Search PubMed⌕ Search

Biomedical subjects

S V Nguyen

Publications and source records attributed to S V Nguyen.

21 records · Page 2Linked to original sources

Rapid method for detection of Coxiella burnetii antibodies using high-density particle agglutination.

A high-density particle agglutination test, using erythrocyte-sensitizing substance from phase II Coxiella burnetii adsorbed to high-density composite particles, was developed for rapid serodiagnosis of Q fever. The test was compared with the microimmunofluorescence test for sensitivity and specificity by using 3,036 human serum samples collected in Gifu Prefecture, Japan. An excellent agreement was found between the two tests for the acute-phase group and paired serum samples, but some discordant results were observed in the single-sample group. The sensitivity and specificity of the high-density particle agglutination test were both 100% in the former group and 81.6 and 99.9%, respectively, in the latter group. The test is a very promising tool for routine serodiagnosis of Q fever because of its simplicity, sensitivity, and specificity.

Agglutination Tests↗

Q fever pneumonia in children in Japan.

The prevalence of Q fever pneumonia among children with atypical pneumonia from whom only an acute-phase serum sample was available was traced by using an indirect immunofluorescence (IF) test, nested PCR, and isolation. Twenty (34.5%) of 58 sera were found to have both polyvalent and immunoglobulin M antibodies to the phase II antigen of Coxiella burnetii by the IF test. Q fever pneumonia was present in 23 (39.7%) of 58 patients as determined by both the nested PCR and isolation and in 20 patients as determined by the IF test. The sensitivities for nested PCR and isolation were 100%, and that for the IF test was 87%. Our results indicate that nested PCR was faster and more sensitive than isolation and the IF test in the diagnosis of acute Q fever when a single acute-phase serum was available. These findings suggest that C. burnetii is an important cause of atypical pneumonia in children in Japan.

Antibodies, Bacterial↗

Standardization of methods for measuring plasminogen activator inhibitor activity in human plasma.

We have standardized the measurement of plasminogen activator inhibitor type 1 (PAI-1) activity in plasma. One-chain tissue-type plasminogen activator (t-PA; EC 3.4.21.31; final activity, 5 int. units/mL) was incubated with plasma (final dilutions 1:4 to 1:40) in phosphate buffer (pH 7.4, ionic strength = 0.15) for 15 min at 37 degrees C, followed by acidification and measurement of residual t-PA activity by an amidolytic method. The PAI-1 activity assay was 98% specific for PAI-1 activity in samples from both pregnancy and nonpregnancy, and varied linearly with added plasma volume when the percent inhibition of t-PA was between 8% and 50%. For the standardized method, analytical recovery was 93 +/- 5%, the detection limit was 1.6 arbitrary units per milliliter (1 arb. unit of PAI-1 activity = inhibition of 1 int. unit of t-PA activity), and total imprecision was 10.2 (SD 0.7) arb. units/mL (CV = 7%, n = 20). The average PAI-1 activity in 10 healthy individuals drawn between 0800 and 1000 hours was 23.9 +/- 15.4 arb. units/mL. Compared with the standardized assay, two of three previously described assays underestimated PAI-1 activity in plasma by 77% and 85%, respectively.

Blood Chemical Analysis↗