Search PubMed⌕ Search

Biomedical subjects

S R Ramee

Publications and source records attributed to S R Ramee.

At least 73 records · Page 4Linked to original sources

Ambiguous coronary angiography: clinical utility of intravascular ultrasound.

We report the use of intravascular ultrasound (IVUS) in situations where angiography was ambiguous or uncertain in assessing the significance of coronary stenoses. The indications for performing intravascular ultrasound were 1) angiographic findings did not correlate with the clinical presentation (n = 5) and 2) the lesion was not seen well by angiography because of overlapping vessels at the site of suspected stenosis (n = 3). We studied eight lesions in seven patients. Six nonobstructive stenoses on angiography were shown by IVUS to be significant. In two patients, stenoses were thought to be significant on angiography, but, due to overlapping of the vessels, there was doubt regarding the severity of the narrowing. In these two patients, IVUS clearly showed that the lesions were nonobstructive. As seen from the above results, angiography underestimated 6/8 stenoses and overestimated in 2/8 stenoses when compared to IVUS. We conclude that IVUS can be used to clarify ambiguous angiographic findings which can have a major impact on the clinical decision making.

Aged↗

Intracoronary thrombus: chronic urokinase infusion and evaluation with intravascular ultrasound.

Percutaneous revascularization of coronary arteries with intraluminal thrombi is a clinical problem. We report a patient in whom we administered prolonged infusion of intracoronary urokinase and then assessed the stenosis with intravascular ultrasound before and after atherectomy. We found both angiography and intravascular ultrasound to be misleading in determining the presence of residual thrombus after thrombolysis.

Adult↗

Options for percutaneous coronary and peripheral revascularization.

Angioplasty has become an established treatment for both coronary and peripheral atherosclerosis, and a number of new techniques and devices promise to improve the results of percutaneous intervention during the coming decades. It is likely that balloon angioplasty will remain the percutaneous treatment of choice for both coronary and peripheral intervention; however, we look with hope toward the development of new devices that will expand the role of percutaneous angioplasty and improve the long-term success of these procedures. As technical expertise grows with the new procedures, prospective randomized trials comparing them with standard PTCA will be required to enable physicians to judge their clinical utility.

Angioplasty, Balloon, Coronary↗

Selection of patients for peripheral revascularization surgery.

The recognition of the extent of vascular disease has introduced several medical subspecialties, radiology and vascular surgery, to a multidisciplinary approach to these problems. Of particular importance is the primary care physician, who often is the first to see these patients and should be familiar with common vascular problems. Only then will initial care and disposition be appropriate.

Humans↗

Morphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging.

BACKGROUND: Histological examination of the effects of balloon angioplasty have been described from in vitro experiments and a limited number of pathologic specimens. Intravascular ultrasound imaging permits real time cross-sectional observation of the effect of balloon dilation on the atherosclerotic plaque in vivo. METHODS AND RESULTS: The morphological effects of coronary angioplasty were visualized at 66 lesions in 47 patients immediately after balloon dilatation with an intravascular ultrasound imaging catheter. Cross-sectional images were obtained at 30 frames per second as the catheter passed along the length of the artery. Quantitative and qualitative assessments of the dilated atherosclerotic plaque were made from the angiograms and the ultrasound images. Six morphological patterns after angioplasty were appreciated by ultrasound imaging. Type A consists of a linear, partial tear of the plaque from the lumen toward the media (seven lesions); Type B is defined by a split in the plaque that extends to the media (12 lesions); Type C demonstrates a dissection behind the plaque that subtends an arc of up to 180 degrees around the circumference (18 lesions); Type D was a more extensive dissection that encompasses an arc of more than 180 degrees (four lesions); and Type E may be present in either concentric (Type E1, 14 lesions) or eccentric (Type E2, 11 lesions) plaque and is defined as an ultrasound study without any evidence of a fracture or a dissection in the plaque. There was a large amount of residual atheroma in each type of morphology (7.8 +/- 2.9 mm2, 61.6 +/- 15.4% of cross-sectional area); there was no difference, however, in lumen or atheroma cross-sectional area among these six patterns. There was a good correlation between ultrasound and angiography for the recognition of a dissection. Calcification was seen in only 14% of lesions on angiography, whereas most lesions (83%) revealed calcification on ultrasound imaging. As determined by intravascular ultrasound, calcified plaque was more likely to fracture in response to balloon dilatation than noncalcified plaque (p less than 0.01). Thirteen of 66 lesions (20%) developed clinical and angiographic restenosis. Restenosis was more likely to occur when the original dilatation left a concentric plaque without a fracture or dissection (Type E1, 50% incidence) compared with a mean restenosis rate of 12% in the remaining morphological patterns (p = 0.053). CONCLUSIONS: Intravascular ultrasound provides a more complete quantitative and qualitative description of plaque geometry and composition than angiography after balloon angioplasty. In addition, intravascular ultrasound identified a subset of atherosclerotic plaque that has a higher incidence of restenosis. This information could be used prospectively to consider other therapeutic options in this subset. Intravascular ultrasound provides a method to describe the effects of angioplasty that will be useful in comparing future coronary intervention studies.

Adult↗

Guiding catheter-assisted renal artery angioplasty.

A guiding catheter was used in seven patients who underwent balloon dilation of nine renal arteries. The advantages of using a guiding catheter for renal angioplasty are analogous to the benefits obtained with a coronary angioplasty guiding catheter used in coronary angioplasty. The guiding catheter provides back-up support to cross lesions and allows selective contrast visualization of the lesion before, during, and after dilation. It is also possible, when using a guiding catheter, to measure pressure gradients across lesions without having to recross the lesion which may help to ensure that adequate dilation of the stenosis has been accomplished.

Aged↗

Recanalization of arterial occlusions with a lensed fiber and a holmium:YAG laser.

Laser recanalization of totally occluded swine iliac arteries was performed to assess the safety and efficacy of a lensed fiber laser angioplasty system with a holmium:YAG (2.1 microns) laser. Silica lenses of 1.0 mm, 1.3 mm, and 1.5 mm in diameter attached to the distal end of a 300-microns diameter silica fiber delivered fluences of 79.5 J/cm2, 31.4 J/cm2, and 25.5 J/cm2, respectively. The pulse duration of the laser was 250 microseconds and the repetition rate was 4 Hz. The mean length of the total occlusions was 5.3 +/- 2.0 cm (range 0.5 cm to 8.0 cm). Successful recanalization was obtained in 16/16 lesions without angiographic vessel perforation. Angiographically significant residual stenoses (greater than 50%) remained in every case following successful laser recanalization. Histologically there was minimal evidence of thermal or acoustic tissue injury; however, in 4 of 16 arteries there was evidence of deep arterial dissection following laser recanalization. We conclude that this lensed fiber coupled with a holmium:YAG laser is a safe and effective method for crossing total occlusions in the relatively straight iliac arteries of this animal model.

Angioplasty, Laser↗

Percutaneous angioscopy during coronary angioplasty using a steerable microangioscope.

The feasibility of using a flexible, steerable angioscope to perform coronary angioscopy before and after percutaneous coronary angioplasty was tested. The microangioscope fits through an 8F coronary angioplasty guiding catheter and contains a multifiber viewing bundle incorporated into the body of a 4.3F balloon catheter with a central lumen for distal flushing and guide-wire passage. Angioscopy was performed without complications 45 times in 24 patients, including 6 patients with stable and 18 with unstable angina. Circumferential visualization of the target lesion was successful in 20 (83%) of the 24 patients and improved with operator experience. Excellent visualization of the target lesion was achieved in 16 (94%) of the last 17 patients. Plaque, thrombus and dissection were among the abnormal findings in the 20 patients (4 with stable, 16 with unstable angina) in whom circumferential viewing of the target lesion was achieved. In four patients with restenosis after angioplasty, the lesion morphology was distinctly different from that of lesions in arteries without prior angioplasty. In patients with stable angina, no thrombus or dissection was seen by angiography or angioscopy before angioplasty. In patients with unstable angina, thrombus was detected more frequently by angioscopy than by angiography before angioplasty (8 versus 2 of 16) and after (15 versus 2 of 16) angioplasty. Intimal dissection was also seen much more frequently by angioscopy than by angiography before angioplasty (7 versus 0 of 16) and after angioplasty (16 versus 7 of 16). It is concluded that high resolution percutaneous coronary angioscopy can be performed safely in conjunction with balloon angioplasty. Further investigation is needed before this diagnostic tool can be applied clinically.

Angina Pectoris↗

Percutaneous coronary angioscopy in patients with restenosis after coronary angioplasty.

Percutaneous transluminal coronary angioscopy with a flexible steerable microangioscope was performed in five patients undergoing repeat angioplasty. Recurrent lesions were assessed by angioscopy before and after the angioplasty procedure. The most common surface morphology observed in these restenosis lesions was that of white unpigmented lesions consistent with the proliferation of fibrous tissue. Also noted during angioscopy was the presence or absence of thrombus or dissection in association with the lesions either before or after angioplasty. Filmy wisps of tissue, presumably intimal flaps, were commonly visualized after angioplasty. There were no complications related to angioscopy or angioplasty in these patients. The surface morphology of restenosis lesions appears to be different from that of primary atherosclerotic lesions. The lesions in these five patients with restenosis were generally white and fibrotic in appearance, as opposed to the pigmented yellow to yellow-brown lesions commonly seen in undilated atherosclerotic lesions. It was also noted that the presence of intracoronary thrombus was strongly associated with the clinical syndrome of unstable angina. These findings support the hypothesis that restenosis lesions are the result of a reparative process consisting of smooth muscle cell proliferation and fibrosis.

Adult↗

New directions in percutaneous intervention for peripheral vascular disease.

Balloon angioplasty is a safe and effective alternative to surgical reconstruction or bypass in selected patients with symptomatic iliofemoral and popliteal atherosclerosis. The current literature suggests an expanding role for balloon angioplasty in patients with symptomatic tibioperoneal disease as well as upper extremity claudication and subclavian steal syndrome. Newer percutaneous devices such as atherectomy, intravascular stents, and laser angioplasty may further broaden the indications for percutaneous intervention by improving their safety and long-term benefit. The latest advances in percutaneous intervention for peripheral vascular disease are reviewed.

Angioplasty, Balloon, Coronary↗

Laser angioplasty in miniature swine: advantages of a modified fiber tip delivery system.

Laser angioplasty using a spherical lensed fiber-tip laser delivery catheter and a 200 mum bare silica fiber tip was performed in occluded atherosclerotic iliac arteries of miniature swine. Group I consisted of 8 animals with 11 totally occluded arteries in which the bare silica fiber was used. Group II included 22 animals with occlusive lesions in 41 arteries in which the silica lens tip was used. In vivo laser angioplasty was performed in both groups using an argon ion laser delivering 2 to 3 watts of power in 1 to 5 second intervals. Successful recanalization occurred in 7/11 (64%) in group I arteries and 35/41 (85%) in group II arteries. Vascular perforation occurred in 36% (4/11) in group I compared to 10% (4/41) in group II (P less than 0.05). Mechanical perforation due to the bare fiber alone accounted for 50% of the perforations in group I and did not occur with the silica lens-tip device (group II). We conclude that the atraumatic lensed fiber is more effective in recanalizing occlusive lesions and is a safer delivery system than the bare silica fiber.

Angioplasty, Laser↗

New passive perfusion PTCA catheter.

Percutaneous coronary angioplasty with a new passive perfusion balloon catheter was compared to a standard angioplasty balloon catheter during prolonged balloon inflations in miniature swine. Inflations with the passive perfusion balloon were alternated with a standard balloon with the initial balloon chosen randomly in 24 coronary arteries. End-points for terminating the balloon inflation were the appearance of 2 mm of ST segment deviation from baseline on the electrocardiogram, the occurrence of ventricular fibrillation, or 30 min of balloon inflation. During balloon inflation contrast injections were performed through the guiding catheter and flow distal to the balloon was graded 0-3 using the TIMI scale. The average (+/- SD) inflation time for the standard balloon was 3.1 +/- 2.2 minutes and for the perfusion balloon was 27.2 +/- 4.8 min (P less than 0.001). Electrocardiographic evidence of 2 mm of ST segment deviation from baseline was seen during 11/13 inflations with the standard balloon and in 3/11 balloon inflations with the perfusion balloon. Ventricular fibrillation occurred during 2/13 of the standard balloon inflations and in none during passive balloon inflations. Distal contrast flow during passive balloon inflations averaged 2.7 +/- 0.5 (TIMI scale 0-3) and was absent during inflations with the standard balloon. The perfusion balloon allowed prolonged inflations with excellent distal flow when compared to the standard balloon.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

Use of a guiding catheter for contralateral femoral artery angioplasty.

We describe a unique method employing a transseptal sheath as a "guiding catheter" that allows contralateral retrograde femoral artery access to perform balloon angioplasty of proximal superficial femoral artery lesions. This technique simplifies arterial access, provides support for crossing lesions, and allows angiographic visualization of target lesions during the procedure.

Aged↗