Search PubMed⌕ Search

Biomedical subjects

S N Oesterle

Publications and source records attributed to S N Oesterle.

At least 37 records · Page 2Linked to original sources

Coronary stents: In vitro aspects of an angiographic and ultrasound quantification with in vivo correlation.

BACKGROUND: The validity of quantitative coronary angiography (QCA) after stent placement has been questioned because the optical density of a metallic stent, added to the density of a contrast-filled lumen, could affect border definition. METHODS AND RESULTS: We deployed 3.0- and 4.0-mm Palmaz-Schatz, Wiktor, Multilink, NIR, and InStent stents in precision-cast phantoms. Central lumens of 2.0 mm were created. There was no difference between the "true" diameters of any stented lumen by both QCA and quantitative ultrasonic (QCU) measurement poststenting. QCA systematic error (SE) varied from 0.01 for the Wiktor stents to 0.14 mm for the Palmaz-Schatz stents; the random error (RE) was 0.03 to 0.14 mm. QCU SE varied from 0.05 to 0.11 mm, and RE ranged from 0.01 to 0.07 mm. At the next stage, 4.0-mm Wiktor and Palmaz-Schatz stents were deployed into the phantom lumens; 1.5-, 2.0-, 2.5- and 3.0-mm lumens were created inside the stents. QCA and QCU measurements of 1.5- to 2.5-mm residual lumens were overestimated by 0.1 to 0.3 mm. In the 3. 0-mm residual lumen within the Wiktor stent, QCA underestimated the luminal size by -0.1 mm. There was no QCA inaccuracy for a 3.0-mm lumen within the Palmaz-Schatz stent. In patients, in 25 stented segments in both the Palmaz-Schatz and Wiktor groups, there was no difference between QCA and QCU diameters. CONCLUSIONS: QCU is sufficiently precise for the assessment of the coronary lumen after stenting. QCA can be used as an accurate method of poststent assessment, except when a very mild recurrence within a highly opaque stent is measured. In that instance, QCA may underestimate the luminal diameter.

Coronary Angiography↗

Initial results of laser-based percutaneous myocardial revascularization for angina pectoris.

Results of a 30-patient pilot study of a recently developed percutaneous myocardial revascularization approach are described. The feasibility and positive safety profile of percutaneous myocardial revascularization are clearly demonstrated, with no mortality associated with the treatment or in the immediate post-treatment period and an incidence of only 1 major complication.

Aged↗

Laser wire for crossing chronic total occlusions: "learning phase" results from the U.S. TOTAL trial. Total Occlusion Trial With Angioplasty by Using a Laser Wire.

The Prima laser guidewire system (Spectranectics Corp., Colorado Springs, CO) consists of an 0.018" hypotube containing a bundle of 45-microm optical fibers coupled to a pulsed excimer laser operating at a tip fluence of 60 ml/mm2 and a repetition rate ranging from 25-40 Hz. This laser guidewire was specifically designed to cross total occlusions refractory to passage with conventional wires. The Prima wire was evaluated in a feasibility study at 15 U.S. centers. Following failure to cross a total occlusion with approved guidewires, the Prima wire was utilized in 179 patients. Average age of subjects was 61 yr. Lesion locations included left anterior descending (36%), right (45%), and circumflex (19%) coronary arteries. Mean angiographic age of total occlusions was 70 wk (range, 2-1,020 wk, median, 14 wk). The use of the Prima wire either solely or in combination with conventional guidewires resulted in successful crossing in 61% of these previously impenetrable occlusions. Failure of the device was commonly related to length of the occlusion and tortuosity along the occluded pathway. Major complications included myocardial infarction in 7 patients (3.9%), tamponade in 3 (1.7%), and death in 2 (1.1%). This "learning phase" pilot study confirmed the feasibility of a laser guidewire in chronic total occlusions that are resistant to passage of conventional guidewires. An extended registry at these investigative sites is planned.

Adult↗

Intracoronary radiation with a 32P source wire.

The Proliferation REduction with Vascular ENergy Trial (PREVENT) is a prospective randomized study of the safety and efficacy of intracoronary brachytherapy to reduce restenosis. A beta-emitter, 32P, is embedded on a wire tip and delivered to the target site through a centering catheter immediately following a coronary intervention. The radiation doses are 16, 20, and 24 Gy measured at 1 mm within the vessel wall. Follow-up includes an angiogram and IVUS at 6 months. Phase I of this trial has been completed with results expected in early 1999.

Angioplasty, Balloon, Coronary↗

The stent decade: 1987 to 1997. Stanford Stent Summit faculty.

In January 1997, experts from the United States, Europe, and Japan gathered at Stanford University to review their collective experience with intracoronary and noncoronary stenting and to identify and prioritize issues requiring further clinical investigation. This report summarizes the discussions that took place during this stent summit. Knowledge of stent-tissue interaction from animal and human pathologic specimens was reviewed in the context of evolving stent designs. The relative merits of coil and slotted tubular stent designs were discussed. Stent deployment routines, including self-expansion, balloon expansion, and high-pressure delivery were debated. The potential for covered stents and coated stents was explored. Problems surrounding the routine deployment of stents were identified: small vessel disease, long lesions, bifurcation stenoses, vein graft disease, ostial disease, left main stenoses, and intrastent restenosis. The value of intravascular ultrasound, as an adjunct to stenting, was explored and debated. An algorithm for "provisional stenting" based on ultrasound criteria was developed. Noncoronary stenting of the aorta, iliacs, and carotids were discussed. Clinical applications that may lead to randomized clinical trials were identified.

Carotid Arteries↗

Enhancement of spatial orientation of intravascular ultrasound images with side holes in guiding catheters.

BACKGROUND: Intravascular ultrasound (IVUS) images are typically viewed and recorded in an arbitrary rotational orientation. This study was performed to validate a new method for improved orientation of sonographic vascular cross-sections. METHODS AND RESULTS: We have tested a simple technique for rotational indexing of IVUS in cases in which guiding catheters with side holes are used. Although guiding catheters are opaque to ultrasonography, the side holes transmit the beam and therefore can be easily identified. The orientation of the side holes, which is characteristic for each make of guiding catheter, can be used to determine the anatomically appropriate rotational orientation of the IVUS image. In this study images of four commercially available side-hole guiding catheters were viewed in vitro to confirm the visibility of the side holes and to characterize their orientation for purposes of rotational orientation of images. Feasibility tests of rotational orientation based on side holes were then performed in canine coronary arteries (n = 3) and in six human coronary arteries. Three serial imaging runs in each clinical case yielded a mean variability in rotational orientation of 7.5 +/- 1.5 degrees. CONCLUSION: Validation testing of the side-hole technique demonstrates the potential for consistent and anatomically appropriate orientation of intravascular ultrasound images.

Animals↗

Beyond stents: third-generation coronary devices.

Despite extraordinary growth in percutaneous transluminal coronary angioplasty (>400,000 cases in United States in 1997) patients are still routinely referred for bypass grafting in large numbers. Why? Second-generation devices (directional coronary atherectomy, high-speed rotational atherectomy [Rotablator], and stents) have expanded the application of percutaneous catheter treatment of coronary disease. Specifically, highly eccentric lesions in large vessels, heavily calcified lesions, and coronary dissections can be effectively treated with these devices. Stents have substantially reduced the incidence of restenosis, but this benefit is largely confined to vessels more than 3 mm in diameter and stenoses less than 20 mm in length. A third generation of coronary devices has evolved in the late 1990s in response to continuing failures of conventional balloon angioplasty, atherectomy, and stenting. The failures of the 1990s were (1) restenosis, including in-stent restenosis, (2) chronic total occlusions, (3) diffuse small-vessel disease, and (4) aged vein graft disease. In response to these challenges novel devices are being developed: (1) for restenosis, intracoronary radiation therapy (brachytherapy); (2) for chronic total occlusions, Prima Laser wire; (3) for diffuse small-vessel disease, percutaneous myocardial laser revascularization; and (4) for aged vein grafts, antiembolization devices. Each of these new catheter technologies will need to be economically and clinically reconciled with the multitude of minimally invasive surgical revascularization techniques that are rapidly evolving.

Angioplasty, Balloon, Coronary↗

Early systolic mitral leaflet "loitering" during acute ischemic mitral regurgitation.

BACKGROUND: The mechanism by which incomplete mitral leaflet coaptation develops during ischemic mitral regurgitation is debated, with recent studies suggesting that incomplete mitral leaflet coaptation may be due to apically displaced papillary muscle tips. Yet quantitative in vivo three-dimensional mitral leaflet motion during ischemic mitral regurgitation has never been described. METHODS: Radiopaque markers (sutured around the mitral anulus, to the central free mitral leaflet edges, and to both papillary muscle tips and bases) were imaged with the use of biplane videofluoroscopy in six closed-chest, sedated sheep before (control) and during induction of acute ischemic mitral regurgitation. Leaflet coaptation was defined as the minimum distance measured between edge markers during control conditions. RESULTS: During control, leaflet coaptation occurred 23 +/- 7 msec (mean +/- standard error of the mean) after end-diastole, when left ventricular pressure was 27 +/- 6 mm Hg. During ischemic mitral regurgitation, coaptation was delayed to 115 +/- 19 msec after end-diastole (p < or = 0.01 vs control [n = 4]) when left ventricular pressure was 88 +/- 4 mm Hg. At end-diastole during ischemic mitral regurgitation, the mitral anulus area was 14% +/- 2% larger than control (7.4 +/- 0.3 cm2 vs 6.5 +/- 0.2 cm2, p < or = 0.005) as the result of the lengthening of muscular annular regions (76.0 +/- 2.5 mm vs 70.5 +/- 1.4 mm, p < or = 0.01). Mitral anulus shape (ratio of two diameters) at end-diastole was more circular during ischemic mitral regurgitation (0.79 +/- 0.01 vs 0.71 +/- 0.02, p < 0.01). At end-diastole during ischemic mitral regurgitation, the posterior papillary muscle tip was displaced 1.5 +/- 0.5 mm laterally and 2.0 +/- 0.6 mm posteriorly (p < or = 0.02 vs control), but there was no apical displacement of either papillary muscle tip. CONCLUSIONS: Incomplete mitral leaflet coaptation during acute ischemic mitral regurgitation occurred early in systole, not at end-systole, and was due to "loitering" of the leaflets associated with posterior mitral anulus enlargement and circularization, as well as some posterolateral, but not apical, posterior papillary muscle tip displacement. These data suggest that early systolic mitral anulus dilatation and shape change and altered posterior papillary muscle motion are the primary mechanisms by which incomplete mitral leaflet coaptation occurs during acute ischemic mitral regurgitation.

Acute Disease↗

Geometric determinants of ischemic mitral regurgitation.

BACKGROUND: The precise geometric determinants of ischemic mitral regurgitation (MR) are incompletely understood, although such knowledge is important to improve mitral valve reparative techniques. METHODS AND RESULTS: The three-dimensional geometry of the mitral apparatus was studied using radiopaque markers in eight closed-chest dogs with acute posterior left ventricular wall ischemia either with (MR) or without (no-MR) MR as assessed by using color Doppler. Using a cylindrical coordinate system (origin at the midpoint between the mitral annulus commissures [anterolateral and posteromedial] and z-axis directed toward the left ventricular apex), we measured the distance to the midpoint (z, in millimeters), radial distance from the z-axis (r, in millimeters), and angle from the intercommissural line (theta) of each marker. A multivariate analysis of variance showed the following differences (P < .005) between the MR and the no-MR groups: 1) markedly increased r of the posterior papillary muscle tip (10.3 versus 6.4 mm, MR versus no-MR, at end-systole) and increased r of the anterior papillary muscle tip; 2) dilation (in the septal-lateral direction) of the midpart of the mitral annulus and near the anterolateral region; 3) increased posterior mitral leaflet r near both commissures (eg, 8.3 versus 6.2 mm on the posteromedial side) and increased z (ie, shifted toward the left ventricular apex) of the posterior leaflet on the anterolateral side (eg, 7.0 versus 6.2 mm), which is analogous to restricted (or type III) leaflet motion. CONCLUSIONS: These findings indicate that the geometric determinants of ischemic MR in dogs are complex and involve many parts of the mitral valve apparatus. This complexity suggests that surgical attention to the entire annulus and excursion of the posterior leaflet may be helpful when annuloplasty alone is inadequate.

Animals↗

Routine platelet transfusion in patients undergoing emergency coronary bypass surgery after receiving abciximab.

Abciximab has been shown to reduce the ischemic complications of high-risk angioplasty procedures. The appropriate management of patients who have received abciximab and require emergency coronary artery bypass surgery after failed coronary angioplasty is as yet undetermined. We present the outcomes of a small series of such patients who were given platelet transfusions before or during cardiopulmonary bypass.

Abciximab↗

Role of compensatory enlargement and shrinkage in transplant coronary artery disease. Serial intravascular ultrasound study.

BACKGROUND: Compensatory enlargement of the vessel wall has been described in the early stages of native atherosclerosis. Whether compensatory enlargement plays a role in transplant coronary artery disease is not known. The objective of this study was to determine, by use of serial intravascular ultrasound (IVUS), whether compensatory dilation occurs in transplant coronary artery disease over time. METHODS AND RESULTS: Seventy-five heart transplant recipients with 151 matched coronary segments were selected for the presence of intimal disease progression as detected by serial IVUS examinations 1 to 3 years apart. Intimal disease progression was defined as a > 10% increase in intimal area (IA). IVUS catheter location in follow-up studies was verified angiographically in relation to branch vessels. Luminal area (LA) and total vessel area (TA) were measured at each site. Intimal area (IA = TA-LA) was calculated. Changes in IA (delta IA) and TA (delta TA) between baseline and follow-up IVUS were compared: delta IA, 2.9 +/- 0.2 mm2: delta TA, 2.7 +/- 0.4 mm2. A remodeling index (RI) was defined as RI = delta TA/delta IA. Three subgroups could be distinguished: over compensation (RI > I), partial compensation (RI 0 to 1), and no compensation or shrinkage (RI < or = 0). Seventy-four segments (49%) showed overcompensation, 44 (29%) showed partial compensation, and 33 (22%) showed no compensation or shrinkage. CONCLUSIONS: In this study, serial IVUS shows that early after cardiac transplantation, a large proportion of the coronary segments with progression of intimal thickening have compensatory dilation of the vessel wall. However, a substantial number of coronary segments (22%) show no compensatory dilation or shrinkage. The progressive luminal narrowing in transplant patients may be due in part to vessel shrinkage or the lack of compensatory dilation over time.

Adult↗

Percutaneous method of laser transmyocardial revascularization.

Laser transmyocardial revascularization (TMR) creates conduits from the left ventricular cavity into the myocardium and has been forwarded as a potential method of perfusing ischemic myocardium. The procedure typically employs a CO2 laser to produce transmyocardial channels from the epicardial to the endocardial surface via an open thoracotomy. Preliminary studies in animals and human subjects have yielded promising results, and clinical trials evaluating the long-term efficacy of the procedure are in progress. We now report the use of a percutaneous method of TMR using a laser delivered through a novel catheter system. To assess the feasibility of performing percutaneous TMR, studies were performed on 15 adult canine subjects utilizing a holmium:YAG laser. Via a femoral artery approach, novel laser catheters were introduced into the left ventricular cavity under fluoroscopic guidance. Biplane coronary angiography, ventriculography, and transesophageal echocardiography were employed to direct catheters to specific regions and assess the efficacy of creating transmyocardial channels. Multiple channels could be created in the anterior, lateral, inferoposterior, and septal regions as demonstrated by contrast ventriculography with confirmation by subsequent gross and histologic examination. The procedure was tolerated well without any ventricular dysfunction or sustained ventricular arrhythmias. We have demonstrated that laser transmyocardial revascularization via a percutaneous approach is feasible with creation of channels from the endocardial surface of the left ventricle into the myocardium. On gross and histological examination, these channels are similar in appearance to those created by the currently employed open chest, epicardial method of TMR.

Angioplasty, Balloon, Laser-Assisted↗

Coronary AVE micro stents: serial quantitative angiography and histology in a canine model.

The AVE Micro Stent (AVE Inc., Santa Rosa, CA) is composed of helically welded 3 mm long, zigzag crowns with stent lengths from 6 to 39 mm and diameters from 2.5 to 4.5 mm. Quantitative coronary angiography and histologic analyses of acute and chronic implantation were obtained in 52 stented coronary segments of 18 dogs. Three hearts with 8 stented coronary segments were harvested after 24 hr, 3 hearts with 9 stented segments were harvested after 2 weeks, 6 hearts with 15 stented segments were harvested at 8 weeks, and 6 hearts with 20 stented segments were harvested at 24 weeks post-deployment. There were no procedural complications, deaths, or acute vessel closures. The average lumen diameter of the stented segment was largest at 2 weeks (3.3 +/- 0.3 mm). The smallest average diameters were observed at 8 weeks after the stent deployment (2.7 +/- 0.4, P < 0.05) with an increase again at 24 weeks (2.9 +/- 0.6). The pre-explant percent of stenosis was <30% in all animals. Histologically, a peak of inflammation was visible at 2 weeks; however, the extent of luminal narrowing reached its peak at 8 weeks and the lumen dimension increased somewhat at 24 weeks. The degree of intimal thickening remained relatively constant throughout the different time points (<200 microm). Overall, these data suggest that constrictive remodeling within the stented segment occurs at 8 weeks in this animal model. The later increase of the stented segment dimensions as well as higher net gain at 24 weeks compared to 8 weeks after deployment suggests that this constriction is a transitory phenomenon.

Angioplasty, Balloon, Coronary↗

Percutaneous transmyocardial revascularization.

Transmyocardial revascularization (TMR) is a potential therapy for patients with severe angina pectoris and coronary anatomy deemed unsuitable for traditional revascularization techniques. Investigations of TMR are reviewed with emphasis on studies relevant to the development of a percutaneous, catheter-based transmyocardial revascularization procedure (PMR). The results of the preliminary animal studies and description of the PMR procedure are discussed. The recently initiated human PMR protocol is summarized and possible future investigative directions are outlined.

Animals↗

Primary angioplasty for acute myocardial infarction.

The use of thrombolytic therapy has been widely accepted for the treatment of acute myocardial infarction. Despite improving mortality, thrombolytic therapy may be contraindicated in many patients presenting with myocardial infarction and is associated with a small, yet significant risk of hemorrhagic sequelae. This article outlines the rationale behind reperfusion therapy, the use of pharmacological thrombolysis and the role of adjunctive angioplasty. The potential advantages of a therapeutic strategy of primary angioplasty, instead of thrombolysis, are discussed. These include anatomical definition, risk stratification, reduced recurrent ischemia, enhanced coronary perfusion and improved coronary patency. The randomized trials in which primary angioplasty and thrombolytic therapy were compared are reviewed. We conclude that angioplasty results in a reduction of short-term mortality and nonfatal reinfarction and therefore advocate the routine use of coronary angioplasty as a primary reperfusion strategy for acute myocardial infarction. The potential limitations of primary angioplasty in the community hospital setting are discussed. Finally, we examine the roles of adjunctive mechanical (e.g. stents) and pharmacological (e.g. Abciximab) means of further enhancing outcomes after primary angioplasty.

Angioplasty, Balloon, Coronary↗

Are heart-lung transplant recipients protected from developing transplant coronary artery disease? A case-matched intracoronary ultrasound study.

BACKGROUND: Accelerated coronary artery disease is a major cause of mortality in heart transplant recipients; however, it does not appear to play a major role in the clinical outcome of heart-lung transplant recipients. The purpose of this study was to determine whether the incidence and severity of transplant coronary artery disease as detected by intracoronary ultrasound in heart-lung transplant recipients are less than those encountered in heart transplant recipients. METHODS AND RESULTS: We studied the left anterior descending coronary artery with the use of intracoronary ultrasound imaging in 22 heart-lung transplant recipients at the time of their routine annual coronary angiogram. Twenty-two heart transplant recipients were case matched for number of years after transplant at ultrasound study, recipient age, donor age, and diagnosis of nonischemic cardiomyopathy. Mean intimal area, intimal index, Stanford class, and incidence of at least moderate disease (Stanford class > or = 3) were measured and calculated in each group and then compared between the two groups. Mean intimal area (1.6 +/- 2.5 versus 3.8 +/- 2.8 mm2), mean intimal index (0.07 +/- 0.10 versus 0.22 +/- 0.14), mean Stanford class (1.7 +/- 1.0 versus 2.7 +/- 1.2), and incidence of Stanford class > or = 3 (14% versus 45%) were significantly lower in the heart-lung transplant recipient group. CONCLUSIONS: The incidence and severity of transplant coronary artery disease are much less in patients receiving heart-lung transplants than in those receiving heart transplants alone.

Adult↗

Outcome of narrowing related side branches after high-speed rotational atherectomy.

High-speed rotational atherectomy (HSRA) is advocated for calcified and diffusely narrowed coronary arteries. There are often side branches involving these kinds of lesions. The presence of significant lesion-related side branches has been considered a relative contraindication to rotational atherectomy. This study was performed to determine the rate, predictors, and outcome of side branch occlusion after HSRA. The angiograms of 418 patients were examined with 320 side branches in 240 target vessels of > or = 1 mm in diameter being identified. Vessels were scored as either perfused (Thrombolysis In Myocardial Infarction 2 or 3 flow) or occluded (Thrombolysis In Myocardial Infarction 0 or 1 flow before and after the procedure. A detailed quantitative angiographic analysis was performed on a total of 108 side branches including all cases of branch occlusion. Clinical outcomes were determined in all cases with side branch loss. There were 24 occlusions in 21 patients after the procedure, giving a rate of branch loss of 7.5%. Follow-up angiography of > or = 24 hours was available for 13 of the occluded branches and 12 were found to be patent. In the 21 patients with branch occlusion, 6 sustained a myocardial infarct (of which 5 were non-Q-wave), 2 underwent coronary artery bypass grafting, and 2 died. There are frequently lesion-associated side branches in the types of vessels to undergo HSRA. These branches remained patent 92.5% of the time, with occlusion occurring infrequently and usually being transient. When occlusion did occur, there was a 29% incidence of myocardial infarction.

Aged↗