S S Ehrmeyer

Publications and source records attributed to S S Ehrmeyer.

At least 19 recordsLinked to original sources

Electronic "Quality Control" (EQC): is it just for unit use devices?

The US Clinical Laboratory Improvement Amendments of 1988 (CLIA'88) mandated daily quality control (QC) for all laboratory tests. CLIA'88 clearly envisioned traditional, matrix-based controls. However, recent interpretations allow routine use of "electronic" controls (EQC). These surrogate controls, reference cassettes, glass filters, electronic signals, etc., evaluate the photometric, electronic and computational components of the test system. EQC does not evaluate chemical reactions, sample and reagent manipulations, etc. When compared to traditional concepts, it represents a discontinuity in logic and subverts the fundamental purpose of QC. The advent of "unit-use" test systems (reagent packs, cassettes, cartridges, etc.) used primarily in decentralized testing locations opened the door to EQC. The rationale behind EQC is that if the test system is operating within specifications and the manufacturer reliably delivers consistent and uniform quality products, a simple electronic check will assure that the entire testing process is in control. Unrecognized test system failure is the most insidious problem facing today's instruments using EQC-based systems. We cite positive and negative examples. We also ask, "If EQC is accepted, from a regulatory perspective for some instruments, why not for all?" Is the next step universal EQC, for all systems, inevitable?

Electronics↗

Effect of legislation (CLIA'88) on setting quality specifications for US laboratories.

The Clinical Laboratory Improvement Amendments of 1988 (CLIA'88) mandated, in response to concern over the perceived quality of clinical laboratory testing, universal regulation for all testing sites in the USA, including previously unregulated sites in physician offices. The intent of CLIA'88 is to ensure quality of testing through a combination of total quality management and mandated minimum quality practices. CLIA also defines, intentionally or unintentionally, through its proficiency testing requirements, intralaboratory performance standards. Meeting these requirements has been a prime motivator in improving laboratory performance. Seven years after the implementation of CLIA'88, the percentage of laboratories passing proficiency testing has increased and most laboratories have implemented quality practices.

Clinical Laboratory Techniques↗

The laboratory-clinical interface: point-of-care testing.

POC testing provides an opportunity for clinicians and laboratorians to work together to consider how best to serve the patients within an individual institution. Each health system has unique characteristics relative to patient population, as well as a unique laboratory structure. If physicians, nurses, laboratorians, and pathologists work collaboratively, the best interests of patients will be served. In some institutions that cater to specific patient groups, POC testing may offer clear and distinct advantages. In other institutions with sophisticated transport systems and established rapid response capabilities, the quality resulting from central laboratory testing may outweigh any advantages of bedside testing. Clearly, attention to regulatory issues, QC issues, the importance of proper documentation, proficiency testing, performance enhancement, and cost-effectiveness is requisite. As the technology for diagnostic testing advances through more microcomputerization, microchemistry, and enhanced test menus, the concept of POC testing will need perpetual revisiting. We hope that the information provided here will aid clinicians, laboratorians, and administrators in their quest to best serve their patients.

Costs and Cost Analysis↗

Quality: the next six months.

The eclectic mix of participants in the forum had a surprisingly singular focus when it came to the topic of quality in clinical laboratories. All sensed that the time is right for a transition from laws, rules, and inspections to a true quality-based system. Such a system can achieve the goals, implicit and explicit, that are the rationale for the multiplicity of regulations affecting today's laboratories. A true quality-based system has great potential benefits to laboratories, regulators, and manufacturers, and ultimately to our true customers, the patients. The benefits include lower costs, superior products, and better test results; in short, better patient care. This transition will be possible only through formation of a "Quality Alliance," composed of those skilled in the "theory" of quality-laboratory personnel, manufacturers, and regulators, acting as one to implement the quality system. The Quality Alliance requires a team of individuals with different skills, aligned as one, for the purpose of achieving a common goal. On the basis of views expressed in this Forum, our collective future will be defined by the evolving Quality Alliance, an alliance focused on true quality systems in clinical laboratories.

Chemistry, Clinical↗

Application of the Department of Health and Human Services proposed waived status requirements for in vitro diagnostic testing devices: case study.

The CLIA'88 classified all clinical laboratory testing as waived, moderate, or high complexity. The eight original waived tests were characterized as simple, accurate, error-free, risk-free, and suitable for home use by non-laboratory professionals. The subjective nature of the classification process was challenged immediately. The Clinical Laboratory Improvement Advisory Committee asked the CDC and the Health Care Financing Administration to develop objective criteria that included assessment of performance by field-test and in-house data. We examined the efficacy of the CDC protocol with empirical data from the HemoCue B-Hemoglobin Test System submission, to assess operator competency, intra-/interoperator and between-site imprecision, and accuracy. Non-laboratory-trained operators demonstrated 2-3% imprecision (40-200 g/L). Accuracy studies yielded a slope of 1.01, an intercept of 3.53 g/L, and r of 1.00 (52-230 g/L). Results met the protocol's Tonks' criterion for imprecision (less than one-fourth of the reference range).

Calibration↗

Matrix effects and the performance and selection of quality-control procedures to monitor PO2 measurements.

We have assessed how variation in the matrix of control materials would affect error detection and false-rejection characteristics of quality-control (QC) procedures used to monitor PO2 in blood gas measurements. To determine the expected QC performance, we generated power curves for S(mat)/S(meas) ratios of 0.0-4.0. These curves were used to estimate the probabilities of rejecting analytical runs having medically important errors, calculated from the quality required by the CLIA '88 proficiency testing criterion and the precision and accuracy expected for a typical analytical system. When S(mat)/S(meas) ratios are low, the effects of matrix on QC performance are not serious, permitting selections of QC procedures based on simple power curves for a single component of variation. As S(mat)/S(meas) ratios increase, single-rule procedures generally show a loss in error detection, whereas multirule procedures, including the 3(1)s control rule, show an increase in false rejections. An optimized QC design is presented.

Blood Gas Analysis↗

Regulatory requirements (CLIA '88, JCAHO, CAP) for decentralized testing.

All decentralized testing is regulated according to the Clinical Laboratory Improvement Amendments of 1988. Two organizations, the Joint Commission on Accreditation of Health Care Organizations and the College of American Pathologists, have received deemed status for their voluntary standards from the Health Care Financing Administration. Deemed status means that the organizations' voluntary standards meet or exceed the federal requirements. The decentralized testing sites can exercise several options in determining which organization, and hence which set of standards, will be used to regulate their testing processes. In this article, the authors outline the various regulatory requirements, provide insight into the relationship of each, and offer a framework for decentralized testing sites to follow to meet the requirements.

Certification↗

Health Care Financing Administration's new proficiency testing rules. Use of a statistical approach to predict long-term performance using the categories 'successful,' 'probation,' and 'suspended'.

Under the Clinical Laboratory Improvement Act of 1967 (CLIA-67) and the Medicare Act, the Health Care Financing Administration's proficiency testing rules apply uniformly to all hospital and reference laboratories. We examined the relationship between internal laboratory performance as characterized by bias and coefficient of variation and proficiency testing performance, categorized as "successful," "probation," and "suspended." Under the March 14, 1990, final rule, a laboratory with suspended testing for even one analyte may be required to cease testing in the entire subspecialty, eg, routine chemistry, unless it ceases testing for that analyte. Analyzing this regimen as a Markov process, we obtained the steady-state solution for performance for one to 27 analytes. While 1.1% of laboratories testing for five analytes with internal or day-to-day coefficients of variation at 50% of the CLIA-67 proficiency testing limit would be suspended, 19.5% of laboratories having biases of 50% and coefficients of variation of 33% would be suspended. We conclude that after eight events, there will be an unacceptably high rate of suspensions.

Centers for Medicare and Medicaid Services, U.S.↗

Intralaboratory performance requirements necessary to pass proficiency testing: CAP-1990 vs CLIA-1967 (March 14, 1990) formats compared.

The pre-1990 College of American Pathologists' (CAP) Proficiency Testing (PT) program used a two samples per analyte/four challenges per year format with performance or pass-fail grading criteria determined by the program. On Jan. 1, 1991, the Clinical Laboratory Improvement Act of 1967 (CLIA-67) final rules (March 14, 1990) mandated a revised PT format of five samples per analyte/four challenges per year, with the regulations specifying minimum performance criteria. Extending our previous analysis, we compare the maximum permissible intralaboratory imprecision at low bias compatible with passing external PT in the former CAP and current CLIA-67 formats. If a laboratory is able to reduce its internal coefficient of variation (CV) to less than 44% of the PT criterion for each analyte, its overall chance of adverse action for any of the 27 routine chemistry analytes specified in CLIA-67 will be less than 1% in a two-year (eight PT challenges or events) period. Consideration of actual interlaboratory CVs from CAP surveys suggest that a reduction of this magnitude may be difficult for the analytes total cholesterol and blood urea nitrogen, where intralaboratory imprecision comparable with the group standard deviation (SD) from 1990 CAP surveys would yield individual adverse action (PT failure) rates of 5% and 1%, respectively. Five other analytes have CLIA-67 performance limits dangerously close to CAP interlaboratory CVs.

Chemistry, Clinical↗

Limitations of proficiency testing under CLIA '67.

Proficiency testing (PT), recognized as a quality-assurance (QA) and quality-improvement tool, also has become the cornerstone of the Health Care Financing Administration's (HCFA) regulatory strategy under the revised Clinical Laboratory Improvement Act of 1967 (CLIA '67) and the proposed Clinical Laboratory Improvement Amendments of 1988 (CLIA '88). Use of PT as a regulatory tool corrupts it for things it can do better. PT as a primary regulatory strategy has severe limitations. We explore the nature of these limitations and their implications for clinical laboratories as they impact on the long-term success of HCFA's approved regulatory PT programs in 1991 and beyond, and CLIA '88 PT, which is to be implemented in 1994.

Chemistry, Clinical↗

Review of actual proficiency-testing performance under CLIA '67 (March 14, 1990) rules: perspective from the first year's data.

Under the Clinical Laboratory Improvement Act of 1967 the Health Care Financing Administration's proficiency-testing requirement applies to approximately 12,000 hospital, reference, and large-clinic laboratories in the United States. The Wisconsin State Laboratory of Hygiene is approved by the Health Care Financing Administration to provide proficiency testing in all specialties and subspecialties. The focus of the program is to provide highly specialized service and support to a limited number of participants in order to assess intralaboratory performance correctly. We report the findings over the four proficiency-testing events in 1991 for the subspecialty of routine chemistry, which serves approximately 470 participants. Failure rates for individual analytes on single proficiency testing events ranged from 0% to 13%. After four events or one year, if the mandated evaluation criteria and failure rules were strictly applied, as many as 11% of the laboratories could have found themselves involuntarily suspended from offering all routine chemistry testing.

Chemistry, Clinical↗

1990 Medicare/CLIA final rules for proficiency testing: minimum intralaboratory performance characteristics (CV and bias) needed to pass.

On March 14, 1990, the Centers for Disease Control and the Health Care Financing Administration published criteria for defining minimum performance in proficiency testing (PT). Using our previously described computer modeling technique, we determined the likelihood of passing PT under the new rules. The model relates combinations of intralaboratory CV and bias to PT performance criteria. For example, a laboratory with a bias of zero and an internal CV of 5% will pass a 10% fixed-limit PT criterion (i.e., the criterion for glucose analyses) 98% of the time when five samples are used. The model provides similar analyses for all PT criteria and all relevant combinations of CV and bias. The probability of passing PT decreases as the number of analytes tested increases, i.e., from 98% to 37% as the number of analytes increases from 1 to 20. A laboratory's internal CV has a greater effect on the outcome of PT than do the corresponding bias values. We conclude that a laboratory that operates with methods that have internal CVs less than or equal to 33% and biases less than or equal to 20% of the PT criteria will have a greater than 99% chance of passing PT.

Centers for Disease Control and Prevention, U.S.↗

The relationship of intralaboratory bias and imprecision on laboratories' ability to meet medical usefulness limits.

The previously described computer modeling technic empirically develops quantitative relationships between intralaboratory performance, as characterized by individual laboratories' coefficients of variation (CVs) and biases, and clinical "medical usefulness limits." These limits determine the magnitude of total analytic error, the combined effects of CV and bias that can be tolerated by the clinician. The computer model delineates all combinations of CV and bias compatible with specified medical usefulness limits. Both CV and bias are critical in determining a laboratory's ability to meet medical usefulness limits. For example, a laboratory with a 6% CV and zero bias will meet the +/- 10% or less total analytic error (medical usefulness limit) 90% of the time. If the medical usefulness limit is expanded to +/- 15%, a laboratory with a 6% CV can tolerate coexisting relative biases of up to 4% and still meet this limit 95% of the time. Plots of the limiting values for combinations of intralaboratory CV and bias are given that allow the laboratory's results to fall within medical usefulness limits of 2, 5, 10, 15, and 20%.

Clinical Laboratory Techniques↗

Use of computer modeling to predict the magnitude of intralaboratory error tolerated by proposed CDC interlaboratory proficiency testing performance criteria.

In December 1987, the Centers for Disease Control (CDC) proposed to the Health Care Financing Administration revised criteria for evaluating participating laboratories' performance in proficiency-testing programs. If these criteria are accepted, they will become the minimum standard for all regulatory proficiency-testing programs. To evaluate a laboratory's performance in a clinical chemistry proficiency-testing program, the CDC proposed a combination of the use of fixed limits, multiples of the interlaboratory group standard deviations, and absolute values. In addition, laboratories would be required to meet 70% of the most recent proficiency-testing challenges. Because the purpose of regulatory proficiency testing is to identify poorly performing laboratories, it is essential that regulators be aware of the relationship between the regulatory criteria and the actual magnitude of intralaboratory error they tolerate. Through computer simulation, we determined for 21 chemistry analytes the amount of intralaboratory error tolerated by the CDC-proposed criteria. We evaluated the effectiveness of the proposed criteria by comparing the levels of total intralaboratory error permitted by a proficiency-testing program by using the CDC criteria with actual currently achievable levels of performance and defined medical usefulness needs. The proposed CDC criteria were too lenient for six analytes, about correct for seven, and too stringent on two; no medical usefulness limits were available for six.

Blood Chemical Analysis↗

Use of alternative rules (other than the 1(2)s) for evaluating interlaboratory performance data.

Previous studies have documented the ineffectiveness of using either the group mean +/- 2 group standard deviations (SD) or the 1(2)s rule as the standard of acceptable performance in evaluating interlaboratory proficiency testing (PT) data. Using computer simulation of PT data, we evaluated the efficiency of 244 alternatives to the 1(2)s rule, all based on the PT population's mean and SD. Using the traditional interlaboratory PT format, we determined the ability of each rule to correctly identify both good and deficient intralaboratory performance. The rules are based on results from one to five PT samples "analyzed" at the same time. Because the effectiveness of the criteria set for acceptable performance in a PT program is influenced by the population SD, each rule's capabilities were examined for PT populations with interlaboratory SDs ranging from 1% through 10% of the population mean value. All rules achieve their maximum efficiency over a narrow range of interlaboratory SDs. For PT evaluations of intralaboratory performance to be optimally effective, selection of the rule must be based on the SD of the PT population.

Computers↗

Proficiency testing programs--promises, progress, and problems. A 40-year prospective.

Proficiency testing as a means of interlaboratory improvement is over 40 years old. Proficiency testing as a tool of the regulatory process is nearly 20. While successful, ie, the quality of laboratory work in the United States has improved significantly during the past 40 years, this union of regulation and education continues to be a marriage of unequals. Clearly, those who started the professional laboratory community on the road to interlaboratory proficiency testing envisioned a promise of improved quality. The promise is fulfilled; even on an interlaboratory basis, the quality of work (precision) approaches or even exceeds the clinicians' requirements for medically useful data. Major problems continue to exist: the prospect of regulating a vast population of "physicians' office laboratories" presents new challenges for program providers, and as methodologies in laboratories have improved, some of the long-held systems of grading and performance evaluation are beginning to fail. The failure is not one of intent, logistics, or statistics. Proficiency testing, as a fine sharp tool, is corrupted when applied in a situation in which it is ill suited to perform. New knowledge will renew the promise and allow the professional, clinical laboratory community to progress.

Clinical Laboratory Techniques↗

An evaluation of the ability of proficiency testing programs to determine intralaboratory performance. Peer group statistics vs clinical usefulness limits.

Proficiency testing programs use two basic approaches for evaluating participant performance: (1) state-of-the-art data based on the interlaboratory group mean and group SD, or the 1(2)s rule; and (2) fixed limits or assigned intervals around the true value. Our previously described computer model emulates the state-of-the-art approach by simulating the performance of 401 laboratories in interlaboratory proficiency testing programs using the 1(2)s rule. The use of fixed limits to evaluate laboratory performance can be simulated by simple probability calculations. We compare the 1(2)s rule and fixed limits on the basis of their ability to identify actual intralaboratory performance correctly using efficiency. In both cases, the maximum efficiency never exceeds 91% and depends on population SD or fixed limit, specific requirements for medical usefulness, and the prevalence (10%) of poorly performing laboratories in the proficiency testing population. This calculation gives some insight into why neither of these approaches adequately differentiates between good and bad intralaboratory performance.

Computer Simulation↗