Search PubMed⌕ Search

Biomedical subjects

S Marzi

Publications and source records attributed to S Marzi.

4 recordsLinked to original sources

Comparison of dose distributions in IMRT planning using the gamma function.

Intensity-modulated radiotherapy (IMRT) (1) is an advanced form of 3-D conformal radiotherapy. It uses non uniform spatial modifications in the intensity of the beams across the irradiated field. Consequently, it is necessary to develop sophisticated tools to compare measured and calculated dose distributions in order to verify the accuracy of the results of the planned dose distribution. Different methods have been developed to evaluate the accordance between measured and calculated doses, such as the point-to-point dose difference or the evaluation of the distance between two closed points having the same dose value (2-4). The verification method proposed by Low (5-7) seems to be more complete since it takes into account both the dose difference (DD) and the distance to agreement (DTA), allowing to define a "score", the gamma value, at each point of interest. A software tool (DDE: Dose Distribution Evaluator), based on Low's method, to evaluate the agreement between dose distribution matrices has been implemented. In particular, the proposed gamma curve, as a function of the isodose levels, gives real-time information useful for decision making about the treatment plan. The paper describes the software, and reports the obtained results in a simple geometry and in several clinical cases (head-neck and prostate). Comparison between measured data (film and MapCheck) and calculated data (CadPlan) using DDE has shown very good agreements. Thanks to its higher resolution, film dosimetry showed better accuracy than the MapCheck technique. Similar results can be obtained also with the MapCheck technique when proper measurement methods are used.

Dose-Response Relationship, Radiation↗

[Hematochezia].

Explore the source record for details and available documents.

Adult↗

MRS study of the interaction of dihydropyridines with lipid molecules in phosphatidylcholine vesicles.

Dihydropyridines (DHPs), synthetic molecules used as antihypertensive agents, bind to plasma membrane receptors following diffusion through the hydrophobic phase. In this study, MRS technique has been used to clarify the interactions of the dihydrophyridines Nifedipine and Lacidipine within the lipid bilayer. 1D and 2D 1H MRS at high field have been employed to examine the behavior of unilamellar dimyristoyl-phosphatidylcholine liposomes when the two drugs have been inserted in the bilayer. In particular, the study represents an innovative application of 2D 1H NOESY technique to clarify different mechanisms of interactions of small molecules inside model membranes. On the other hand, 31P measurements have been performed in multilamellar dimyristoyl-phosphatidylcholine lipsomes to detect alterations of lipid polymorphic phases. The experiments show that the two dihydropyridines interact with the lipids by different modalities. Lacidipine undergoes a very strong interaction with lipids, possibly inducing a phase segregation of lipid molecules into the bilayer, while self-association seems to be the prevalent interaction of Nifedipine inside the bilayer.

Dihydropyridines↗

Optimization of intensity modulated radiation therapy: assessing the complexity of the problem.

Intensity modulated radiation therapy (IMRT) is one of the most innovative techniques in oncological radiotherapy, allowing to conform the dose delivery to the tumoral target, preserving the normal tissue. The high number of parameters involved in the IMRT treatment planning requires an automated approach to the beam modulation. Such optimization process consists in the search of the global minimum of a cost function representing a quality index for the treatment. The complexity of this task, has been analyzed with a statistical approach for three clinical cases of particular interest in IMRT. Our main result is that a cost function based on dose-volume constraints entails lower complexity of the optimization process, in terms of the choice of the parameters defining the cost function and in a smaller sensitivity to the initial conditions for the optimization algorithm.

Radiotherapy Dosage↗