Search PubMed⌕ Search

Biomedical subjects

S Sack

Publications and source records attributed to S Sack.

At least 37 records · Page 2Linked to original sources

Size of emptied plaque cavity following spontaneous rupture is related to coronary dimensions, not to the degree of lumen narrowing. A study with intravascular ultrasound in vivo.

OBJECTIVE: To identify any potential relations between the size of an emptied plaque cavity and the remodelling pattern, plaque or vessel dimensions, lumen narrowing, and other ultrasonic lesion characteristics. DESIGN: Intravascular ultrasound was used to examine prospectively 51 ruptured ulcerated coronary plaques. Cross sectional area measurements comprised lumen, vessel, plaque, and emptied plaque cavity. Lumen narrowing was calculated as 1 - (lesion lumen area/reference lumen area) x 100%. A remodelling index was calculated as lesion vessel area/reference vessel area, and plaques were divided into those with values > 1.05 (group A) and </= 1.05 (group B). RESULTS: Of the total of 51 plaques, 36 (71%) were assigned to group A and 15 (29%) to group B. In neither group was there a significant difference in reference dimensions and lumen narrowing. However, lesion vessel (mean (SD): 22.6 (8.1) mm(2) v 17. 5 (4.3) mm(2); p = 0.006) and plaque areas (15.8 (6.2) mm(2) v 12.8 (3.2) mm(2); p = 0.03) were greater in group A than in group B. The cavity inside the plaque was larger in group A than in group B (2.8 (1.6) mm(2) v 1.8 (0.9) mm(2); p = 0.007) and showed a positive linear relation with lesion and reference vessel size (r = 0.58 and 0.56, respectively; p < 0.001), but not with lumen narrowing. CONCLUSIONS: The size of the emptied cavity inside ruptured plaques is on average larger in lesions with adaptive vascular remodelling, and shows a linear relation with lesion plaque and vessel size and with the reference dimensions, but not with the degree of lumen narrowing.

Adult↗

Crystallization of a macromolecular ring assembly of tubulin liganded with the anti-mitotic drug podophyllotoxin.

The interaction of the anti-cancer drug podophyllotoxin with a high-molecular-weight assembly of tubulin has been employed to produce three-dimensional crystals from avian erythrocyte tubulin as well as from pig brain tubulin. Avian erythrocyte tubulin crystals belong to the space group C2 with unit cell dimensions a = 740 A, b = 330 A, c = 460 A, beta = 128 degrees. The basis of these crystals is ring oligomers with a molecular mass of approximately 6 x 10(6) Da. So far, the crystals diffract to 8-A resolution and a first complete data set to 12-A resolution has been collected under cryogenic conditions. The crystals grew from conventionally purified tubulin consisting of multiple isoforms and different posttranslational modifications. Thus, the use of highly homogeneous tubulin preparations should improve the diffraction quality of these crystals.

Animals↗

Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure. The Pacing Therapies for Congestive Heart Failure Study Group. The Guidant Congestive Heart Failure Research Group.

BACKGROUND: Previous studies of pacing therapy for dilated congestive heart failure (CHF) have not established the relative importance of pacing site, AV delay, and patient heterogeneity on outcome. These variables were compared by a novel technique that evaluated immediate changes in hemodynamic function during brief periods of atrial-synchronous ventricular pacing. METHODS AND RESULTS: Twenty-seven CHF patients with severe left ventricular (LV) systolic dysfunction and LV conduction disorder were implanted with endocardial pacing leads in the right atrium and right ventricle (RV) and an epicardial lead on the LV and instrumented with micromanometer catheters in the LV, aorta, and RV. Patients in normal sinus rhythm were stimulated in the RV, LV, or both ventricles simultaneously (BV) at preselected AV delays in a repeating 5-paced/15-nonpaced beat sequence. Maximum LV pressure derivative (LV+dP/dt) and aortic pulse pressure (PP) changed immediately at pacing onset, increasing at a patient-specific optimal AV delay in 20 patients with wide surface QRS (180+/-22 ms) and decreasing at short AV delays in 5 patients with narrower QRS (128+/-12 ms) (P<0.0001). Overall, BV and LV pacing increased LV+dP/dt and PP more than RV pacing (P<0.01), whereas LV pacing increased LV+dP/dt more than BV pacing (P<0.01). CONCLUSIONS: In this population, CHF patients with sufficiently wide surface QRS benefit from atrial-synchronous ventricular pacing, LV stimulation is required for maximum acute benefit, and the maximum benefit at any site occurs with a patient-specific AV delay.

Aged↗

Can right-sided atrioventricular sequential pacing provide benefit for selected patients with severe congestive heart failure?

This study reports on the methods and results of applying right-sided atrioventricular (AV) pacing in 26 patients with advanced cardiomyopathy. Ten of these patients had ischemic cardiomyopathy. Of the 16 patients with nonischemic cardiomyopathy, 10 were idiopathic and 6 were due to secondary causes. The patients had a mean age of 56 +/- 12 years and a left ventricular ejection fraction of 26 +/- 11%. Two transvenous stimulation electrodes were temporarily placed in the high right atrium and right ventricle, respectively. A Swan Ganz catheter was positioned into the pulmonary artery to determine cardiac output by the thermodilution method and to measure the pressure in the pulmonary artery and right atrium. In addition, aortic pressure was measured through a catheter sheath via the right femoral artery. Systemic and pulmonary vascular resistance were calculated. Stimulation was performed in VVI and DDD pacing modes using different AV intervals (40, 80, 125, 150, 175, 200, and 250 msec). No increase of cardiac output was observed for the overall study cohort (p = 0.51). At VVI pacing, stroke volume significantly decreased from 66 +/- 20 mL to 53 +/- 13 mL (p < 0.01). We distinguished between responders who developed an increase of cardiac output of > 1 L/min (n = 12, 46%) and nonresponders (n = 14, 54%). Etiology of either ischemic or nonischemic cardiomyopathy for responders, as well as conduction disturbances (first-degree AV block, LBBB, RBBB), were equally distributed among both groups. Using an AV delay of 150 and 175 msec, responders to DDD pacing derived a significant increase in cardiac output. An AV delay of 150 msec produced both a significant increase of stroke volume and decrease of systemic vascular resistance. In 46% of patients with dilated cardiomyopathy of either ischemic or nonischemic origin, right-sided AV-sequential pacing brought about an improvement of left ventricular function in terms of enhanced cardiac output. We suggest individual testing in all patients with severe left ventricular dysfunction to find responders.

Adult↗

The Pacing Therapies for Congestive Heart Failure (PATH-CHF) study: rationale, design, and endpoints of a prospective randomized multicenter study.

In conjunction with pharmacologic therapy, pacing has been proposed as a potential treatment to decrease symptoms in patients with moderate-to-severe congestive heart failure (CHF). Uncontrolled studies of pacing therapy for CHF dealing with different pacing sites, modes of pacing, and atrioventricular delays have reported mixed outcomes. The Pacing Therapies in Congestive Heart Failure (PATH-CHF) study is a single-blind, randomized, crossover, controlled trial designed to evaluate the effects of pacing on acute hemodynamic function and to assess chronic clinical benefit in patients with moderate-to-severe CHF. The effect of pacing on oxygen consumption at peak exercise and at anaerobic threshold during cardiopulmonary exercise tests, and on 6-minute walk distance, have been selected as primary endpoints of the study. Secondary endpoints of the trial were changes in New York Heart Association (NYHA) functional class, quality-of-life as assessed by the Minnesota Living with Heart Failure questionnaire, and hospitalization frequency. Finally, changes in ejection fraction, cardiac output, and filling pattern were assessed by echocardiography. The trial was planned to include 53 patients from 7 centers in Europe over a period of 3 years. The study was divided into 2 parts: acute testing and chronic follow-up. The acute study, performed during the pacemaker implantation, involved extensive testing using a custom-designed computer (FLEXSTIM) and a unique burst pacing protocol (FLEXSTIM protocol) to determine the best ventricular pacing sites and the most appropriate atrioventricular delays. The chronic phase consisted of a crossover study designed to test in each patient the best univentricular pacing site and biventricular pacing as assessed by the acute hemodynamic study. The study started with the first implant in 1995 and has, to date, included 42 patients. The study is expected to be completed by the end of 1998. The results of a first interim analysis showed trends toward improvement in all primary and secondary endpoints during the pacing periods compared with no pacing.

Adult↗

Transvenous biventricular pacing for heart failure: can the obstacles be overcome?

Despite increasing evidence of hemodynamic benefit and long-term improvement in clinical status of congestive heart failure (CHF) patients with left ventricular and biventricular pacing, the risks and technical limitations of placing a permanent left ventricular pacing lead have prevented widespread clinical adoption of this therapy. Results of this and other recent investigations suggest it is necessary to target specific sites on the left ventricle to maximize hemodynamic benefit. However, limitations and variations of coronary vein anatomy, as well as patient safety, lead dislodgement, pacing thresholds, lead handling, and ease-of-use issues, present technical challenges for current transvenous permanent pacing lead designs. However, a new transvenous lead system based on an over-the-wire design appears to solve many of these problems and has proved feasible in acute clinical studies.

Animals↗

Early clinical experience with the implantation of a novel synthetic coronary stent graft.

Coating stents with autologous venous grafts has been suggested to prevent problems associated with conventional stenting, but the need for surgical vessel harvest hampered broad application. A novel synthetic coronary stent graft (CSG) overcomes this limitation by a synthetic membrane, fixed between two thin metallic stents. We successfully implanted 21 CSGs in 18 patients for treatment of acute coronary rupture, thrombus-containing lesions, and lesions with plaque rupture or adjacent pseudoaneurysm. Substantial residual angiographic diameter stenoses were seen in seven CSGs (25% +/- 10% vs. 8% +/- 6%; P < 0.01), which were implanted with relatively small balloon catheters (balloon-to-artery ratio 1.00 +/- 0.09 vs. 1.24 +/- 0.18; P = 0.01) and required postdilatation. Overall, the largest balloon catheter applied measured 4.0 +/- 0.7 mm (balloon-to-artery ratio 1.21 +/- 0.20) and the inflation pressure was 16 +/- 3 atm. Final intravascular ultrasound imaging demonstrated adequate and symmetrical expansion of the CSG (> or = 85% +/- 15% of the reference lumen). Elective implantation was associated with two small non-Q-wave myocardial infarctions, resulting from unavoidable occlusions of side branches. Thus, implantation of CSG is feasible and safe. Adequate expansion can be achieved by the use of relatively large low-compliant balloon catheters inflated with high pressure.

Angioplasty, Balloon, Coronary↗

Role of intravascular ultrasound imaging in identifying vulnerable plaques.

UNLABELLED: A plaque that has a large lipid core and a thin fibrous cap may undergo rupture. Once it ruptures, it may lead to thrombus formation and subsequent vessel occlusion. To identify unstable plaques before they rupture is essential for clinical management and patient's prognosis. Intravascular ultrasound (IVUS) opens a new window for the assessment of plaque morphology to identify vulnerable plaques and plaque rupture. We examined 144 patients with angina and ischemic ECG changes using IVUS. Ruptured plaques, characterized by a plaque cavity and a tear on the thin fibrous cap, were identified in 31 patients (group A) of which 23/31 (74%) clinically presented as unstable angina. Plaque rupture was confirmed by injecting contrast medium filling the plaque cavity during IVUS examination. Of the patients without plaque rupture (group B, n = 108), only 19 (18%) had unstable angina. No significant differences between the 2 groups were found concerning the vessel and plaque areas (p > 0.05). The percent stenosis in group A (56.2 +/- 16.5%) was significantly lower than in group B (67.9 +/- 13.4%) (p < 0.001). Area of the plaque cavity in group A (4.1 +/- 3.2 mm2) was significantly larger than the echolucent zone in group B (1.32 +/- 0.79 mm2) (p < 0.001). The plaque cavity/plaque ratio in group A (38.5 +/- 17.1%) was larger than the echolucent area/plaque ratio in group B (11.2 +/- 8.9%) (p < 0.001). The thickness of the fibrous cap in group A (0.47 +/- 0.20 mm) was significantly thinner than that (0.96 +/- 0.94 mm) in group B (p < 0.001). CONCLUSIONS: Plaques seem to be prone to rupture when the echolucent area is larger than 1 mm2, the echolucent area/plaque ratio greater than 20% and the fibrous cap thinner than 0.7 mm. IVUS has the capacity of identifying plaque rupture and vulnerable plaques. This may have potential influence on patients management and therapy.

Adult↗

[Interventions in congenital heart disease and their sequelae in adults].

The advancements of cardiac surgery over the last decades led to larger numbers of patients with operated congenital heart diseases surviving into adulthood. In Germany it is estimated that over 120,000 adults have operated congenital heart diseases. Five to 7% of them will need yearly hospital admissions. Interventional procedures are additional tools used to treat these patients with various sequelae or residua (Table 1). In the following review we concentrate on 2 different interventional procedures: dilatation and stent implantations for treatment of stenosis and the different devices used for the closure of shunt lesions. For congenital valvular pulmonary stenosis, balloon dilatation is the therapy of choice regardless the age of the patient. Stent implantation for the treatment of peripheral pulmonary stenosis (e.g., after previous systemic pulmonary shunts) can decrease the need for redo surgery, which is accompanied with increased risk. Stent implantations proved also to be useful to treat stenoses after Mustard patch in patients with transposition of the great arteries, after Fontan procedures or dealing with the rare pulmonary venous stenosis. In contrast, dilatation of bioprosthesis and conduit stenosis are not promising. Balloon dilatation of valvular aortic stenosis is an accepted therapy in childhood up to adolescents. Table 2 compares a surgical series including many infants with critical aortic stenosis with a series of balloon dilatation in children and another one in adults regarding lethality, complications, and results. Table 3 illustrates the immediate and late results of balloon dilatation of aortic coarctation in 3 different studies. The high recurrence rate in infants made clinicians refrain from taking this age group for balloon dilatation. In children and adult patients, good results are reported (75% reduction of gradients). The complication rate is low (2.3 to 3.3%) and aneurysm formation rate seldom (1 to 7%). Stenosed aorto-pulmonary collaterals will rarely need balloon dilatation. Surgical closure of atrial septal defect is a low risk procedure with a very low rate of residual shunts (2%). Of the 5 available devices for transcatheter closure of atrial septal defect Type II, only 2 occluders are in use in Germany, the Clamshell and the Amplatzer device. The largest clinical studies of the different systems, their efficacy, complications and residual shunt rate are presented in Table 4. For the deployment of these occluders a TEE is always needed. There are many more systems in clinical use to close the patent arterial duct (PDA) (Table 5). The Ivalon plug as well as the Rashkind device have probably only historical value. Different types of coils (Gianturco, Cook detachable, PFM) are now in use worldwide. The reason for their widespread use, besides their easy application, is the fact that most coils are relatively cheap and need only small sheaths for deployment. Their further evaluation identified a residual shunt rate of 5% as well as a number of complications (embolization, hemolysis, stenosis of the left pulmonary artery) in 0 to 6%. For the large PDA the Amplatzer device has recently been introduced. An additional indication for the use of the different occluding devices are aorto-pulmonary collaterals, venovenous fistulae, pulmonary or coronary artery fistulae. Aorto-pulmonary collaterals are often associated with complex cardiac lesions and occasionally appear after palliative procedures. An excellent cooperation between adult and pediatric cardiologists is needed in order to offer the group of adults with congenital heart diseases an adequate and comprehensive management.

Adult↗

Prevalence of microvascular disease in patients with significant coronary artery disease.

Coronary flow velocity reserve (CFVR) measurement using intracoronary Doppler techniques has been increasing accepted for the assessment of physiological significance of epicardial stenosis and the functional changes after coronary interventions. However, large discrepancy exists concerning the acute changes of CFVR immediately after intervention. The purpose of this study was to investigate the prevalence of microvascular dysfunction in patients with significant coronary artery disease. Intracoronary Doppler flow measurements were performed in a total of 212 patients who underwent coronary interventions because of significant epicardial stenosis using 0.014" Doppler flow wire (Cardiometrics, Inc, Mountain View, CA). Intracoronary bolus injection of adenosine (12 micrograms for the right coronary and 18 micrograms for the left coronary arteries) was used to induce hyperemic reaction. CFVR was registered as the ratio of average peak velocity during hyperemia (hAPV) to at baseline (bAPV). Successful coronary interventions either by percutaneous transluminal coronary balloon angioplasty (PTCA) or by stenting could significantly improve the CFVR. In 80 patients with PTCA, the bAPV elevated from 16.6 +/- 2.1 cm/s to 20.6 +/- 13.4 cm/s and hAPV from 30.1 +/- 15.9 cm/s to 45.2 +/- 17.7 cm/s (both p < 0.001) with PTCA and the CFVR increased from 1.94 +/- 0.78 to 2.58 +/- 0.87 correspondingly (p < 0.001). Significant elevation of coronary flow parameters were also found in 132 patients with subsequent stent implantation (bAPV from 15.3 +/- 6.7 cm/s to 18.7 +/- 9.1 cm/s, hAPV from 28.7 +/- 14.4 cm/s to 44.3 +/- 17.7 cm/s and CFVR from 1.90 +/- 0.70 to 2.59 +/- 0.87, all p < 0.001). Reduction of CFVR (< 3.0) after intervention still existed in 46 (61.3%) of 80 patients after PTCA and 88 (66.7%) of 132 patients after stenting. Moreover, CFVR < 3.0 were found in 50 (45.9%) of 109 reference vessels in patients with single vessel disease. Significant improvement of coronary flow velocity and coronary flow velocity reserve could be obtained after successful angioplasty. However, microvascualr dysfunction existed in a large proportion of patients either in normal reference vessels or in target vessels after interventions.

Adult↗

Does remodeling occur in the diseased human saphenous vein bypass grafts? An intravascular ultrasound study.

BACKGROUND: Coronary artery remodeling is a common phenomenon in human atherosclerotic arteries. Controversies exist concerning the presence of absence of the remodeling process in diseased human coronary saphenous vein bypass grafts. The purpose of the study was to observe the vessel and lumen dimensions in patients who had undergone saphenous vein grafting with intravascular ultrasound to find out whether the remodeling process exists in the diseased human saphenous vein bypass grafts. METHODS: A total of 43 saphenous vein bypass grafts from 43 patients (39 males, 4 females, mean age 63+/-8 years); 1-16 years (mean 9.3+/-4.0 years) after grafting, who had not undergone previous catheter intervention, were studied using intravascular ultrasound. The vessel, lumen and plaque area were measured at the lesion segment as well as in the proximal and distal reference segments. The percent stenosis was calculated. RESULTS: In 43 bypass grafts having severe stenosis before intervention, plaque was eccentric in 69.4% and concentric in 30.6%. No calcification was detected in 75% cases and 25% cases has mild-moderate intimal calcification. The vessel area in the lesion segment was 19.0+/-9.7 mm2, significantly larger than the proximal reference segment 12.8+/-4.0 min2 as well as the distal reference segment 12.9+/-3.6 mm2 (p < 0.001). It was also larger than that of the average area of the proximal and distal reference segments (p < 0.001). The vessel area increased in accordance with plaque area (p < 0.001). A weak relationship existed between vessel area and percent stenosis (r = 0.37, p = 0.04). CONCLUSION: In contrary to previous findings, diseased human saphenous vein bypass grafts undergo focal compensatory enlargement (remodeling) in the presence of plaque formation. The underlying mechanism is probably similar to that in de novo atherosclerosis.

Adaptation, Physiological↗

Motor proteins of the kinesin family. Structures, variations, and nucleotide binding sites.

Microtubule-dependent motors of the kinesin family convert the energy from ATP hydrolysis into mechanical work in order to transport vesicles and organelles along microtubules. The motor domains of several kinesins have been solved by X-ray diffraction, but the conformational changes associated with force development remain unknown. Here we describe conformational properties of kinesin that might be related to the mechanism of action. First, we have evaluated the conformational variability among all known kinesin structures and find they are concentrated in six areas, most of which are functionally important either in microtubule binding or in linking the core motor to the stalk. Secondly, we show that there is an important difference between kinesins when compared with myosins or GTPases (with which kinesin motor domains bear structural and catalytic similarities); in the diphosphate-state (with bound ADP), all kinesins show a 'tight' nucleotide-binding pocket, comparable with myosin or GTPases in the triphosphate state, whose nucleotide-binding pockets become open, or 'loose', following nucleotide hydrolysis. Thus, kinesin-ADP appears to be in a tense state, resembling that observed in myosin-ATP or p21ras-GTP.

Animals↗

New signs characteristic of myocardial bridging demonstrated by intracoronary ultrasound and Doppler.

BACKGROUND: Large discrepancies exist concerning the incidence of myocardial bridging. This has been reported to be 0.5%-2.5% following coronary angiography but 15%-85% following autopsy. The purpose of the study was to use intravascular ultrasound and intracoronary Doppler to study the morphology and flow characteristics of myocardial bridging in order to find feasible parameters of this syndrome. METHODS AND RESULTS: Intravascular ultrasound was performed in 62/69 patients in whom typical angiographic 'milking effects' were present. In 48 patients, intracoronary Doppler was performed. A specific, echolucent 'half moon' phenomenon surrounding the myocardial bridge was found in all the patients. The thickness of the half moon area was 0.47 +/- 0.19 mm in diastole and 0.52 +/- 0.23 mm in systole. There was systolic compression of the myocardial bridge with a lumen reduction during systole of 36.4 +/- 8.8%. Using intracoronary Doppler, a characteristic early diastolic 'finger tip' phenomenon was observed in 42 (87%) of the patients. All patients showed no or reduced antegrade systolic flow. Coronary flow velocity reserve was 2.03 +/- 0. 54. After intracoronary nitroglycerin injection, retrograde systolic flow occurred in 37 (77%) of the 48 patients, with a velocity of -22. 2 +/- 13.2 cm. s(-1). Intravascular ultrasound revealed atherosclerotic involvement of the proximal segment in 61 (88%) of the 69 patients, with an area stenosis of 42 +/- 13%. No plaques were found in the bridge or distal segments in the 62 patients in whom it was possible to introduce the ultrasound catheter throughout the bridging segment. CONCLUSION: Myocardial bridging is characterized by the following morphological and functional signs: a specific, echolucent half moon phenomenon over the bridge segment, which exists throughout the cardiac cycle; systolic compression of the bridge segment of the coronary artery; accelerated flow velocity at early diastole (finger-tip phenomenon); no or reduced systolic antegrade flow; decreased diastolic/systolic velocity ratio; retrograde flow in the proximal segment, which is provoked and enhanced by nitroglycerin injection.

Blood Flow Velocity↗

Effects of defibrillator implantation testing on myocardial metabolism.

BACKGROUND: The effects of fibrillation/defibrillation episodes (FDEs) during defibrillator implantation on myocardial metabolism were investigated at various defibrillation energies in patients with different cardiac pathologies. METHODS: Myocardial lactate extraction (MLE) was examined during defibrillation threshold (DFT) testing in patients with either coronary artery disease (CAD, n = 20) or non-ischemic cardiomyopathy (CM, n = 10). Defibrillation pulses were released 15 seconds after induced fibrillation. A test cycle of four FDEs separated by 2-minute intervals was applied in each case. RESULTS: Mean MLE decreased significantly from 28 +/- 4% before FDEs to 8 +/- 5% immediately after all episodes in CAD patients, but recovered to 27 +/- 7% within 2 minutes even in patients with reduced left-ventricular function. In patients with CM mean MLE decreased markedly from 29 +/- 3% to -11 +/- 3% immediately after each FDE but increased to baseline (33 +/- 8%) within the recovery period. MLE changes were independent of defibrillation energy in all cases. CONCLUSIONS: Myocardial lactate production, suggesting cardiac ischemia, was observed in patients with CM, but not in patients with CAD. But recovery of myocardial lactate extraction was not faster in CAD patients, indicating that the fixed FDE cycle used was well tolerated by all patients.

Adult↗

Screening of ruptured plaques in patients with coronary artery disease by intravascular ultrasound.

AIM: To visualise the characteristics of ruptured plaques by intravascular ultrasound (IVUS) and to correlate plaque characteristics with clinical symptoms to establish a quantitative index of plaque vulnerability. METHODS: 144 consecutive patients with angina were examined using IVUS. Ruptured plaques, characterised by a plaque cavity and a tear on the thin fibrous cap, were identified in 31 patients (group A), of whom 23 (74%) presented with unstable angina. Plaque rupture was confirmed by injecting contrast medium filling the plaque cavity during IVUS examination. Of the patients without plaque rupture (group B, n = 108), only 19 (18%) had unstable angina. RESULTS: No significant differences were found between groups A and B in relation to plaque and vessel area (p > 0.05). Mean (SD) per cent stenosis in group A was less than in group B, at 56.2 (16.5)% v 67.9 (13.4)%; p < 0.001. Area of the emptied plaque cavity in group A (4.1 (3.2) mm2) was larger than the echolucent zone in group B (1.32 (0.79) mm2) (p < 0.001). The plaque cavity to plaque ratio in group A (38.5 (17.1)%) was larger than the echolucent area to plaque ratio in group B (11.2 (8.9)%) (p < 0.001). The thickness of the fibrous cap in group A was less than in group B, at 0.47 (0.20) mm v 0.96 (0.94) mm; p < 0.001. CONCLUSIONS: Plaques seem to be prone to rupture when the echolucent area is larger than 4.1 (3.2) mm2, when the echolucent area to plaque ratio is greater than 38.5 (17.1)%, and when the fibrous cap is thinner than 0.7 mm. IVUS can identify plaque rupture and vulnerable plaques. This may influence patient management and treatment.

Adult↗

Image reconstructions of microtubules decorated with monomeric and dimeric kinesins: comparison with x-ray structure and implications for motility.

We have decorated microtubules with monomeric and dimeric kinesin constructs, studied their structure by cryoelectron microscopy and three-dimensional image reconstruction, and compared the results with the x-ray crystal structure of monomeric and dimeric kinesin. A monomeric kinesin construct (rK354, containing only a short neck helix insufficient for coiled-coil formation) decorates microtubules with a stoichiometry of one kinesin head per tubulin subunit (alpha-beta-heterodimer). The orientation of the kinesin head (an anterograde motor) on the microtubule surface is similar to that of ncd (a retrograde motor). A longer kinesin construct (rK379) forms a dimer because of the longer neck helix forming a coiled-coil. Unexpectedly, this construct also decorates the microtubule with a stoichiometry of one head per tubulin subunit, and the orientation is similar to that of the monomeric construct. This means that the interaction with microtubules causes the two heads of a kinesin dimer to separate sufficiently so that they can bind to two different tubulin subunits. This result is in contrast to recent models and can be explained by assuming that the tubulin-kinesin interaction is antagonistic to the coiled-coil interaction within a kinesin dimer.

Animals↗