Chemical shift artifact along the section-select axis.

Chemical shift artifact (CSA), familiar to radiologists along the frequency-encoding axis, also occurs along the section-select axis. The authors observed a case in which CSA mimicked a renal mass. Subsequent retrospective analysis of 50 abdominal magnetic resonance (MR) imaging studies was performed to assess occurrence of CSA adjacent to the upper and lower renal poles. CSA along the section-select axis was observed in 76% of cases and adjacent to 39% of all renal poles imaged. CSA along the section-select axis is common in abdominal MR imaging and may occasionally mimic disease.

Abdomen↗

MR imaging of hepatic iron overload in rat.

To investigate the relationship of hepatic signal intensity and T2 with histologic grading in an animal model of oral iron overload and to determine the duration of feeding necessary to produce abnormalities detectable on magnetic resonance (MR) images, hepatic iron overload was induced in 12 rats by feeding them a diet supplemented with 4% carbonyl iron for 2-11 weeks. Iron overload seen on MR images was graded independently and blindly by two radiologists as normal, mild, moderate, or severe. The rats were killed, and histologic findings were graded blindly by four pathologists using a similar subjective scale. Hepatic T2 values were estimated from spin-echo images. In the rats with iron overload, intracellular iron deposition was noted on histologic studies. On MR images, hepatic signal intensity and T2 decreased after only 2 weeks of dietary iron overload, and both continued to decrease with longer duration of feeding. There was significant correlation between iron overload duration and changes on MR images and between MR images and histologic grading (r = .92, P = .0001 for both). The mean T2 of hepatic iron overload decreased with longer duration of feeding.

Animals↗

Conventional and fast spin-echo MR imaging: minimizing echo time.

Magnetic resonance imaging is frequently complicated by the presence of motion and susceptibility gradients. Also, some biologic tissues have short T2s. These problems are particularly troublesome in fast spin-echo (FSE) imaging, in which T2 decay and motion between echoes result in image blurring and ghost artifacts. The authors reduced TE in conventional spin-echo (SE) imaging to 5 msec and echo spacing (E-space) in FSE imaging to 6 msec. All magnetic gradients (except readout) were kept at a maximum, with data sampling as fast as 125 kHz and only ramp waveforms used. Truncated sinc radio-frequency pulses and asymmetric echo sampling were also used in SE imaging. Short TE (5.8 msec) SE images of the upper abdomen were compared with conventional SE images (TE = 11 msec). Also, FSE images with short E-space were compared with conventional FSE images in multiple body sites. Short TE significantly improved the liver-spleen contrast-to-total noise ratio (C/N) (7.9 vs 4.1, n = 9, P < .01) on T1-weighted SE images, reduced the intensity of ghost artifacts (by 34%, P < .02), and increased the number of available imaging planes by 30%. It also improved delineation of cranial nerves and reduced susceptibility artifacts. On short E-space FSE images, spine, lung, upper abdomen, and musculoskeletal tissues appeared crisper and measured spleen-liver C/N increased significantly (6.9 vs 4.0, n = 12, P < .01). The delineation of tissues with short T2 (eg, cartilage) and motion artifact suppression were also improved. Short TE methods can improve image quality in both SE and FSE imaging and merit further clinical evaluation.

Abdomen↗

Hybrid RARE: implementations for abdominal MR imaging.

Hybrid RARE (rapid acquisition with relaxation enhancement) is a family of magnetic resonance (MR) imaging techniques whereby a set of images is phase encoded with more than one spin echo per excitation pulse. This increases the efficiency of obtaining T2-weighted images, allowing greater flexibility regarding acquisition time, resolution, signal-to-noise ratio, and tissue contrast. Hybrid RARE techniques involve several important new user-selectable parameters such as effective TE, echo train length, and echo spacing. Choices of other parameters, such as TR, sampling bandwidth, and acquisition matrix, may be different from those of comparable conventional T2-weighted spin-echo images. Different hybrid RARE implementations can be used for abdominal screening, with T2-weighted or T2-weighted and inversion-recovery contrast, or for characterizing liver lesions or imaging the biliary system with an extremely long TE. High-resolution images may be obtained by averaging multiple signals during quiet breathing, or images may be acquired more rapidly during suspended respiration. In this review, the authors discuss the basic principles of hybrid RARE techniques and how various imaging parameters can be manipulated to increase the quality and flexibility of abdominal T2-weighted MR imaging.

Abdomen↗

Pulsation artifact in short TR MR imaging and angiography: exacerbation with signal averaging.

Averaging the signals from more than one excitation per phase-encoding view increases the signal-to-noise ratio and, in conventional spin-echo magnetic resonance imaging, reduces most motion artifacts. To determine the effects of signal averaging on two-dimensional gradient-echo images, acquisitions with different TRs and with no averaging versus multiple-signal averaging were compared in a pulsatile flow phantom and the human abdominal aorta. Intraview (each view repeated before changing the phase-encoding value) and interview (obtaining all views sequentially and then repeating the entire set) averaging methods were used. Pulsation artifacts were present on all images of the flow phantom and the aorta. Intraview signal averaging, the method most commonly used, exacerbated rather than ameliorated pulsation artifacts with short TR sequences. Pulsation artifacts on two-dimensional images obtained with a short TR can be minimized by completing the acquisition as rapidly as possible, avoiding signal averaging. If signal averaging is used for short TR images, it should be interview averaging.

Algorithms↗

Fast spin-echo imaging of the temporomandibular joint.

The applicability of a fast spin-echo (FSE) technique for magnetic resonance imaging of the temporomandibular joint (TMJ) was studied, and the technique compared with a conventional spin-echo (CSE) technique. Sagittal T1-weighted CSE and dual-echo FSE images of 50 TMJs in 25 patients with symptoms of internal TMJ derangement were compared. CSE and FSE images were diagnostically comparable in 22 TMJs (44%). The FSE technique was rated better than CSE imaging for delineation of the disk in 26 joints (52%), whereas the CSE technique was rated better in only two joints (4%). The FSE technique was preferred overall in 54% of the joints. Mild to moderate joint effusion was detected in 17 joints because additional T2-weighted data were provided with the dual-echo FSE technique. The study showed that FSE imaging is an effective technique for evaluation of the TMJ. It is faster and diagnostically comparable to or better than CSE imaging, with the added advantage of providing T2-weighted data.

Adult↗

In vivo validation of tissue segmentation based on a 3D feature map using both a hamster brain tumor model and stereotactically guided biopsy of brain tumors in man.

The purpose of this study was to validate our MR tissue segmentation technique using a hamster brain tumor model and malignant brain tumors in man. We used a multispectral tissue segmentation analysis. Three sets of MRI data were included: proton density, T2-weighted fast spin echo, and T1-weighted spin echo, as inputs. Three image preprocessing steps included correcting image nonuniformity, application of an anisotropic diffusion type filter, and data point selection by a qualified observer. We used the k-Nearest Neighbor segmentation algorithm, which does not require prior knowledge of the sample distribution. This choice allowed us to optimize the different tissue clusters present in three-dimensional (3D) feature space. In vivo validation of the technique was performed in hamsters harboring tumors induced with JC virus-transformed HJC-15 cells, as compared to three control animals. Human brain tumors obtained by stereotactically guided biopsy in six patients were also included in the study. Finally, brain tumors were removed from two patients who underwent conventional craniotomy using segmentation-derived images as a guide. In the hamsters, 10 tissues were correctly identified by segmentation and were confirmed histologically (P < .02). In the patients, there was also a strong correlation between our segmentation results and the tissue obtained by stereotactic biopsy (P < .01). In one of the two patients who underwent open craniotomy, segmentation images were useful in revealing tumor spread into vital areas of the brain (motor area). In conclusion, the results of segmentation correlate well with the tissues in vivo and thus warrant further clinical utilization and evaluation.

Adult↗

Lactate observation in vivo by spectral editing in real time.

We have developed a novel in vivo proton MR spectroscopy magnetization transfer method for detection of lactate in ischemic tissue in the presence of interfering fat proton resonances. Pyruvate is magnetically labeled with a saturation pulse and, when converted to lactate, the lactate retains the label. Difference of spectra obtained with and without a saturation pulse contain no fat resonances. High-resolution spectra (determined with a GE 1.5 T Signa) of low lactate levels were obtained in vivo by water suppression using a 2662 composite RF pulse and slice-selective gradients. Spectral subtraction was performed in real time allowing the monitoring of a buildup of the intensity of the lactate peak. Pyruvate-lactate saturation transfer techniques should find wide applicability in the study of ischemia.

Humans↗

Multiple spin-echo MR imaging of the body: image contrast and motion-induced artifact.

For a given TR and TE, image quality changes when the number of spin echoes obtained is varied. To investigate the importance of this in clinical imaging, a total of 4 patients and 9 volunteers had MRI examinations of the abdomen (n = 7) and/or pelvis (n = 8) which included at least 2 sequences with identical TR (2000 or 2500 ms), TE (80 ms) and other parameters, but with a different series of refocusing pulses. Sequences included single-echo (S), asymmetric and symmetric double-echo (AD and SD) and quadruple-echo (Q) techniques. Image contrast and severity of motion-induced artifact was measured via blind examination by 3 independent MRI radiologists and calculation of signal-difference, signal-difference-to-noise ratios and intensity of motion-induced "ghost artifact." The order of decreasing signal differences was S, SD, AD and Q, and all of three liver lesions were better seen with S than with SD techniques. These observations are consistent with signal loss from cumulative inaccuracies from multiple 180 degrees RF pulses. The order of increasing intensity of ghost artifact was Q, SD, AD and S, consistent with the beneficial motion artifact-reducing effects of even-echo rephasing. Knowledge of these effects of multi-echo imaging allows one to make informed decisions about imaging protocols rather than to simply obtain multiple echoes "because they are free."

Abdomen↗

Improvement in signal-to-noise ratio and reduction of chemical shift and motion-induced artifacts by summation of gradient and spin echo data acquisition.

Narrow bandwidth magnetic resonance (MR) imaging allows an increase of signal-to-noise ratio (SNR) but causes increased chemical shift and motion-induced artifacts. To obtain MR images with SNR approximately equal to that obtained with narrow bandwidth but with less chemical shift and motion-induced artifact, we introduced triple readout gradient reversal centered around the spin echo. As a result, signals from two gradient echoes and a single spin echo can be collected and summed. Phantom, knee, shoulder, and abdominal MR images were obtained using a 1.5 T GE Signa System at sampling rates ranging from 10 to 60 kHz. Since the bandwidth per pixel was tripled, chemical shift misregistration was reduced by the same factor. The summation image of two gradient echoes and one spin echo had an SNR comparable with that of a single spin echo acquired within the same total sampling interval. Data acquisition at a high sampling ratio also minimizes the dispersion of T2* weighting among three echoes. In addition, summation of the three resulting images decreases motion artifact by effective averaging.

Abdomen↗

A simple method to improve image nonuniformity of brain MR images at the edges of a head coil.

One of the major sources of image nonuniformity in the high field MR scanners is the radiofrequency (RF) coil inhomogeneity. It degrades conspicuity of lesion(s) in the MR images of the brain and surrounding tissues and reduces accuracy of image postprocessing particularly at the edges of the coil. In this investigation, we have devised and tested a simple method to correct for nonuniformity of MR images of the brain at the edges of the RF head coil. Initially, a cylindrical oil phantom, which fit exactly in the head coil, was scanned on a 1.5 T imager. Then, a correction algorithm identified a reference pixel value in the phantom at the most homogeneous region of the RF coil. Next, every pixel inside the phantom was normalized relative to this reference value. The resulting set of coefficients or "correction matrices" was obtained for different types of MR contrast agent. Finally, brain MR images of normal subjects and multiple sclerosis patients were acquired and processed by the corresponding correction matrices obtained with different pulse sequences. Application of correction matrices to brain MR images showed a gain in pixel intensity particularly in the slices at the edge of the coil.

Algorithms↗

Clinico-topographic correlation of small vertebrobasilar infarct using magnetic resonance imaging.

Neurological, CT and high-field (1.5T) magnetic resonance imaging (MRI) data were correlated in 6 patients previously clinically diagnosed as having suffered small vertebrobasilar infarct. MRI demonstrated infarcts in areas where CT was nearly always negative. MRI allowed very precise clinico-topographic correlations and appears to be the preferred imaging technique in vertebrobasilar infarcts.

Aged↗

Magnetic resonance imaging of small medullary infarctions.

Small infarctions of the medulla produce typical neurologic deficits and can be clinically recognized fairly reliably. High-field magnetic resonance imaging with a 1.5 T prototype scanner successfully demonstrated very tiny medulla infarctions in three of five patients. These lesions were imaged readily by a fairly rapid (approximately 1-2 min scan time) partial-saturation technique and confirmed on multiple spin-echo images. In addition, in two cases vertebral occlusion ipsilateral to the infarction was suggested by high signal on T2 weighted spin-echo images.

Aged↗