Search PubMed⌕ Search

Biomedical subjects

S N Gupta

Publications and source records attributed to S N Gupta.

At least 19 recordsLinked to original sources

Attenuated myocardial vasodilator response in patients with hypertensive hypertrophy revealed by oxygenation-dependent magnetic resonance imaging.

BACKGROUND: Oxygen (O(2)) homeostasis is central to myocardial tissue functioning, and increased O(2) demand is thought to be satisfied by a vasodilatory mechanism that results in increased blood and O(2) delivery. We applied blood oxygenation level-dependent (BOLD) MRI in conjunction with vasodilatory stress to index the ability to augment intramyocardial oxygenation in hypertensive hypertrophy, the primary cause of heart failure. METHODS AND RESULTS: Nine healthy controls and 10 hypertensive subjects with moderate-to-severe hypertrophy underwent imaging on a 1.5 T clinical scanner. The dipyridamole-induced change in the apparent transverse relaxation rate, R2*, which correlates with hemoglobin oxygenation, was -5.4+/-2.2 s(-1) (95% CI, -4.0 to -6.8 s(-1)) in controls compared with -1.7+/-1.4 s(-1) (95% CI, -0.8 to -2.6 s(-1)) in hypertensive patients (P=0.0003). CONCLUSIONS: Patients with hypertensive hypertrophy demonstrate an impaired ability to increase intramyocardial oxygenation during vasodilatory stress, as indexed by BOLD MRI. The capacity to image vascular function with BOLD MRI may advance the understanding of the development of ventricular dysfunction in hypertension.

Adult↗

First-pass myocardial perfusion MR imaging with interleaved notched saturation: feasibility study.

The authors evaluated a magnetization preparation scheme with a "notched" section profile for T1-weighted first-pass myocardial perfusion magnetic resonance (MR) imaging at 1.5 T. The pulse sequence consisted of a preparation sequence followed by an interleaved gradient-echo echo-planar sequence. Image contrast was evaluated in a feasibility study in 12 adult patients. The notched saturation pulse allowed long magnetization recovery times without sacrificing section coverage. Image contrast between normal and ischemic myocardium was excellent.

Adenosine↗

Bandpass optical flow for tagged MRI.

MR tagging has shown great promise for detailed noninvasive cardiac motion imaging. Our research uses low-frequency tags coupled with gradient-based optical flow estimation to compute cardiac motion. We develop here a novel, fast, fully automated optical flow method for tagged MRI by exploiting the Fourier content of the tagged images. This new method, called bandpass optical flow, works by extracting various subband images from tagged cardiac data, and then formulating multiple optical flow constraints for each subband. The resulting system is solved by least squares pseudo-inversion. The proposed method is validated on simulated and real tagged data.

Algorithms↗

Carcinoma penis.

In the present study 90 cases of carcinoma penis were studied. The disease is more common after the age of 40 years; phimosis was found to be most important predisposing factor. Most common presentation was proliferative lesion with commonest involvement of glans penis. All the cases were of squamous cell carcinoma except one case of malignant melanoma. Clinical determination of lymph node metastasis is falacious as there was discrepancy between clinical and histopathological stage of the disease in 26.67% of cases. Therefore lymph node biopsy at the time of primary surgery is advocated. The result of total amputation is better than other mode of treatment.

Adult↗