Search PubMed⌕ Search

Biomedical subjects

S Saini

Publications and source records attributed to S Saini.

At least 289 records · Page 16Linked to original sources

MR imaging of pelvic lymph nodes in primary pelvic carcinoma with ultrasmall superparamagnetic iron oxide (Combidex): preliminary observations.

The potential of ultrasmall superparamagnetic iron oxide (Combidex)-enhanced MRI of pelvic lymph nodes in patients with primary pelvic carcinoma is evaluated. Fifteen histologically classified lymph nodes in six patients with known primary pelvic cancer (four prostate; one rectum; one uterus) were evaluated with T2-weighted fast spin-echo (FSE) and T2*-weighted gradient-echo (GRE) MRI at 1.5T 12 to 48 hours after intravenous administration of Combidex at a dose of 1.7 mg Fe/kg. Quantitative image evaluation was performed by comparing signal intensity of individual nodes on pre- and postcontrast images. All patients proceeded to pelvic lymph-node biopsy or surgical dissection, where six were found to be benign and nine were malignant. Of the 15 lymph nodes, four nodes showed a decrease in signal intensity. Of these, three, in which signal loss was homogenous were benign, and one, in which the signal-intensity decrease was heterogeneous, was malignant (micrometastases). No signal change was noted in 11 of 15 lymph nodes of which three were benign (inflammatory) and eight were malignant. Combidex is a promising MR contrast agent for evaluating pelvic lymph nodes. Our preliminary observations suggest that the agent is most useful for classifying normal lymph nodes.

Adult↗

A multicenter clinical trial of Gadolite Oral Suspension as a contrast agent for MRI.

The purpose of this study was to assess the effectiveness and safety of Gadolite Oral Suspension as a gastrointestinal (GI) contrast agent for MRI in a phase II and two phase III multicenter clinical trials. Gadolite was administered to 306 patients with known or suspected abdominal and/or pelvic disease. MRI with T1- and T2-weighted sequences was performed before and after ingestion. Efficacy was evaluated by having two masked readers rate the certainty of their MR diagnosis (0 = uncertain, 1 = probable, 2 = definite) on randomly presented pre- and post-Gadolite Oral Suspension enhanced images. Principal investigators also evaluated the images and established the final diagnosis. Vital signs, clinical chemistries, and adverse events were documented. Blood and urine samples were analyzed for gadolinium content to determine whether Gadolite Oral Suspension was absorbed systemically. Certainty in MR diagnosis increased significantly (P < .001) for both blinded readers between pre- and post-Gadolite images (.49-1.18 for reader 1: .46-1.53 for reader 2). Sensitivity, specificity, and accuracy also increased for both masked readers. No gadolinium was detected in blood or urine samples. There were no serious adverse events and no apparent drug-related trends in mean vital signs or laboratory values. Gadolite is a highly effective, safe, and well tolerated contrast agent for clinical use with MRI.

Administration, Oral↗

Thorotrast-induced cholangiocarcinoma: case report.

Thorotrast, a contrast medium used extensively before being banned in 1950s, delivers a densely ionizing, high linear energy transfer type of radiation that predisposes to malignancies. We report a case of peripheral cholangiocarcinoma and describe its computed tomographic and magnetic resonance imaging features in a patient who developed it 48 years after exposure to Thorotrast.

Aged↗

Intraductal papillary mucinous tumors of the pancreas.

Intraductal papillary mucinous tumor (IPMT) is an uncommon pancreatic neoplasm with characteristic histology and distinctive clinicobiologic behavior. It is characterized by proliferation of ductal epithelium associated with ductal dilatation and variable mucin production. Due to indolent nature of these tumors, IPMTs are frequently missed or misdiagnosed. Prompt recognition and differentiation from other tumors are essential because IPMT has a better prognosis than other pancreatic malignancies. The purpose of this article is to display the radiologic spectrum of IPMT.

Aged↗

Dynamic T1-weighted ferumoxides enhanced MRI for imaging liver hemangiomas: preliminary observations.

The T1-based signal-enhancing effects of ferumoxides was studied in five liver hemangiomas on short echo-time gradient-recalled echo dynamic magnetic resonance imaging to assess the utility of this technique to image perfusion patterns in liver hemangiomas. We observed peripheral nodular enhancement with centripetal fill in all hemangiomas. Our results suggest that this imaging technique, after rapid injection of ferumoxides, can be used for lesion characterization.

Aged↗

Comparison of in-phase and out-of-phase gradient recalled echo T1-weighted pulse sequence for MR imaging of malignant liver masses following administration of paramagnetic gadolinium-chelate.

BACKGROUND: The purpose of this study was to compare the performance of in-phase and out-of-phase gradient recalled echo (GRE) pulse sequences on paramagnetic contrast-enhanced magnetic resonance (MR) imaging of malignant liver lesions. METHODS: Fifty patients (27 women, 23 men; mean age = 50 +/- 27 years) with known or suspected focal liver lesions, nine of whom had a fatty liver, were examined at 1.5 T before and 60 min after injection of gadobenate dimeglumine at a dose of 0.05 or 0.1 mmol/kg using two GRE techniques: echo time of 2.3 ms (out-of-phase) or 4.6 ms (in-phase). Liver signal-to-noise ratio (SNR) and lesion-liver contrast-to-noise ratio (CNR) were calculated. RESULTS: In patients with a nonfatty liver, liver SNR increased from 26 +/- 9 to 41 +/- 17 on in-phase images and from 28 +/- 8 to 45 +/- 14 on out-of-phase images. In patients with a fatty liver, in-phase images provided significantly higher (p < 0.01) liver SNR than did out-of-phase images predose (34 +/- 8 on in-phase vs. 21 +/- 8 on out-of-phase) and postdose (44 +/- 13 on in-phase vs. 33 +/- 14 on out-of-phase). In patients with a nonfatty liver, lesion-liver CNR was similar on in-phase and out-of-phase images, predose and postdose. In patients with fatty liver, lesion-liver CNR was significantly (p < 0.01) lower on out-of-phase images on predose and postdose images. CONCLUSION: In-phase GRE imaging is recommended for imaging focal liver lesions on paramagnetic contrast-enhanced MR imaging in patients with fatty infiltration of the liver.

Adult↗

Perfusion characteristics of hepatic cavernous hemangioma using intravenous CT angiography (IVCTA).

Thirty-three patients with 35 proven hepatic cavernous hemangiomas (HCH) were studied with intravenous CT angiography (IVCTA). 15 scans were performed during the first 30 s after bolus (6 ml/s) injection of 50 ml iodinated contrast material. Thereafter 2 scans/min were obtained up to 30 min. Three criteria were utilized at IVCTA to make a specific diagnosis of HCH: (1) detection of an intense mural nodular enhancement in the arterial phase. The density in the nodular region(s) should have a density level similar to that of the aorta or hepatic arteries; (2) well-defined nodular area(s); and (3) centripetally oriented enlargement of the nodular region(s). These criteria were seen in 31 of 35 hemangiomas. In contrast the 'typical' Freeny-Marks criteria were present in only 23 of 35 hemangiomas. The results show that our criteria may provide greater specificity.

Adult↗

MRI of hepatic lymphoma.

Thirteen patients with biopsy proven hepatic lymphoma (2 Hodgkin, 11 Non-Hodgkin) and a control group of 15 patients with hepatic metastases were analyzed quantitatively and qualitatively by MRI. Focal hepatic lymphoma was most reliably detected (eight of eight patients) and appeared hypointense relative to liver on T1 weighted (CNR - 7.4 +/- 2.3) and hyperintense on T2 weighted (CNR + 8.4 +/- 2.9) images. The mean T1 and T2 relaxation times of focal hepatic lymphoma (T1 = 832 +/- 234 msec, T2 = 84 +/- 16 ms) differed significantly from adjacent non-tumorous liver (T1 = 420 +/- 121 ms, T2 = 51 +/- 9 ms; p less than 0.05), however CNR values and relaxation times were similar to those of hepatic metastases. Diffuse hepatic lymphoma (microscopic periportal infiltration) was undetectable by MRI in three patients by either morphologic features or quantitative criteria. A mixed pattern of hepatic lymphoma (focal lesions and diffuse infiltration) showed focal areas of slightly decreased signal intensity on T1 weighted images (CNR = -1.7 +/- 0.4) while T2 weighted images revealed multiple regions of focal hyperintensity (CNR = +13.3 +/- 8.4) superimposed on a diffusely hyperintense liver. Our experience demonstrates that either T1 or T2 weighted techniques are useful in detecting focal and that T2 weighted techniques are useful in detecting mixed hepatic lymphoma. Conventional image derived relaxation time measurements and quantitative parameters were of no additional diagnostic value.

Adenocarcinoma↗

Hepatic metastases: rat models for imaging research.

Improved rat liver tumor models with solitary or multiple metastatic tumors were developed for radiological imaging research. Unlike previous studies which employed trocar inoculation of tumor fragments, an enzymatically disaggregated cell suspension of mammary cancer was injected by fine needle either directly into the liver to produce solitary cancer nodules, or indirectly via the spleen or mesenteric vein to produce multiple liver metastases. Tumor size was proportional to the time elapsed after implantation. The operative mortality of direct liver, splenic parenchymal, and mesenteric inoculations were 8%, 4%, and 27%, respectively. MR tissue characteristics, image contrast, and pharmaceutical enhancement of these tumors closely resembles human hepatic metastases. The availability of reproducible, inexpensive animal models of metastatic cancer allows efficient evaluation of new liver imaging techniques.

Adenocarcinoma↗

Iron-EHPG as an hepatobiliary MR contrast agent: initial imaging and biodistribution studies.

The paramagnetic metal complex iron(III) ethylenebis-(2-hydroxyphenylglycine) [Fe(EHPG)-] is an effective hepatobiliary contrast agent for liver enhancement in magnetic resonance (MR) imaging. The intravenous administration of 0.2 mmol/kg of Fe(EHPG)- to rats yields a 200% increase in the signal intensity of the liver when using a T1-weighted inversion recovery pulse sequence on a 1.4 T imaging system. Biodistribution studies in rats and a rabbit, along with imaging studies in a dog at 0.6 T, confirm that the complex has significant hepatocellular uptake and appears to be excreted unaltered into the bile. Control experiments with a different iron complex, iron(III) diethylenetriaminepentaacetic acid, reveal little hepatic affinity and poor enhancement capability due to its extracellular distribution. This initial evaluation of Fe(EHPG)- demonstrates that paramagnetic metal complexes with hepatobiliary specificity are well suited for enhancement of normal liver parenchyma and may increase the sensitivity of MR in the detection of liver disease.

Animals↗

Clinical application of abdominal echoplanar imaging (EPI): optimization using a retrofitted EPI system.

OBJECTIVE: Echoplanar MRI (EPI) with data acquisition times as short as 36 ms has been advocated for imaging body areas where gross physiologic motion degrades images. In this study we investigated the effect of various operator-defined parameters on image quality in EPI of the abdomen using a commercially available scanner. MATERIALS AND METHODS: Specifically, we assessed the effect of breathholding, slice thickness, k-space coverage (raw data size), and high resolution EPI in volunteers. The effect of these parameters on signal-to-noise ratio (SNR) and image quality of liver, spleen, kidney, and pancreas was evaluated to propose guidelines for clinical EPI of the abdomen. The requirements for contiguous imaging were analyzed in a phantom experiment. RESULTS: Our study suggests that optimum clinical EPI requires a minimum slice thickness of 7 mm. Breathhold single shot techniques are preferred to avoid spatial misregistrations and to optimize the signal yield for segmented techniques. Maximum k-space coverage at a given TE should be implemented. High resolution techniques (128 x 512) suffer from low SNR and are clinically not useful for routine EPI. Contiguous imaging requires a scan time of > 6 s to eliminate effects of cross-talk. CONCLUSION: The results suggest that clinical EPI requires careful attention to the choice of imaging parameters. The practical recommendations may help other investigators to optimize their clinical EPI studies.

Abdomen↗

Staging of colon carcinoma using water enema CT.

OBJECTIVE: To determine the accuracy of water enema CT (WECT) for staging colon carcinoma. MATERIALS AND METHODS: Thirty patients with colon cancer, diagnosed by barium enema and/or colonoscopy, underwent preoperative WECT. Dynamic contrast enhanced CT studies were performed after rectal administration of < or = 2 L lukewarm tap water. Images were prospectively analyzed for depth of tumor invasion, nodal involvement, and distant metastases by investigators blinded to the results of barium enema and colonoscopy. Surgical/pathologic proof was obtained in all cases. RESULTS: Using WECT, 23 of 30 patients were correctly staged. Correct staging occurred in 2 of 2 patients with Stage A, 3 of 3 patients with Stage B1, 6 of 9 patients with Stage B2, 1 of 2 patients with Stage C1, 5 of 8 patients with Stage C2, and 6 of 6 patients with Stage D tumors. Of the patients incorrectly staged, 4 were understaged and 3 were overstaged; all were due to errors in predicting lymph node involvement. Sensitivity and specificity for evaluating nodal involvement were 60 and 79%, respectively. CONCLUSIONS: Water enema CT allows for accurate depiction and staging of colon carcinoma. Aqueous distention of the colon avoids artifacts seen with positive contrast agents yet allows accurate evaluation of the bowel wall and pericolonic structures.

Aged↗

Splenic imaging with ultrasmall superparamagnetic iron oxide ferumoxtran-10 (AMI-7227): preliminary observations.

PURPOSE: Ferumoxtran-10 (ultrasmall superparamagnetic iron oxide; Combidex, AMI-7227) is a long-circulating MR contrast agent with reticuloendothelial uptake known to enhance tissue T1 and T2 relaxation rates. The purpose of this study was to assess the effect of ferumoxtran-10-enhanced MRI in evaluating focal splenic lesions. METHOD: Eighteen patients underwent MR evaluation of the spleen. Two of these patients with exophytic normal splenic tissue (splenules) and 13 of these patients with 24 focal splenic lesions (7 cysts, 2 hemangiomas, 7 metastases, 1 infarct, 7 lymphoma) were assessed by T1-weighted gradient echo and T2-weighted fast SE MRI following intravenous administration of ferumoxtran-10 (1.1 mg of Fe/kg). Qualitative analysis involving improved lesion detection and/or characterization, additional information from postcontrast images affecting staging, and patient management was performed. Quantitative measurements of lesion-to-spleen contrast-to-noise ratio were also performed. RESULTS: Additional information was provided by ferumoxtran-10-enhanced images in 15 of 18 patients. In 8 of 15 (53%) patients, improved lesion detection (i.e., number of lesions) was obtained on contrast-enhanced images. Improved lesion visualization (i.e., conspicuity) was noted in 11 of 15 (73%) of patients. In 10 of 15 (67%) patients, postcontrast imaging provided additional information leading to lesion characterization. Staging of disease and patient management were affected in 5 of 15 (33%) and 6 of 15 (40%) patients, respectively. CONCLUSION: Ferumoxtran-10 is a promising contrast agent for the evaluation of focal splenic lesions.

Adult↗

Clinical applications of magnetic resonance cholangiopancreatography.

Magnetic resonance cholangiopancreatography (MRCP) is a novel imaging technique used for noninvasive work-up of patients with pancreaticobiliary disease. Magnetic resonance cholangiopancreatography is useful in the evaluation of a host of pancreaticobiliary disorders, such as congenital disorders, calculus disease, biliary strictures, sclerosing cholangitis, chronic pancreatitis, and cystic pancreatic lesions. It not only provides useful preoperative information to surgeons and gastroenterologists but also serves as a valuable tool in the assessment of postoperative pancreaticobiliary ductal anatomy. Recent refinement of techniques allows faster imaging with superior image resolution. This review summarizes the role of MRCP in clinical practice.

Biliary Tract Diseases↗

Delayed occurrence of a severe cutaneous reaction in a multiple sclerosis patient taking interferon beta-1b.

We report a case of a patient treated for relapsing multiple sclerosis (MS) with interferon beta-1b who developed a severe vasculitic-like skin reaction 9 months after initiation of interferon therapy. Prompt discontinuation of interferon beta-1b and institution of corticosteroid therapy was associated with complete resolution of the cutaneous lesions. Other potential causative agents were excluded by penicillin skin sensitivity testing or continuing use in the absence of adverse reactions. We conclude that a vasculitic-like cutaneous reaction to interferon beta-1b may occur long after institution of therapy in some MS patients. We review other case reports of severe cutaneous reactions associated with interferon beta-1b therapy in MS patients that suggest that susceptibility cofactors may be important elements in the occurrence of these reactions, and consider whether other medications commonly used in MS patients could have such a role.

Adult↗

Detection of malignant primary hepatic neoplasms with gadobenate dimeglumine (Gd-BOPTA) enhanced T1-weighted hepatocyte phase MR imaging: results of off-site blinded review in a phase-II multicenter trial.

OBJECTIVE: To investigate the efficacy of gadobenate dimeglumine (Gd-BOPTA) enhanced MR imaging for the detection of liver lesions in patients with primary malignant hepatic neoplasms. MATERIALS AND METHODS: Thirty-one patients with histologically proven primary malignancy of the liver were evaluated before and after administration of Gd-BOPTA at dose 0.05 or 0.10 mmol/kg. T1-weighted spin echo (T1W-SE) and gradient echo (T1W-GRE) images were evaluated for lesion number, location, size and confidence by three off-site independent reviewers and the findings were compared to reference standard imaging (intraoperative ultrasound, computed tomography during arterial portography or lipiodol computed tomography). Results were analyzed for significance using a two-sided McNemar's test. RESULTS: More lesions were identified on Gd-BOPTA enhanced images than on unenhanced images and there was no significant difference in lesion detection between either concentration. The largest benefit was in detection of lesions under 1 cm in size (7 to 21, 9 to 15, 16 to 18 for reviewers A, B, C respectively). In 68% of the patients with more than one lesion, Gd-BOPTA increased the number of lesions detected. CONCLUSION: Liver MR imaging after Gd-BOPTA increases the detection of liver lesions in patients with primary malignant hepatic neoplasm.

Adenoma, Liver Cell↗