Search PubMed⌕ Search

Biomedical subjects

S Sundaram

Publications and source records attributed to S Sundaram.

77 records · Page 5Linked to original sources

Method for qualifying microbial removal performance of 0.1 micron rated filters. Part I: characterization of water isolates for potential use as standard challenge organisms to qualify 0.1 micron rated filters.

Although 0.1 microm rated filters intended for pharmaceutical sterilization applications have been commercially available for at least 15 years, there is no industry-wide standard for qualifying the microbial removal performance of these filters. In this article, we report on the bacterial challenge methodology used to screen four bacterial species for potential utility as a standard challenge organism to qualify 0.1 microm rated filters. These isolates were, in their natural state, demonstrated to penetrate 0.2/0.22 microm rated filters in prior studies. In the screening challenges described in this study, three out of these four candidates tested demonstrated consistent penetration of one 0.22 microm rated filter type tested (when cultured in a low nutrient medium under standard laboratory conditions). These included 6204-22 (FAME ID Acidovorax avenae citrulli), 6266-15 (FAME ID Comamonas acidovorans), and 6266-34 (FAME ID Hydrogenophaga pseudoflava). Of these, H. pseudoflava (6266-34) was chosen for additional experiments with other 0.2 microm rated filter membranes. In total, seventeen 0.2 and 0.22 microm rated filter discs, spanning five different "sterilizing grade" filter types from three different filter manufacturers were tested. H. pseudoflava penetration was observed for every filter tested. Under the same challenge conditions, H. pseudoflava was consistently retained by a 0.1 microm rated hydrophilic PVDF (polyvinylidenefluoride) filter with a specified high titer reduction claim for Acholeplasma laidlawii. In order to ensure selection of the most stable penetrative phenotype (i.e., select for nonrevertants), H. pseudoflava was subjected to three rounds of "filter cloning," and these results are described herein. The advantages of using H. pseudoflava for qualifying the microbial removal performance of 0.1 microm rated filters are also discussed.

Acholeplasma↗

Method for qualifying microbial removal performance of 0.1 micron rated filters. Part II: preliminary characterization of Hydrogenophaga (formerly Pseudomonas) pseudoflava for use as a standard challenge organism to qualify 0.1 micron rated filters.

In this article, we report on the preliminary characterization of Hydrogenophaga (formerly Pseudomonas) pseudoflava for potential use as a standard challenge organism to qualify 0.1 microm rated filters. Filter-cloned H. pseudoflava (ATCC 700892) was easily cultured in a low nutrient broth (R2A broth) under standard laboratory conditions, reaching high titers of 10(8)-10(9) cfu/mL within 48-65 hours of incubation at 25+/-5 degrees C. Under these conditions, H. pseudoflava is a rod-shaped bacterium, averaging 0.25+/-0.03 microm by 1.65+/-0.35 microm, and appears to be smaller than Brevundimonas diminuta in width (0.31+/-0.03 microm), but somewhat longer in length (0.88+/-0.19 microm), which may partly explain the observed penetration. In total, thirty-five 0.2/0.22 microm rated filter discs, spanning five different "sterilizing grade" filter types from two different filter manufacturers were challenged with H. pseudoflava. In all cases, H. pseudoflava was shown to consistently penetrate every 0.2/0.22 microm rated filter disc tested. These tests also spanned three different challenge durations, including short-term challenges (30-40 minutes), and two different challenge fluids. The use of serial (double) 0.22 mm rated filters, which is a common industry practice to reduce the prefiltration bioburden to the final "sterilizing" filter, was also shown to be inadequate to fully retain H. pseudoflava under the challenge condition used. In contrast, two different 0.1 microm rated filter types functionally qualified with a specified high titer reduction claim for Acholeplasma laidlawii, were shown to consistently and fully retain H. pseudoflava, and retention by these two filter types was shown to be robust and independent of the challenge duration.

Acholeplasma↗

Method for qualifying microbial removal performance of 0.1 micron rated filters. Part III: bacterial challenge tests on 0.2/0.22 and 0.1 micron rated filter cartridges with Hydrogenophaga (formerly Pseudomonas) pseudoflava.

We have previously reported on the preliminary characterization of Hydrogenophaga (formerly Pseudomonas) pseudoflava for potential use as a standard challenge organism to qualify 0.1 microm rated filters. This article reports on the retention efficiencies of a large panel of 0.2/0.22 microm and 0.1 microm rated filter cartridges for H. pseudoflava (ATCC 700892) versus the retention capabilities of the same filters for Brevundimonas diminuta (ATCC 19146). A total of thirty-two 0.2/0.22 microm rated filter cartridges, spanning nine different "sterilizing grade" filter types from four different filter manufacturers, were challenged with H. pseudoflava at challenge levels exceeding 10(7) cfu/cm2. H. pseudoflava was shown to penetrate every 0.2/0.22 microm rated filter tested, with log titer reduction (LTR) values ranging from 3.5 to 7.7 logs. H. pseudoflava was shown to be more penetrative than B. diminuta under the same challenge conditions. B. diminuta was fully retained by nineteen of the twenty 0.2/0.22 microm rated filters that were challenged with both organisms. In the case of 0.1 microm rated filters, eighteen filter cartridges, spanning five different filter types from three manufacturers were tested. H. pseudoflava was consistently retained by four out of the five filter types tested, with LTR values in excess of 11.5 to 12.2 logs. The 0.1 microm rated filter type that was penetrated by H. pseudoflava has been previously demonstrated to be not fully retentive for naturally occurring bacteria. The data show that H. pseudoflava penetrates 0.2/0.22 microm rated filters just as readily as B. diminuta penetrates 0.45 microm rated filters. In addition, titer reductions provided by 0.2/0.22 microm rated filters for H. pseudoflava are comparable to those reported for A. laidlawii mycoplasma, albeit under different conditions. This study demonstrates that H. pseudoflava meets all criteria for use as a standard organism for qualifying the microbial removal performance of 0.1 microm rated filters for enhanced sterility assurance.

Acholeplasma↗

Monitoring of factor XII activity and granulocyte elastase release during cardiopulmonary bypass.

Monitoring of the influence of cardiopulmonary bypass (CPB) on hematologic parameters is relevant to an improved understanding of the pathophysiology produced, as well as for the development of improved methods. The selection of suitable parameters is highly important. In this study, both contact phase activation and leukocyte response have been studied. Contact activation was determined by a novel assay for the measurement of Factor XII activity (FXIIA), and leukocyte response was measured by the release of granulocyte elastase. Five patients undergoing elective coronary artery surgery using a bubble oxygenator and pulsatile perfusion were studied. A notable feature of this study was the gradual increase of FXIIA during the study period, with granulocyte elastase levels following a similar pattern. Both FXIIA and granulocyte elastase are appropriate parameters for monitoring CPB, and could be useful in studying alternative bypass procedures and antithrombotic agents.

Aged↗