Estimation-induced correlations of the Zernike coefficients of the eye aberration.

The statistical properties of the estimated eye aberrations differ in general from the actual ones owing to the cross coupling and aliasing generated in the estimation process. In particular, the estimated Zernike aberration coefficients may show fictitious correlations that are not present in the incoming wavefronts. This fact should be taken into account when analyzing estimated aberration datasets, searching for correlations related to physiological eye features. We give an analytical model for this effect and evaluate its magnitude for a particular example, assuming that the true aberration statistics follows a Kolmogorov power law.

Journal Article↗

Direct transformation of Zernike eye aberration coefficients between scaled, rotated, and/or displaced pupils.

In eye aberrometry it is often necessary to transform the aberration coefficients in order to express them in a scaled, rotated, and/or displaced pupil. This is usually done by applying to the original coefficients vector a set of matrices accounting for each elementary transformation. We describe an equivalent algebraic approach that allows us to perform this conversion in a single step and in a straightforward way. This approach can be applied to any particular definition, normalization, and ordering of the Zernike polynomials, and can handle a wide range of pupil transformations, including, but not restricted to, anisotropic scalings. It may also be used to transform the aberration coefficients between different polynomial basis sets.

Computer Simulation↗

A new calibration set of phase plates for ocular aberrometers.

PURPOSE: To manufacture and test a set of phase plates for the calibration of ocular aberrometers and apply it to the calibration of an ocular laser ray tracing aberrometer. METHODS: The set of phase plates is made by a greyscale single-mask photosculpture in photoresist method. Each plate induces a given amount of a particular aberration (Zernike) mode. The set contains two subsets: 1) pure Zernike modes to test the accuracy among different orders (from 3rd to 7th, approximately 0.3 to 0.4 microm); and 2) plates having different amounts of the same mode, 3rd order coma ranging from 0.11 to 0.47 microm. After manufacturing, the plates were tested twice, as a crosscheck, measuring the aberration pattern of each plate with a Mach-Zehnder interferometer and a single-pass Hartmann-Shack wavefront sensor. The set was then applied to the calibration of an ocular double-pass laser ray tracing aberrometer. RESULTS: Close agreement was found between the three types of measurement. The maximum difference between Hartmann-Shack and laser ray tracing measurements was 0.032 microm (ie, approximately lambda/20, half of the typical measuring error in human eyes). This permitted detection of a small bias in the ocular laser ray tracing aberrometer. CONCLUSIONS: The calibration set may be a powerful tool for the assessment of accuracy and reliability in ocular aberrometry. It discovered a small bias, which is almost impossible to detect when working with human eyes or trial lenses. This type of calibration tool is especially important in clinical environments.

Calibration↗

Presbyopia compensation with a quartic axicon.

PURPOSE: The purpose of this study was to evaluate the performance of quartic axicons for presbyopia compensation. The working principle relies on profiting the high depth of focus of the axicons to supplement the reduced accommodation amplitude of presbyopes. METHODS: We present the design equations of a particular kind of axicon to compensate a general presbyopia condition using simultaneous vision. A rotationally symmetric polynomial of fourth-order, corresponding to the well-known Seidel spherical aberration term, was chosen as its refractive profile. To validate its performance, we computed the retinal images with Stiles-Crawford apodization for a presbyopic eye compensated with this quartic axicon and compared them with those obtained without compensation or with other available solutions based on the simultaneous vision principle. RESULTS: The quartic axicon provides an important improvement of the image quality for intermediate distance vision in comparison with conventional bifocal and trifocal solutions. The image quality, however, is still not optimum for all distances. CONCLUSIONS: The results show the usefulness of the proposed approach and point out the need for developing further adapted optimizations.

Accommodation, Ocular↗

Variable aberration generators using rotated Zernike plates.

The rotational properties of Zernike polynomials allow for an easy generation of variable amounts of aberration using two rotated phase plates, each one encoding one or several Zernike modes. This effect may be used to build variable aberration generators useful for calibrating different kinds of aberrometer.

Journal Article↗

Wide-field compensation of monochromatic eye aberrations: expected performance and design trade-offs.

The optical quality of the human eye varies across the visual field. Hence an exact compensation of the eye aberration for a given field point can give rise to a less-than-optimum compensation in neighboring field regions. We have studied some aspects of this problem and present here an approach to design wide-field (< 10 degrees) optically thin correcting elements, e.g., phase plates, deformable mirrors, and liquid-crystal displays. Their expected performance is assessed using actual eye aberration data. Particular attention is given to the design of elements providing a minimum averaged rms residual aberration and those providing a nearly uniform rms residual aberration across a given field.

Color Vision Defects↗

Measuring eye aberrations with Hartmann-Shack wave-front sensors: should the irradiance distribution across the eye pupil be taken into account?

A usual approximation in Hartmann-Shack aberrometry is that the centroid displacements are proportional to the spatial averages of the wave-front slopes at the sampling subapertures. However, these spatial averages are actually weighted by the local irradiance distribution across each microlens. The irradiance across the eye pupil is not uniform in usual reflectometric aberrometers, which is due to several factors including retinal scattering and cone waveguiding directionality. It is shown that neglecting this fact in usual least-squares reconstruction procedures gives rise to a biased estimation of the aberration coefficients. The magnitude of this bias depends on the actual irradiance distribution across the eye pupil, the mode being estimated, the detailed modal composition of the aberrated wave front, and the geometry of the wave-front sampling array. Order-of-magnitude calculations suggest that this bias may well be in the range 5%-10% for relatively smooth irradiance distributions. The systematic nature of this error makes it advisable to check for its presence and, if required, to compensate for it by an adequate choice of the least-squares reconstruction matrix.

Humans↗