Search PubMed⌕ Search

Biomedical subjects

S S Vasanawala

Publications and source records attributed to S S Vasanawala.

4 recordsLinked to original sources

Characterization and reduction of the transient response in steady-state MR imaging.

Refocused steady-state free precession (SSFP) imaging sequences have recently regained popularity as faster gradient hardware has allowed shorter repetition times, thereby reducing SSFP's sensitivity to off-resonance effects. Although these sequences offer fast scanning with good signal-to-noise efficiency, the "transient response," or time taken to reach a steady-state, can be long compared with the total imaging time, particularly when using 2D sequences. This results in lost imaging time and has made SSFP difficult to use for real-time and cardiac-gated applications. A linear-systems analysis of the steady-state and transient response for general periodic sequences is shown. The analysis is applied to refocused-SSFP sequences to generate a two-stage method of "catalyzing," or speeding up the progression to steady-state by first scaling, then directing the magnetization. This catalyzing method is compared with previous methods in simulations and experimentally. Although the second stage of the method exhibits some sensitivity to B(1) variations, our results show that the transient time can be significantly reduced, allowing imaging in a shorter total scan time. Magn Reson Med 46:149-158, 2001.

Humans↗

Linear combination steady-state free precession MRI.

A new, fast, spectrally selective steady-state free precession (SSFP) imaging method is presented. Combining k-space data from SSFP sequences with certain phase schedules of radiofrequency excitation pulses permits manipulation of the spectral selectivity of the image. For example, lipid and water can be resolved. The contrast of each image depends on both T1 and T2, and the relative contribution of the two relaxation mechanisms to image contrast can be controlled by adjusting the flip angle. Several potential applications of the technique, referred to as linear combination steady-state free precession (LCSSFP), are demonstrated: fast musculoskeletal, abdominal, angiographic, and brain imaging.

Blood Vessels↗

Prospective MR signal-based cardiac triggering.

A cardiac motion compensation method using magnetic resonance signal-based triggering is presented. The method interlaces a triggering pulse sequence with an imaging sequence. The triggering sequence is designed to measure aortic blood velocity, from which cardiac phase can be inferred. The triggering sequence is executed repeatedly and the acquired data processed after each sequence iteration. When the desired phase of the cardiac cycle is detected, data are acquired using the imaging sequence. A signal-processing unit of a conventional scanner is used to process the triggering data in real time and issue triggering commands. Alternatively, a workstation, with a bus adaptor, can access data as they are acquired, process and display the data, and issue triggering commands. With a graphical user interface, the triggering pulse sequence and data-processing techniques can be modified instantaneously to optimize triggering. The technique is demonstrated with coronary artery imaging using both conventional two-dimensional Fourier transform scans and spiral trajectories.

Aorta, Thoracic↗

Fluctuating equilibrium MRI.

A new fast, spectrally selective imaging method called fluctuating equilibrium magnetic resonance is presented. With all gradients refocused over a repetition interval, certain phase schedules of radiofrequency excitation pulses produce an equilibrium magnetization that fluctuates from excitation to excitation, thus permitting simultaneous acquisition of several images with different contrast features. For example, lipid and water images can be rapidly acquired. The effective echo time can be adjusted using the flip angle, thus providing control over the T(2) contribution to the contrast. Several applications of the technique are presented, including fast musculoskeletal, abdominal, breast, and brain imaging, in addition to MR angiography. A technique for combining lipid and water images generated with this sequence for angiography is described and other potential applications are suggested. Magn Reson Med 42:876-883, 1999.

Abdomen↗