Search PubMedSearch

Biomedical subjects

S Naimuddin

Publications and source records attributed to S Naimuddin.

3 recordsLinked to original sources

Digital beam attenuator technique for compensated chest radiography.

The feasibility of producing patient-specific beam attenuators for chest radiography has been investigated using an anthropomorphic phantom and a human volunteer. A low-dose test exposure is digitized, processed, and used to print a small cerium filter, which is placed in the x-ray beam near the collimator. The final radiograph is recorded on film. The technique results in relatively uniform film exposure, so that structures in all regions of the chest are simultaneously displayed with optimal film contrast. The equalized exposure improves image quality in the normally underpenetrated regions and reduces the role of cross-scatter from the lungs. The image is analogous to optical or computer-processed unsharp masking techniques, but the processing is accomplished in the x-ray beam and results in an improved exposure distribution, giving advantages that cannot be achieved with image processing techniques alone.

Humans

Geometrical properties of a digital beam attenuator system.

A digital beam attenuator system has been developed to automatically generate patient-specific compensating filters for chest radiography. An initial low-dose test image is used to generate the attenuator, which is fabricated by overprinting multiple layers of a heavy-metal material onto a nonattenuating substrate. The attenuator is subsequently inserted into the x-ray beam for a final compensated radiograph. The effects of focal spot blurring and limited attenuator resolution result in the final compensated image containing only high-spatial frequency information. The frequency response of the process is not strictly describable by a modulation transfer function, but an approximation of the frequencies remaining in the compensated image is obtained for low-contrast conditions. It is found that a 4 X 4 blurring function on the original 64 X 64 test image is required for the attenuator to give appropriate compensated image appearance. A proposed attenuator printing scheme prints the attenuator in a 16 X 16 matrix, staggering successively printed layers to achieve the required 64 X 64 sampling with appropriate blurring. The resulting compensated image has good anatomical definition and contains a frequency response similar to that obtained by compensation techniques being investigated by Plewes and Sorenson.

Humans

Scatter-glare correction using a convolution algorithm with variable weighting.

Several investigators have approximated the scatter component of digital radiographic images by applying a constant weighting factor to a convolved version of the detected image. The scatter approximation is then subtracted from the detected image. When a constant weighting factor is used, the scatter in areas of low transmission is underestimated. We have extended this technique by allowing for a spatially variable weighting factor based on the local image intensity. This technique improves the scatter estimate and should provide better results for general videodensitometric applications.

Algorithms