S Vynckier

Publications and source records attributed to S Vynckier.

At least 19 recordsLinked to original sources

Dosimetric study of a new polymer encapsulated palladium-103 seed.

The use of low-energy photon emitters for brachytherapy applications, as in the treatment of prostate or ocular tumours, has increased significantly over the last few years. Several new seed models utilizing 103Pd and 125I have recently been introduced. Following the TG43U1 recommendations of the AAPM (American Association of Physicists in Medicine) (Rivard et al 2004 Med. Phys. 31 633), dose distributions around these low-energy photon emitters are characterized by the dose rate constant, the radial dose function and the anisotropy function in water. These functions and constants can be measured for each new seed in a solid phantom (i.e. solid water such as WT1) using high spatial resolution detectors such as very small thermoluminescent detectors. These experimental results in solid water must then be converted into liquid water by using Monte Carlo simulations. This paper presents the dosimetric parameters of a new palladium seed, OptiSeed (produced by International Brachytherapy (IBt), Seneffe, Belgium), made with a biocompatible polymeric shell and with a design that differs from the hollow titanium encapsulated seed, InterSource103, produced by the same company. A polymer encapsulation was chosen by the company IBt in order to reduce the quantity of radioactive material needed for a given dose rate, and to improve the symmetry of the radiation field around the seed. The necessary experimental data were obtained by measurements with LiF thermoluminescent dosimeters (1 mm3) in a solid water phantom (WT1) and then converted to values in liquid water using Monte Carlo calculations (MCNP-4C). Comparison of the results with a previous study by Reniers et al (2002 Appl. Radiat. Isot. 57 805) shows very good agreement for the dose rate constant and for the radial dose function. In addition, the results also indicate an improvement in isotropy compared to a conventional titanium encapsulated seed. The relative dose (anisotropy value relative to 90 degrees ) from the seed at a distance of 3 cm is close to 70% at 0 degrees whereas that for the titanium encapsulated InterSource103seed is close to 40%. This paper also presents some new Monte Carlo calculations relating to shadowing produced by the seeds in an array implanted for a prostate cancer treatment. Recently, Mobit and Badragan (2004 Phys. Med. Biol. 49 3171) reported shadowing resulting in a 10% decrease in dose from titanium encapsulated 125I seed. We used Monte Carlo simulations (MCNP-4C) to evaluate shadowing for the InterSource103 titanium encapsulated seed and the OptiSeed polymer encapsulated seed. For a specific geometry specified, dose decreases of 13% and 7% were found for the InterSource103 titanium encapsulated and the OptiSeed polymer encapsulated seed, respectively.

Brachytherapy↗

Theoretical analysis of microdosimetric spectra and cluster formation for 103Pd and 125I photon emitters.

In this work we have compared 125I or 103Pd from a microdosimetric point of view. The photon spectra at different positions around the seeds have first been calculated using EGSnrc Monte Carlo (MC) code. These photon spectra are used as input for the event-by-event MC code TRION to calculate the microdosimetric lineal energy (y) distribution for each isotope. The microdosimetric dose average lineal energy, yD, calculated in a sphere of 1 microm is 3.5 keV microm(-1) for 125I and 4.0 keV microm(-1) for 103Pd, agreeing well with values reported in the literature. yD in a 1 microm sphere diminishes slightly with the distance from the seed for 103Pd. This is due to the spectral hardening caused by the presence of a gamma-ray of 357.5 keV in the initial spectrum of 103Pd. In parallel with the calculation of the microdosimetric spectra, we have analysed the distribution of the size of the energy deposition clusters generated by these low energy photons in structures of 2 and 10 nm of radius. Due to Compton interactions, the fraction of very low energy electrons (<5 keV) generated by 125I photons is 51%, whereas it is only 27% for 103Pd. As these electrons deposit their energy very locally, the pattern of energy depositions contains more clusters of a few nm of radius for 125I than for 103Pd; the mean cluster orders are respectively 3.3 and 3.0 for 10 nm clusters. This is in opposition with the prediction based on the microdosimetric spectrum and the parameter yD and could be of importance for the damage to the cells.

Algorithms↗

The radial dose function of low-energy brachytherapy seeds in different solid phantoms: comparison between calculations with the EGSnrc and MCNP4C Monte Carlo codes and measurements.

The use of low-energy photon emitters for brachytherapy applications, as in the treatment of the prostate or of eye tumours, has drastically increased in the last few years. New seed models for 103Pd and 125I have recently been introduced. The American Association of Physicists in Medicine recommends that measurements are made to obtain the dose rate constant, the radial dose function and the anisotropy function. These results must then be compared with Monte Carlo calculations to finally obtain the dosimetric parameters in liquid water. We have used the results obtained during the characterization of the new InterSource (furnished by IBt, Seneffe, Belgium) palladium and iodine sources to compare two Monte Carlo codes against experiment for these low energies. The measurements have been performed in three different media: two solid water plastics, WT1 and RW1, and polymethylmetacrylate. The Monte Carlo calculations were made using two different codes: MCNP4C and EGSnrc. These codes use photon cross-section data of a different origin. Differences were observed between both sets of input data below 100 keV, especially for the photoelectric effect. We obtained differences in the radial dose functions calculated with each code, which can be explained by the difference between the input data. New cross-section data were then tested for both codes. The agreement between the calculations using these new libraries is excellent. The differences are within the statistical uncertainties of the calculations. These results were compared with the experimental data. A good agreement is reached for both isotopes and in the three phantoms when the measured values are corrected for the presence of the TLDs in the phantom.

Algorithms↗

Dosimetry of clinical neutron and proton beams: an overview of recommendations.

Neutron therapy beams are obtained by accelerating protons or deuterons on Beryllium. These neutron therapy beams present comparable dosimetric characteristics as those for photon beams obtained with linear accelerators; for instance, the penetration of a p(65)+Be neutron beam is comparable with the penetration of an 8 MV photon beam. In order to be competitive with conventional photon beam therapy, the dosimetric characteristics of the neutron beam should therefore not deviate too much from the photon beam characteristics. This paper presents a brief summary of the neutron beams used in radiotherapy. The dosimetry of the clinical neutron beams is described. Finally, recent and future developments in the field of physics for neutron therapy is mentioned. In the last two decades, a considerable number of centres have established radiotherapy treatment facilities using proton beams with energies between 50 and 250 MeV. Clinical applications require a relatively uniform dose to be delivered to the volume to be treated, and for this purpose the proton beam has to be spread out, both laterally and in depth. The technique is called 'beam modulation' and creates a region of high dose uniformity referred to as the 'spread-out Bragg peak'. Meanwhile, reference dosimetry in these beams had to catch up with photon and electron beams for which a much longer tradition of dosimetry exists. Proton beam dosimetry can be performed using different types of dosemeters, such as calorimeters, Faraday cups, track detectors and ionisation chambers. National standard dosimetry laboratories will, however, not provide a standard for the dosimetry of proton beams. To achieve uniformity on an international level, the use of an ionisation chamber should be considered. This paper reviews and summarises the basic principles and recommendations for the absorbed dose determination in a proton beam, utilising ionisation chambers calibrated in terms of absorbed dose to water. These recommendations are based on the recent IAEA TRS398 Code of Practice: 'Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water'.

Humans↗

Dosimetric study of a new palladium seed.

In this paper, the dosimetric parameters for a new palladium seed design: the InterSource(103,)(1) are presented as recommended by the AAPM in the TG-43 formalism. Measurements are made with LiF thermoluminescent dosimeters (size of 1mm(3)) in solid water phantoms WT1 to obtain the dose constant, the radial dose function and the anisotropy function. The TLD were calibrated at 6 MV and an energy correction factor of 1.40 has been applied. The same dose parameters are also obtained by Monte Carlo calculations (MCNP4B) in solid water and in liquid water. The calculated and the measured TG-43 functions for solid water are in excellent agreement. In WT1, the calculated dose rate constant is 0.657+/-1% and the measured value is 0.672+/-7%. The calculated value for water is 0.692+/-1%. The comparison with the previous study (Med. Phys. 27(5) (2000)) shows a very good agreement for the dose rate constant. The agreement for the radial function is poorer. For the measurements, it can be due to the difference of TLD settings. For the calculations the discrepancy could come from the different cross-section data utilized in the different Monte Carlo codes. In conclusion, the dosimetric functions for the new iodine seed InterSource(103) have been determined using the MCNP4B Monte Carlo code and TLD measurement in solid water WT1.

Journal Article↗

[Benign diseases in radiotherapy: a practice survey in Belgium. Peer review of radiotherapy in Belgium].

In 1996 and 2000, a survey of radiation practice in Belgium was performed by sending a questionnaire to the different centers asking their opinion and number of patients treated. There was a great similarity between the two surveys both for indications and total number of patients irradiated. For the most common indications (prevention of cheloids, heterotopic bone formation, hyperthyroidy ophthalmopathy), there was a trend to use similar radiation technique following recent publications. In contrast, if the number of cases of macular degeneration is declining, the prevention of vessels restenosis is becoming more and more an indication.

Belgium↗

Experimental p(wall) and p(cel) correction factors for ionization chambers in low-energy clinical proton beams.

Current dosimetry protocols for clinical protons using ionization chambers do not take into account ionization chamber-dependent perturbation correction factors. In the present investigation, the relative response of 17 cylindrical ionization chambers was evaluated at three proton beam qualities: at two points in a modulated beam and one point in a non-modulated beam, all with an incident energy of 75 MeV. Thirteen of the ionization chambers had a Farmer-type geometry but consisted of different combinations of wall and central electrode materials. All ionization chambers were calibrated in terms of air kerma as well as in terms of absorbed dose to water in a 60Co beam. The relative response of the ionization chambers was compared with results of Monte Carlo simulations of proton and secondary electron transport in the phantom and the ionization chamber geometry. The results of the measurements for cylindrical ionization chambers show relative perturbation effects that are limited to 0.5-1%, resulting in perturbation correction factors that are larger than unity compared with an NE2571 ionization chamber. The experimental relative wall and total perturbation correction factors agree with Monte Carlo calculated values, indicating that the differences between the responses of different ionization chambers are due to secondary electron effects. This conclusion is supported by the comparison of our results with those from other investigators after re-analysis of their data. The central electrode perturbation correction factor for an aluminium electrode in a Farmer-type geometry was found to be unity within the experimental uncertainties.

Electrons↗

Dosimetry of beta-ray ophthalmic applicators: comparison of different measurement methods.

An international intercomparison of the dosimetry of three beta particle emitting ophthalmic applicators was performed, which involved measurements with radiochromic film, thermoluminescence dosimeters (TLDs), alanine pellets, plastic scintillators, extrapolation ionization chambers, a small fixed-volume ionization chambers, a diode detector and a diamond detector. The sources studied were planar applicators of 90Sr-90Y and 106Ru-106Rh, and a concave applicator of 106Ru-106Rh. Comparisons were made of absolute dosimetry determined at 1 mm from the source surface in water or water-equivalent plastic, and relative dosimetry along and perpendicular to the source axes. The results of the intercomparison indicate that the various methods yield consistent absolute dosimetry results at the level of 10%-14% (one standard deviation) depending on the source. For relative dosimetry along the source axis at depths of 5 mm or less, the agreement was 3%-9% (one standard deviation) depending on the source and the depth. Crucial to the proper interpretation of the measurement results is an accurate knowledge of the detector geometry, i.e., sensitive volume and amount of insensitive covering material. From the results of these measurements, functions which describe the relative dose rate along and perpendicular to the source axes are suggested.

Alanine↗

Calculation of beta-ray dose distributions from ophthalmic applicators and comparison with measurements in a model eye.

Dose distributions throughout the eye, from three types of beta-ray ophthalmic applicators, were calculated using the EGS4, ACCEPT 3.0, and other Monte Carlo codes. The applicators were those for which doses were measured in a recent international intercomparison [Med. Phys. 28, 1373 (2001)], planar applicators of 106Ru-106Rh and 90Sr-90Y and a concave 106Ru-106Rh applicator. The main purpose was to compare the results of the various codes with average experimental values. For the planar applicators, calculated and measured doses on the source axis agreed within the experimental errors (<10%) to a depth of 7 mm for 106Ru-106Rh and 5 mm for 90Sr-90Y. At greater distances the measured values are larger than those calculated. For the concave 106Ru-106Rh applicator, there was poor agreement among available calculations and only those calculated by ACCEPT 3.0 agreed with measured values. In the past, attempts have been made to derive such dose distributions simply, by integrating the appropriate point-source dose function over the source. Here, we investigated the accuracy of this procedure for encapsulated sources, by comparing such results with values calculated by Monte Carlo. An attempt was made to allow for the effects of the silver source window but no corrections were made for scattering from the source backing. In these circumstances, at 6 mm depth, the difference in the results of the two calculations was 14%-18% for a planar 106Ru-l06Rh applicator and up to 30% for the concave applicator. It becomes worse at greater depths. These errors are probably caused mainly by differences between the spectrum of beta particles transmitted by the silver window and those transmitted by a thickness of water having the same attenuation properties.

Beta Particles↗

Dosimetric study of the new Intersource125 iodine seed.

The use of low energy photon emitters for brachytherapy applications, as in the treatment of the prostate or of eye tumors, has significantly increased these last few years. New seed models for 125I have been recently introduced. The aim of this study is to determine the dosimetric parameters as recommended by the AAPM in the TG43 formalism for a new iodine seed design: the InterSource125 (Furnished by IBt, Seneffe, Belgium). Measurements are made with LiF thermoluminescent dosimeters (size of 1 mm3) in solid water phantoms to obtain the dose constant, the radial dose function, and the anisotropy function. The TLDs were calibrated at 6 MV and an energy correction factor of 1.41 has been applied. The same dose parameters are also obtained by Monte Carlo calculations (MCNP4B) in solid water and in liquid water. The radial function was measured at 1, 1.5, 2, 3, 4, 5, 6, and 7 cm and calculated between 0.3 and 7 cm. The anisotropy functions were measured at 2, 3, and 5 cm and calculated between 0.3 and 7 cm. The calculated and the measured TG43 functions for solid water are in excellent agreement. We have then calculated these functions in liquid water to obtain the dosimetric information for clinical applications as per TG43 recommendations. In WTI, the calculated dose rate constant is 0.98+/-1% and the measured value is 1.03 +/- 7 %. The calculated value for water is 1.02+/- 1 %. In conclusion, the dosimetric functions for the new iodine seed InterSource125 have been determined. They are quite different from the data of the well-known model 6711 from Amersham due to the absence of silver in the new seed. The characteristics are very similar to those of model 6702.

Anisotropy↗

Comparison of dosimetry recommendations for clinical proton beams.

The formalism and data in the two most recent dosimetry recommendations for clinical proton beams, ICRU Report 59 and the forthcoming IAEA Code of Practice, are compared. Chamber calibrations in terms of air kerma and absorbed dose to water are considered, including five different cylindrical ionization chamber types commonly used in proton beam dosimetry. The methodology for both types of calibration for ionization chambers is described in ICRU Report 59. The procedure based on air kerma calibrations is compared with an alternative formalism based on IAEA Codes of Practice (TRS-277, TRS-381), modified for proton beams. The new IAEA Code of Practice is exclusively based on calibrations in terms of absorbed dose to water and a direct comparison with ICRU Report 59 recommendations is made. Common to the two formalisms are the fundamental quantities Wair and w(air) and their atmospheric conditions of applicability. The difference in the recommended values of the ratio w(air)/Wair (protons to 60Co) is as large as 2.3%. The use of Wair and w(air) values for dry air (IAEA) and for ambient air (ICRU) is a contribution to the discrepancy, and the ICRU usage is questioned. For air kerma based chamber calibrations, ICRU Report 59 does not take into account the effect of different compositions of the build-up cap and chamber wall on the calibration beam quality. For the chamber types included in the study, this introduces discrepancies of up to 1.1%. Combined with differences in the recommended basic data, discrepancies in absorbed dose determination in proton beams of up to 2.1% are found. For the absorbed dose to water based formalism, differences in the formalism, notably the omission of perturbation factors for 60Co in ICRU 59, and data yield discrepancies in calculated kQ factors, and in absorbed dose determinations, between -1.5% and +2.6%, depending on the chamber type and the proton beam quality.

Air↗

The physical basis for radiotherapy with neutrons.

Radiotherapy with neutrons requires a large quantity of physical information about neutrons and their interaction with matter. Primarily the absorbed dose at a reference point needs to be determined. For treatment planning the dose distribution in a phantom must be measured and algorithms for the simulation of the dose distribution in a patient must be available. As neutrons interact with matter in a more complicated way as high-energy photons and electrons commonly used in radiotherapy, biological effects based on microdosimetric data are used for treatment planning. This paper presents a brief summary of the neutron sources used in radiotherapy. The dosimetry of the clinical neutron beams is described. Special aspects of the treatment planning with fast neutrons are discussed. For further radiobiological interpretation the fundamentals of microdosimetry are described. Finally recent and future developments in the field of physics for neutron therapy are mentioned.

Humans↗

Fast 2D phantom dosimetry for scanning proton beams.

A quality control system especially designed for dosimetry in scanning proton beams has been designed and tested. The system consists of a scintillating screen (Gd2O2S:Tb), mounted at the beam-exit side of a phantom, and observed by a low noise CCD camera with a long integration time. The purpose of the instrument is to make a fast and accurate two-dimensional image of the dose distribution at the screen position in the phantom. The linearity of the signal with the dose, the noise in the signal, the influence of the ionization density on the signal, and the influence of the field size on the signal have been investigated. The spatial resolution is 1.3 mm (1 s.d.), which is sufficiently smaller than typical penumbras in dose distributions. The measured yield depends linearly on the dose and agrees within 5% with the calculations. In the images a signal to noise ration (signal/1 s.d.) of 10(2) has been found, which is in the same order of magnitude as expected from the calculations. At locations in the dose distribution possessing a strong contribution of high ionization densities (i.e., in the Bragg peak), we found some quenching of the light output, which can be described well by existing models if the beam characteristics are known. For clinically used beam characteristics such as a Spread Out Bragg peak, there is at most 8% deviation from the NACP ionization chamber measurements. The conclusion is that this instrument is a useful tool for quick and reliable quality control of proton beams. The long integration-time capabilities of the system make it worthwhile to investigate its applicability in scanning proton beams and other dynamic treatment modalities.

Brachytherapy↗

RBE variation as a function of depth in the 200-MeV proton beam produced at the National Accelerator Centre in Faure (South Africa).

BACKGROUND AND PURPOSE: Thorough knowledge of the RBE of clinical proton beams is indispensable for exploiting their full ballistic advantage. Therefore, the RBE of the 200-MeV clinical proton beam produced at the National Accelerator Centre of Faure (South Africa) was measured at different critical points of the depth-dose distribution. MATERIAL AND METHODS: RBEs were determined at the initial plateau of the unmodulated and modulated beam (depth in Perspex = 43.5 mm), and at the beginning, middle and end of a 7-cm spread-out Bragg peak (SOBP) (depths in Perspex = 144.5, 165.5 and 191.5 mm, respectively). The biological system was the regeneration of intestinal crypts in mice after irradiation with a single fraction. RESULTS: Using 60Co gamma-rays as the reference, the RBE values (for a gamma-dose of 14.38 Gy corresponding to 10 regenerated crypts) were found equal to 1.16 +/- 0.04, 1.10 +/- 0.03, 1.18 +/- 0.04, 1.12 +/- 0.03 and 1.23 +/- 0.03, respectively. At all depths, RBEs were found to increase slightly (about 4%) with decreasing dose, in the investigated dose range (12-17 Gy). No significant RBE variation with depth was observed, although RBEs in the SOBP were found to average a higher value (1.18 +/- 0.06) than in the entrance plateau (1.13 +/- 0.04). CONCLUSION: An RBE value slightly larger than the current value of 1.10 should be adopted for clinical application with a 200-MeV proton beam.

Animals↗

RBE variation between fast neutron beams as a function of energy. Intercomparison involving 7 neutrontherapy facilities.

In fast neutron therapy, the relative biological effectiveness (RBE) of a given beam varies to a large extent with the neutron energy spectrum. This spectrum depends primarily on the energy of the incident particles and on the nuclear reaction used for neutron production. However, it also depends on other factors which are specific to the local facility, eg, target, collimation system, etc. Therefore direct radiobiological intercomparisons are justified. The present paper reports the results of an intercomparison performed at seven neutrontherapy centres: Orléans, France (p(34)+Be), Riyadh, Saudi Arabia (p(26)+Be), Ghent, Belgium (d(14.5)+Be), Faure, South Africa (p(66)+Be), Detroit, USA (d(48)+Be), Nice, France (p(65)+Be) and Louvain-la-Neuve, Belgium (p(65)+Be). The selected radiobiological system was intestinal crypt regeneration in mice after single fraction irradiation. The observed RBE values (ref cobalt-60 gamma-rays) were 1.79 +/- 0.10, 1.84 +/- 0.07, 2.24 +/- 0.11, 1.55 +/- 0.04, 1.51 +/- 0.03, 1.50 +/- 0.04 and 1.52 +/- 0.04, respectively. When machine availability permitted, additional factors were studied: two vs one fraction (Ghent, Louvain-la-Neuve), dose rate (Detroit), influence of depth in phantom (Faure, Detroit, Nice, Louvain-la-Neuve). In addition, at Orléans and Ghent, RBEs were also determined for LD50 at 6 days after selective abdominal irradiation and were found to be equal to the RBEs for crypt regeneration. The radiobiological intercomparisons were always combined with direct dosimetric intercomparisons and, when possible in some centres, with microdosimetric investigations.

Abdomen↗

The Nice high-energy neutron facility: dosimetry intercomparisons.

Neutron dosimetry intercomparison studies have been undertaken at the Nice neutrontherapy facility with the staff at Louvain-la-Neuve which has had wide experience in both dosimetric and radiobiological intercomparisons. Tissue equivalent (TE) ionization chambers were first calibrated in 60Co beams and then exposed in the neutron beam at different depths in a water phantom; the largest difference observed in neutron beam measurements with all the chambers tested was 0.89%, and most of them agreed to within less than 0.5%. The gamma component at four depths was derived from measurements with Geiger-Müller counters; the results obtained with the two counters (Nice and Louvain-la-Neuve), expressed as a percentage of the total dose (neutron + gamma), agreed to within less than 0.03% and the value increased from 1.4 to 4.2% between 2 and 20 cm in depth.

Calibration↗

The multileaf collimator for fast neutron therapy at Louvain-la-Neuve.

The multileaf collimator of the fast neutron therapy facility at Louvain-la-Neuve is described, as well as some of the physics experiments performed in order to evaluate the attenuation of neutron beams in different materials and thus optimize the composition of the collimator leaves. The multileaf collimator consists of two sets of 22 leaves each, which can be moved independently. They are made of iron and their thickness is 95 cm. Seven borated polyethylene disks are located in the distal part of the leaves in order to absorb more efficiently the low-energy component of the neutron spectrum. The width of the leaves is 1 cm at their distal part. The leaves can move 11 cm outwards and 6 cm inwards from their reference position, and field sizes up to 25.7 x 24.8 cm, as well as irregular field shapes, can be obtained. The inner part of the leaves and their two sides are always focused on the target. The complete multileaf collimator can rotate around the beam axis, from -90 degrees to +90 degrees from the reference position. The width of the penumbra (80-20% isodoses) is 0.64 cm and 1.17 cm at the depth of the maximum buildup and at 10 cm in depth respectively, for a 10 x 10 cm field size. The collimator is adequate for the energy of the p(65)+Be neutron beam of Louvain-la-Neuve and has been adapted to the fixed vertical beam. It has been designed following the original plans of Scanditronix, adjusted and fully assembled at the workshop of the Centre de Recherches du Cyclotron (CRC). Systematic measurements were performed in order to optimize the design and the composition of the leaves. In particular the attenuations of the actual beam and of monoenergetic neutron beams were measured in different materials such as iron and polyethylene. Above (upstream) the multileaf collimator, a fixed pre-collimator (iron thickness 50 cm; section 1 x 1 m) defines a conical aperture aligned on the largest opening of the leaves. It contains the two transmission chambers and a 2 cm thick polyethylene layer used for hardening the beam.

Belgium↗

[Water calorimetry measurements in a 85 MeV clinical proton beam].

The importance of water calorimetry in clinical proton beam dosimetry has increased for various reasons: there has been an increasing interest in proton therapy from the radiotherapy world; existing dosimetry protocols for clinical proton beams recommend calorimetry as the primary dosimetry method (ie, AAPM and ECHED); water has recently become the reference material for dose specification. For the water calorimetric dose evaluation, the water calorimeter developed in Ghent was used. Ionometry was performed following the ECHED protocol. The study resulted in a calorimetric to ionometric dose ratio of 0.974 +/- 0.009. The discrepancy should in our opinion be attributed to the (Wle)p,air value of 35.2 J/C implemented in the protocol, possibly next to ion chamber dependent effects for which indications are found in the ionometry measurements.

Calorimetry↗