Search PubMed⌕ Search

Biomedical subjects

Salvatore Fanali

Publications and source records attributed to Salvatore Fanali.

36 records · Page 2Linked to original sources

Use of a hepta-Tyr antibiotic modified silica stationary phase for the enantiomeric resolution of D,L-loxiglumide by electrochromatography and nano-liquid chromatography.

Hepta-Tyr antibiotic modified silica stationary phase was used for the chiral resolution of D,L-loxiglumide, a new drug under investigation proposed for the treatment of gastrointestinal diseases. The chiral stationary phase was packed into fused silica capillaries of 75 microm i.d. for a length of only 7 cm and used for both capillary electrochromatography (CEC) and nano-liquid chromatography (nano-LC) running the experiments with the same instrumentation; in order to increase the electroosmotic flow (EOF) the antibiotic stationary phase was mixed with amino-silica particles (3:1, w/w) generating a relatively high reversed EOF. The enantiomeric resolution of loxiglumide by CEC was strongly influenced by several experimental parameters such as applied electric field, mobile phase composition, capillary temperature, etc. Optimum experimental conditions were found applying 15 kV at 20 degrees C and eluting with acetonitrile-sodium phosphate buffer at pH 6 (1:1, v/v). The same capillary was tested for nano-LC experiments. Good chiral separation of loxiglumide was achieved selecting the appropriate mobile phase considering the type and concentration of organic modifier. The nano-LC optimised method was therefore validated and applied to the analysis of a pharmaceutical formulation declared to contain only D-loxiglumide.

Anti-Bacterial Agents↗

Analysis of ketorolac and its related impurities by capillary electrochromatography.

Capillary electrochromatography (CEC) was employed for the assay of ketorolac (KT) and its known related impurities [1-hydroxy analog of ketorolac (HK), 1-keto analog of ketorolac (KK), ketorolac decarboxylated (DK)] in both drug substance and coated tablets. Detection was made at 323 nm and flufenamic acid was selected as internal standard. The experiments were performed in a 100 microm i.d. capillary packed with RP-18 silica particles (33.0, 24.5, 23.0 cm total, effective and packed lengths, respectively). The composition of the mobile phase was optimised by changing pH of the buffer and acetonitrile (ACN) content and by addition of other organic modifiers (methanol, ethanol, isopropanol, n-propanol) in order to evaluate the effect of these factors on the method performance (efficiency, retention and resolution). The optimum mobile phase consisted of a mixture of 50 mM ammonium formate buffer pH 3.5-water-acetonitrile (10:20:70, v/v/v), while voltage and temperature were set at 30 kV and 20 degrees C, respectively. Applying these conditions, all peaks were baseline resolved and the analysis was performed in less than 9 min. Selectivity, repeatability of retention time and peak area, detection and quantitation limits, linearity and range, precision and accuracy were also investigated. R.S.D. and bias values obtained for all the analytes were below 5% and sensitivity was satisfactory, thus the method was deemed suitable for pharmaceutical quality control. Applying the method to coated tablets, a recovery of 98.5+/-0.8% and an R.S.D. of 0.5% were found.

Calibration↗

Separation of tocopherols by nano-liquid chromatography.

Nanoliquid chromatography (nano-LC) was used for the separation of tocopherols (delta-, gamma-, alpha-TOH), alpha-tocopherol acetate (alpha-TOH-Ac) and an antioxidant compound, namely butylated hydroxytoluene (BHT) used to prevent TOHs autoxidation. The separation was carried out in a fused silica capillary of 100 microm I.D. and 375 microm O.D. packed in our laboratory with RP18 silica stationary phase of either 5- or 3-microm diameter (23-cm long). The mobile phase was composed by mixtures of methanol (MeOH), acetonitrile (MeCN) and water. Typical analyses time for the separation of all the five components of the mixture were 6-9 min depending on the composition of the mobile phase. Efficiency and resolution were strongly influenced by the particle diameter and the highest Rs and N/m values were observed using 3-microm RP18 particles. Experiments performed with capillaries packed with 3-microm RP18 particles provided good limit of detection (LOD) and limit of quantification (LOQ) (for delta-, gamma-TOH, alpha-TOH-Ac were 4 and 8 microg/ml, while for alpha-TOH were 6 and 10 microg/ml, respectively). The optimized method was applied to extracts of serum and pharmaceutical preparation containing alpha-TOH and alpha-TOH-Ac.

Chromatography, Liquid↗

Experimental assessment of electromigration properties of background electrolytes in capillary zone electrophoresis.

Electromigration dispersion (EMD) properties of background electrolytes (BGEs) used in capillary zone electrophoresis (CZE) are of key importance for the success of an analysis. The knowledge of these properties may serve well for the prediction of the asymmetry of peaks of analytes, for the prediction of unsafe regions where a strong interference of system zones may be expected, and for the selection of optimum conditions where the analytes of interest may give sharp and practically symmetric peaks. Present theories enable one to calculate and predict EMD properties of many BGEs but there is also a lot of BGEs that are beyond the present theoretical models as far as their composition and equilibria involved are considered. This contribution brings a method for assessment of EMD properties of any BGE from easily accessible experimental data. The method proposed is illustrated by model examples both for cationic and anionic separations. Imidazole acetate, histamine acetate, and histidine acetate served as model BGEs for cationic separations; as the model BGE for anionic separations, Tris-borate and sodium-borate BGEs have been selected since these buffers are frequently used and borate is well-known for its complexing equilibria in aqueous solutions.

Acetates↗

Reversed-phase capillary electrochromatography for the simultaneous determination of acetylsalicylic acid, paracetamol, and caffeine in analgesic tablets.

The separation and simultaneous determination of caffeine, paracetamol, and acetylsalicylic acid in two analgesic tablet formulations was investigated by capillary electrochromatography (CEC). The effect of mobile phase composition on the separation and peak efficiency of the three analytes was studied and evaluated; in particular, the influence of buffer type, buffer pH, and acetonitrile content of the mobile phase was investigated. The analyses were carried out under optimized separation conditions, using a full-packed silica capillary (75 microm ID; 30.0 cm and 21.5 cm total and effective lengths, respectively) with a 5 microm C8 stationary phase. A mixture of 25 mM ammonium formate at pH 3.0 and acetonitrile (30:70 v/v) was used as the mobile phase. UV detection was at 210 nm. Good linearity was found in the range of 50-200, 20-160, and 4-20 microg/mL for acetylsalicylic acid (r2=0.9988), paracetamol (r2=0.9990) and caffeine (r2=0.9990), respectively. Intermediate precision (RSD interday) as low as 0.1-0.8% was found for retention times, while the RSD values for the peak area ratios (Aanalyte/AIS) were in the range of 1.9-2.9%. The optimized CEC method was applied to the analysis of the studied compounds present in commercial tablets.

Acetaminophen↗

Separation and characterisation of sphingoceramides by high-performance liquid chromatography-electrospray ionisation mass spectrometry.

We developed a simple and reliable analytical method for the quantification and the characterization of ceramides extracted from biological samples by high-performance liquid chromatography (HPLC) coupled to electrospray ionisation tandem mass spectrometry (ESI/MS/MS). The chromatographic separation of analytes was carried out in a RP8 column, eluting with a methanol-water mixture in gradient elution mode. The separated lipids were detected by total ion monitoring and characterised by MS/MS spectra; quantitative analysis was performed by integrating the extracted ion peaks obtained in the negative ion mode. Good repeatability was obtained for retention time (0.3-2%), peak area ratio (A(S)/A(IS), 2-8%), as well as limit of detection (LOD, 5-26 pg) and quantification (LOQ, 13-53 pg). The method was validated for the analysis of N-palmitoyl-D-erythro-sphingosine (Cer16), N-stearoyl-D-erythro-sphingosine (Cer18), N-tetracosanoyl-D-erythro-sphingosine (N24:0, lignoceric ceramide, Cer24:0), and N-tetracos-15'-enoyl-D-erythro-sphingosine (N24:1, nervonic ceramide, Cer24:1), giving good results. Lipid mixtures, extracted from skin and epidermal cells, were analysed for their content of the studied ceramides.

Ceramides↗

Enantiomeric separation of chlorophenoxy acid herbicides by nano liquid chromatography-UV detection on a vancomycin-based chiral stationary phase.

Enantiomeric separation of mecoprop, dichlorprop, and fenoprop herbicides in their acid form, commonly used to control the growth of broad-leaved weeds, was carried out by nano-liquid chromatography (nano-LC) at a flow rate of 60 nL/min, using a packed capillary column with vancomycin-modified silica particles of 5 microm. The length of chiral stationary phase was 21 cm, while the total and effective lengths were 43 and 33cm, respectively. Inner diameter was 0.075 mm. Separated peaks were detected at 195 nm. Several mixtures of methanol, water, and 500 mM ammonium acetate buffer at different pH's were tested as mobile phase, and experimental parameters such as resolution (Rs), capacity factor (k), efficiency (N/m), and enantioselectivity factor (alpha) were measured under all the test conditions. Baseline enantiomeric separation was obtained for the three studied herbicides with alpha in the range 1.6-1.9, using as the mobile phase aqueous solutions containing 85% methanol, 5% of 500mM ammonium acetate pH4.5 buffer, and 10% water. Experimental results show that the vancomycin stationary phase presents a great enantiorecognition capability towards chlorophenoxy acid herbicides on using nano-LC.

Chromatography, Liquid↗

Enantiomeric separation of acidic compounds of pharmaceutical interest by capillary electrochromatography employing glycopeptide antibiotic stationary phases.

Enantiomeric separation of some selected acidic compounds of pharmaceutical interest belonging to the group of non-steroidal anti-inflammatory drugs were separated by capillary electrochromatography employing silica based glycopeptide antibiotic stationary phases, namely vancomycin or a teicoplanin derivatives (Hepta-Tyr). The vancomycin stationary phase allowed to achieve the chiral resolution of some racemic studied compounds only using mobile phases containing ammonium formate at a relatively low pH 2.5-3.5 and acetonitrile. Employing the teicoplanin derivative stationary phase, good enantiomeric resolution was achieved eluting with mobile phases containing sodium phosphate pH 6-acetonitrile. Enantiomers were moved to the detector because a relatively high reversed electroosmotic flow (due to the positive charge of the stationary phase) and to the electrophoretic mobility of analytes.

Acids↗

Medium effect (transfer activity coefficient) of methanol and acetonitrile on beta-cyclodextrin/benzoate complexation in capillary zone electrophoresis.

Association constants, Kc, were derived from the electrophoretic mobilities of the anionic solutes (seven benzoates with hydroxy or chloro substituents) by capillary zone electrophoresis in different solvent systems, consisting of binary mixtures of water with up to 20% (v/v) methanol or acetonitrile, respectively. The association constants expectedly are found to decrease with increasing organic solvent concentration. The effect of organic solvents on the Kc of the benzoates with beta-cyclodextrin was analyzed applying the concept of the transfer activity coefficient (or the medium effect). This concept enables the evaluation of the significance of the contributions of the individual species involved in the complexation equilibrium in the different solvents: the benzoate ion, beta-cyclodextrin, and the anionic benzoate-beta-cyclodextrin complex. The medium effect on benzoate was calculated from the change in acidity constant of benzoic acid in the different mixed solvents and the corresponding transfer activity coefficients of the proton and the molecular acid. The transfer activity coefficients for beta-cyclodextrin results from its solubility at saturation in the different solvents. In this way, an estimation of the standard free energy of transfer, deltaG(t)0, of each species involved in the complexation equilibrium was possible for the transfer from water into the respective mixed solvent. It was found that the organic solvents do not significantly affect deltaG(t)0 for the benzoate anion. However, the organic solvents play a different role concerning the stabilization of beta-cyclodextrin and the complex anion: whereas the addition of acetonitrile has nearly no influence on deltaG(t)0 of the anionic complex, the reduction in Kc is caused by the enhanced stabilization of beta-cyclodextrin (reflected by its better solubility). Addition of methanol, on the other hand, lowers the solubility of beta-cyclodextrin, thus giving positive values for deltaG(t)0. Thus, the overall effect on Kc in methanolic solutions must be related to the pronounced destabilization of the benzoate-beta-cyclodextrin complex.

Acetonitriles↗

Use of short-end injection capillary packed with a glycopeptide antibiotic stationary phase in electrochromatography and capillary liquid chromatography for the enantiomeric separation of hydroxy acids.

A new chiral stationary phase (CSP) was prepared by reacting MDL 63,246 (Hepta-Tyr), a glycopeptide antibiotic belonging to the teicoplanin family, with 5-microm diol-silica particles. The CSP mixed with 5-microm amino silica particles (3:1) was packed into 75-microm fused-silica capillaries for only 6.6 cm and used for electrochromatographic experiments analyzing several hydroxy acid enantiomers. A reversed electroosmotic flow carried both analytes and mobile phase towards the anode in a short time (1-3 min), being baseline resolved all the studied analytes. In order to achieve the fastest enantiomeric resolution of the studied hydroxy acids, the effect of several experimental parameters such as mobile phase composition (organic modifier type and concentration, pH of the buffer and ionic strength), capillary temperature and applied voltage on enantioresolution factor, retention time, enantioselectivity were evaluated. The packed capillary column allowed the separation of mandelic acid enantiomers in less than 72 s with resolution factor Rs=2.18 applying a voltage of 30 kV and eluting with a mobile phase composed by 50 mM ammonium acetate (pH 6)-water-acetonitrile (1:4:5, v/v). The CSP was also tested in the capillary liquid chromatography mode resolving all the studied enantiomers applying 12 bar pressure to the mobile phase [50 mM ammonium acetate (pH 6)-water-methanol-acetonitrile, 1:4:2:3, v/v)], however, relatively long analysis times were observed (12-20 min).

Acids↗

Enantiomeric separation of citalopram and its metabolites by capillary electrophoresis.

A simple and fast capillary electrophoretic method has been developed for the enantioselective separation of citalopram and its main metabolites, namely N-desmethylcitalopram and N,N-didesmethylcitalopram, using beta-cyclodextrin (beta-CD) sulfate as the chiral selector. For method optimisation several parameters were investigated, such as CD and buffer concentration, buffer pH, and capillary temperature. Baseline enantioseparation of the racemic compounds was achieved in less than 6 min using a fused-silica capillary, filled with a background electrolyte consisting of a 35 mM phosphate buffer at pH 2.5 supplemented with 1% w/v beta-CD sulfate and 0.05% w/v beta-CD at 25 degrees C and applying a voltage of -20 kV. A fast separation method for citalopram was also optimized and applied to the analysis of pharmaceutical formulations. Racemic citalopram was resolved in its enantiomers in less than 1.5 min using short-end injection (8.5 cm, effective length) running the experiments in a background electrolyte composed of a 25 mM citrate buffer at pH 5.5 and 0.04% w/v beta-CD sulfate at a temperature of 10 degrees C.

Biotransformation↗

Evaluation of teicoplanin chiral stationary phases of 3.5 and 5 microm inside diameter silica microparticles by polar-organic mode capillary electrochromatography.

Different types of fused-silica capillaries of 75 microm inside diameter (ID) were packed, namely type A and B, and evaluated for the direct resolution of racemates of several basic compounds by enantioselective capillary electrochromatography (e-CEC). Type A was packed with a chiral stationary phase (CSP) containing teicoplanin (TE) mixed with silica microparticles (3:1 w/w) while type B contained only the TE-CSP. In both cases, particles of different sizes (3.5 and 5 microm ID) were employed. A polar-organic mobile phase containing methanol-acetonitrile (60-40% v/v and 0.05% w/v ammonium acetate was used. Several beta-blockers (alprenolol, oxprenolol, metoprolol, pindolol, salbutamol, propranolol, atenolol, acebutolol) were baseline-enantioresolved with both capillary types, in very short times.

Acetates↗

A glycopeptide antibiotic chiral stationary phase for the enantiomer resolution of hydroxy acid derivatives by capillary electrochromatography.

Separation of hydroxy acid enantiomers was achieved by using capillary electrochromatography (CEC) employing a chiral stationary phase (CSP) based on MDL 63,246 (Hepta-Tyr), a macrocyclic antibiotic of the teicoplanin family. The chiral selector was chemically bonded to 5 num diol-modified silica particles and the CSP mixed with amino silica (3:1 w/w) was packed into a 75 num ID fused-silica capillary. The CEC experiments were carried out by using an aqueous reversed-phase mode for the enantiomeric resolution of hydroxy acid compounds. Good enantioresolution was achieved for mandelic acid (MA), m-hydroxymandelic acid (m-OH-MA), p-OH-MA, and 3-hydroxy-4-methoxymandelic acid (3-OH-4-MeO-MA). The CEC system was less enantioselective towards 2-phenyllactic acid (2-PhL) and 3-PhL while mandelic acid methyl ester (MA-Et-Est) enantiomers were not resolved. Several experimental parameters, such as organic solvent type and concentration, buffer pH, capillary temperature, on enantioresolution factor, retention time, and retention factor were studied.

Acetonitriles↗

Separation of delta-, gamma- and alpha-tocopherols by CEC.

In this study capillary electrochromatography (CEC) was used for the separation of three tocopherols (TOHs), namely delta-, gamma- and alpha-TOH and the antioxidant compound, butylated hydroxytoluene (BHT). The CEC experiments were carried out using an octadecylsilica (ODS) stationary phase packed, in our laboratory, in a fused-silica capillary (100 microm I.D., 365 microm O.D. x 33 cm of total length and 24.6 or 8.4 cm effective length). The mobile phase was composed by a mixture of methanol (MeOH) and acetonitrile (ACN), at different concentrations and 0.01% (w/v) of ammonium acetate. Retention time (t(R)), retention factor (k), resolution (R(s)) of the three TOHs were strongly influenced by the organic solvent composition of the run buffer and by the effective length of the capillary. Optimum experimental conditions were found even employing the short effective length of the capillary achieving the baseline separation of the studied analytes in a relatively short time (less than 5 min). The optimized method was applied to the qualitative analysis of vitamin E (alpha-TOH) present in a human serum extract.

Antioxidants↗

Use of vancomycin silica stationary phase in packed capillary electrochromatography: III. enantiomeric separation of basic compounds with the polar organic mobile phase.

The separation of basic compounds into their enantiomers was achieved using capillary electrochromatography in 50 or 75 microm inner diameter (ID) fused-silica capillaries packed with silica a stationary phase derivatized with vancomycin and mobile phases composed of mixtures of polar organic solvents containing 13 mM ammonium acetate. Enantiomer resolution, electroosmotic flow, and the number of theoretical plates were strongly influenced by the type and concentration of the organic solvent. Mobile phases composed of 13 mM ammonium acetate dissolved in mixtures of acetonitrile/methanol, ethanol, n-propanol, or isopropanol were tested and the highest enantioresolutions were achieved using the first mobile phase, allowing the separation of almost all investigated enantiomers (9 from 11 basic compounds). The use of capillaries with different ID (50 and 75 microm ID) packed with the same chiral stationary phase revealed that a higher number of theoretical plates and higher enantioresolution was achieved with the tube with lowest ID.

Acetonitriles↗

Separation of reboxetine enantiomers by means of capillary electrophoresis.

The novel antidepressant reboxetine, a selective norepinephrine reuptake inhibitor, is increasingly used in the treatment of different forms of major depression. Reboxetine is a chiral compound, and is marketed as a racemic mixture of (R,R)- and (S,S)-reboxetine; however, the pharmacokinetic and toxicological profiles of the two enantiomers are rather different. For this reason, a simple capillary electrophoretic method for the separation of reboxetine enantiomers has been developed. Sulfobutyl ether-beta-cyclodextrin was chosen as the chiral selector, and several parameters, such as cyclodextrin and buffer concentration, buffer pH and capillary temperature were investigated in order to obtain good separation and acceptable run times. Using an uncoated, fused-silica capillary (internal diameter 50 microm, total length 48.5 cm, effective length 40.0 cm) and a background electrolyte consisting of a pH 3.0, 100 mM phosphate buffer containing 1.25 mM cyclodextrin, reboxetine enantiomers were baseline separated (resolution > 4) with a voltage of 20 kV in less than 16 min. Since pure enantiomers of reboxetine were not available, they were obtained from the racemic powder by means of direct-phase, high-performance liquid chromatography and their identity confirmed by circular dichroism spectra.

2-Hydroxypropyl-beta-cyclodextrin↗

Enantioseparation of amino acid derivatives by capillary zone electrophoresis using vancomycin as chiral selector.

The separation of racemic derivatized amino acids (N-acetyl) into their enantiomers was achieved using capillary zone electrophoresis employing vancomycin as a chiral selector. Due to the strong absorption properties of the chiral selector at the low wavelengths used, the partial-filling countercurrent method was adopted in order to improve method sensitivity. In the separation system studied, the chiral selector filled only a part of the capillary and, due to the appropriate selection of the pH, was moving in the opposite direction of the analytes keeping the detector free from absorbing compounds. The effect of several experimental parameters on the enantioresolution of analytes was studied, e.g., vancomycin concentration (0-5 mM), pH of the background electrolyte (pH 4-7), capillary temperature (15-35 degrees C), and the presence of an organic modifier in the run buffer (methanol or ethanol or n-propanol). N-Acetyl glutamic acid, serine, cystine, tyrosine, and proline were all baseline-resolved into their enantiomers and the enantioresolution factor (R(s)) was increased by raising the vancomycin concentration. pH 4 allowed the baseline resolution of the five studied analytes in the presence of 2.5 mM of chiral selector and an increase in pH caused a decrease of R(s).

Amino Acids↗