Search PubMed⌕ Search

Biomedical subjects

S Morrill

Publications and source records attributed to S Morrill.

4 recordsLinked to original sources

Bi-modality (chemo-radiation) versus tri-modality (chemo-radiation followed by surgery) treatment for carcinoma of the esophagus.

The purpose of the study was to investigate the difference in overall survival in patients with localized carcinoma of esophagus treated using chemo-radiation (bi-modality, BM) or chemo-radiation followed by surgery (tri-modality, TM). From 1981 to 1999, 65 patients were identified who had localized carcinoma of the esophagus treated with either concurrent chemo-radiation (BM, n=22) or concurrent chemo-radiation followed by surgery (TM, n=43) at the University of Texas Medical Branch at Galveston. All 65 patients received concurrent chemotherapy and external beam radiation. Radiation was delivered by linear accelerators (greater-than-or-equal 6 MV), except in one patient who had part of his treatment given by a Co-60 machine. Chemotherapy consisted of 5-fluorouracil and cisplatin plus minus vinblastine under different regimens. Median follow-up time was 10 months (range=1-195 months) for all patients. Of the 14 patients still alive, the median follow-up time was 32 months (range=2-192 months). No difference in overall survival was detected between the two treatment groups, BM vs. TM (P=0.394) despite a selection bias favoring the TM group. Five-year survival rates of the BM and TM groups were 17% and 18%, respectively; 10-year survival rates were 17% and 12%, respectively. The presence of significant past medical history (P=0.017) and a complete pathologic response in the TM group (P < 0.001) were significant independent predictors of survival. We did not find any difference in survival between chemo-radiation or chemo-radiation followed by surgery in patients with localized carcinoma of the esophagus. Use of biologic markers and functional imaging should be explored in order to segregate patients with different tumor biology for treatment using different treatment strategies.

Aged↗

A comparison of mixed integer programming and fast simulated annealing for optimizing beam weights in radiation therapy.

Two competing methods for assigning intensities to radiation treatment beams were tested. One method was derived from mixed integer programming and the other was based on simulated annealing. The methods faced a common objective and identical constraints. The goal was to maximize the minimum tumor dose while keeping the dose in required fractions of normal organ volumes below a threshold for damage. The minimum tumor doses of the two methods were compared when all the dose-volume constraints were satisfied. A mixed integer linear program gave a minimum tumor dose that was at least 1.8 Gy higher than that given by simulated annealing in 7 of 19 trials. The difference was > or = 5.4 Gy in 4 of 19 trials. In no case was the mixed integer solution one fraction size (1.8 Gy) worse than that of simulated annealing. The better solution provided by the mixed integer program allows tumor dose to increase without violating the dose-volume limits of normal tissues.

Abdominal Neoplasms↗

A generic genetic algorithm for generating beam weights.

A genetic algorithm for generating beam weights is described. The algorithm improves an objective measure of the dose distribution while respecting dose volume constraints placed on critical structures. The algorithm was used to select beam weights for treatment of abdominal tumors. Weights were selected for up to 36 beams. Dose volume limits were placed on normal organs and a dose inhomogeneity limit was placed on tumor. Volumes were represented as sets of several hundred discrete points. The algorithm searched for the beam weights that would make the minimum tumor dose as high as the constraints would allow. The results were checked using dose volume histograms with standard sized grids. Nineteen trials were created using six patient cases by changing the required field margin or allowed beam position in each case. The sampling of points was sufficiently dense to yield solutions that strictly satisfied the constraints when the prescribed dose was renormalized by a factor of less than 6%. The genetic algorithm supplied solutions in 49 min on average, and in a maximum time of 87 min. The randomized search does not guarantee optimality, but high tumor doses were obtained. An example is shown for which the solution of the genetic algorithm gave a minimum tumor dose 7 Gy higher than the solution given by a simulated annealing algorithm under the same set of constraints. The genetic algorithm can be generalized to admit nonlinear functions of the beam intensities in the objective or in the constraints. These can include tumor control and normal tissue complication probabilities. The genetic algorithm is an attractive procedure for assigning beam weights in multifield plans. It improves the dose distribution while respecting specified rules for tissue tolerance.

Abdominal Neoplasms↗