paper traces the evolution of RARP and describes technical modifications incorporated at the Vattikuti Urology Institute including operative data, complications, and functional outcomes.

Humans↗

Robotic extended pyelolithotomy for treatment of renal calculi: a feasibility study.

Percutaneous nephrolithotomy (PCNL) remains the treatment of choice for staghorn renal calculi. Many reports suggest that laparoscopy can be an alternative treatment for large renal stones. We wished to evaluate the role and feasibility of laparoscopic extended pyelolithotomy (REP) for treatment of staghorn calculi. Thirteen patients underwent REP for treatment of staghorn calculi over a 12-day period. Twelve patients had partial staghorn stones and one had a complete staghorn stone. All patients had pre-operative and post-operative imaging including KUB and computed tomography. All procedures were completed robotically without conversion to laparoscopy or open surgery. Mean operative time was 158 min and mean robotic console time was 108 min. Complete stone removal was accomplished in all patients except the one with a complete staghorn calculus. Estimated blood loss was 100 cc, and no patient required post-operative transfusion. REP is an effective treatment alternative to PCNL in some patients with staghorn calculi. However, patients with complete staghorn stones are not suitable candidates for this particular technique.

Adult↗

Robotic radical prostatectomy with the "Veil of Aphrodite" technique: histologic evidence of enhanced nerve sparing.

OBJECTIVE: We have recently described a modification (Veil of Aphrodite) designed to preserve the lateral prostatic fascia (LPF) during robotic prostatectomy. Here, we histologically compare the Veil of Aphrodite technique (VT) and standard nerve-sparing technique (ST). METHODS: Thirty-six consecutive prostatectomies performed by a single surgeon were processed by the whole-mount method. The right and left anterolateral (AL) zones of each prostate were independently evaluated for LPF, plane of excision, capsular incision/margin status, margin clearance, and quantitative analysis of periprostatic nerve bundles using S100 immunostain. RESULTS: There were 42 AL zones with ST and 30 with VT. In all 42 ST zones, the plane of excision was outside the prostate and a rim of LPF was present. The mean margin clearance was 1.4 mm (0.6-2.8 mm) and the mean nerve bundle count was 10 (3-19). Capsular incision and margin status were negative in all 42. For VT, 24 of 30 zones lacked LPF and the plane of excision ran just by the prostatic edge. The mean margin clearance was 0.3 mm (0-1.7 mm) and the mean nerve bundle count was two (0-11). Two VT AL zones revealed capsular incision; the margin was negative for tumour in all 30. Differences in the margin clearances and nerve bundle counts between ST and VT were statistically significant (p < 0.0001). CONCLUSIONS: The LPF contains nerve bundles that run along the surface of the AL zones. The VT is a safe procedure that effectively preserves the LPF and appears to provide enhanced nerve sparing as compared to the ST.

Aged↗

Learning curve using robotic surgery.

The da Vinci (Intuitive Surgical, Inc., Sunnyvale, CA) surgical system is being used by an increasing number of surgeons across several surgical specialties. The robotic interface is different not only to open surgery, but also to laparoscopy because it involves remote surgical control, stereoscopic vision, and lack of haptic feedback. As the transition is made from traditional open to robotic surgery, factors such as learning of robotic skills, assessment of proficiency in robotics, and structured training for urologists in practice and residents assumes importance. Understanding how the robotic surgical technique is learned and how such learning can be best assessed will enable us to define protocols for training and set standards for proficiency. Learning curve and surgical dexterity are two parameters that are used to compare surgical learning and training. This article presents the current gold standard for assessing skill training and compares surgical skill acquisition and proficiency using conventional laparoscopy and robotic interfaces.

Clinical Competence↗

Functional outcomes and oncological efficacy of Vattikuti Institute prostatectomy with Veil of Aphrodite nerve-sparing: an analysis of 154 consecutive patients.

OBJECTIVES: To report updated results, at 1 year of follow-up, of a modified nerve-sparing robotic radical prostatectomy that preserves the lateral prostatic fascia (Veil of Aphrodite). PATIENTS AND METHODS: From January to December 2003, 154 consecutive men had a Vattikuti Institute prostatectomy with Veil of Aphrodite nerve-sparing by one surgeon. A prospective database recorded patient demographics, intraoperative, peri-operative, and pathological variables. Peri-operative complications were recorded using the Clavien classification. Patients had serum prostate-specific antigen (PSA) levels measured every 3 months and self-administered the International Prostate Symptom Score and Sexual Health Inventory for Male questionnaires before and at 1 year after surgery. RESULTS: The men had a mean age of 57.4 years, a mean body mass index of 27.2 kg/m(2), and a mean PSA level before surgery of 5.11 ng/mL. The mean operative duration was 122 min. At 1 year, 96% of the men reported having had intercourse and 71% had recovered normal erectile function. One man had a Clavien grade II complication, 4.6% of men with organ-confined disease had positive surgical margins, and no patient had a PSA recurrence at 12 months; 97% of the men were continent at 1 year, and the median time to continence was 14 days. CONCLUSION: Veil of Aphrodite nerve-sparing surgery provides better recovery of sexual function at 1 year than in contemporary series from centres of excellence, without compromising cancer control and urinary function.

Adult↗

Robotic radical prostatectomy: a minimally invasive therapy for prostate cancer.

The robotic radical prostatectomy technique involves the use of the da Vinci surgical robot (Intuitive Surgical, Sunnyvale, CA) assistance with three-dimensional stereoscopic visualization and ergonomic multijointed instruments. This article presents our results after treating 750 patients with robot-assisted radical prostatectomy at the Vattikuti Institute of Urology.

Adult↗

Robotic radical prostatectomy with preservation of the prostatic fascia: a feasibility study.

OBJECTIVES: To describe a feasibility study of our ability to preserve the prostatic fascia in men undergoing robotic radical prostatectomy. The prostate is covered anterolaterally by prostatic fascia, also called lateral pelvic fascia or the parietal layer of endopelvic fascia. The prostatic fascia is rich in vessels, nerves, and smooth muscle. We hypothesized that preservation of this fascial layer may result in improved postoperative potency. METHODS: The technique was first attempted in 15 men undergoing radical cystoprostatectomy, in which accidental entry to the prostatic tissue is not critical. Thereafter, it was performed in 6 impotent men undergoing robotic radical prostatectomy. The fascia was excised and stained for prostate-specific antigen and neural and muscle tissue. The technique was then performed in 35 potent men (Sexual Health Inventory for Men score greater than 21) undergoing robotic radical prostatectomy. Postoperative potency was evaluated with a self-administered questionnaire (Sexual Health Inventory for Men). RESULTS: Under the magnification of the da Vinci robotic system, and also shown histologically, the prostatic fascia is a multifascial layer of fibrovascular tissue, covering the anterolateral aspect of the prostate. It stains positive for smooth muscle and nerves, but negative for prostate-specific antigen. The amount of neural tissue in the fascia is variable, but never exceeds that in the neurovascular bundle. At 12 months of follow-up, 34 (97%) of 35 men undergoing fascia-preserving robotic radical prostatectomy had erections strong enough for vaginal penetration, and 30 (86%) had normal erections (Sexual Health Inventory for Men greater than 21). CONCLUSIONS: Preservation of the prostatic fascia is safe and feasible, without compromising the surgical margins, and allows enhanced preservation of neural tissue during robotic prostatectomy with an apparent improvement in potency.

Fascia↗

Potency following robotic radical prostatectomy: a questionnaire based analysis of outcomes after conventional nerve sparing and prostatic fascia sparing techniques.

PURPOSE: Anatomical nerve sparing radical prostatectomy provides excellent cancer control, although the recovery of sexual function is variable. We recently described a technique to preserve the prostatic fascia (veil of Aphrodite) that appears to enhance the quality of nerve preservation during robotic prostatectomy. In January 2003 we initiated a prospective study comparing patients undergoing prostatic fascia preservation with those undergoing conventional nerve sparing robotic radical prostatectomy. We report results at 12 months of followup MATERIALS AND METHODS: From January to August 2003, 58 potent men with a Sexual Health Inventory for Men score (SHIM) of greater than 21 without phosphodiesterase 5 inhibitors underwent Vattikuti Institute prostatectomy, including 35 with preservation of the prostatic fascia (study) and 23 with conventional nerve sparing (control). Potency was assessed with self-administered SHIM questionnaires 12 months after surgery. The primary end point was achievement of erections strong enough for penetration with or without oral medications. The secondary end point was the ability to achieve normal erections (SHIM greater than 21) with and without medications. RESULTS: At 12 months of followup 17 of 23 control (74%) and 34 of 35 study (97%) patients achieved erections strong enough for intercourse (p = 0.002). Four control (17%) and 18 study (51%) patients achieved normal erections (SHIM greater than 21) without medication (p <0.0001). Six control (26%) and 30 study (86%) patients achieved normal erections with or without phosphodiesterase 5 inhibitors (p <0.0001). CONCLUSIONS: Potency rates after radical prostatectomy vary with the measure used to define potency. Irrespective of the definition used patients undergoing prostatic fascia preserving radical prostatectomy have significantly better potency outcomes than patients undergoing conventional nerve sparing robotic prostatectomy at 12 months of followup.

Aged↗

The influence of renal function on hydroxyurea pharmacokinetics in adults with sickle cell disease.

This was an open-label, nonrandomized, 2-center study conducted to assess the influence of renal function on the pharmacokinetics of hydroxyurea in adults with sickle cell disease (SCD). Seventeen patients were divided into 5 groups: normal renal function (n = 7), mild renal impairment (n = 2), moderate renal impairment (n = 3), severe renal impairment (n = 2), and end-stage renal disease (ESRD, n = 3). Except for patients with ESRD, all the patients received a 15-mg/kg single oral dose of hydroxyurea. Patients with ESRD received a 15-mg/kg oral dose of hydroxyurea on 2 occasions. Blood and urine samples were collected for the assessment of hydroxyurea pharmacokinetics. The results indicate that the systemic exposure increases and the urinary recovery decreases as the degree of renal insufficiency worsens. On the basis of the exposure and the apparent clearance from the current and 2 historical studies, the authors have proposed an initial dosing regimen of hydroxyurea (7.5 mg/kg/day) for SCD patients with CL(cr) <60 mL/min. This dosing strategy is anticipated to provide a safe dose for SCD patients with renal impairment.

Adult↗

Drug-drug and drug-food interactions between tenofovir disoproxil fumarate and didanosine.

The drug-drug and drug-food interactions between tenofovir DF and didanosine EC were evaluated in 2 pharmacokinetic studies in healthy adult subjects. When 400 mg was dosed with tenofovir DF, mean didanosine AUC was increased by 44% to 60% following fasted or fed administration. Staggered coadministration (2 hour, fasted) of a reduced didanosine dose of 250 mg resulted in equivalent didanosine exposure, while simultaneous administration with tenofovir DF in the fasted and fed state resulted in didanosine AUCs similar to that of the reference treatment of 400 mg alone in the fasted state. These data indicate that a dose reduction of didanosine is warranted when it is used with tenofovir DF. The drug-drug-food interaction of didanosine may offer more flexible dosing of didanosine EC when it is used with tenofovir DF. Patients receiving tenofovir DF and didanosine together should be carefully monitored for safety and efficacy.

Adenine↗

Vattikuti Institute prostatectomy, a technique of robotic radical prostatectomy for management of localized carcinoma of the prostate: experience of over 1100 cases.

Advances in surgical techniques, technology, and surgeons' skills have allowed robot-assisted radical prostatectomy to be an option in the management of organ-confined prostate cancer. The goals of the VIP technique are to cure cancer, preserve urinary continence, preserve potency, and decrease morbidity, along with the benefits of a minimally invasive surgery and excellent cosmesis. VIP is nearly equal to traditional retro-pubic prostatectomy, with certain outstanding advantages.

Equipment Design↗

Acute complications associated with greenfield filter insertion in high-risk trauma patients.

BACKGROUND: Use of Greenfield filters (GFs) to prevent fatal pulmonary embolism (PE) in trauma patients is generally well accepted. Nonetheless, a surprisingly small number of trauma surgeons insert filters in their patients. Among the reasons cited is fear of complications. METHODS: We observed three femoral arteriovenous fistulae (AVF) in trauma patients who had inferior vena caval placement of filters for PE prophylaxis in one 12-month period (academic year 1999). In an effort to document the magnitude of this problem, we evaluated trauma patients who had a GF inserted in academic year 2000. RESULTS: During that year, 133 consecutive patients (8.6% of trauma admissions) received 133 GFs through a percutaneous approach. The most common isolated indications for GF insertion included closed head injuries (n = 28), multiple long bone fractures (n = 27), pelvic and acetabular fractures (n = 6), spinal cord injuries (n = 16), and vertebral fractures (n = 3). Five patients had documented deep venous thrombosis (DVT) diagnosed by duplex ultrasonography before GF placement, and 11 patients had other indications requiring a filter. There were 37 patients with more than one indication requiring filter placement. Most patients (57%) underwent preinsertion duplex scanning of their lower extremity veins; 77% of patients underwent postinsertion scanning. Filters were inserted an average of 6.8 +/- 0.6 (SE) days after trauma. No AVF were suspected clinically or detected ultrasonographically. No operative or postoperative complications occurred. DVT was observed in 30% of patients despite 92% prophylaxis; there was a 26% incidence of de novo thrombi detected. None of the patients evidenced DVT clinically. CONCLUSION: Our data indicate that complications of GF insertion for prophylaxis against PE from DVT complicating trauma patients continue to be negligible. In addition, the incidence of insertion-site thrombosis may be lower than expected. Moreover, femoral AVF is a rare complication of this procedure.

Adolescent↗

Isolated traumatic brain injury: age is an independent predictor of mortality and early outcome.

BACKGROUND: Geriatric trauma patients have a worse outcome than the young with comparable injuries. The contribution of traumatic brain injury (TBI) to this increased mortality is unknown and has been confounded by the presence of other injuries. The purpose of this study was to investigate the role of age in the mortality and early outcome from isolated TBI. METHODS: This was a retrospective analysis of all adult patients with isolated TBI (Abbreviated Injury Scale score > or = 3) admitted during a 5-year period to two Level I trauma centers. Mortality, Glasgow Outcome Scale score at discharge, therapy, and complications were compared for elderly (age > or = 65 years) and younger patients. RESULTS: Of 694 patients, 22% were defined as elderly. The mortality for the elderly group was twice that of their younger counterparts (30% vs. 14%, p < 0.001), even for those with mild to moderate TBI (Glasgow Coma Scale score of 9-15). Thirteen percent of elderly survivors had a poor functional outcome (Glasgow Outcome Scale score of 2 or 3) at hospital discharge versus 5% in the young group (p < 0.01). Independent factors associated with a high mortality were age and Glasgow Coma Scale score. CONCLUSION: The mortality from TBI is higher in the geriatric population at all levels of head injury. In addition, functional outcome at hospital discharge is worse. Although some of this increased mortality may be explained by complications or type of head injury, age itself is an independent predictor for mortality in TBI.

Adult↗

Lack of effect of simultaneously administered didanosine encapsulated enteric bead formulation (Videx EC) on oral absorption of indinavir, ketoconazole, or ciprofloxacin.

Didanosine formulation that contains a buffer to prevent it from acid-mediated degradation can result in a significant decrease in the oral absorption of certain drugs because of interactions with antacids. An enteric formulation of didanosine is unlikely to cause such drug interactions because it lacks antacids. This study was undertaken to determine whether the enteric bead formulation of didanosine (Videx EC) influences the bioavailability of indinavir, ketoconazole, and ciprofloxacin, three drugs that are representative of a broader class of drugs affected by interaction with antacids. Healthy subjects of either gender were enrolled in three separate open-label, single-dose, two-way crossover studies. Subjects were randomized to treatment A (800 mg of indinavir, 200 mg of ketoconazole, or 750 mg of ciprofloxacin) or treatment B (same dose of indinavir, ketoconazole, or ciprofloxacin, but with 400 mg of didanosine as an encapsulated enteric bead formulation). A lack of interaction was concluded if the 90% confidence interval (CI) of the ratio of the geometric means of log-transformed C(max) and AUC(0-infinity) values (i.e., values for the area under the concentration-time curve from time zero to infinity) of indinavir, ketoconazole, and ciprofloxacin were contained entirely between 0.75 and 1.33. For indinavir (n = 23), the point estimate (90% CI; minimum, maximum) of the ratios of C(max) and AUC(0-infinity) values were 0.99 (0.91, 1.06) and 0.96 (0.91, 1.02), respectively. In the ketoconazole study, 3 of 24 subjects showed anomalous absorption of ketoconazole (i.e., an approximately 8-fold-lower AUC compared to historical data), which was the reference treatment. A post hoc analysis performed after these three subjects were excluded indicated that the point estimates (90% CI) of the ratios of C(max) and AUC(0-infinity) values were 0.99 (0.86, 1.14) and 0.97 (0.85, 1.10), respectively. For ciprofloxacin (n = 16), the point estimate (90% CI) of the ratios of C(max) and AUC(0-infinity) values were 0.92 (0.79, 1.07) and 0.91 (0.76, 1.08), respectively. All three studies clearly indicated a lack of interaction. The T(max) and t(1/2) for indinavir, ketoconazole, and ciprofloxacin were similar between treatments. Our results showed that the lack of interaction of didanosine encapsulated enteric bead formulation with indinavir, ketoconazole, and ciprofloxacin indicates that this enteric formulation of didanosine can be concomitantly administered with drugs whose bioavailability is known to be reduced by interaction with antacids.

Absorption↗

Bioequivalence of two formulations of didanosine, encapsulated enteric-coated beads and buffered tablet, in healthy volunteers and HIV-infected subjects.

Didanosine is an acid labile drug and hence has been given with buffering agents. To avoid the need for concurrent administration with antacids, an encapsulated enteric-coated bead formulation of didanosine was developed. The objective of this study was to assess the bioequivalence of the encapsulated enteric-coated beads compared to the buffered tablet. Two separate open-label, randomized, two-way crossover studies were conducted, one in healthy subjects and the other in HIV-infected subjects (with CD4 cell counts > 200 cells/mm3). All subjects received a 400-mg dose of the buffered tablet (reference formulation) and the encapsulated enteric-coated beads (test formulation). Blood samples were collected over 12 hours, and plasma levels of didanosine were determined using a validated assay. The 90% confidence interval (CI) of the ratio of the geometric means of log-transformed Cmax and AUCinfinity values were used to assess bioequivalence between the two formulations using the equivalence interval of 0.80 and 1.25. In healthy volunteers (n = 46), the point estimate and 90% CI of the ratios of Cmax and AUCinfinity values were 0.58 (0.52, 0.64) and 1.02 (0.95, 1.01), respectively. In HIV-infected subjects (n = 30), the point estimate and 90% CI of the ratios of Cmax and AUCinfinity values were 0.64 (0.56, 0.72) and 0.95 (0.86, 1.06), respectively. Median t(max) value increased significantly from 0.67 hours for the buffered tablet in both studies to 2.33 hours (in healthy subjects) or 2.0 hours (in HIV-infected subjects) for the enteric-coated beads. The mean half-life of didanosine was similar between treatments and ranged between 1.60 and 1.70 hours across healthy and HIV-infected subjects. It was concluded that the encapsulated enteric-coated bead formulation of didanosine is equivalent to the buffered tablet in the extent of exposure but differs in the rate of absorption. The pharmacokinetic profile of the enteric formulation appears to be similar in healthy and HIV-infected subjects.

Administration, Oral↗