Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction.

This paper presents a new reconstruction algorithm for both single- and dual-energy computed tomography (CT) imaging. By incorporating the polychromatic characteristics of the X-ray beam into the reconstruction process, the algorithm is capable of eliminating beam hardening artifacts. The single energy version of the algorithm assumes that each voxel in the scan field can be expressed as a mixture of two known substances, for example, a mixture of trabecular bone and marrow, or a mixture of fat and flesh. These assumptions are easily satisfied in a quantitative computed tomography (QCT) setting. We have compared our algorithm to three commonly used single-energy correction techniques. Experimental results show that our algorithm is much more robust and accurate. We have also shown that QCT measurements obtained using our algorithm are five times more accurate than that from current QCT systems (using calibration). The dual-energy mode does not require any prior knowledge of the object in the scan field, and can be used to estimate the attenuation coefficient function of unknown materials. We have tested the dual-energy setup to obtain an accurate estimate for the attenuation coefficient function of K2 HPO4 solution.

Algorithms↗

Medical image segmentation using analysis of isolable-contour maps.

A common challenge for automated segmentation techniques is differentiation between images of close objects that have similar intensities, whose boundaries are often blurred due to partial-volume effects. We propose a novel approach to segmentation of two-dimensional images, which addresses this challenge. Our method, which we call intrinsic shape for segmentation (ISeg), analyzes isolabel-contour maps to identify coherent regions that correspond to major objects. ISeg generates an isolabel-contour map for an image by multilevel thresholding with a fine partition of the intensity range. ISeg detects object boundaries by comparing the shape of neighboring isolabel contours from the map. ISeg requires only little effort from users; it does not require construction of shape models of target objects. In a formal validation with computed-tomography angiography data, we showed that ISeg was more robust than conventional thresholding, and that ISeg's results were comparable to results of manual tracing.

Algorithms↗

Cost identification of abdominal aortic aneurysm imaging by using time and motion analyses.

PURPOSE: To compare the costs of performing helical computed tomographic (CT) angiography with three-dimensional rendering versus intraarterial digital subtraction angiography (DSA) for preoperative imaging of abdominal aortic aneurysms (AAAs). MATERIALS AND METHODS: A single observer determined the variable direct costs of performing nine intraarterial DSA and 10 CT angiographic examinations in age- and general health-matched patients with AAA by using time and motion analyses. All personnel directly involved in the cases were tracked, and the involvement times were recorded to the nearest minute. All material items used during the procedures were recorded. The cost of labor was determined from personnel reimbursement data, and the cost of materials, from vendor pricing. The variable direct costs of laboratory tests and using the ambulatory treatment unit for postprocedural monitoring, as well as all fixed direct costs, were assessed from hospital accounting records. The total costs were determined for each procedure and compared by using the Student t test and calculating the CIs. RESULTS: The mean total direct cost of intraarterial DSA (+/- SD) was $1,052 +/- 71, and that of CT angiography was $300 +/- 30, which are significantly different (P < 4.1 x 10(-11)). With 95% confidence, intraarterial DSA cost 3.2-3.7 times more than CT angiography for the assessment of AAA. CONCLUSION: Assuming equal diagnostic utility and procedure-related morbidity, institutions may have substantial cost savings whenever CT angiography can replace intraarterial DSA for imaging AAAs.

Accounting↗

Automated polyp detector for CT colonography: feasibility study.

An abdominal computed tomographic scan was modified by inserting 10 simulated colonic polyps with use of methods that closely mimic the attenuation, noise, and polyp-colon wall interface of naturally occurring polyps. A shape-based polyp detector successfully located six of the 10 polyps. When settings that enhanced the edge profile of polyps were chosen, eight of 10 polyps were detected. There were no false-positive detections. Shape analysis is technically feasible and is a promising approach to automated polyp detection.

Colon↗

Stair-step artifacts with single versus multiple detector-row helical CT.

PURPOSE: To compare the effects of acquisition parameters on the magnitude and appearance of artifacts between single and multiple detector-row helical computed tomography (CT). MATERIALS AND METHODS: A cylindric (12.7 x 305.0-mm) acrylic rod inclined 45 degrees relative to the z axis was scanned at the isocenter and 100 mm from the isocenter with single detector-row (single-channel) helical CT (beam width, 1-10 mm; pitch, 1.0, 2.0, or 3.0) and multiple detector-row (four-channel) helical CT (detector width, 1. 25, 2.5, 3.75, and 5 mm; pitch, 0.75 or 1.5). The SD of radius measurements along the rod (SD(r)) was used to quantify artifacts in all 72 data sets and to analyze their frequency patterns. Volume-rendered images of the data sets were ranked by six independent and blinded readers; findings were correlated with acquisition parameters and SD(r) measurements. RESULTS: SD(r) was smaller in four- than in single-channel helical CT for any given table increment (TI). In single-channel helical CT, SD(r) increased linearly with beam width and geometrically with pitch. In four-channel helical CT, SD(r) measurements were directly proportional to the TI, regardless of the detector width and pitch combination used. Off-center object position on average increased SD(r) by a factor of 1.6 for single-channel helical CT and by a factor of 2.0 for four-channel helical CT. Subjective rankings of image quality correlated excellently with SD(r) (Spearman r = 0.94, P <.001). CONCLUSION: Artifacts are quantitatively and subjectively smaller with four- compared with single-channel helical CT for any given TI.

Artifacts↗

Fast 3D cardiac cine MR imaging.

We describe a technique for three-dimensional cine MR imaging. By using short repetition times (TR) and interleaved slice encoding, volumetric cine data can be acquired throughout the cardiac cycle with a temporal resolution of approximately 80 msec. A T1-shortening agent is used to produce contrast between blood and myocardium. A comparison between the acquisition times of this and several other two-dimensional techniques is presented.

Contrast Media↗

Longitudinal sampling and aliasing in spiral CT.

Although analyses of in-plane aliasing have been done for conventional computed tomography (CT) images, longitudinal aliasing in spiral CT has not been properly investigated. We propose a mathematical model of the three-dimensional (3-D) sampling scheme in spiral CT and analyze its effects on longitudinal aliasing. We investigated longitudinal aliasing as a function of the helical-interpolation algorithm, pitch, and reconstruction interval using CT simulations and actual phantom scans. Our model predicts, and we verified, that for a radially uniform object at the isocenter, the spiral sampling scheme results in spatially varying cancellation of the aliased spectral islands which, in turn, results in spatially varying longitudinal aliasing. The aliasing is minimal at the scanner isocenter, but worsens with distance from it and rapidly becomes significant. Our results agree with published results observed at the isocenter of the scanner and further provide new insight into the aliasing conditions at off-isocenter locations with respect to the pitch, interpolation algorithm, and reconstruction interval. We conclude that longitudinal aliasing at off-isocenter locations can be significant, and that its magnitude and effects cannot be predicted by measurements made only at the scanner isocenter.

Algorithms↗

Modeling of polychromatic attenuation using computed tomography reconstructed images.

This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.

Algorithms↗

Spatially varying longitudinal aliasing and resolution in spiral computed tomography.

Spiral computed tomography (CT) has revolutionized conventional CT as a truly three-dimensional imaging modality. A number of studies aimed at evaluating the longitudinal resolution in spiral CT have been presented, but the spatially varying nature of the longitudinal resolution in spiral CT has been largely left undiscussed. In this paper, we investigate the longitudinal resolution in spiral CT as affected by the spatially varying longitudinal aliasing. We propose the treatment of aliasing as a signal dependent, additive noise, and define a new image quality parameter, the contrast-to-aliased-noise ratio (CNaR), that relates to possible image degradation or loss of resolution caused by aliasing. We performed CT simulations and actual phantom scans using a resolution phantom consisting of sequences of spherical beads of different diameters, extending along the longitudinal axis. Our results show that the off-isocenter longitudinal resolution differs significantly from the longitudinal resolution at the isocenter and that the CNaR decreases with distance from the isocenter, and is a function of pitch and the helical interpolation algorithm used. The longitudinal resolution was observed to worsen with decreasing CNaR. We conclude that the longitudinal resolution in spiral CT is spatially varying, and can be characterized by the CNaR measured at the transaxial location of interest.

Computer Simulation↗

Display modes for CT colonography. Part II. Blinded comparison of axial CT and virtual endoscopic and panoramic endoscopic volume-rendered studies.

PURPOSE: To determine the sensitivity of radiologist observers for detecting colonic polyps by using three different data review (display) modes for computed tomographic (CT) colonography, or "virtual colonoscopy." MATERIALS AND METHODS: CT colonographic data in a patient with a normal colon were used as base data for insertion of digitally synthesized polyps. Forty such polyps (3.5, 5, 7, and 10 mm in diameter) were randomly inserted in four copies of the base data. Axial CT studies, volume-rendered virtual endoscopic movies, and studies from a three-dimensional mode termed "panoramic endoscopy" were reviewed blindly and independently by two radiologists. RESULTS: Detection improved with increasing polyp size. Trends in sensitivity were dependent on whether all inserted lesions or only visible lesions were considered, because modes differed in how completely the colonic surface was depicted. For both reviewers and all polyps 7 mm or larger, panoramic endoscopy resulted in significantly greater sensitivity (90%) than did virtual endoscopy (68%, P = .014). For visible lesions only, the sensitivities were 85%, 81%, and 60% for one reader and 65%, 62%, and 28% for the other for virtual endoscopy, panoramic endoscopy, and axial CT, respectively. Three-dimensional displays were more sensitive than two-dimensional displays (P < .05). CONCLUSION: The sensitivity of panoramic endoscopy is higher than that of virtual endoscopy, because the former displays more of the colonic surface. Higher sensitivities for three-dimensional displays may justify the additional computation and review time.

Colonic Polyps↗

Display modes for CT colonography. Part I. Synthesis and insertion of polyps into patient CT data.

PURPOSE: To develop and validate a method for the insertion of digitally synthesized polyps into computed tomographic (CT) images of the human colon for use as ground truth for evaluation of virtual colonoscopy. MATERIALS AND METHODS: Spiral CT simulator software was used to generate 10 synthetic polyps in various configurations. Additional software was developed to insert these polyps into volume CT scans. Ten polyps in eight patients were selected for comparison. Three radiologists evaluated whether two-dimensional (2D) CT images and three-dimensional (3D) volume-rendered CT images showed synthetic or real polyps. RESULTS: Edge-response profiles and noise of simulated polyps matched those of native polyps. Frequency distributions of reviewers' responses were not significantly different for synthetic versus real polyps in either 3D or 2D images. Responses were clustered around the response of "unsure" if lesions were real or synthetic. Receiver operating characteristic curves had areas of 0.54 (95% CI = 0.39, 0.68) for 3D and 0.39 (95% CI = 0.25, 0.53) for 2D images, which were not significantly different from random guessing (P = .70 and .28 for 3D and 2D images, respectively). CONCLUSION: Synthetic polyps were indistinguishable from real polyps. This method can be used to generate ground truth experimental data for comparison of CT colonographic display and detection methods.

Adult↗

Virtual endoscopy using perspective volume-rendered three-dimensional sonographic data: technique and clinical applications.

OBJECTIVE: We present a technique for obtaining three-dimensional external and virtual endoscopy views of organs using perspective volume-rendered gray-scale and Doppler sonographic data, and we explore potential clinical applications in the carotid artery, the female pelvis, and the bladder. CONCLUSION: Using the proposed methods, radiologists will find it possible to create virtual endoscopy and external perspective views using sonographic data. The technique works well for revealing the interior of fluid-filled structures and cavities. However, expected improvements in computer performance and integration with existing sonographic equipment will be necessary for the technique to become practical in the clinical environment.

Carotid Arteries↗

Computed tomographic angiography: historical perspective and new state-of-the-art using multi detector-row helical computed tomography.

Since its clinical introduction in 1991, volumetric computed tomography scanning using spiral or helical scanners has resulted in a revolution for diagnostic imaging. In addition to new applications for computed tomography, such as computed tomographic angiography and the assessment of patients with renal colic, many routine applications such as the detection of lung and liver lesions have substantially improved. Helical computed tomographic technology has improved over the past eight years with faster gantry rotation, more powerful X-ray tubes, and improved interpolation algorithms, but the greatest advance has been the recent introduction of multi detector-row computed tomography scanners. These scanners provide similar scan quality at a speed gain of 3-6 times greater than single detector-row computed tomography scanners. This has a profound impact on the performance of computed tomography angiography, resulting in greater anatomic coverage, lower iodinated contrast doses, and higher spatial resolution scans than single detector-row systems.

Angiography↗

A new frame-based registration algorithm.

This paper presents a new algorithm for frame registration. Our algorithm requires only that the frame be comprised of straight rods, as opposed to the N structures or an accurate frame model required by existing algorithms. The algorithm utilizes the full 3D information in the frame as well as a least squares weighting scheme to achieve highly accurate registration. We use simulated CT data to assess the accuracy of our algorithm. We compare the performance of the proposed algorithm to two commonly used algorithms. Simulation results show that the proposed algorithm is comparable to the best existing techniques with knowledge of the exact mathematical frame model. For CT data corrupted with an unknown in-plane rotation or translation, the proposed technique is also comparable to the best existing techniques. However, in situations where there is a discrepancy of more than 2 mm (0.7% of the frame dimension) between the frame and the mathematical model, the proposed technique is significantly better (p < or = 0.05) than the existing techniques. The proposed algorithm can be applied to any existing frame without modification. It provides better registration accuracy and is robust against model mis-match. It allows greater flexibility on the frame structure. Lastly, it reduces the frame construction cost as adherence to a concise model is not required.

Algorithms↗

Automated flight path planning for virtual endoscopy.

In this paper, a novel technique for rapid and automatic computation of flight paths for guiding virtual endoscopic exploration of three-dimensional medical images is described. While manually planning flight paths is a tedious and time consuming task, our algorithm is automated and fast. Our method for positioning the virtual camera is based on the medial axis transform but is much more computationally efficient. By iteratively correcting a path toward the medial axis, the necessity of evaluating simple point criteria during morphological thinning is eliminated. The virtual camera is also oriented in a stable viewing direction, avoiding sudden twists and turns. We tested our algorithm on volumetric data sets of eight colons, one aorta and one bronchial tree. The algorithm computed the flight paths in several minutes per volume on an inexpensive workstation with minimal computation time added for multiple paths through branching structures (10%-13% per extra path). The results of our algorithm are smooth, centralized paths that aid in the task of navigation in virtual endoscopic exploration of three-dimensional medical images.

Algorithms↗

Measurement of the aorta and its branches with helical CT.

Contiguous orthonormal arterial cross sections, segment lengths, and curvature were semiautomatically quantified from helical computed tomographic (CT) angiographic data in phantoms and two patients. Measurements of mean diameter and curvature correlated with reference values (r2 = .99), and mean fractional errors were 0.07 and 0.06 for mean diameter and curvature measurements, respectively. Volumetric measurement showed a potential to increase the accuracy, precision, and diagnostic utility of CT angiography.

Adult↗

Virtual endoscopy of the paranasal sinuses using perspective volume rendered helical sinus computed tomography.

Our goal was to use three-dimensional information obtained from helical computed tomographic (CT) data to explore and evaluate the nasal cavity, nasopharynx, and paranasal sinuses by simulated virtual endoscopy (VE). This was done by utilizing a new image reconstruction method known as perspective volume rendering (PVR). Thin-section helical CT of the nasal cavity, nasopharynx, and paranasal sinuses was performed on a conventional CT scanner. The data were transferred to a workstation to create views similar to those seen with endoscopy. Additional views not normally accessible by conventional endoscopy were generated. Key perspectives were selected, and a video "flight" model was choreographed and synthesized through the nasal cavity and sinuses based on the CT data. VE allows evaluation of the nasal cavity, nasopharynx, and paranasal sinuses with appreciation of the relationships of these spatially complex structures. In addition, this technique allows structural visualization with unconventional angles, perspectives, and locations not conventionally accessible. Although biopsies, cultures, and lavages routinely done with endoscopy cannot be performed with VE, this technique holds promise for improving the diagnostic evaluation of the nasal cavity, the nasopharynx, and the paranasal sinuses. The unconventional visual perspectives and very low morbidity may complement many applications of simple diagnostic endoscopy.

Endoscopy↗

Accuracy of detection and measurement of renal calculi: in vitro comparison of three-dimensional spiral CT, radiography, and nephrotomography.

PURPOSE: To compare accuracy of three-dimensional (3D) spiral computed tomography (CT) performed without administration of contrast material with that of radiography and linear nephrotomography in detection and measurement of renal calculi. MATERIALS AND METHODS: Fifty renal calculi within an abdominal phantom were imaged with 3D spiral CT, radiography, and linear nephrotomography. Spiral CT data were analyzed with workstation-based 3D imaging software, with a thresholding procedure based on the maximally attenuating voxel within each calculus during measurement. Measurement accuracy and detection rates were compared according to modality. Conventional and magnification-corrected measurements from radiography and linear nephrotomography were included. RESULTS: Spiral CT depicted calculi and allowed determination of the collective two-dimensional and 3D linear measurements statistically significantly more accurately than the other techniques; the mean linear measurement errors along individual axes did not exceed 3.6%. With 3D spiral CT, calculus volumes were determined with a mean error of -4.8%. CONCLUSION: 3D spiral CT enabled highly accurate determination of the volumes and all three linear dimensions of renal calculi. In addition, 3D spiral CT depicted calculi more sensitively than traditional techniques and provided new information and improved accuracy in the evaluation of nephrolithiasis.

Bias↗