Development of LiF:Mg,Cu,Si TL material (new KLT-300) with a low-residual signal and high-thermal stability.

LiF-based thermoluminescence (TL) materials have been widely used for radiation dosimetry due to their attractive features. LiF:Mg,Cu,P is one of the most sensitive tissue-equivalent TL materials, approximately 40 times more sensitive than LiF:Mg,Ti (TLD-100), but it has two main drawbacks: a thermal loss of the TL sensitivity when annealed at temperatures>240 degrees C, and a relatively high-residual signal. Recently, LiF:Mg,Cu,Na,Si TL material was developed to overcome these drawbacks at the Korea Atomic Energy Research Institute, but it provided only marginal improvements in reducing the residual signal. The newly developed LiF:Mg,Cu,Si TL material has a significantly lower residual signal and a better stability to thermal treatments. In this article, the preparation method and some dosimetric properties (sensitivity and residual signal) of the new LiF:Mg,Cu,Si TL material are presented. At the end of the preparation procedures, a dual-step annealing method is introduced and this has proved as a very efficient method to reduce the high-temperature peak and is the cause of residual signal. Therefore, the high-temperature peak in the glow curve was significantly reduced. The sensitivity is approximately 20 times higher than that of TLD-100 and the residual signal was estimated to be approximately 0.04%.

Dose-Response Relationship, Radiation↗

Thermoluminescence emission spectra for the LiF:Mg,Cu,Na,Si thermoluminescent materials with various concentrations of the dopants (3-D measurement).

The thermoluminescence (TL) emission spectra from LiF TL materials, called KLT-300 (LiF:Mg,Cu,Na,Si) with various dopant concentrations are measured and analysed. These KLT-300 materials were developed by the Korea Atomic Energy Research Institute (KAERI) to achieve an enhancement of the thermal stability in TL readings. Six types of samples are prepared with different dopant concentrations in the following ranges; Mg (0-0.20 mol%), Cu (0-0.05 mol%), Na and Si (0-0.9 mol%). The spectra measurements are carried out for the six types of samples using a TL emission spectra measurement device. The spectra measurement device consists of a monochromator, photomultiplier tube and temperature control unit to thermally stimulate the samples. The measured data shows the light emission during heating of the sample as a function of temperature and wavelength (three-dimensional TL spectra). The spectra were analysed using a method of deconvolution based on gaussian curve. The wavelength of a main peak of the emission spectra changes depending on the existence of the Cu dopant, while intensity of the spectra rapidly changes with the Cu dopant concentrations. The 385 nm emission is mainly observed in all the spectra from the samples with the Cu dopant, but in those from the samples without the Cu dopant a very weak 401 nm emission is mainly observed. However, any change in the wavelength at a main peak of the TL emission spectra from the sample materials with Na and Si dopants is not observed but that in the intensity at a peak of the spectra is observed.

Combinatorial Chemistry Techniques↗

Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) have performed thermoluminescence dosimetry (TLD) audits to verify the calibration of the beams by TL powder, but TL pellets were used in this study because the element correction factor (ECF), defined as the factor to correct the variations that all TL dosemeters cannot be manufactured to have exactly the same TL efficiency, for each TL pellet could be accurately derived and be handled conveniently when compared with the powder. Also several works for the energy response of the TLDs were done for the low-energy photon beams up to 60Co, but they will be extended in this experiment to the high photon energies (up to 20 MV), which are widely used in the therapy level of a radiation. The PTW 30006 ionisation chamber was calibrated by the Korea primary standards to establish the air-kerma rates and the TL pellets were irradiated in a specially designed waterproof pellet holder in a water phantom (30 x 30 x 30 cm3) just like the IAEA postal audits programme. This result was compared with that of another type of phantom [10 (W) x 10 (L) x 10 (H) cm3 PMMA Perspex phantom for the 60Co and 6 MV photon, and 10 x 10 x 20 (H) cm3 for the 10 and 21 MV photon] for its convenient use and easy handling and installation in a hospital. The results show that the differences of the responses for the water phantom and PMMA Perspex phantom were negligible, which is contrary to the general conception that a big difference would be expected. For an application of these results to verify the therapy beams, an appropriate energy correction factor should be applied to the energies and phantom types in use.

Computer Simulation↗

Monte Carlo simulation of the photon beam characteristics from medical linear accelerators.

The MCNPX code has been employed on a personal computer to calculate the dosimetric characteristics of the photon beams from the 6 MV Siemens MX2 and the 10 MV Varian Clinac 2100C linear accelerators. A model of the treatment head includes the major geometric structure within the beam path. The model was used to calculate the energy spectra of the photon beam, percentage depth dose and the dose profiles. The accuracy of the calculated results is examined by comparing them with the measured dose distributions for the two machines. The computed and measured depth dose curves agree to within 2% for all the depths beyond the build-up region for both treatment machines. The calculations agree to within 2% of the measured profiles within the 100-50% dose level. It has been found that the MCNPX code is an effective tool for simulating the clinical photon beam.

Body Burden↗

Pharmacokinetics of muraglitazar (BMS-298585), a dual peroxisome proliferator-activated receptors (PPAR) alpha and gamma activator, in mice, rats, dogs, and monkeys.

The pharmacokinetic parameters of muraglitazar, a novel dual-activator of the peroxisome proliferator-activated receptors (PPAR) alpha and gamma, were determined in mice, rats, dogs, and monkeys after intravenous and oral administration. In the mouse, rat, and monkey the absolute oral bioavailability of muraglitazar ranged from 64 to 88%, and in the dog oral bioavailability was approximately 18%. The systemic clearance values of muraglitazar in the mouse, rat, dog, and cynomolgus monkey were 1.2, 3.0, 12.3 and 1.2 ml min-1 kg-1, respectively. The terminal elimination half-life was 2.4 h in dogs and 7.3 h in rats. The terminal elimination half-life could not be determined in the mouse and monkey because the sampling interval did not adequately cover the terminal elimination phase. Muraglitazar appears to be distributed outside of the vasculature, with the steady-state volume of distribution being approximately twofold that of the vascular volume in rats and dogs, and approximately twofold that of the total body water in mice. The systemic plasma clearance of muraglitazar in humans was predicted to be approximately 12-14 ml min-1 kg-1 based on allometry or by scaling of in vitro clearance parameters. Overall, the pharmacokinetic parameters of muraglitazar in preclinical species were acceptable for the advancement of the compound as a clinical candidate.

Administration, Oral↗

Healthy-side dominance of middle- and long-latency neuromagnetic fields in idiopathic sudden sensorineural hearing loss.

Any lesion along the neural axis may induce a subsequent functional reorganization at the level above. The present study used magnetoencephalography to investigate auditory-evoked magnetic fields [a component of the middle-latency auditory evoked fields peaking at approximately 50 ms (P50m) and a component of the long-latency auditory evoked fields peaking at approximately 100 ms (N100m)] on stimulation of both healthy and affected ears in patients with acute unilateral idiopathic sudden sensorineural hearing loss (ISSNHL) of moderate degree in order to elucidate the functional plasticity of the auditory system. Sixteen right-handed, previously untreated adult patients with acute unilateral left (n = 8) or right (n = 8) ISSNHL of moderate degree were studied. Sixteen right-handed healthy volunteers with normal hearing served as control. Auditory neuromagnetic responses, measured by a whole-head 306-channel neuromagnetometer, were detected by monaural tone stimulation applied to affected and healthy ears, respectively, in different sessions. Intragroup and intergroup interhemispheric differences of peak dipole strengths and latencies of P50m and N100m, respectively, to monaural tones were evaluated. Healthy-side amplitude dominance of both P50m and N100m was found in ISSNHL, i.e. contralateral dominance was preserved on affected-ear stimulation but ipsilateral dominance was seen on healthy-ear stimulation. The phenomena could be attributed to the combined contralateral attenuation and ipsilateral enhancement of P50m and N100m activity in response to healthy-ear stimulation. Our findings confirmed that functional modulation can occur within the first few tens of milliseconds of evoked response at the auditory cortex in ISSNHL. The mechanisms of healthy-side dominance might be ascribed to a functional retune of auditory pathways, i.e. conjoined contralateral inhibition and ipsilateral excitation of the auditory pathway in response to healthy-ear stimulation. The effect could be registered in cortical responses.

Acoustic Stimulation↗

Ground-state properties of Fermi gases in the strongly interacting regime.

The ground-state energies and pairing gaps in dilute superfluid Fermi gases have now been calculated with the quantum Monte Carlo method without detailed knowledge of their wave functions. However, such knowledge is essential to predict other properties of these gases such as density matrices and pair distribution functions. We present a new and simple method to optimize the wave functions of quantum fluids using the Green's function Monte Carlo method. It is used to calculate the pair distribution functions and potential energies of Fermi gases over the entire regime from atomic Bardeen-Cooper-Schrieffer superfluid to molecular Bose-Einstein condensation, spanned as the interaction strength is varied.

Journal Article↗

On the roles of the dopants in LiF: Mg,Cu,Na,Si thermoluminescent material.

In this paper, some results of the study on the roles of the dopants in the LiF:Mg,Cu,Na,Si thermoluminescent (TL) material that was developed at the Korea Atomic Energy Research Institute for radiation protection are presented. Although there have been many studies to investigate the roles of the dopants in LiF:Mg,Cu,P TL material in the TL process, there are some discrepancies in the understanding of the roles of Cu and P between various researchers. In case of LiF:Mg,Cu,Na,Si TL material, there are a few studies on the roles of the dopants. Three kinds of samples in each of which one dopant is excluded, and the optimised sample, were prepared for this study. The measurements and analysis of the three-dimensional TL spectra, based on the temperature, wavelength and intensity, and the glow curves for those samples are used in this study. The results show that Mg plays a role in the trapping of the charge carriers and Cu plays a role in the luminescence recombination process; however, the effect of Na and Si on the glow curve structure and the TL emission spectra is much less than that of Mg and Cu. It is considered that Na and Si each plays a role in the improvement of the luminescence efficiency.

Dose-Response Relationship, Radiation↗

A computer program for the deconvolution of thermoluminescence glow curves.

A quick and efficient computer program was developed in order to resolve the peaks from the thermoluminescence (TL) glow curve. The program was designed to be easily used on any MS Windows-based computer with a graphical user interface. In this program, a new method based on the general one-trap TL equation was adopted to analyse the TL glow curve with the traditional first-order, second-order and general-order kinetics model. The method described here, general approximation, generates TL glow peaks and interpolates the relevant TL parameters from the glow data. The program was tested with simulated and experimental TL glow data and the results were found to be adequate and reliable.

Algorithms↗

Developments in the synthesis of LiF:Mg,Cu,Na,Si TL material.

A procedure for synthesis of the highly sensitive pellet-type LiF:Mg,Cu,Na,Si thermoluminescent (TL) detector has been newly developed. It was found that the optimum concentrations of dopants for a pellet-type LiF:Mg,Cu,Na,Si TL detector were found to be Mg: 0.2 mol %, Cu: 0.05 mol %, Na: 0.9 mol%, and Si: 0.9 mol%. The TL sensitivity of this new detector was about 30 times higher than that of the TLD-100 by light integration measurements. Reusability study of the detector was carried out for 10 cycles. The results show that the coefficients of variation for each detector separately did not exceed 0.016, and that for all 10 detectors collectively was 0.0054.

Copper↗

Measurement of the neutron fluence and dose spectra using an extended bonner sphere and a tissue-equivalent proportional counter.

A conventional Bonner Sphere (BS) set consisting of six polyethylene spheres was modified to enhance its response to a high-energy neutron by putting a lead shell inside a polyethylene moderator. The response matrix of an extended BS was calculated using the MCNPX code and calibrated using a 252Cf neutron source. In order to survey the unknown photon and neutron mixed field, a spherical tissue equivalent proportional counter (TEPC) was constructed and assembled as a portable measurement system. The extended BS and the self-constructed TEPC were employed to determine the dosimetric quantities of the neutron field produced from the thick lead target bombarded by the 2.5 GeV electron beam of Pohang Accelerator Laboratory (PAL) and the neutron calibration field of Korea Atomic Energy Research Institute (KAERI).

Body Burden↗

Pharmacokinetics of desflurane uptake into the brain and body.

The aim of this study was to investigate the pharmacokinetics of desflurane uptake into the brain and body by comparing desflurane concentrations in internal jugular-bulb blood (Jdes), arterial blood (Ades) and pulmonary arterial blood (PAdes) at a fixed inspired desflurane concentration. Thirteen patients (aged 42-72 years) undergoing coronary artery bypass grafting surgery were enrolled in this study. They were anaesthetised using a constant 5% inspired desflurane concentration (CIdes) during the first hour of anaesthesia. Under constant volume-controlled ventilation, CIdes and end-tidal desflurane (CEdes) were measured with an infrared analyser. The desflurane concentration in the blood was analysed using gas chromatography, and cardiac output was measured using an Opti-Q pulmonary artery catheter. It took 24 min for the Jdes to equilibrate with Ades. Both CIdes-CEdes and Ades-PAdes gradients persisted during the study period. There was no further uptake of desflurane into the brain after 24 min but there was near-constant uptake into the body.

Adult↗

Thermoluminescence characteristics of teflon embedded CaSO4:Dy TLD.

The Korea Atomic Energy Research Institute (KAERI) is manufacturing CaSO4:Dy Teflon TL pellets which have more sensitivity and stability than commercial TLD. A method is presented of preparing the CaSO4:Dy phosphor-embedded Teflon powder, which is then compressed to a thin pellet form used as the TLD element. Investigations are made to determine optimum preparation conditions and dosimetric characteristics of the CaSO4:Dy Teflon pellet such as the sensitivity, energy response, dose response, fading, re-usability, and lowest level of detection. The results show that the sensitivity of the CaSO4:Dy pellet is 2 times higher than that of the commercial Teledyne CaSO4:Dy pellet. A dose-response was observed to be linear in the range from 10(-5) to 10 Gy. The relative energy response in the low energy region was 9.6 (normalised to the 137Cs gamma source), and the fading rate was about 10% for five months. The re-usability was estimated to be more than 60 cycles, and the low level of detection dose was 22 microGy. From the results, the CaSO4:Dy pellet developed in KAERI can be successfully used in personal dosemeters through appropriate filter design for compensating the energy response.

Calcium Sulfate↗

Analysis of the glow curves obtained from LiF:Mg,Cu,Na,Si TL material using the general order kinetics model.

Three-dimensional thermoluminescence (TL) spectra based on temperature, wavelength and intensity for newly developed LiF:Mg,Cu,Na,Si TL material at the Korea Atomic Energy Research Institute (KAERI) were measured and analysed. The glow curves were obtained by integration of luminescence intensity over all wavelengths at each temperature, and various trapping parameters related to the traps were determined by analysing these curves. A computerised glow curve deconvolution (CGCD) method which was based on the general order kinetics (GOK) model was used for the glow curve analysis. The glow curves of LiF:Mg,Cu,Na,Si TL material were deconvoluted to six isolated glow curves which have peak temperatures at 333, 374, 426, 466, 483 and 516 K. The main glow peak of peak temperature at 466 K had activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centres, 1.80 eV, 2.88 eV and 3.27 eV by analysis of the TL spectra.

Copper↗

Comparison of TLD algorithms for monochromatic fluorescent radiation and continuous spectrum X rays.

A personal dosimetry system is required to measure the personal dose equivalent accurately in a wide range of radiation fields. However, the dose evaluation algorithm at the Korea Atomic Energy Research Institute (KAERI) has been developed with the spectral X ray fields described in the American National Standards Institute (ANSI) Standard N13.11 and the actual fields to be monitored may be significantly different from these. To evaluate the dose more accurately when workers are exposed to non-ANSI N13.11 radiation fields, a dose evaluation algorithm using monochromatic radiation (monochromatic algorithm) was developed using the experimental data of the energy responses of CaSO4:Dy thermoluminescent materials irradiated by monochromatic fluorescent X ray fields recently established at KAERI; this was compared with another algorithm developed on the basis of the ANSI N13.11 continuous spectrum X ray fields (spectrum algorithm). The paper concludes with discussions about some results of the algorithm test, including mixed field irradiation and angular response, conducted in an International Atomic Energy Authority/Regional Cooperation of Asia (IAEA/RCA) intercomparison study.

Algorithms↗

Human immunodeficiency virus type 1 subtype C molecular phylogeny: consensus sequence for an AIDS vaccine design?

An evolving dominance of human immunodeficiency virus type 1 subtype C (HIV-1C) in the AIDS epidemic has been associated with a high prevalence of HIV-1C infection in the southern African countries and with an expanding epidemic in India and China. Understanding the molecular phylogeny and genetic diversity of HIV-1C viruses may be important for the design and evaluation of an HIV vaccine for ultimate use in the developing world. In this study we analyzed the phylogenetic relationships (i) between 73 non-recombinant HIV-1C near-full-length genome sequences, including 51 isolates from Botswana; (ii) between HIV-1C consensus sequences that represent different geographic subsets; and (iii) between specific isolates and consensus sequences. Based on the phylogenetic analyses of 73 near-full-length genomes, 16 "lineages" (a term that is used hereafter for discussion purposes and does not imply taxonomic standing) were identified within HIV-1C. The lineages were supported by high bootstrap values in maximum-parsimony and neighbor-joining analyses and were confirmed by the maximum-likelihood method. The nucleotide diversity between the 73 HIV-1C isolates (mean value of 8.93%; range, 2.9 to 11.7%) was significantly higher than the diversity of the samples to the consensus sequence (mean value of 4.86%; range, 3.3 to 7.2%, P < 0.0001). The translated amino acid distances to the consensus sequence were significantly lower than distances between samples within all HIV-1C proteins. The consensus sequences of HIV-1C proteins accompanied by amino acid frequencies were presented (that of Gag is presented in this work; those of Pol, Vif, Vpr, Tat, Rev, Vpu, Env, and Nef are presented elsewhere [http://www.aids.harvard.edu/lab_research/concensus_sequence.htm]). Additionally, in the promoter region three NF-kappa B sites (GGGRNNYYCC) were identified within the consensus sequences of the entire set or any subset of HIV-1C isolates. This study suggests that the consensus sequence approach could overcome the high genetic diversity of HIV-1C and facilitate an AIDS vaccine design, particularly if the assumption that an HIV-1C antigen with a more extensive match to the circulating viruses is likely to be more efficacious is proven in efficacy trials.

AIDS Vaccines↗

The application of intramolecular radical cyclizations of acylsilanes in the regiospecific formation of cyclic silyl enol ethers.

Acylsilanes with terminal alpha-stannyl bromide or xanthate functionalities are prepared. Alpha-stannyl radicals generated from these acylsilanes undergo intramolecular cyclizations to give cyclic silyl enol ethers regiospecifically. The radical processes involve radical cyclization, Brook rearrangement, and beta-fragmentation in sequence. A tributylstannyl group serves as the radical leaving group. The newly formed sigma-bond and pi-bond are located between the same two carbon atoms. This approach is limited to the formation of five-membered rings. In another route, omega-bromo-alpha-phenylsulfonylacylsilanes are synthesized. The radical cyclizations of these alpha-sulfonylacylsilanes also give cyclic silyl enol ethers. The phenylsulfonyl moiety is the radical leaving group in this system. Furthermore, the newly formed sigma-bond and pi-bond are located at adjacent positions sharing a single carbon atom. The latter approach is effective for both five- and six-membered ring formation.

Journal Article↗