Feasibility and potential of MR-Colonography for evaluating colorectal cancer.

BACKGROUND: MR-Colonography (MRC) based on MR-imaging is a relatively new diagnostic modality for diagnosing colorectal polyps. The aim of this experimental study was to evaluate its performance in detecting and staging colorectal cancer. METHOD: 23 patients with proven colorectal cancer underwent MR-Colonography one day prior to operation after standard bowel preparation. The colon was filled with a diluted gadolinium enema. Coronal sections were acquired in prone and supine. Virtual colonoscopy (VC) was processed from the acquired 3D data sets and MRC was interactively analysed together with VC. The findings were correlated with colonoscopic and pathology results. RESULTS: A complete MRC was achieved in 21 patients (92%), two patients (8%) could not be conclusively evaluated due to insufficient bowel preparation or technical problems. No complications were observed. Compared to colonoscopy all 23 carcinomas were detected. No lesion > or = 8 mm was missed. In one patient a synchronous carcinoma was newly diagnosed. This lesion was missed by colonoscopy since the distal tumour was endoscopically unpassable. In total eight (33%) colonoscopies were incomplete. CONCLUSION: MRC offers a new and promising diagnostic tool for colorectal cancer. It is particularly valuable when colonoscopy is incomplete. It improves preoperative planning and it holds the potential as an all-in-one investigation including local and liver staging in combination with conventional MRI.

Aged↗

Fetus and uteroplacental unit: fast MR imaging with three-dimensional reconstruction and volumetry--feasibility study.

In 22 fetuses, three-dimensional reconstruction was performed on the basis of T2-weighted magnetic resonance (MR) data sets by using a surface-rendering technique. Fetuses and uteroplacental units were segmented manually; volumes were calculated automatically. Three-dimensional reconstruction and volumetry of the fetus and uteroplacental unit are feasible with MR data sets. MR estimates correlated closely with ultrasonographic fetal biometric estimates and birth weight.

Adult↗

Effects of lung volume reduction surgery for emphysema on diaphragm dimensions and configuration.

Part of the functional benefit provided by lung volume reduction surgery (LVRS) may be related to improvement in respiratory muscle function resulting from changes in diaphragm dimension and configuration. To study these changes, we obtained 3D reconstructions of the muscle using spiral computed tomography in 11 patients with severe emphysema before and 3 mo after surgery, and in 11 normal subjects matched for sex, age, height, and weight. Bilateral LVRS was performed by thoracoscopy in eight patients and by sternotomy in three patients. Acquisitions were made in the supine posture at relaxed FRC, midinspiratory capacity, and TLC. On average, LVRS produced a 51 +/- 11% increase in FEV(1) and a 30 +/- 4% decrease in FRC. The total surface area of the diaphragm (A(di)) and of the zone of apposition (A(ap)) at FRC increased by 17 +/- 4% and 43 +/- 8%, respectively, but the surface area of the dome did not change. Compared with the values recorded in the normal subjects, postoperative values of A(di) and A(ap) at FRC were reduced by 11% (p < 0.05) and 24% (p < 0.005), respectively. The curvature of the dome increased at TLC in the left sagittal plane, but was otherwise unaffected by the procedure. We conclude that LVRS substantially increases A(di) and A(ap), but does not significantly improve diaphragm configuration at FRC.

Anthropometry↗

A virtual environment for simulated rat dissection.

Animal dissection for the scientific examination of organ subsystems is a delicate procedure. Performing this procedure under the complex environment of microgravity presents additional challenges because of the limited training opportunities available that can recreate the altered gravity environment. Traditional crew training often occurs several months in advance of experimentation, provides limited realism, and involves complicated logistics. We have developed an interactive virtual environment that can simulate several common tasks performed during animal dissection. In this paper, we describe the imaging modality used to reconstruct the rat in virtual space, provide an overview of the simulation environment and briefly discuss some of the techniques used to manipulate the virtual rat.

Animals↗

Prospective evaluation of delayed central nervous system (CNS) toxicity of hyperfractionated total body irradiation (TBI).

PURPOSE: Prospective evaluation of chronic radiation effects on the healthy adult brain using neuropsychological testing of intelligence, attention, and memory. METHODS AND MATERIALS: 58 patients (43 +/- 10 yr) undergoing hyperfractionated total body irradiation (TBI) (TBI, 14.4 Gy, 12 x 1.2 Gy in 4 days) before bone marrow or peripheral blood stem cell transplantation were prospectively included. Twenty-one recurrence-free long-term survivors were re-examined 6-36 months (median 27 months) after completion of TBI. Neuropsychological testing included assessment of general intelligence, attention, and memory using normative, standardized psychometric tests. Mood status was controlled, as well. Test results are given as IQ scores (population mean 100) or percentiles for attention and memory (population mean 50). RESULTS: The 21 patients showed normal baseline test results of IQ (101 +/- 13) and attention (53 +/- 28), with memory test scores below average (35 +/- 21). Test results of IQ (98 +/- 17), attention (58 +/- 27), and memory (43 +/- 28) showed no signs of clinically measurable radiation damage to higher CNS (central nervous system) functions during the follow-up. The mood status was improved. CONCLUSION: The investigation of CNS toxicity after hyperfractionated TBI showed no deterioration of test results in adult recurrence-free patients with tumor-free CNS. The median follow-up of 27 months will be extended.

Adult↗

[Proximal anastomoses of aortocoronary bypasses. Evaluation with ECG-triggered single-slice computerized tomography].

PURPOSE: Assessment of coronary artery bypass graft (CABG) patency with computed tomography methods has been demonstrated as an alternative to coronary angiography. The evaluation of the bypass anastomoses is still of limited success. Prospective ECG triggering of conventional CT scanners allows heart phase-triggered single-slice acquisition in the sub-second range. The goal of this study was to evaluate whether the use of ECG triggering can optimize the evaluation of proximal CABG anastomoses. MATERIALS AND METHODS: In ten patients after CABG surgery, ECG-triggered CT with thin (2 mm), contiguous slices was performed in the region of the proximal bypass anastomoses in the ascending aorta. The data evaluation was done on axial images and on reconstructed 2D and 3D data sets. RESULTS: The applied technique demonstrated good imaging quality, which allowed evaluation of the CABG anastomoses in all cases. Overall 18 CABG anastomoses could be visualized; 17 anastomoses could be assessed as normal, non-stenotic and patent. DISCUSSION: ECG-triggered thin-slice CT permits reliable assessment of proximal CABG anastomoses and expands the usage of CT in the evaluation of CABG.

Adult↗

Colonic masses: detection with MR colonography.

PURPOSE: To assess magnetic resonance (MR) colonography as a method for detection of colorectal masses, with conventional colonoscopy as the reference standard. MATERIALS AND METHODS: MR colonography was performed in 132 patients referred for colonoscopy because of the possible presence of a mass. After rectal filling with a gadopentetate dimeglumine and water enema, T1-weighted three-dimensional gradient-echo MR studies were acquired with the patient in the prone and supine positions. Water-sensitive single-shot fast spin-echo MR images were also obtained. Surface-rendered virtual endoscopic endoluminal views, orthogonal sections in three planes, and water-sensitive MR images were interactively assessed for presence of colorectal masses by two radiologists. RESULTS: MR colonography was well tolerated without sedation or analgesia. MR image quality was sufficient for diagnosis in 127 (96%) patients. Most small (</=5-mm-diameter) masses were overlooked at MR colonography, but 19 of 31 6-10-mm lesions and 26 of 27 large (>10-mm) lesions were correctly identified. For these large masses, MR colonography had a sensitivity of 93%, specificity of 99%, positive predictive value of 92%, and negative predictive value of 98% for detection of masses. CONCLUSION: MR colonography is a promising modality for help in detecting colorectal mass lesions larger than 10 mm in diameter.

Administration, Rectal↗

Contrast optimization for assessment of the colonic wall and lumen in MR colonography.

This report focuses on the optimization of magnetic resonance colonography for combined virtual endoluminal and T2-weighted wall analysis of the colon and demonstrates the potential of the single-shot fast spin-echo (SSFSE) sequence for identifying colorectal pathologies. A 45 degrees flip angle in the three-dimensional spoiled gradient-echo sequence and a TE of 60 msec in the SSFSE sequence in conjunction with a 10 mM gadolinium concentration in the enema results in maximal contrast for the delineation of the colonic lumen in T1-weighted imaging and the colonic wall in T2-weighted imaging. The SSFSE sequence reveals hyperintense signal for inflammatory disease and most polyps exceeding 10 mm in size. It supplements the virtual endoluminal assessment by aiding in the differentiation between mass lesions and fecal matter or residual air.

Colon↗

Virtual MR arthroscopy: new insights into joint morphology.

Evaluation of the feasibility of virtual magnetic resonance (MR) arthroscopy was performed on 10 patients referred for MR arthrography of the shoulder, the elbow, or the knee. A fast spoiled contrast-enhanced three-dimensional gradient-echo sequence was combined with image postprocessing to render arthroscopic views. Virtual MR arthroscopy was successfully demonstrated in all 10 joints. Determination of added diagnostic benefit will require further study.

Adult↗

A new filtering algorithm for medical magnetic resonance and computer tomography images.

Inner views of tubular structures based on computer tomography (CT) and magnetic resonance (MR) data sets may be created by virtual endoscopy. After a preliminary segmentation procedure for selecting the organ to be represented, the virtual endoscopy is a new postprocessing technique using surface or volume rendering of the data sets. In the case of surface rendering, the segmentation is based on a grey level thresholding technique. To avoid artifacts owing to the noise created in the imaging process, and to restore spurious resolution degradations, a robust Wiener filter was applied. This filter working in Fourier space approximates the noise spectrum by a simple function that is proportional to the square root of the signal amplitude. Thus, only points with tiny amplitudes consisting mostly of noise are suppressed. Further artifacts are avoided by the correct selection of the threshold range. Afterwards, the lumen and the inner walls of the tubular structures are well represented and allow one to distinguish between harmless fluctuations and medically significant structures.

Algorithms↗

CT angiography and Doppler sonography for emergency assessment in acute basilar artery ischemia.

BACKGROUND AND PURPOSE: Both Doppler sonography (DS) and spiral CT angiography (CTA) are noninvasive vascular assessment tools with a high potential for application in acute cerebral ischemia. The usefulness of CTA for vascular diagnosis in acute basilar artery (BA) ischemia has not yet been studied. METHODS: We prospectively studied 19 patients (mean+/-SD age, 58+/-11 years) with clinically suspected acute BA occlusion by DS and CTA. Prior extracranial and transcranial DS was performed in all but 1 patient, with DS 4 hours after CTA. In 6 of 19 patients, we performed digital subtraction angiography. RESULTS: CTA was diagnostic in all but 1 patient. CTA revealed complete BA occlusion in 9 patients and incomplete BA occlusion with some residual flow in 2 patients. A patent BA was shown in 7 patients. Because of severe BA calcification, CTA results were inconclusive in 1 patient. DS was diagnostic in only 7 of 19 patients, indicating certain BA occlusion in 3 patients and BA patency in 4 patients. In an additional 9 patients, the results of DS were inconclusive. DS was false-negative in 2 patients with distal BA occlusion shown by CTA and digital subtraction angiography. In 1 patient with DS performed after CTA, recanalization was demonstrated. In addition to the diagnosis or exclusion of BA occlusion, CTA provided information on the exact site and length of BA occlusion and collateral pathways. In our series, CTA results prompted indication for intra-arterial thrombolysis in 5 patients. CONCLUSIONS: CTA was superior to DS in the assessment of BA patency in patients with the syndrome of acute BA ischemia in terms of feasibility and conclusiveness, particularly in cases with distal BA occlusion. Our study confirmed the usefulness of combined extracranial and transcranial DS in the diagnosis and exclusion of proximal BA occlusion.

Acute Disease↗

Changes in cross-sectional measurements of the spinal canal and intervertebral foramina as a function of body position: in vivo studies on an open-configuration MR system.

OBJECTIVE: The purpose of this study was to evaluate physiologic changes of the cross-sectional area of the spinal canal and neural foramina in young asymptomatic volunteers. SUBJECTS AND METHODS: Twelve asymptomatic volunteers were examined in a 0.5-T open-configuration MR system. T2-weighted fast spin-echo sequences were obtained in upright neutral, upright flexed, upright extended, and supine extended positions. The cross-sectional area of the spinal canal and the thickness of the ligamentum flavum were measured on angled axial images at the L4-L5 level. The anteroposterior diameter of the spinal canal and cross-sectional areas of the neural foramina were measured on sagittal images from L1 to S1. RESULTS: At disk level, the cross-sectional area of the spinal canal varied significantly between body positions, most notably between the upright flexed (mean, 268 mm2) and the upright extended (mean, 224 mm2) positions (p < .0001). The maximum thickness of the ligamenta flava increased in the extended positions (p < .0001). The cross-sectional area of the neural foramina underwent position-dependent variations of as much as 44.4%. The smallest cross-sectional areas were found in the extended positions. CONCLUSION: In asymptomatic volunteers, MR imaging is able to show position-dependent changes in the cross-sectional areas of the spinal canal and the intervertebral foramina. The extended positions best reveal important findings.

Adult↗

Virtual endoscopy in abdominal MR imaging.

As illustrated in this review, the diagnostic utility of VIE is highly dependent on the individual application. Virtual intraluminal endoscopy does not alter the informational content of the data set; rather, the data is presented in a different manner. In view of the considerable time requirements still associated with the VIE rendering process, the additional diagnostic value gained by VIE must be determined for each of the potential applications. Thus VIE was shown to be of no additional value in the assessment of 3D MR angiographic data sets of the abdominal aorta and renal arteries. For MR colonography, on the other hand, in vitro experiments as well as in vivo experience have demonstrated a vast diagnostic value as a primary screen supplemented by detailed analysis of reformatted images in all three orthogonal axes. In summary, virtual intraluminal imaging is a powerful tool for exploring 3D MR data sets of various abdominal structures from a different perspective. Clearly much more work is required to determine its diagnostic utility relative to its cost.

Abdomen↗

Assessment of neuropsychological changes in patients with arteriovenous malformation (AVM) after radiosurgery.

PURPOSE: The purpose of this study was to investigate neuropsychological effects of radiosurgery in patients with cerebral arteriovenous malformation (AVM), with special focus on attention and memory. This report describes the study setup and presents the first results during a follow-up of up to 1 year. MATERIALS AND METHODS: Seventy-nine patients were studied before, acutely after radiosurgery, and during the regular follow-up (subacute phase: Weeks 6-12, chronic phase: Months 6-12). Radiosurgery was performed using a modified linear accelerator (minimum doses to the target volume: 15-22 Gy, median 20 Gy). Estimated whole brain dose was 0.5 to 2 Gy. Neuropsychological testing included assessment of general intelligence (Wechsler Adult Intelligence Scale), attention (modified Trail-Making Test A, Digit Symbol Test, D2 Test, Wiener Determination Machine) and memory (Rey Auditory Verbal Learning Test, Benton Visual Retention Test). During follow-up, alternate test versions were used. Neuropsychological deficits were defined as a test score of at least one standard deviation (SD) below the mean of the normal distribution. RESULTS: The pretherapeutic evaluation revealed marked deviations from the normal population; 24% had deficits in intelligence (range 23-31% in different subtests), attention (35%, 23-59%) and memory (48%, 31-61%). The overall percentage of aberrant results was reduced by 12% (memory) to 14% (attention) in the chronic phase up to 12 months after therapy. The improvement in test scores was significant (p < 0.05) in 3 of 4 subtests of attention functions. CONCLUSIONS: The acute tolerance of radiosurgery seems to be very good in these patients, showing no relevant increase in number of patients with neuropsychological deficits. Although the long-term follow-up needs to be further increased, our data indicate a tendency to slight improvement in the overall neuropsychological performance of AVM patients in the chronic phase after radiosurgery.

Adult↗

[Vascular applications of interventional MRI].

The flow sensitivity inherent to the MR experiment allows for the non-invasive assessment of both the arterial and venous vasculature in any desired plane with good spatial resolution. Data can be acquired in a three-dimensional form, permitting reformating in any plane. In addition, MRI is capable of providing quantitative blood flow information with the use of phase-contrast flow-mapping techniques. Ultrafast gradient echo and echoplanar data acquisition strategies even permit imaging in near-real time. The availability of open MRI configurations now permits one to take advantage of the unique imaging features inherent to MR imaging for the purpose of guidance and control of various intravascular procedures. With the recent development of the MR tracking and MR profiling techniques, permitting visualization of guide-wires and catheters relative to their surroundings in the MR environment in real time, one of the last obstacles to 'Interventional MR angiography' has in effect been overcome. In addition, MR catheters can be modified to acquire high-resolution MR images of the vascular wall, thereby opening vast possibilities regarding characterization of atherosclerotic plaques. This review introduces the underlying techniques for catheter and guide-wire visualization in the MR environment, describes preliminary interventions in animals and humans and discusses the potential of intravascular MRI.

Echo-Planar Imaging↗

[Active instrumental guidance in interventional MR tomography: introduction to a new concept].

PURPOSE: An active MR-based guidance system for visualisation of invasive instruments is described. METHODS: The principle of MR tracking is based on the integration of a miniaturised coil into the tip of the instrument itself. A phantom experiment was designed to demonstrate the localising accuracy of this technique. In addition, biocompatibility and warming effects were evaluated. Preliminary intravascular applications that were performed in animal experiments under MR guidance included embolisation, vascular occlusion as well as transjugular intrahepatic punctures. Percutaneous biopsies, cholecystostomies and laparoscopic applications were also evaluated with MR tracking. RESULTS: Phantom experiments confirmed an excellent localisation accuracy of MR tracking compared top conventional radiography. At a field strength of 0.5 T, the temperature increase remained below 2 degrees C. Results of phantom experiments revealed a potential of significant heating dependent on the sequence parameters employed. MR tracking allowed a robust, simultaneously biplanar visualisation of the instrument tips in real time. Based on MR "road map" images, various intravascular and percutaneous interventions were successfully performed in vivo under MR guidance. CONCLUSIONS: MR tracking is a flexible concept permitting monitoring in the guidance of instruments in an MR environment. Various preliminary in vitro and in vivo experiments demonstrate safety, localisation accuracy and feasibility of this biplanar localisation technique in real time.

Biopsy, Needle↗

Lumbar spine: quantitative and qualitative assessment of positional (upright flexion and extension) MR imaging and myelography.

PURPOSE: To compare measurements of the sagittal diameter of the lumbar dural sac obtained at positional magnetic resonance (MR) imaging and at functional myelography and to assess the influence of various body positions on the dural sac and the intervertebral foramina. MATERIALS AND METHODS: Thirty consecutive patients referred for lumbar myelography were examined with an open 0.5-T MR imager, Sagittal T2-weighted fast spin-echo images were acquired with patients in the supine, upright flexion, and upright extension positions. The midsagittal diameter of the dural sac was measured at the level of the disks on MR images and myelograms. Foraminal sizes on the MR images were scored independently by two observers. RESULTS: Correlation between MR imaging and myelographic measurements was high (r = .81-.97). A small but statistically significant positional dependence of the dural sac diameter was found in the lower lumbar spine. Position-dependent differences in foraminal scores were uncommon. CONCLUSION: Quantitative assessment of sagittal dural sac diameters is comparable between lumbar myelography and positional MR imaging. In a selected patient population, only small changes in the sagittal diameter of the dural sac and foraminal size can be expected between various body positions, and the information gained in addition to that from standard MR imaging is limited [corrected].

Adult↗

Role of CT angiography in patient selection for thrombolytic therapy in acute hemispheric stroke.

BACKGROUND AND PURPOSE: It has been shown that thrombolytic therapy can improve clinical outcome in a subgroup of patients with acute cerebral ischemia. This subgroup was characterized by certain clinical and imaging findings (eg, moderate to severe neurological deficit for less than 3 to 6 hours, occlusion of the middle cerebral artery, lack of extended infarct signs on CT, and efficient leptomeningeal collaterals). Although not part of published prospective randomized rtPA trials, information about the status of the brain vessels would be helpful in the selection of patients who may benefit the most. Our purpose was to determine the feasibility of CT angiography (CTA) in patients with acute hemispheric ischemia and to evaluate its relevance for thrombolytic therapy. METHODS: CTA was performed in 40 consecutive patients (11 women and 29 men; age range, 19 to 80 years) with moderate or severe symptoms (National Institutes of Health Stroke Scale score of > or =8) of acute hemispheric ischemia. CTA findings were compared with Doppler ultrasonography (US; n=22) and intra-arterial digital subtraction angiography (DSA; n=7). Twenty patients received thrombolytic therapy, the remaining patients received intravenous heparin. RESULTS: Images and 3-dimensional reconstructions of diagnostic quality could be obtained in all patients. Thirty-four patients had a vessel occlusion. The extent of leptomeningeal collaterals correlated significantly with the outcome after thrombolytic therapy (rs=0.46, P<0.05). The evaluation of diagnostic accuracy showed a high agreement with US (22 of 22) and DSA (6 of 7). CONCLUSIONS: CTA can provide important information for the initiation of therapy in patients with acute hemispheric ischemia. Identification of patients with autolyzed thrombi, occlusion of the internal carotid artery bifurcation, and poor leptomeningeal collaterals is feasible with the use of CTA. These patients may have little potential for benefit from thrombolytic therapy.

Acute Disease↗