Search PubMed⌕ Search

Biomedical subjects

S Posse

Publications and source records attributed to S Posse.

50 records · Page 3Linked to original sources

Anomalous transverse relaxation in 1H spectroscopy in human brain at 4 Tesla.

Longitudinal (T1) and apparent transverse relaxation times (T2) of choline-containing compounds (Cho), creatine/phosphocreatine (Cr/PCr), and N-acetyl aspartate (NAA) were measured in vivo in human brain at 4 Tesla. Measurements were performed using a water suppressed stimulated echo pulse sequence with complete outside volume presaturation to improve volume localization at short echo times. T1-values of Cho (1.2 +/- 0.1 s), Cr (1.6 +/- 0.3 s), and NAA (1.6 +/- 0.2 s) at 4 Tesla in occipital brain were only slightly larger than those reported in the literature at 1.5 Tesla. Thus, TR will not adversely affect the expected enhancement of signal-to-noise at 4 Tesla. Surprisingly, apparent T2-values of Cho (142 +/- 34 ms), Cr (140 +/- 13 ms), and NAA (185 +/- 24 ms) at 4 Tesla were significantly smaller than those at 1.5 Tesla and further decreased when increasing the mixing interval TM. Potential contributing factors, such as diffusion in local susceptibility related gradients, dipolar relaxation due to intracellular paramagnetic substances and motion effects are discussed. The results suggest that short echo time spectroscopy is advantageous to maintain signal to noise at 4 Tesla.

Artifacts↗

Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain.

PURPOSE: To demonstrate the feasibility of three-dimensional echo-planar spectroscopic imaging (EPSI) at short echo time (13 msec) with a conventional clinical imager in the human brain. MATERIALS AND METHODS: Periodic inversions of a readout gradient were used during data acquisition to simultaneously encode chemical shift and one spatial dimension in one excitation. Aliasing artifacts were avoided with a modified acquisition-and-processing method based on oversampling. A double outer-volume suppression technique that adapts to the ovoid brain shape was used to strongly reduce extracranial lipid resonances. RESULTS: Three-dimensional spatial encoding in vivo of eight sections with 32 x 32 voxels each (0.75 cm3) was performed in 34 minutes with four signal averages. The spectral resolution and signal-to-noise ratio (S/N) of resonances of inositol, choline, creatine, glutamate and glutamine, and N-acetyl aspartate were consistent with those previously recorded with conventional phase encoding. CONCLUSION: EPSI substantially reduces acquisition time for three-dimensional spatial encoding and yields a spectral quality similar to that obtained with conventional techniques without affecting the S/N per unit time and unit volume.

Aspartic Acid↗

Human brain: proton diffusion MR spectroscopy.

Diffusion of brain metabolites was measured in 10 healthy volunteers by using localized proton diffusion magnetic resonance (MR) spectroscopy. Measurements were conducted with a clinical MR imager by using a stimulated-echo pulse sequence (3,000/60 [repetition time msec/echo time msec], 200-msec mixing time) with additional outside-volume suppression. Motion artifacts due to macroscopic brain movements were compensated by means of peripheral cardiac gating and separate collection of individual spectroscopic acquisitions into a two-dimensional data matrix. Phase errors due to macroscopic motion were subsequently corrected in individual data traces prior to spectral averaging. Mean (+/- 1 standard deviation) apparent diffusion coefficients of choline-containing compounds ([0.13 +/- 0.03] x 10(-3) mm2/sec), creatine and phosphocreatine ([0.15 +/- 0.03] x 10(-3) mm2/sec), and N-acetyl aspartate ([0.18 +/- 0.02] x 10(-3) mm2/sec) were substantially smaller than that of water and were consistent with recently published data obtained in anesthetized and paralyzed animals. Adequate diffusion sensitivity for metabolites in the human brain can be obtained with clinical whole-body imagers despite macroscopic head and brain movements.

Adult↗

Direct imaging of magnetic field gradients by group spin-echo selection.

A new image processing method for single-echo gradient echo imaging is presented which extracts local phase gradient information by k-space filtering instead of by phased reconstruction and spatial differentiation. It is shown that local phase gradient directions and semiquantitative local phase gradient magnitudes can be directly measured, even in regions where phased image reconstruction suffers from multiple phase foldovers due to strong phase modulations. The directional information thus obtained can be used as a reference to identify and correct phase modulation foldovers in phase maps which may be computed from the same raw data. The method is applied here to measure static magnetic field gradients and illustrates fundamental k-space signal properties of gradient echo imaging. Based on this concept, image artifacts caused by conventional strong k-space filtering in gradient echo imaging are discussed.

Artifacts↗

Neuro-Behçet: acute and sequential aspects by MRI and MRS.

Three patients with neuro-Behçet underwent MRI and MRS during acute illness. After therapy, MRI and MRS were performed in 3 and 1 patients, respectively. MRI revealed a marked improvement of the initial lesion in 2, a complete remission in 1 patient. MRS showed a reduction of the N-acetyl-aspartate (NAA)/phosphocreatine (CR) ratio within the acute lesion in all patients and a normalization in the follow-up spectrum of the examined patient.

Adrenal Cortex Hormones↗

Magnetic resonance in preterm and term newborns: 1H-spectroscopy in developing human brain.

Localized proton magnetic resonance spectra were recorded from human cerebellum in vivo with a 1.5-T magnet. The spectra from healthy adults and preterm and term babies showed resonances from N-acetylaspartate, creatine and phosphocreatine, choline-containing compounds such as phosphocholine and glycerophosphocholine, taurine, and inositol. The age-dependent changes of in vivo molar concentrations of N-acetylaspartate, choline, taurine, and inositol were estimated in preterm babies, babies at term, and adults. The range of postconceptional age in the studied babies was 31 to 45 wk. Taking the biochemically measured creatine concentrations in age-corresponding autopsy material as an internal standard, the in vivo concentrations of the other metabolites were calculated from the proton spectra. N-acetylaspartate showed an increase from 1.9 mM in preterm babies to 3.1 mM in term babies and to 6.5 mM in adult brain. Taurine was noted to increase from 1.1 mM in preterm infants to 2.3 mM in term infants and did not decrease significantly in adult brain. Choline and inositol concentrations did not change significantly throughout the studied age groups. These new data on in vivo, localized 1H-spectroscopy show that it is a sensitive method for studying early metabolic brain development in humans.

Adult↗

Brain development: 1H magnetic resonance spectroscopy of rat brain extracts compared with chromatographic methods.

We compared in vitro 1H magnetic resonance spectroscopy (MRS) measurements of rat brain extracts (rats: 2-56 days old) with chromatographic measurements and in a further step also with results of in vitro MRS. The following substances can be reliably measured in brain extracts by in vitro MRS: N-acetylaspartate (NAA), total creatine (Cr), phosphorylethanoloamine (PE), taurine (Tau), glutamate (Glu), glutamine (Gln), gamma-aminobutyrate (GABA) and alanine (Ala). Two different methods of MRS data evaluation compared with chromatographic data on Cr and NAA are shown. During development of the rat from day 2-56 brain concentrations of PE, Tau and Ala decrease, those of NAA, Cr, Glu and Gln increase, while GABA does not change. The developmental patterns of these substances are the same, whether measured by in vitro MRS or by chromatographic methods. Quantification of NAA, Cr, Tau, GABA and PE leads to the same results with both methods, while Glu, Gln and Ala concentrations determined by in vitro MRS are apparently lower than those measured chemically. The NAA/Cr ratios of 7 to 35-day-old rats were determined by in vivo 1H MRS. These results correlate with chromatographic and in vitro data. Using appropriate methods in the in vivo and in vitro MR-technique, the obtained data compare well with the chromatographic results.

Aging↗

Brain damage and recovery in hyperphenylalaninemic rats.

Rats were made hyperphenylalaninemic by injecting a mixture of alpha-methylphenylalanine and phenylalanine. Brain development was measured by biochemical, histological and 31-P nuclear magnetic resonance (NMR) methods. In 17-day-old hyperphenylalaninemic rats, brain myelinogenesis was disturbed. Compared to controls, test animals had lower body weights, brain weights, cerebrosides, sulfatides, myelin basic protein (MBP) and reduced cerebroside sulfotransferase (CST) and 2'3'-cyclic nucleotide-3'-phosphohydrolase (CNP) activities. No changes were found in total proteins, total lipids, total phospholipids, phosphatidylethanolamine and phosphorylethanolamine. In the brain of 17-day-old hyperphenylalaninemic rats no changes in phosphomonoesters, phosphodiester and phosphocreatine were found using in vivo 31-P NMR spectroscopy. Because body weights of hyperphenylalaninemic rats were significantly lower than those of controls, we compared them with undernourished rats. Undernourished rats had lower body weights, brain weights and CNP activity. No other changes were found. Therefore, we conclude that hyperphenylalaninemia per se and not undernutrition affected myelinogenesis in test animals. After treatment was discontinued, test rats recovered completely within 6 weeks with regard to biochemical and histological measurements; at 59 days they had normal body weights, cerebrosides, sulfatides, MBP, total proteins, total lipids, total phospholipids, phosphatidylethanolamine, phosphorylethanolamine and normal CST and CNP activities. Brain weights were significantly reduced.

2',3'-Cyclic-Nucleotide Phosphodiesterases↗

Study of acute renal ischemia in the rat using magnetic resonance imaging and spectroscopy.

Magnetic resonance (MR) imaging and spectroscopy, chemical lactate measurements, and microscopic examinations were performed to investigate acute renal ischemia in rats. MR images (1H) and spectra (31P and 1H) were acquired on a 2.0-T superconducting small-bore magnet by using implanted coils. Occlusion of the renal artery induced a significant decrease in signal intensity of the renal parenchyma on T2-weighted images, which was most obvious in the outer medulla (-50 +/- 15%, n = 8, P less than 0.001) and was the result of venous congestion, as verified histologically, 31P spectroscopy demonstrated a drop in pH from 7.3 +/- 0.2 to 6.6 +/- 0.2 (n = 18, P less than 0.001), characterized by a time constant (Tc) in the same range as that of the depletion of ATP (2.3 +/- 1.3 min versus 1.9 +/- 1.2 min, n = 10, P = ns). By means of 1H spectroscopy, a lactate peak was detected within 1.5 to 4 min of ischemia, still increasing in intensity after 1 h of ischemia. The Tc of the lactate buildup (15.9 +/- 7.5 min, n = 8) was significantly longer than that of the drop in pH (P less than 0.005). The chemically measured intrarenal concentration of lactate was 1.3 +/- 0.5 mumol/g in control kidneys and 8.7 +/- 3.2 mumol/g (P less than 0.005) in kidneys made ischemic for 1 h. The present study demonstrated important features of acute renal ischemia: (a) acute ischemia induces venous congestion in the medulla; (b) accumulation of lactate is not the main cause of the intracellular acidification observed during ischemia.

Animals↗

1H spectroscopic imaging at high spatial resolution.

Spectroscopic imaging and single voxel localization are compared with respect to the signal to noise ratio per unit time and unit volume. It is shown experimentally that, when using the same experiment time and the same voxel size, both methods give similar results. In order to investigate the localization limits of spectroscopic imaging, lipid distribution in a single large cell was measured and correlated with gradient echo microscopy.

Animals↗

Short echo time proton MR spectroscopic imaging.

Proton spectroscopic imaging at short TEs (20-30 ms) in human brain requires volume preselection inside the brain to suppress overwhelming lipid and water signals from surrounding tissue. In this article we discuss limitations of conventional volume preselection using stimulated echoes that lead to spectral contamination from surrounding tissue. Improved volume preselection was obtained by adding a complete outer volume suppression (presaturation). The performance of the method is illustrated on normal volunteers and on clinical cases with brain tumors and multiple sclerosis (MS) plaques. In normal human brain, we detected resonances with short T2 values and complex J-coupling, including rather broad methyl/methylene resonances in the chemical shift range between 0 and 2 ppm. Spectroscopic images obtained on patients with intracranial tumors and on one patient with several MS plaques demonstrate the possibility of detecting regional distributions of increased methyl/methylene resonances between 0 and 2 ppm in brain lesions.

Adult↗

Absolute quantitation of short TE brain 1H-MR spectra and spectroscopic imaging data.

A method for determining the concentrations of the materials that produce the well-resolved singlet signals in short TE brain 1H MR spectroscopic examinations is presented. Concentration determination is achieved by a water-referencing procedure. The ratios of the areas of the choline, total creatine, and N-acetyl signals to that of the water signal from the same volume of interest (VOI) are determined using acquisitions with and without water suppression. The tissue concentrations of the molecules producing the three signals can then be determined if the water concentration in the VOI can be found. This is done with a density-weighted MR study. The MR study provides the ratio of the mean MR signal amplitude from the VOI to that from an external standard containing a known water concentration. The method's flexibility is illustrated by using it with two different single-volume localization schemes and spectroscopic imaging. Preliminary evaluations of accuracy and reproducibility are made in phantom, animal, and limited human studies. The method's advantages and limitations are discussed.

Acetylation↗

Cerebral N-acetylaspartate is low in patients with multiple sclerosis and abnormal visual evoked potentials.

PURPOSE: Our purpose was to compare cerebral proton MR metabolite changes in patients with multiple sclerosis (MS) and abnormal visual evoked potentials (VEPs) with those in MS patients with normal VEPs. METHODS: Seventeen subjects with clinically definite MS were studied with VEPs and MR spectroscopic imaging. Proton MR metabolites were measured using a fast spectroscopic imaging technique called proton echo-planar spectroscopic imaging (PEPSI). Kurtzke's Expanded Disability Status Scale (EDSS) score was also ascertained for each subject to obtain a clinical rating. Twelve regions of interest within the visual pathway of the cerebrum were evaluated for levels of N-acetylaspartate (NAA), choline, creatine, and the presence or absence of MR-detectable lesions. RESULTS: PEPSI NAA values (water-normalized, CSF-corrected) were significantly lower in MS subjects with abnormal VEPs than in subjects with normal VEPs. MR-detectable lesion fractions and EDSS scores were also significantly different between the two VEP groups, but NAA comparison had a P value 100 times less than either of these measures. CONCLUSION: In patients with MS, NAA measurements in the optic pathways of the brain were sensitive to VEP abnormalities. NAA was more sensitive to VEP changes than were choline, creatine, MR-detectable lesions, and EDSS score.

Adult↗