In vivo imaging of nicotinic receptor upregulation following chronic (-)-nicotine treatment in baboon using SPECT.

To quantify changes in neuronal nAChR binding in vivo, quantitative dynamic SPECT studies were performed with 5-[(123)I]-iodo-A-85380 in baboons pre and post chronic treatment with (-)-nicotine or saline control. Infusion of (-)-nicotine at a dose of 2.0 mg/kg/24h for 14 days resulted in plasma (-)-nicotine levels of 27.3 ng/mL. This is equivalent to that found in an average human smoker (20 cigarettes a day). In the baboon brain the regional distribution of 5-[(123)I]-iodo-A-85380 was consistent with the known densities of nAChRs (thalamus > frontal cortex > cerebellum). Changes in nAChR binding were estimated from the volume of distribution (V(d) ) and binding potential (BP) derived from 3-compartment model fits. In the (-)-nicotine treated animal V(d) was significantly increased in the thalamus (52%) and cerebellum (50%) seven days post cessation of (-)-nicotine treatment, suggesting upregulation of nAChRs. The observed 33% increase in the frontal cortex failed to reach significance. A significant increase in BP was seen in the thalamus. In the saline control animal no changes were observed in V(d) or BP under any experimental conditions. In this preliminary study, we have demonstrated for the first time in vivo upregulation of neuronal nAChR binding following chronic (-)-nicotine treatment.

Animals↗

Simultaneous estimation of physiological parameters and the input function--in vivo PET data.

Dynamic imaging with positron emission tomography (PET) is widely used for the in vivo measurement of regional cerebral metabolic rate for glucose (rCMRGlc) with [18F]fluorodeoxy-D-glucose (FDG) and is used for the clinical evaluation of neurological disease. However, in addition to the acquisition of dynamic images, continuous arterial blood sampling is the conventional method to obtain the tracer time-activity curve in blood (or plasma) for the numeric estimation of rCMRGlc in mg glucose/100-g tissue/min. The insertion of arterial lines and the subsequent collection and processing of multiple blood samples are impractical for clinical PET studies because it is invasive, has the remote, but real potential for producing limb ischemia, and it exposes personnel to additional radiation and risks associated with handling blood. In this paper, based on our previously proposed method for extracting kinetic parameters from dynamic PET images, we developed a modified version (post-estimation method) to improve the numerical identifiability of the parameter estimates when we deal with data obtained from clinical studies. We applied both methods to dynamic neurologic FDG PET studies in three adults. We found that the input function and parameter estimates obtained with our noninvasive methods agreed well with those estimated from the gold standard method of arterial blood sampling and that rCMRGlc estimates were highly correlated (r = 0.973). More importantly, no significant difference was found between rCMRGlc estimated by our methods and the gold standard method (P > 0.16). We suggest that our proposed noninvasive methods may offer an advance over existing methods.

Adult↗

The influence of tomograph sensitivity on kinetic parameter estimation in positron emission tomography imaging studies of the rat brain.

We investigated the influence of tomograph sensitivity on reliability of parameter estimation in positron emission tomography studies of the rat brain. The kinetics of two tracers in rat striatum and cerebellum were simulated. A typical injected dose of 10 MBq and a reduced dose of 1 MBq were assumed. Kinetic parameters were estimated using a region of interest (ROI) analysis and two pixel-by-pixel analyses. Striatal binding potential was estimated as a function of effective tomograph sensitivity (S(eff)) using a simplified reference tissue model. A S(eff) value of > or =1% was required to ensure reliable parameter estimation for ROI analysis and a S(eff) of 3-6% was required for pixel-by-pixel analysis. We conclude that effective tomograph sensitivity of 3% may be an appropriate design goal for rat brain imaging.

Animals↗

Pharmacokinetic assessment of novel anti-cancer drugs using spectral analysis and positron emission tomography: a feasibility study.

PURPOSE: The aim of this study was to investigate the feasibility of evaluating the pharmacokinetics of radiolabeled anti-cancer drugs using spectral analysis, a non-compartmental tracer kinetic modeling technique, and positron emission tomography (PET). METHODS: Dynamic PET studies were performed on patients receiving tracer doses of 5-fluorouracil (5-[18F]-FU) and two developmental drugs [11C]-temozolomide and [11C]-acridine carboxamide. Spectral analysis was then used to (a) determine individual and group average pharmacokinetics, (b) predict tumour handling in response to different drug administration regimens, and (c) produce functional parametric images describing regional pharmacokinetics. RESULTS: Spectral analysis could distinguish tumour kinetics from normal tissue kinetics in an individual [11C]-temozolomide study and demonstrated a markedly greater volume of distribution (VD) in glioma than in normal brain, although there was no appreciable difference in mean residence time. Analysis of pooled acridine carboxamide data (n = 22) revealed a relatively large VD (and prolonged retention) in the liver and spleen and a markedly lower VD (and initial uptake) in the brain. Continuous infusion of 5-[18F]-FU was predicted to achieve a concentration in colorectal metastases in liver approximately 10 times that achieved in plasma at 10 h after commencement of the infusion. CONCLUSIONS: We conclude that spectral analysis provides important pharmacokinetic information about radiolabeled anti-cancer drugs with relatively few model assumptions.

Acridines↗

Parametric image reconstruction using spectral analysis of PET projection data.

Spectral analysis is a general modelling approach that enables calculation of parametric images from reconstructed tracer kinetic data independent of an assumed compartmental structure. We investigated the validity of applying spectral analysis directly to projection data motivated by the advantages that: (i) the number of reconstructions is reduced by an order of magnitude and (ii) iterative reconstruction becomes practical which may improve signal-to-noise ratio (SNR). A dynamic software phantom with typical 2-[11C]thymidine kinetics was used to compare projection-based and image-based methods and to assess bias-variance trade-offs using iterative expectation maximization (EM) reconstruction. We found that the two approaches are not exactly equivalent due to properties of the non-negative least-squares algorithm. However, the differences are small (< 5%) and mainly affect parameters related to early and late time points on the impulse response function (K1 and, to a lesser extent, VD). The optimal number of EM iteration was 15-30 with up to a two-fold improvement in SNR over filtered back projection. We conclude that projection-based spectral analysis with EM reconstruction yields accurate parametric images with high SNR and has potential application to a wide range of positron emission tomography ligands.

Algorithms↗

Does fluorine-18 fluorodeoxyglucose metabolic imaging of tumours benefit oncology?

Fluoro-deoxyglucose (FDG) is a metabolic marker, which follows the same route into cells as that of glucose, and it can be radiolabelled with fluorine-18, 18F-FDG making it suitable for imaging with positron emission tomography (PET). The fact that rapidly proliferating cells such as tumour cells accumulate 18F-FDG more avidly than those with a normal turnover rate has given rise to its potential in oncology. The rationale and previous published uses of 18F-FDG in oncology are reviewed, together with the various analysis techniques and associated methodological difficulties.

Deoxyglucose↗

ECAT ART - a continuously rotating PET camera: performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department.

Advances in fully three-dimensional (3D) image reconstruction techniques have permitted the development of a commercial, rotating, partial ring, fully 3D positron emission tomographic (PET) scanner, the ECAT ART. The system has less than one-half the number of bismuth germanate detectors compared with a full ring scanner with the equivalent field of view, resulting in reduced capital cost. The performance characteristics, implications for installation in a nuclear medicine department, and clinical utility of the scanner are presented in this report. The sensitivity (20 cm diameterx20 cm long cylindrical phantom, no scatter correction) is 11400 cps.kBq-1.ml-1. This compares with 5800 and 40500 cps.kBq-1.ml-1 in 2D and 3D respectively for the equivalent full ring scanner (ECAT EXACT). With an energy window of 350-650 keV the maximum noise equivalent count (NEC) rate was 27 kcps at a radioactivity concentration of approximately 15 kBq.ml-1 in the cylinder. Spatial resolution is approximately 6 mm full width at half maximum on axis degrading to just under 8 mm at a distance of 20 cm off axis. Installation and use within the nuclear medicine department does not appreciably increase background levels of radiation on gamma cameras in adjacent rooms and the dose rate to an operator in the same room is 2 microSv. h-1 for a typical fluorine-18 fluorodeoxyglucose (18F-FDG) study with an initial injected activity of 370 MBq. The scanner has been used for clinical imaging with18F-FDG for neurological and oncological applications. Its novel use for imaging iron-52 transferrin for localising erythropoietic activity demonstrates its sensitivity and resolution advantages over a conventional dual-headed gamma camera. The ECAT ART provides a viable alternative to conventional full ring PET scanners without compromising the performance required for clinical PET imaging.

Equipment Design↗

Airway closure measured by a technegas bolus and SPECT.

Absence of a maximal dose-response plateau and mathematical modeling suggest that asthmatic airways close during bronchoconstriction. Finding segmental areas affected by closure would be important in understanding asthmatic airway function. The aim of this study was to evaluate single-photon emission computed tomography (SPECT) as a method of investigating airway closure. Simultaneous SPECT transmission and emission studies were performed on a thoracic phantom to develop analysis methodology, and on 13 normal subjects after they inhaled a Technegas bolus from residual volume (RV), to measure airway closure. Single-breath nitrogen test values and lung volumes were measured. Airway closure was defined as the percent of Technegas-free lung volume (LVclosed). The mean error +/- 95% CI of the error, as determined by transmission scan, was 1.1 ml +/- 165 ml (0.8% +/- 15% lung volume) in the phantom studies, and 112 ml +/- 419 ml (4% +/- 31% of supine functional residual capacity [FRC]) in the human studies. LVclosed correlated with closing capacity (r = 0.86, p < 0.01 ) and closing volume (r = 0.86, p < 0.01), but not with RV/total lung capacity (TLC). This study indicates that simultaneous SPECT emission and transmission scans, using a Technegas bolus, are a valid method of measuring airway closure in vivo, with the added advantage of providing three-dimensional data that allow the detection of small, discrete areas of airway closure and determination of their volumes and shapes.

Adult↗

Simultaneous emission and transmission measurements as an adjunct to dynamic planar gamma camera studies.

Anatomical imaging provides useful information which complements functional imaging performed using a gamma camera. We have previously used transmission measurements in single-photon emission tomography acquired simultaneously with the emission scan using either a plane flood source or a moving line source for attenuation and scatter correction. This approach is equally applicable in planar imaging and provides useful information to assist in detecting patient motion and in defining regions of interest in dynamic studies. We have adapted a moving transmission line source to acquire dynamic geometric mean measurements in the study of the mucociliary clearance of inhaled technetium-99m labelled colloids with a single-headed rotating gamma camera. The line source makes a return pass for each emission acquisition frame (alternating anterior/posterior views), each pass being initiated by a signal from the gamma camera. The result is a dynamic sequence of emission and transmission measurements obtained from a single acquisition. In this application transmission measurements are used to define the lung outline for clearance determination and to check for subject movement throughout the duration of the study.

Gamma Cameras↗

Transmission-based scatter correction of 180 degrees myocardial single-photon emission tomographic studies.

Meaningful comparison of single-photon emission tomographic (SPET) reconstructions for data acquired over 180 degrees or 360 degrees can only be performed if both attenuation and scatter correction are applied. Convolution subtraction has appeal as a practical method for scatter correction; however, it is limited to data acquired over 360 degrees. A new algorithm is proposed which can be applied equally well to data acquired over 180 degrees or 360 degrees. The method involves estimating scatter based on knowledge of reconstructed transmission data in combination with a reconstructed estimate of the activity distribution, obtained using attenuation correction with broad beam attenuation coefficients. Processing is implemented for planes of activity parallel to the projection images for which a simplified model for the scatter distribution may be applied, based on the measured attenuation. The appropriate broad beam (effective) attenuation coefficients were determined by considering the scatter buildup equation. It was demonstrated that narrow beam attenuation coefficients should be scaled by 0.75 and 0.65 to provide broad beam attenuation coefficients for technetium-99m and thallium-201 respectively. Using a thorax phantom, quantitative accuracy of the new algorithm was compared with conventional transmission-based convolution subtraction (TDCS) for 360 degrees data. Similar heart to lung contrasts were achieved and correction of 180 degrees data yielded a 10.4% error for cardiac activity compared to 5.2% for TDCS. Contrast for myocardium to ventricular cavity was similarly good for scatter-corrected 180 degrees and 360 degrees data, in contrast to attenuation-corrected data, where contrast was significantly reduced. The new algorithm provides a practical method for correction of scatter applicable to 180 degrees myocardial SPET.

Algorithms↗

Validation of postinjection transmission measurements for attenuation correction in neurological FDG-PET studies.

UNLABELLED: Accurate estimation of local cerebral metabolic rate of glucose utilization (LCMRGlu) with PET requires a separate measurement of photon attenuation using a transmission source that extends study duration. The feasibility of postinjection transmission, (PIT) scanning has been demonstrated but not previously validated in humans. METHODS: Preinjection and postinjection transmission scans were performed in 26 patients undergoing routine [18F]fluorodeoxyglucose (FDG) neurological PET. The PIT data were processed with two methods: One estimated emission contamination using an independent emission scan (PITind); the other estimated the contamination directly from the PIT scan, using simultaneously acquired emission data for subtraction (PITsim). These methods were compared with measured attenuation correction (AC) using preinjection transmission data (ACpre) and calculated AC (ACcalc). After reconstruction, image data were reformatted to fit a standard brain atlas to facilitate analysis of the region of interest and to allow subtraction of datasets averaged over all subjects. RESULTS: The ratios of LCMRGlu values with respect to those obtained by the ACpre method ranged from 0.98 to 1.06 (mean +/- s.d., 1.01 +/- 0.02) for PITind, from 0.96 to 1.04 (mean 0.99 +/- 0.02) for PITsim and from 0.77 to 1.12 (mean 0.96 +/- 0.07) for ACcalc. Both PIT methods agreed well with the ACpre method, whereas ACcalc gave rise to appreciable bias in structures near thick bone or sinuses. CONCLUSION: Accurate quantitative estimates of LCMRGlu can be obtained using PIT measurements. The PIT methods shorten study duration and increase patient throughput. The PITsim method has the further advantage that it is not affected by tracer redistribution and can therefore be applied to tracers with relatively rapid kinetics in vivo.

Brain↗

Simultaneous emission and transmission measurements for attenuation correction in whole-body PET.

UNLABELLED: We describe a methodology for measuring and correcting for attenuation in whole-body PET using simultaneous emission and transmission (SET) measurements. METHODS: The main components of the methodology are: (a) sinogram windowing of low activity (< or = 50 MBq) rotating 68Ge/Ga rod sources, (b) segmented attenuation correction (SAC) and (c) maximum likelihood reconstruction using the ordered subsets EM (OS-EM) algorithm. The methods were implemented on a whole-body positron emission tomograph. Quantitative accuracy and the signal-to-noise ratio (SNR) were measured for a thorax-tumor phantom as functions of acquisition time (range: 2-20 min per position). RESULTS: When a typical rod source activity (200 MBq 68Ge/Ga) was used, emission SNR was 60% lower in simultaneous than in separate measurements. The difference was only 14% when the rods contained 45 MBq 68Ge/Ga. The SNR was further improved by SAC in conjunction with OS-EM reconstruction and the relative gain increased with increasing acquisition time. Quantitative estimates of tumor, liver and lung radioactivity agreed with values obtained from a separate high count measurement to within 8%, independent of acquisition time. CONCLUSION: Attenuation correction of whole-body PET images is feasible using SET measurements. There is good quantitative agreement with conventional methods and increased noise is offset by the use of SAC and OS-EM reconstruction.

Adult↗

A transmission-dependent method for scatter correction in SPECT.

UNLABELLED: A method of scatter compensation has been developed that incorporates planar transmission measurements in the estimation of photopeak scatter in SPECT. METHODS: The scatter distribution is first estimated by convolving the planar projections with a monoexponential scatter function. The number of scattered events that subsequently reach the detector as a proportion of total events (i.e., scatter fraction) is then determined for each point in the projections based on narrow-beam transmission values, obtained using an external source. The assumptions of the method were tested using 99mTc and 201Tl point and line sources. The quantitative and qualitative impact of transmission-dependent scatter correction was assessed in realistic phantom experiments simulating blood-pool, lung and myocardial perfusion studies. RESULTS: The method accurately predicts the scatter distribution from 99mTc and 201Tl line sources in a phantom with variable density. Reconstructed counts are artificially enhanced in regions of high tissue density when scattered events are not removed from the projections prior to attenuation correction. Using convolution-subtraction with a constant scatter fraction (k = 0.4), scatter is underestimated in the heart and overestimated in the lungs, whereas transmission-dependent scatter correction enables activity to be quantified with > or = 95% accuracy in heart and lung regions. CONCLUSION: We conclude that incorporating transmission data enables accurate scatter compensation in objects with nonuniform density.

Female↗

A scanning line source for simultaneous emission and transmission measurements in SPECT.

A scanning collimated line source for simultaneously acquiring emission and transmission data from a gamma camera has been developed. The line source is microprocessor-controlled and incorporates hardware to electronically window the spatial gamma camera signals in order to separate the emission signals of the subject from transmission signals from the line source. The device improves upon the previously described emission-transmission scanning technique using a flood source in three ways: (1) it overcomes the limitation that the transmission radionuclide must have a lower energy than the emission radionuclide; (2) it provides narrow-beam (scatter free) attenuation measurements of the subject being examined; and (3) it reduces the radiation exposure to staff. Attenuation coefficients for an elliptocal water-filled phantom were measured to be mu = 0.15 +/- 0.01 cm-1. The technique has been validated in phantom and human studies using a range of radionuclide combinations and imaging geometries and gives equivalent results using separate and simultaneous acquisitions.

Female↗

Attenuation correction using count-limited transmission data in positron emission tomography.

Poisson noise in transmission data can have a significant influence on the statistical uncertainty of PET measurements, particularly at low transmission count rates. In this paper, we investigate the effect of transmission data processing on noise and quantitative accuracy of reconstructed PET images. Differences in spatial resolution between emission and transmission measurements due to transmission data smoothing are shown to have a significant influence on quantitative accuracy and can lead to artifacts in the reconstructed image. In addition, the noise suppression of this technique is insufficient to greatly reduce transmission scan times. Based on these findings, improved strategies for processing count-limited transmission data have been developed, including a method using segmentation of attenuation images. Using this method, accurate attenuation correction can be performed using transmission scan times as low as 2 min without increasing noise in reconstructed PET images.

Heart↗

Correction and characterization of scattered events in three-dimensional PET using scanners with retractable septa.

Large sensitivity increases are realized in positron emission tomography when the interplane septa are removed and all lines of response acquired. Unfortunately, three-dimensional acquisition results in a large increase in scatter fraction which prevents accurate quantitation. By acquiring short two-dimensional scans prior to three-dimensional ones, scatter distributions can be estimated from differences between lines of response common to both datasets. This initial scatter distribution can be further modified to approximate scatter in the entire three-dimensional dataset. The method was validated with phantom measurements in which absolute activity concentrations were known in all compartments. Following scatter correction, a four-compartment phantom that was nonuniform in activity and density, both axially and transaxially, gave activity concentrations of 0.45 +/- 0.02, 0.31 +/- 0.02, 0.01 +/- 0.01 and 0.01 +/- 0.01 microCi/cc for compartments containing 0.43, 0.29, 0.0 (air) and 0.0 (water) microCi/cc, respectively. Thus, scatter distributions for complex sources can be estimated from image data without lengthy Monte-Carlo simulations. When activity distributions vary slowly with time, this method can be used to correct for scatter in three-dimensional patient studies.

Brain↗