Search PubMedSearch

Biomedical subjects

S R Cunningham

Publications and source records attributed to S R Cunningham.

11 recordsLinked to original sources

Electrode pad size, transthoracic impedance and success of external ventricular defibrillation.

Electrode pad size is an important determinant of transthoracic current flow during external countershock. Self-adhesive, dual function electrocardiogram/defibrillator pads were used to assess the effect of electrode pad size on defibrillation success with low energy (200 J) shocks. The study analyzed 123 cardiac arrests due to primary ventricular fibrillation (VF) in 105 patients (74 men, 31 women) ages 40 to 84 years (mean 64). Transthoracic impedance was measured before defibrillation using a low amplitude 30-kHz current passed through the chest by way of the electrocardiogram/defibrillator pads applied anteroanteriorly. Pad diameters were small (8/8 cm) in 26 cardiac arrests, intermediate (8/12 cm) in 63 arrests and large (12/12 cm) in 34 cardiac arrests. Transthoracic impedance decreased with increasing pad size (112 +/- 17 vs 92 +/- 22 vs 72 +/- 14 omega, respectively, p = 0.0001). Only the first episode of primary VF during a cardiac arrest was analyzed. A single shock of 200 J (delivered energy) was successful in 8 of 26 (31%) arrests using small pads, in 40 of 63 (63%) with intermediate pads and in 28 of 34 (82%) with large pads (p = 0.0003). A second 200-J shock increased the cumulative defibrillation rates to 12 of 26 (46%), 50 of 63 (79%) and 33 of 34 (97%), respectively (p less than 0.0001). In primary VF, larger self-adhesive electrocardiogram/defibrillator pads are associated with a lower transthoracic impedance and improved defibrillation success rates with low energy shocks.

Adhesives

A double blind placebo controlled study of early and late administration of recombinant tissue plasminogen activator in acute myocardial infarction.

Within four hours of the onset of acute myocardial infarction 57 consecutive patients were randomised blindly to infusion of 150 mg recombinant tissue plasminogen activator (rt-PA) (group 1) over five hours or placebo (group 2) when they were first seen outside hospital or in the accident and emergency department. When they were admitted to the coronary care unit patients in group 1 also had placebo infused and those in group 2 were treated with rt-PA as well as placebo. Treatment with rt-PA started at a mean of 119 minutes (range 38-235) after the onset of pain in group 1 and 187 minutes (range 80-285) after the onset of pain in group. In 19 (79%) of 24 in group 1 and 16 of 25 (64%) in group 2 cardiac catheterisation 10-14 days after infarction showed thrombolysis in myocardial infarction grades 2 or 3. There was mean percentage shortening of the infarct related segments (Leighton method) of 16% in group 1 and 10.3% in group 2. For patients with anterior infarction mean percentage shortening was 20.5% in group 1 and 12.2% in group 2. Although there was no significant difference in global ejection fraction as assessed by contrast ventriculography or radionuclide ventriculography the infarct related regional third ejection fraction (a measure of the function of the territory of the affected coronary artery) was significantly improved by early treatment (41% group 1 and 28% group 2). Assessment of infarct size by the QRS scoring method of Palmeri showed QRS score less than or equal to 15/25 patients in group 1 and 8/27 in group 2. Nine patients developed 11 episodes of ventricular fibrillation; all patients in whom ventricular fibrillation developed during treatment with rt-PA were successfully resuscitated. There was no clinically significant bleeding. In seven (12%) patients clinical and electrocardiographic criteria suggested reocclusion. Five patients died from cardiac causes. Prehospital administration of rt-PA was feasible and significantly reduced the delay before thrombolysis was started. Earlier treatment improved myocardial function in the the infarct area and reduced the infarct size.

Adult

Initial experience with a microprocessor controlled current based defibrillator.

Intramyocardial current flow is a critical factor in successful ventricular defibrillation. The main determinants of intramyocardial current flow during transthoracic countershock are the selected energy and the transthoracic impedance of the patient. To optimise the success of the first shock and to titrate energy dosage according to each patient's transthoracic impedance, a microprocessor controlled current based defibrillator was developed. It was compared with a conventional energy based protocol of 200 J (delivered energy), 200 J, then 360 J if required in 42 consecutive episodes of ventricular fibrillation in 33 men and seven women. The mean (SD) predicted transthoracic impedance was 69.9 (14.0) omega. First shock success with the standard protocol was 80.9%, and first or second shock success was 95.2%. The microprocessor controlled current based defibrillator automatically measured transthoracic impedance and calculated the energy required to develop a selected current in each patient. A current protocol of 30 A, 30 A, then 40 A, if required, was used in 29 men and 12 women with 41 episodes of ventricular fibrillation. Transthoracic impedance (mean 65.1 (15.9) omega) was similar to that in the energy protocol group and success rates for first shock (82.9%) and first or second shocks (97.5%) were also similar. The mean delivered energy per shock with the current based defibrillator for first or second shock success was significantly less (144.8 J) with the energy protocol (200 J). The mean peak current of successful shocks was also significantly reduced (29.0 v 31.9 A). A current based defibrillator titrates energy according to transthoracic impedance; it has a success rate comparable to conventional defibrillators but it delivers significantly less energy and current per shock.

Cardiography, Impedance

A randomised dose ranging study of recombinant tissue plasminogen activator in acute myocardial infarction.

To assess the thrombolytic efficacy and the effect on the systemic fibrinolytic system of recombinant tissue plasminogen activator doses of 20 mg, 50 mg, and 100 mg were compared in a randomised study. Tissue plasminogen activator was infused intravenously over 90 minutes in 50 consecutive patients with acute myocardial infarction of four hours' duration or less; on average the infusion was started 135 minutes (range 20 to 240) after the onset of pain. The affected artery was patent at the end of the 90 minute infusion in 14/17 (82%) of those who received 100 mg, 12/17 (71%) of those who received 50 mg, and 8/16 (50%) of those who received 20 mg. Regardless of dose, reperfusion rates were significantly better for patients treated within two hours of the onset of symptoms (81%) than for those treated in the third and fourth hours (54%). At the end of the infusion serum fibrinogen concentrations fell to 86% of the preinfusion value after 20 mg, 75% after 50 mg, and 63% after 100 mg, and similar dose dependent changes occurred in plasminogen, (alpha 2 anti-plasmin, and fibrinogen and fibrin degradation products. The mean infarct related regional third ejection fraction was 46% for patients with grade 2 or 3 reperfusion and 35% for those with grade 0 or 1. Ventricular fibrillation occurred in six (12%) patients during the infusion of tissue plasminogen activator, but no late ventricular fibrillation occurred. Bleeding was minimal, reocclusion occurred in three patients, and four patients died from cardiac causes. Recombinant tissue plasminogen activator is an effective thrombolytic agent which produces better reperfusion rates after a 50 or 100 mg dose than after a 20 mg dose. The effect on the systemic fibrinolytic system is dose dependent. Successful reperfusion results in improvement of left ventricular function.

Adult

Assessment of a device for trans-telephonic control of defibrillation.

The safety and efficacy of a device allowing the trans-telephonic control of defibrillation have been assessed in 32 attempted defibrillations performed in 29 patients. The initial rhythm was atrial fibrillation in 27; ventricular tachycardia in 4; and ventricular flutter in 1. Satisfactory voice and ECG transmission were established in all cases. The mean time taken by the patient unit to dial and activate the base station was 20.3 seconds. The mean defibrillator charge time was 5.5 seconds to 50 joules and 9.3 seconds to 360 joules. A total of 84 synchronised and 5 unsynchronised shocks were delivered satisfactorily. Lay persons were trained to use the patient unit, and were able to operate the device at home. This device has the potential for rapid defibrillation of patients who develop ventricular fibrillation outside hospital.

Adult

Acute left ventricular failure caused by acute on chronic alcohol consumption.

We present a case of acute left ventricular failure following acute on chronic alcohol consumption. Left ventricular ejection fraction, which was 26% on admission, returned to normal on discharge. Atrial fibrillation, a marked reduction in left ventricular ejection fraction and increase in left ventricular wall thickness were attributable to acute on chronic alcohol consumption. Left-sided hemiplegia was associated with recurrence of atrial fibrillation.

Alcoholism

Kyrle's disease.

Kyrle's disease is a chronic, genetically determined, hyperkeratotic disorder occurring in the middle forties. We report fourteen cases of this disorder in a population of 1.5 million over a period of 15 years. We observed a female/male ratio of 6:1. Straw-colored keratotic plugs and flat scale show a marked predisposition for the calf, the tibial region, and the posterior part of the thigh. They vary in size from 1 to 4 mm, and there is occasional plaque formation. No koebnerization or pruritus was noted, and no statistically significant association with hepatic, renal, or diabetic disorders could be demonstrated. Microscopic features showed a consistent pattern of keratotic plug formation, with the plug sitting in an invaginated atrophic epidermis, and underlying dermal histiocyte and lymphocyte aggregation. All lesions contained orthokeratosis and parakeratosis, with some sections showing abnormal keratinization. Sodium dodecylsulfate gel electrophoresis did not demonstrate the presence of abnormal keratin bands.

Adult