Search PubMed⌕ Search

Biomedical subjects

S Maharajan

Publications and source records attributed to S Maharajan.

5 recordsLinked to original sources

Choroidal detachment in perforated corneal ulcers: frequency and management.

AIMS: To determine the frequency of choroidal detachment (CD) in eyes with non-traumatic corneal ulcer perforation and, also, to assess the efficacy and safety of cyanoacrylate glue in sealing corneal perforations. METHODS: 18 eyes of 17 patients were studied. Inclusion criterion was any patient with a non-traumatic perforated corneal ulcer. All patients had a thorough history taken and complete ophthalmic examination including B-scan ultrasonography. Patient demographics, presence of CD, and efficacy of corneal gluing were assessed. RESULTS: Eight of the 18 eyes (44%) were documented to have a CD. Among perforations of >2 mm2, six eyes (75%) were documented to have CD compared with two eyes (20%) with perforations of <or=2 mm2 (p = 0.054). No correlation could be determined between perforation duration and incidence of CD. Of the 15 eyes that underwent gluing, there were 13 successes (87%) and two failures (13%). Within the successes four patients (27%) required re-gluing because of infection (one patient) or progression of melt and glue loosening (three patients). Failure was the result of severe progression of melting (one patient) and a very large perforation (one patient). CONCLUSION: Choroidal detachment following corneal ulcer perforation is common and is more likely in larger corneal perforations. Preoperative B-scan should be considered in cases of large corneal perforations requiring therapeutic keratoplasty to document choroidal detachment, which if large may require drainage. Cyanoacrylate glue is an effective and safe method for sealing small corneal perforations. A vigil must be maintained for infection while the glue and bandage contact lens are in situ.

Aged↗

Management options for the flat corneal graft.

The post-penetrating keratoplasty (PK) corneal profile may be unpredictable and visual rehabilitation can be difficult. A case series of 11 such patients with flat corneal topography is presented and their management described. Suture removal may not provide a sufficient re-modelling effect to restore convexity of the cornea to enable satisfactory contact lens fitting and reverse geometry (RG) lenses have an important role.

Journal Article↗

Streptococcus pneumoniae from ophthalmic infections: serotype distribution and penicillin susceptibility.

Streptococcus pneumoniae is one of the pathogens causing infection of the conjunctiva and the uveal tract. The present study began with the observation of two ophthalmic S. pneumoniae isolates showing intermediate resistance to penicillin. Among the 25 isolates of S. pneumoniae from 617 ophthalmic specimens, during the period of 14 months, four were found to exhibit an intermediate resistance to penicillin. Minimum Inhibitory Concentration values ranging from 0.125 microg/mL to 0.25 microg/mL was observed. No multidrug resistant strains were isolated. Serogrouping/typing of the S. pneumoniae revealed the following serogroups/types; 6A (n = 3), 6B (n = 2), 22 (n = 3), 14 (n = 3), 23A (n = 2), and 1 each of 23B, 19A, 7B, 32, 9, 42, 21, 39, 10, 3, and 34. One strain showed cross reaction in pool 29, 35, and 47. These findings represent the first such observation of ophthalmic isolates from India.

Anti-Bacterial Agents↗

VISTECH contrast sensitivity testing in primary open angle glaucoma.

Contrast sensitivity has been recommended as a screening and diagnostic test in primary open angle glaucoma (POAG). We tested contrast sensitivity (CS) using Vistech charts in 184 eyes of 95 patients. Three groups were examined--established primary open angle glaucoma, glaucoma suspects and age matched controls. The distribution of contrast sensitivities amongst the three groups were similar. The median contrast sensitivity of glaucoma suspects and controls were well within normal limits while that of the POAG group fell along the lower limit of normal. In all three groups the younger subjects scored better than the older, indicating a depression of contrast sensitivity with increasing age. Even if depression of any one spatial frequency was considered abnormal, the test yielded a sensitivity of 55.4% and specificity of 69.5%. Similarly contrast sensitivity testing was found to be of little use in detecting field defects a maximum sensitivity of 47.3% and specificity of 73.3%. Vistech contrast sensitivity testing is not a useful test in POAG screening or diagnosis.

Adult↗