Search PubMed⌕ Search

Biomedical subjects

S Oie

Publications and source records attributed to S Oie.

At least 37 records · Page 2Linked to original sources

Survival of methicillin-resistant Staphylococcus aureus (MRSA) on naturally contaminated dry mops.

The floors of single rooms being used by inpatients colonized by methicillin-resistant Staphylococcus aureus (MRSA) were cleaned using disposable dust-attracting dry mops. Each mop was divided into 12 sections and MRSA quantified serially. This experiment was repeated a total of 21 times for four patients. The MRSA survival rate on the dry mops compared with a control was 59.0-125% after seven days, 26.3-41.6% after 14 days, 0.1-16.2% after 28 days, 0-0.1% after 56 days and 0% after 84 days. MRSA disseminated by patients over the environment can survive for several weeks on dry mops.

Colony Count, Microbial↗

Microbial contamination of antiseptics and disinfectants.

BACKGROUND: There have been a number of reports on microbial contamination of antiseptics and disinfectants. At present, however, the necessity of measures to prevent contamination do not seem to be fully appreciated. We investigated microbial contamination of antiseptics and disinfectants that are used in our hospital. METHODS: Fifty-one samples of benzalkonium chloride and chlorhexidine gluconate that were being used in the hospital were examined. Viability of the contaminants detected in these samples was also tested in the agents. Then we examined measures to prevent contamination of these agents. RESULTS: Microbial contamination was detected at 10(2) to 10(7) CFU/ml in the following samples: 6 of 23 samples of cotton balls soaked in 0.02% benzalkonium chloride kept in a canister for antisepsis and disinfection (26.1%); 7 of 13 samples of 0.02%, benzalkonium chloride or 0.02% chlorhexidine gluconate in an irrigation apparatus kept at 37 degrees C for vaginal douching (53.8%); and 9 of 15 samples of 0.02% benzalkonium chloride or 0.05% chlorhexidine gluconate for storage of suction catheters in a plastic bottle (60%). The major contaminants were Burkholderia cepacia, Pseudomonas aeruginosa, Xanthomonas maltophilia, and Pseudomonas fluorescens. The first two organisms examined grew in the agents. After improvements in the handling of the antiseptics and disinfectants, no microbial contamination was observed. CONCLUSIONS: It is necessary to check microbial contamination of diluted benzalkonium chloride and diluted chlorhexidine gluconate that are in use. Such products are not recommended as antiseptics.

Anti-Infective Agents, Local↗

Efficacy of disinfectants against biofilm cells of methicillin-resistant Staphylococcus aureus.

The effect of disinfectants on biofilm cells of methicillin-resistant Staphylococcus aureus (MRSA) was evaluated. Eradication of biofilm cells of MRSA by chlorhexidine gluconate, benzalkonium chloride, alkyldiaminoethyl glycine and sodium hypochlorite required a much longer time than that of planktonic cells in suspensions. Benzalkonium chloride (0.1%) and alkyldiaminoethyl glycine (0.1%) were ineffective for eradication of biofilm cells even after 1 h, but were effective for eradication of planktonic cells within 20 s. Sodium hypochlorite (0.01%) was also ineffective for eradication of biofilm cells even after 30 min, but was lethal to planktonic cells within 20 s.

Biofilms↗

[Prevention of MRSA spread in the neurosurgical field].

We investigated the distribution of MRSA (methicillin-resistant Staphylococcus aureus) on and around six patients with MRSA infection in our neurosurgical ward. All patients had a disturbance of consciousness and had sputum colonization of MRSA. Samples were obtained from 11 sites (patients' hands, attendances' hands, floors, sidetables, bedclothes, chairs, walls, curtains, door knobs, faucets and disposable gloves) in the patients' rooms by the wiping method. High counts of MRSA were detected on horizontal planes such as floors, sidetables and chairs, but MRSA was not detected on vertical planes such as curtains and walls. The reason why MRSA was detected on the horizontal planes was due to a fall of MRSA spread from sputum in the air. These findings indicate that the disinfection of horizontal planes is important for preventing the spread of MRSA. We also evaluated what disinfectant was useful for floor disinfection and concluded that 0.5% chlorhexidine digluconate (Hibitane) and 0.5% benzalkonium chloride (Osvan) were more effective than the other usually-used disinfectants such as alkyldiaminoethyl glycine (Tego-51).

Adult↗

Bacterial contamination of aerosol solutions containing antibiotics.

In an investigation of microbial contamination of aerosol solutions containing antibiotics (hospital pharmaceutical preparations, no preservatives added), five of six residual solutions after multiple use for 7 days were contaminated at a concentration of 10(6) viable counts/ml. Contaminants were glucose-nonfermenting Gram-negative bacilli such as Pseudomonas cepacia and Flavobacterium meningosepticum. The major contaminant, P. cepacia, multiplied rapidly in the aerosol solution under simulated actual-use conditions. The contamination seemed to have been caused by storage, at room temperature instead of in a refrigerator, of the multiple-dose solutions and by frequent re-use of syringes to measure the solutions. Prompt refrigerator storage after each use of the solutions and abandonment of the syringes within 24 h eliminated bacterial contamination of the solutions. Sufficient attention is not paid to prevent bacterial contamination of aerosol solutions containing antibiotics because of the fact that they contain antibiotics. Thus aerosol solutions containing antibiotics should be handled with great care to prevent bacterial contamination.

Aerosols↗

Comparative effectiveness of hand-cleansing agents for removing methicillin-resistant Staphylococcus aureus from experimentally contaminated fingertips.

BACKGROUND: Five subjects participated in a study of optimal conditions for removing methicillin-resistant Staphylococcus aureus from contaminated fingertips. METHODS: Fingertips were contaminated experimentally and cleaned by various methods. Bacterial removal was measured as percentage and is given as mean +/- standard error of the mean. RESULTS: Rinsing the fingertips with tap water for 20 seconds and drying them with paper towels removed 95.2% +/- 1.6% of the contamination. Application of hand-cleansing agents to fingertips for 20 seconds, followed by a 20-second tap-water rinse and towel drying, removed bacteria as follows: povidone-iodine detergent, 99.2% +/- 0.4%; chlorhexidine detergent, 97.2% +/- 0.8%; and liquid soap, 96.1% +/- 1.1%. In a modification of the method, 80% ethyl alcohol applied to the fingertips for 20 seconds, followed by air drying for 40 seconds, removed 99.1% +/- 0.8% of the bacteria. Statistical analyses indicated that povidone-iodine and 80% ethyl alcohol were more effective than the other agents. CONCLUSIONS: Rinsing contaminated fingertips with tap water and towel drying them is sufficient to reduce contamination with methicillin-resistant S. aureus by 95%. Washing with povidone-iodine or 80% ethyl alcohol further reduces contamination by an additional 99%.

Adult↗

Pharmacokinetic-pharmacodynamic (PK-PD) modelling in non-steady-state studies and arterio-venous drug concentration differences.

In conducting a non-steady-state pharmacokinetic (PK)-pharmacodynamic (PD) study there is potential for the observed effect (E) vs time, and venous plasma drug concentration (C) vs time, profiles to display temporal displacement with respect to each other. This is most frequently observed when there exists a distributional nonequilibrium across the effect organ giving rise to hysteresis, i.e. observed C preceding E in the time domain, with the resulting potential for a counterclockwise loop to be generated in the observed E vs C plot (when data are connected in time-order). Such temporal displacement does not afford direct prediction of the steady-state E vs C PD relationship. When an arterio-venous (A-V) difference exists across the tissues of the blood sampling compartment (i.e. the arm), and this arises solely from an elimination process then drug concentration in the respective peripheral arterial plasma and venous plasma compartments will be in equilibrium at all times during a non-steady-state PK experiment. If there are no other sources of temporal displacement in the relationship between E and C then the observed E vs C plot will be a direct predictor of the steady-state E vs C PD relationship. In contrast when the A-V difference is of a distributional nature then proteresis, i.e. observed E preceding C in the time domain, will arise with the potential for the generation of a clockwise loop in the observed E vs C relationship. Simulated error-incorporated E vs time, and C vs time, data was analysed by semi-parametric implementation of an effect-compartment link-model that affords accurate steady-state E vs C PD predictions (without the requirement of sampling arterial blood) from data that incorporates the concurrent presence of: (i) distributional nonequilibrium across the effect organ, and (ii) distributional A-V non-equilibrium. Accurate steady-state E vs C PD predictions were achieved irrespective of the comparative magnitudes of the two nonequilibria, i.e. whether the rate of equilibration across the effect organ was faster than, or slower than, the rate of equilibration across the arm (resulting in a clockwise or counterclockwise loop in the observed E vs C plot, respectively), or indeed if one or other of the nonequilibria is essentially absent. When the rate of equilibration across the effect organ is slower than the rate of A-V equilibration (i.e. counterclockwise loop generated in the observed E vs C plot) then the need to model for the underlying A-V nonequilibrium is redundant, i.e. accurate steady-state E vs C PD predictions can be achieved with implementation (strictly incorrectly) of a more simple link parameterised solely to model for distributional nonequilibrium across the effect organ.(ABSTRACT TRUNCATED AT 400 WORDS)

Computer Simulation↗

Does alpha 1-acid glycoprotein act as a non-functional receptor for alpha 1-adrenergic antagonists?

The ability of a variety of alpha 1-acid glycoproteins (AAG) to affect the intrinsic activity of the alpha 1-adrenergic antagonist prazosin was studied in rabbit aortic strip preparations. From these studies, the activity of AAG appears to be linked to their ability to bind the antagonist. However, a capability to bind prazosin was not the only requirement for this effect. The removal of sialic acid and partial removal of the galactose and mannose residues by periodate oxidation of human AAG all but eliminated the ability of AAG to affect the intrinsic pharmacologic activity of prazosin, although the binding of prazosin was not significantly affected. The presence of bovine AAG, a protein that has a low ability to bind prazosin, reduced the effect of human AAG on prazosin activity. Based upon these results, we propose that AAG is able to bind in the vicinity of the alpha 1-adrenoceptors, therefore extending the binding region for antagonists in such a way as to decrease the ability of the antagonist to interact with the receptor. The carbohydrate side-chains are important for the binding of AAG in the region of the adrenoceptor.

Adrenergic alpha-1 Receptor Antagonists↗

Decreased elimination of drug in the presence of alpha-1-acid glycoprotein is related to a reduced hepatocyte uptake.

The mechanism by which human alpha-1-acid glycoprotein (hAAG) decreases the intrinsic clearance of prazosin was investigated in primary rat hepatocyte cultures. The intrinsic clearance, equal to the ratio of rate of drug elimination to unbound concentration, is the composite result of uptake and metabolism. From separate elimination and uptake studies we found that the ability of hAAG to decrease the intrinsic clearance of prazosin was related to decreased uptake and not to changes in metabolism. In order to identify the underlying mechanism for the observed decrease in uptake the effect of bovine alpha-1-acid glycoprotein (AAG) on prazosin intrinsic clearance and uptake was also determined. Bovine AAG, in contrast to hAAG, had neither a statistical significant effect on prazosin uptake nor on prazosin intrinsic clearance. Based upon the fact that bovine AAG has little or no ability to bind prazosin in contrast to hAAG, we hypothesize that when a AAG, capable of binding prazosin, associated with cell membranes it will retard the diffusion of drug through the cellular stagnant diffusion layer. Human serum albumin (HSA), in contrast to hAAG, did not decrease the uptake of prazosin although HSA binds prazosin and associates with hepatocytes to the same degree as hAAG. However, HSA associated with rat hepatocytes, in contrast to hAAG, appears to have an operationally reduced ability to bind prazosin suggesting that HSA may not be able to retard diffusion of prazosin to the same degree as hAAG. HSA also may release prazosin which subsequently serves to increase the active concentration of prazosin at the cell surface.

Animals↗

Efficacy of disinfectants against biofilm cells of Pseudomonas aeruginosa.

The effect of disinfectants on biofilm cells of Pseudomonas aeruginosa were evaluated. Biofilm cells of P. aeruginosa were eradicated by 0.4 to 0.5% chlorhexidine and 2% glutaral within 1 min, by 0.3% chlorhexidine, 0.5% benzalkonium chloride, 0.1% sodium hypochlorite, and 0.1% titratable I2 providone-iodine within 10 min, and by 0.2% chlorhexidine, 0.1% benzalkonium chloride, and 0.01% sodium hypochlorite within 30 min. However, 0.1% chlorhexidine and 0.1 to 0.5% alkyldiaminoethyl glycine were ineffective for eradication even after 1 h. Eradication of biofilm cells of P. aeruginosa by disinfectants required much longer time than that of planktonic cells in suspensions. The bactericidal effect of disinfectants against biofilm cells was found to be considerably enhanced by increasing the concentrations of the disinfectants.

Disinfectants↗

Microbial contamination of enteral feeding solution and its prevention.

In an investigation of microbial contamination of enteral feeding solutions, all 22 residual solutions obtained immediately after administration were contaminated at concentrations of 10(3) to 10(6) viable counts/ml. Major contaminants were glucose-nonfermenting gram-negative bacilli such as Pseudomonas aeruginosa and Acinetobacter calcoaceticus var anitratus. Contamination seemed to have been caused by frequent reuse of bag-type containers and the infusion tubes connected to the bags, neither of which can be washed or dried. Decontamination methods were evaluated by using polypropylene containers that can be washed and disinfected for administration. Few Serratia marcescens on the inside wall of the container were removed by rinsing with tap water, alone or in combination with detergent scrub. Tap water and detergent plus air-drying at 56 degrees C for 1 hour reduced Serratia marcescens only somewhat. Tap water and detergent plus immersion in 0.01% sodium hypochlorite for 1 hour or in water at 70 degrees C for 3 minutes eliminated all 10(11) cells of Serratia marcescens.

Bacteria↗

Microbial contamination of brushes used for preoperative shaving.

Microbial contamination of brushes used for preoperative shaving was investigated. Of the 24 brushed examined, 18 were contaminated with 10(6)-10(9) colony forming units (cfu) per brush. Non-fermentative Gram-negative bacilli such as Pseudomonas aeruginosa and Xanthomonas maltophilia, and yeast-like fungi such as Candida parapsilosis were the primary contaminants. The mean bacterial count on the skin after the use of contaminated brushes (having a mean bacterial count 2.2 x 10(8) cfu) in 14 subjects was 4.6 x 10(5) cfu 25 cm-2, which was about 100 times (p less than 0.001) the control level. Contaminated brushes could not be disinfected with 80% ethyl alcohol, 0.1% sodium hypochlorite or 0.5% chlorhexidine. These findings suggest that the use of brushes should be avoided for preoperative shaving with a razor, and that sterile gauze and shaving foam should be used instead of a brush and soap.

Candida↗

Microbial contamination of enteral feeding solution and its prevention.

In an investigation of microbial contamination of enteral feeding solutions, all 22 residual solutions obtained immediately after administration were contaminated at concentrations of 10(3) to 10(6) viable counts/ml. Major contaminants were glucose-nonfermenting gram-negative bacilli such as Pseudomonas aeruginosa and Acinetobacter calcoaceticus var anitratus. Contamination seemed to have been caused by frequent reuse of bag-type containers and the infusion tubes connected to the bags, neither of which can be washed or dried. Decontamination methods were evaluated by using polypropylene containers that can be washed and disinfected for administration. Few Serratia marcescens on the inside wall of the container were removed by rinsing with tap water, alone or in combination with detergent scrub. Tap water and detergent plus air-drying at 56 degrees C for 1 hour reduced Serratia marcescens only somewhat. Tap water and detergent plus immersion in 0.01% sodium hypochlorite for 1 hour or in water at 70 degrees C for 3 minutes eliminated all 10(11) cells of Serratia marcescens.

Colony Count, Microbial↗

Pharmacokinetics of moclobemide in male, virgin female, pregnant and nursing rats.

The disposition of moclobemide, a reversible inhibitor of monoamine oxidase isoenzyme A was studied in male, virgin female, pregnant and nursing rats. The average clearance in control rats (male and female) was 36 mL min-1 kg-1, the initial volume of distribution 1.4 L kg-1, the volume of distribution at steady state 2.3 L kg-1 and the terminal half-life 59 min. The blood-to-plasma concentration ratio of moclobemide was 0.84 giving rise to an average blood clearance of 30 mL min-1 kg-1. The clearance values in rats were higher than in man but as a fraction of hepatic blood flow were similar (36 vs 45%). The volume of distribution at steady state was approximately twice as high as in man while the half-life was similar. Pregnant and nursing rats showed no statistically significant differences in their disposition parameters for moclobemide compared with virgin female rats. Nursing rats had statistically significantly lower concentrations of the moclobemide N-oxide metabolite than did pregnant and control rats. Generally lower concentrations of the lactam metabolite were also found in this group although the differences did not reach statistical significance. Moclobemide as well as the N-oxide and lactam metabolites were found in the amniotic fluid suggesting that moclobemide is capable of crossing the placental barrier.

Animals↗

Elimination of non-reactive and weakly reactive human alpha 1-acid glycoprotein after induction of the acute phase response in rats.

The disposition of concanavalin A (Con A)-non-reactive and Con A-reactive human alpha 1-acid glycoprotein (AAG) was studied in normal male rats and in acute phase response-activated male rats. Activation of the acute phase response was made using a subcutaneous administration of ethynyloestradiol in sesame oil. This technique increased the endogenous AAG concentration 7-fold. In control rats the two forms of human AAG showed identical kinetics with an average clearance of 5.4 mL h-1 kg-1, terminal half-life of 13.5 h and a volume of distribution (steady state) of 91 mL kg-1. In the acute phase response-activated animals, both the clearance and volume of distribution were larger: the average clearance of the Con A-non-reactive AAG was 10.2 mL h-1 kg-1, the volume of distribution (steady state) 152 mL kg-1 and the terminal half-life 11.7 h. The Con A-reactive AAG had a clearance of 14.7 mL h-1 kg-1, a volume of distribution (steady state) of 262 mL kg-1 and a half-life of 15.8 h. The results indicate that not only does activation of the acute phase response alter the kinetics of AAG but that the change is different for the different types of AAG.

Acute-Phase Reaction↗

Microbial contamination of ambient air by ultrasonic humidifier and preventive measures.

The microbially contaminated ultrasonic humidifier (UH) causes humidifier fever. The number of airborne viable bacteria was determined when the UH was operating, and other methods to humidify the air of hospital wards were also examined. A UH contaminated with 10(5) bacteria ml(-1), a level common in hospitals, increased the bacterial count in the air from 860 m(-3) to 88,000 m(-3) at a distance of 3 m from the humidifier. Thus UH in hospitals may contaminate the air and be a potential hazard to patients. Contamination was slight when a washable and disinfectable ultrasonic nebulizer was used with disinfection at 24 h intervals. In tracheostomy patients requiring a high degree of air humidification, ultrasonic nebulizers which are readily washed and disinfected are recommended.

Aerosols↗

The effect of alpha 1-acid glycoprotein on the pharmacological activity of alpha 1-adrenergic antagonists in rabbit aortic strips.

The pharmacological activity of three alpha 1-adrenergic antagonists, prazosin, tiodazosin and WB4101 has been studied in the presence and absence of 20 microM alpha 1-acid glycoprotein (AAG) in rabbit aortic strips, and measured as the ability to increase the EC50 value of the alpha 1-adrenergic agonist phenylephrine. For all three drugs, the presence of AAG diminished the pharmacological activity when compared with equivalent unbound concentrations in the absence of AAG. In the presence of AAG the EC50 value of phenylephrine at 5.69 nM unbound prazosin was on average 47% lower than in the absence of AAG (P less than 0.002), at 122 nM unbound tiodazosin, 39% lower (P less than 0.01), and at 25.6 nM unbound WB4101, 68% lower (P less than 0.002). Albumin showed no ability to modify the alpha 1-adrenergic blocking activity of prazosin (P greater than 0.7). The EC50 value for phenylephrine in the absence of antagonists was not affected by AAG. The effect of AAG on the antagonistic activity of prazosin was concentration-dependent with a maximum suppression of prazosin activity of 79% and with a half-maximum concentration of 1.1 microM AAG. AAG significantly decreased prazosin's ability to reduce alpha 1-adrenergic stimulation of calcium influx (P less than 0.05), while it had no effect on prazosin's ability to decrease alpha 1-adrenergic-stimulated formation of inositol phosphate. These results suggest that the effect of AAG on adrenoceptors appears to act selectively via alpha 1 a-receptors. Consistent with these observation was the observation that WB4101, a selective alpha 1a-antagonist was more affected by AAG than was prazosin or tiodazosin.

Adrenergic alpha-Antagonists↗