Search PubMed⌕ Search

Biomedical subjects

S Ohtsubo

Publications and source records attributed to S Ohtsubo.

39 records · Page 3Linked to original sources

Primary structure of limulus anticoagulant anti-lipopolysaccharide factor.

A potent anticoagulant, anti-lipopolysaccharide (LPS) factor, found in limulus hemocytes inhibits the LPS-mediated activation of limulus coagulation cascade and shows an antibacterial action against R-types of Gram-negative bacteria (Morita, T., Ohtsubo, S., Nakamura, T., Tanaka, S., Iwanaga, S., Ohashi, K., and Niwa, M. (1985) J. Biochem. (Tokyo) 97, 1611-1620). The complete amino acid sequence of this substance was determined by sequencing the peptides obtained by selective proteolytic cleavage. The NH2-terminal end of anti-LPS factor was pyroglutamic acid. Anti-LPS factor had two variant residues at position 36 and the COOH-terminal end, respectively. The following sequence was assigned to anti-LPS factor, and it was also confirmed by fast atom bombardment mass spectrometry. less than EGGIWTQLALALVKNLATLWQSGDFQFLGHE (formula; see text) Limulus anti-LPS factor consisted of a single chain of 102 residues with 2 half-cystines in disulfide linkage. Its NH2-terminal region up to 20 residues was highly hydrophobic, and positively charged residues were clustered mainly within the disulfide loop. By searching the homologous sequence in known protein sequences with that of anti-LPS factor, we found a structural homology between anti-LPS factor and alpha-lactalbumin/lysozyme family.

Amino Acid Sequence↗

Isolation and biological activities of limulus anticoagulant (anti-LPS factor) which interacts with lipopolysaccharide (LPS).

Exposure of limulus hemocytes to bacterial endotoxins (lipopolysaccharide, LPS) results in the activation of the intracellular clotting system, consisting of several protein components. During the separation of these components, a potent anticoagulant, named anti-LPS factor, which inhibits the endotoxin-mediated activation of the coagulation cascade, was found in hemocytes from both Tachypleus tridentatus and Limulus polyphemus (Tanaka, S., et al. (1982) Biochem. Biophys. Res. Commun. 105, 717-723). The principle isolated from the Tachypleus hemocyte lysate by column chromatographies on dextran sulfate-Sepharose CL-6B and Sephadex G-50 under sterile conditions was a simple basic protein with an apparent molecular weight of 15,000. It consisted of a single chain polypeptide containing a total of 128 amino acids. The COOH-terminal end was presumed to be histidine, but no NH2-terminal end reactive to phenylisothiocyanate was detected. The isolated anti-LPS factor specifically inhibited the endotoxin-mediated activation of factor C, which has recently been identified as an LPS-sensitive serine protease zymogen in the hemocytes. This inhibition appeared to be due to the binding of anti-LPS factor with LPS. Moreover, anti-LPS factor had an antibacterial effect on the growth of Gram-negative bacteria (Salmonella minnesota R595 and 1114W) but not on that of Gram-positive bacteria (Staphylococcus aureus 209P). These biological activities of the isolated anti-LPS factor suggest an important role in cellular defence of limulus against microbial invasion.

Amino Acids↗

Recent advances in the gyro centrifugal ventricular assist device.

The gyro pump was developed as an intermediate-term assist pump (C1E3) as well as a long-term centrifugal ventricular assist device (VAD). The antithrombogenic design concept of this pump was confirmed throughout three 1 month ex vivo studies. The normalized index of hemolysis (NIH) of this gyro C1E3 model was lower than that of the BP-80. In the next step, a miniaturized centrifugal blood pump (The Gyro permanently implantable model PI-601) has been developed for use as a permanently implantable device after design optimization. A special motor design of the magnet circuit was utilized in this system in collaboration with the University of Vienna. The priming volume of this pump is 20 ml. The overall size of the pump actuator package is 53 mm in height, 65 mm in diameter, 145 ml of displacement volume, and 305 g in weight. This pump can provide 5 L/min against 120 mm Hg total pressure head at 2,000 rpm. The NIH value of this pump was comparable to that of the BP-80. The gyro PI-601 model is suitable for a VAD. The expected life from the endurance study is approximately 8 years. The evolution from C1E3 to the PI-601 converts this pump to a totally implantable centrifugal pump. Recent technologic advances in continuous flow devices are likely to realize a miniaturized and economical totally implantable VAD.

Animals↗