The effect of injection of powdered biomaterials on mouse peritoneal cell populations.

The authors suggest an experimental model for the assaying, before implantation, of the tissue reaction that wear particles from artificial joints can cause in the human body. Mice were intraperitoneally injected with biomaterial powders in suspension in saline. The materials used were chromium, chromium oxide, nickel, nickel oxide, aluminum, alumina, alumina-titania, cobalt, molybdenum, titanium, silver, zirconium oxide, iron oxide, and stainless steel. Peritoneal lavage was performed a week after injection. A thorough morphological and quantitative analysis of the cell suspension thus obtained was made both immediately after collection and after a 24 h culture.

Animals↗

Biocompatibility testing of prosthetic implant materials by cell cultures.

The main aspects of biocompatibility are discussed first then the methodology used and the results obtained. The cells used included epithelial cells, lymphocytes, fibroblasts, and macrophages. The most commonly used methods were morphological observation, radioactive tracer uptake, and chemotactic migration analysis. It is concluded that cell cultures are a reliable and sensitive method for initial screening in testing the biocompatibility of the materials used in the construction of prosthetic implants.

Animals↗

The effect of surface material and roughness on bone screw stability.

OBJECTIVE: To evaluate the effects of osteointegration ability and surface texture on bone screw interface stability in three different groups of titanium screws. DESIGN: Sixty titanium tapered screws were used: twenty screws were polished, uncoated (Group A); twenty screws were rough, coated with titanium (Group B); and twenty screws were rough, coated with fluor-hydroxyapatite (Group C). Thirty screws, ten per group, were implanted in the femurs and tibiae of two sheep, which were euthanized one month after surgery. The remaining thirty screws, ten per group, were implanted in the femurs and tibiae of another two sheep, which were euthanized three months after surgery. RESULTS: At one month, extraction torque of Group C was higher than that of Group A (p = 0.042). At three months, extraction torque of Group C was higher than that of Group A (p < 0.0001) and Group B (p < 0.0001). At three months, extraction torque of Group C was higher compared with the corresponding insertion torque (p < 0.0001) and compared with the corresponding extraction torque at one month (p < 0.0001). At one and three months, a high percentage of bone-screw contact was observed histologically in Groups B and C. A continuous gap with fibrous tissue encapsulation was observed in Group A. CONCLUSIONS: This study shows that the osteointegration ability provided by the type of coating is a very important parameter for optimizing the bone-screw stability. Surface texture is also important. By using screws with optimal osteointegration ability, very positive clinical consequences can be expected.

Animals↗

Quantitative evaluation by image analysis of platelet morphological modifications after contact with polyvinylacetate.

BACKGROUND: In order to investigate platelet activation after contact with artificial materials, which is an important aspect of biocompatibility especially for the blood-contacting devices, platelet morphological modifications and spread area were evaluated by light microscopy and image analysis after contact with glow discharge-treated polybutylene terephthalate coated with a polymer for platelet concentrate filtration. METHODS: A hydrophilic polymer made of partially hydrolyzed polyvinyl-acetate containing polyethylene oxide/poly-propylene oxide copolymer block as lateral chains (PVA) (Biofil S.r.l., Cavezzo, Modena, Italy) was evaluated. After contact with PVA, platelets were allowed to settle on a siliconized slide and then fixed and stained. The specimens were analyzed by image analysis. The percentages of spreading, round and dendritic shapes, as well as the presence of aggregates, were evaluated, and the mean area of the spread platelets was measured. RESULTS: PVA induced significant variations neither in the percentages of shape change distribution, nor of the mean spread area. However it determined a statistically significant reduction in platelets with the area from 60 to 70 mu 2. Such minimal variations agree with the results we obtained in the past, namely a non significant platelet adhesion induced by the same material. CONCLUSIONS: The method confirms the results of platelet adhesion and release reaction (the study of release reaction needs more refined but more expensive methods). However, the study of morphological modifications by image analysis is not suitable for testing materials that induce massive platelet adhesion, because the number of the residual platelets could be too low for the microscopic evaluation.

Analysis of Variance↗

Cellular reactions in hip prosthesis loosening.

Based on the results obtained in histological examinations carried out on periprosthetic tissues in a large series of cases of prosthetic hip joint explants, the authors analyze the cellular events that may occur in loosening phenomena as compared to what occurs in the paraphysiological repair process that is observed in the stable prosthesis. Like other authors, they believe that the principal role in the mechanism of loosening is played by macrophages which are recalled in a large number, at times together with multinucleate giant cells, at the bone-implant interface, after micromovements of the prosthesis and the formation of wear particles have occurred. The macrophages would be capable of favoring resorption of the periprosthetic bone tissue, producing areas of osteolysis in which the transmission of the mechanical stress of loading is modified. The ensuing prosthetic instability increases wear phenomena, causes a greater amount of osteolysis, and, in a vicious cycle, loss of the relationship between bone and implant, and, thus, prosthetic loosening. Finally, the authors report a hypothesis on the pathogenesis of the phenomenon, based on which non-physiological stress, associated with wear and eventually infection, leads to loosening.

Bone Cements↗

Considerations on ceramic prosthesis explants.

The authors report data obtained for 11 cases of explants of prostheses having ceramic joint surfaces. The wear phenomena observed in 9 prostheses, including 1 case with breakage of the ceramic head, was moderate: 20-22,000 debris per mu 2. In 2 cases the wear was massive, with a concentration of debris in the peri-implant tissues 5-10 times greater (100,000-218,000 debris per mu 2). An explanation for the trigger mechanism of wear phenomena is proposed: the cases of massive wear are related to loosening of the acetabulum. A histological examination of the bone tissue surrounding a stem covered with alumina (Al2O3) carried out in three cases allowed us to observe an area of demineralization measuring approximately 500 mu of tissue in contact with the ceramic coating. The osteomalacia could be caused by the diffusion of alumina ions.

Bone Cements↗

Osteorticular amyloidosis in a patient under dialysis treated by total hip arthroplasty: case report and review of the literature.

The authors present the case of a patient affected by kidney failure, who had been undergoing dialysis for several years when areas of osteolysis and bone resorption in the proximal femur and pathologic fracture appeared. She was treated surgically by hybrid total hip arthroplasty. The patient also complained of pains in other joints. The bone tissue taken from the osteolytic area was examined histologically. The test showed the presence of an amyloid substance. Microradiography and X-ray diffractometry carried out on the same samples confirmed the lack of mineralisation due to the presence of aluminum ions, presumably derived from dialysis. The high concentration of this element was confirmed by resum assay with spectrophometry in atomic absorption. Considering the results of the aforementioned tests, the patient was put on dialysis using a polymethylmethacrylate filter.

Amyloidosis↗

An evaluation of the "in vivo" and "in vitro" biological reaction and mechanical features of carbon fibre composites.

Tissue reaction to an epoxy resin-carbon fibre composite was tested "in vivo" and "in vitro" in order to evaluate this material as an alternative to metal alloys for clinical use in orthopaedic surgery. While the "in vitro" tests suggest a mild toxic effect of the composite on cells, good biocompatibility "in vivo" was observed when debris are not generated. The mechanical tests compared the composite and stainless steel plates, confirming the expected values for static strength and elastic modulus, revealing, however, the formation of long needles of carbon fibre following breakage of the plate.

Animals↗

The use of ceramic in prosthetic hip surgery. The state of the art.

The authors review current knowledge regarding the use of ceramic materials in prosthetic hip surgery, both as constituents of prosthetic components, and as materials used to coat metallic surfaces. A review of the literature defines the advantages and disadvantages to using ceramic-polyethylene or ceramic-ceramic combinations, based on the possibility that alumina coating may favor localized bone demineralization, and on the first promising clinical results of the use of hydroxyapatite coating.

Aluminum↗

Histomorphometric evaluation and pathogenesis of prosthetic loosening.

On the basis of a vast experience deriving from the histological study of explants of hip joint prostheses, the authors emphasize the role of histomorphometric testing in allowing for a quantitative evaluation of periprosthetic cellular reaction, of the bone structure, and of the wear phenomena of the implant, in order to gain a better understanding of the pathogenetic mechanisms responsible for the phenomenon of loosening. In agreement with what has been reported by other authors, they describe what they were able to observe by image analysis, microradiography, x-ray diffraction, and microdurimetry in various types of explanted prostheses. In particular, they describe data on the features of the wear particles, the periprosthetic cellular component, the thickness of the interfacial membrane and of the joint neocapsule, the volume of bone-ingrowth, the contact surface, and the structure of the bone-implant interface. Based on the changes observed using histomorphometry, a pathogenetic hypothesis was formulated according to which physical phenomena closely related to the type of implant used, such as wear and metal ion release, and non-physiological stress exerted on the bone, cause a series of cellular chain reactions. Within this context, macrophages, lymphocytes, osteoblasts and osteoclasts are in a continuous state of activation and, both directly and by means of the production of cytokines and other substances, they are responsible for bone resorption and thus loss of continuity between the bone and the implant, resulting in prosthetic loosening.

Hip Prosthesis↗

[Assessment of various immunologic parameters in silicone implant carriers].

The Authors evaluated some immunological parameters in women carrying silicone gel-filled breast implants for over one year. Peripheral blood samples from 22 patients were examined in order to assess both the antigenic pattern of lymphocyte subpopulations by cytofluorimetric analysis, and the cell proliferation of PHA-stimulated lymphocytes by the uptake of tritiated thymidine. These tests were performed at the time of the sample withdrawal and after in vitro reexposure to silicone extract for 48-72h. Changes in lymphocyte subpopulations and functional response were observed when patients were divided into groups according to the type of surgery, i.e. breast augmentation or reconstruction, or to the degree of periprosthetic capsular contracture. These results suggest the possibility of an interaction between silicone and the immune system, which cannot be disregarded for the explanation of the silicone related complications.

Adult↗