Search PubMed⌕ Search

Biomedical subjects

S M Stover

Publications and source records attributed to S M Stover.

99 records · Page 6Linked to original sources

Corticocancellous bone biopsy from the 12th rib of standing horses.

Unicortical corticocancellous bone biopsy specimens 4.5 mm and 6.5 mm in diameter were obtained without long-term complications from the 12th rib in eight standing horses. However, the bone specimens were unsuitable for histologic or histomorphometric evaluation. In in vitro comparisons of biopsy specimens 6.5 mm and 12 mm in diameter, and of unicortical and transcortical biopsy specimens, 12 mm transcortical specimens yielded the most cancellous bone. Transcortical bone biopsy specimens 12 mm in diameter were obtained from eight horses by using power-assisted trephination. The surgical procedure was well tolerated, but some degree of pneumothorax in all horses was treated by aspiration of air from the thorax. Long-term complications were not observed.

Animals↗

An in vitro biomechanical investigation of an interlocking nail for fixation of diaphyseal tibial fractures in adult horses.

The compressive, bending and torsional mechanical properties of osteotomized adult equine tibiae stabilized with an interlocking intramedullary nail (nail-tibia composite) were compared with those of intact tibiae to determine the clinical applicability of the the nail for repair of tibial fractures in adult horses. The mean yield load, failure load, and stiffness for the nail-tibia composites were significantly less (P < .05) than those for the intact tibiae in all loading configurations. The mean compressive yield load for the nail-tibia composites was greater than the compressive load calculated from previously reported in vivo data for walking and trotting, and was equal to the load calculated for recovery from anesthesia. The mean yield bending moment for the nail-tibia composites was greater than the bending moment previously calculated for standing, walking, and recovery from anesthesia. The mean torsional yield load for the nail-tibia composites was less than the torsional load determined for the walk from another in vivo study. The design of the interlocking nail evaluated in the present study should be modified to increase torsional and compressive yield strengths and torsional stiffness before reasonable success could be expected for the treatment of adult equine tibial fractures.

Animals↗

The effect of hole diameter on the torsional mechanical properties of the equine third metacarpal bone.

The torsional monotonic structural material properties of equine metacarpi with or without, either a 5/16 inch or 3/8 inch diameter bicortical lateromedial middiaphyseal hole were assessed to determine the effect of a hole on metacarpal strength. Torsional stiffness was not significantly effected by the presence of a bicortical hole, whereas yield and failure angles, torques and energies of metacarpi with a hole were 51% to 97% of those of intact bones. Significant differences were not apparent for yield and failure mechanical properties between metacarpi with a 5/16 inch diameter hole and metacarpi with a 3/8 inch diameter hole; however, postyield mechanical properties were lower for metacarpi with a 3/8 inch hole. Whereas some metacarpi with a 5/16 inch hole were capable of plastic deformation before failure, metacarpi with a 3/8 inch diameter hole appeared to have sufficient stress concentration to propagate complete fracture on structural yield.

Animals↗

An in vitro biomechanical investigation of the mechanical properties of dynamic compression plated osteotomized adult equine tibiae.

OBJECTIVE: To determine the monotonic mechanical properties of osteotomized adult equine tibiae stabilized with two dynamic compression plates (DCP) and to compare the mechanical properties with those of intact tibiae and in vivo loads. STUDY DESIGN: The compressive, bending, and torsional mechanical properties of plated and intact tibiae were assessed in vitro. ANIMALS OR SAMPLE POPULATION: Twelve pairs of adult equine tibiae. METHODS: Tibiae were loaded in axial compression, craniocaudal 3-point bending, or torsion in external rotation in a single cycle to failure. Mechanical properties were determined from load-displacement data. RESULTS: Compared to intact tibiae, the mean yield load, failure load and stiffness of plated tibiae were significantly lower (P < .05) (compression and torsion); and the mean yield and failure bending moments, and bending stiffness, of the plated tibiae were lower (P < .075 for yield), or significantly lower, respectively. The mean compression and bending yield loads for plated tibiae were greater than in vivo loads. The mean torsional yield load for plated tibiae approximated the torsional load determined for the adult horse at a walk. CONCLUSIONS: Simple, anatomically reduced, DCP plated tibiae should have adequate strength to withstand immediate, postoperative in vivo compressive loads and bending moments placed on the tibia in vivo during immediate postoperative activities, however, may not have adequate torsional strength during immediate postoperative weight-bearing at a walk. CLINICAL RELEVANCE: Additional supportive methods, to decrease torsional loads, may be beneficial in maintaining stability of plate repaired tibiae during recovery from anesthesia and postoperative healing.

Animals↗

An in vitro biomechanical investigation of an equine interlocking nail.

OBJECTIVE: To determine the mechanical properties of Equine Interlocking Nail (EIN; JD Wheat Veterinary Orthopedic Research Laboratory, University of California, Davis) stabilized osteotomized tibiae and compare these variables with estimated in vivo loads. STUDY DESIGN: In vitro biomechanical investigation. ANIMALS: Twelve adult equine cadaveric tibiae. SAMPLE POPULATION: EIN-stabilized tibiae were tested monotonically under compression, 3- and 4-point bending, and torsion. Mechanical properties were compared with estimated in vivo loads. RESULTS: EIN-tibial composite mean compressive yield load (11 kN) and bending moment (216 Nm) were greater than loads expected postoperatively in vivo; however, the mean torsional yield load (156 Nm) was less than that expected in vivo. CONCLUSIONS: EIN-stabilized tibiae had compressive and bending strengths greater than those expected to maintain stability during walking in adult horses. Torsional yield strength did not appear sufficient to provide stability during walking in vivo. CLINICAL RELEVANCE: The EIN is not a feasible method of fracture repair for adult equine tibial fractures at this time, because its mechanical properties appear inadequate to withstand the postoperative torsional loads encountered during walking. Because this method of fracture repair may offer biological advantages, further modification of an interlocking nail for adult horses appears warranted.

Animals↗

A biomechanical comparison of double-plate and Y-plate fixation for comminuted equine second phalangeal fractures.

OBJECTIVES: To compare the biomechanical properties, in full limb preparations, of intact second phalanx and a simulated comminuted second phalangeal fracture stabilized with either two bone plates or a custom Y-plate. STUDY DESIGN: In vitro biomechanical assessment of intact limbs and of paired limbs with a simulated second phalangeal fracture stabilized by one of two fixation methods. Animal Population-Thirteen pairs of equine cadaveric forelimbs. METHODS: A comminuted second phalangeal fracture was created in six paired cadaveric limbs. For each limb pair, the fracture was stabilized with two plates in one limb, and with a Y-plate in the contralateral limb. These limbs and seven pairs of intact limbs were subjected to axial compression in a single cycle until failure. Mechanical properties were compared with a mixed-model ANOVA and post hoc contrasts. Joint contact pressure, screw insertion torque, and final screw torque remaining after mechanical testing were also evaluated for constructs. RESULTS: No significant differences in mechanical testing variables were detected between construct types. However, the Y-Plate construct had significantly greater yield load, yield displacement and yield energy, and failure load and stiffness values than those for intact specimens, whereas the double-plate construct only had greater stiffness than intact specimens. There were no significant differences in joint contact pressures for both constructs. The final screw torque for proximal phalangeal screws was significantly greater for the Y-plate constructs than for double-plate constructs. CONCLUSIONS: The Y-plate was as effective as the double-plate technique for stabilization of simulated comminuted second phalangeal fractures in monotonically tested equine cadaveric forelimbs. CLINICAL RELEVANCE: This investigation supports evaluation of the Y-plate for repair of comminuted second phalangeal fractures in equine patients. Its specific design may facilitate repair of second phalangeal fractures, and may provide increased stability by allowing the proximal fragments of the second phalanx to be fixed with three screws placed through the plate.

Analysis of Variance↗

In vitro cyclic biomechanical properties of an interlocking equine tibial nail.

OBJECTIVE: To determine cyclic biomechanical properties of gap osteotomized adult equine tibiae stabilized with an equine interlocking nail (EIN). STUDY DESIGN: In vitro experimental biomechanical investigation. SAMPLE POPULATION: Thirteen adult equine cadaveric tibiae. METHODS: Adult equine tibiae with transverse, midshaft, 1-cm gap osteotomies, stabilized with an equine interlocking nail, underwent cyclic biomechanical testing in vitro under axial compression, 4-point bending, and torsion. Different specimens were subjected to different load levels that represented estimated in vivo loads at 2 Hz for 740,000 cycles. Fatigue life and gap strain were calculated. RESULTS: Compression and bending, but not torsional, fatigue life were longer than time necessary for bone healing. Compressive, but not bending or torsional, gap strains were small enough to be compatible with fracture healing by primary bone formation. Gap strains for compressive, bending, and torsional loads were compatible with indirect, or secondary, bone formation. CONCLUSIONS: Further modification should be made to the equine interlocking nail to increase bending stiffness and torsional fatigue life. CLINICAL RELEVANCE: The stainless steel equine intramedullary interlocking nail is unlikely to provide appropriate long-term stability for fracture healing in adult equine tibiae without modifications in the nail design and material.

Animals↗

Femoral fractures in a young male Turkey breeder flock.

Twenty-two 32-to-35-wk-old male turkeys from a commercial breeding flock were presented to the California Veterinary Diagnostic Laboratory System, Fresno Branch, with a clinical complaint of lameness and increased mortality. Necropsy findings included a unilateral, closed oblique fracture involving the femur in 12 birds. Ten complete femoral fractures had periosteal new bone adjacent to and bridging the fracture. Periosteal callus formation, in this case, suggested that preexisting lesions preceded complete fracture of the femur. Factors such as selection for heavy body weight, lack of exercise, and handling might have contributed to the development and promotion of complete fractures.

Animal Husbandry↗

Subchondral bone failure in overload arthrosis: a scanning electron microscopic study in horses.

Mechanical overload leads to a common arthrosis in the metacarpal condyle of the fetlock joint of racehorses. This is usually asymptomatic but severe forms can cause lameness. Subchondral bone failure is often present and the predictability of the site provided an opportunity to study of the progression of bone failure from microcracks to actual collapse of subchondral bone. Twenty-five fetlock condyles from racehorses with various stages of disease were selected. Stages ranged from mild through severe subchondral bone sclerosis, to the collapse of bone and indentation or loss of cartilage known as 'traumatic osteochondrosis'. Parasagittal slices were radiographed and examined with scanning electron microscopy. Fine matrix cracks were seen in the subchondral bone layer above the calcified cartilage and suggested loss of water or other non-collagenous components. The earliest microcracks appeared to develop in the sclerotic bone within 1-3 mm of the calcified cartilage layer and extend parallel to it in irregular branching lines. Longer cracks or microfractures appeared to develop gaps as fragmentation occurred along the margins. Occasional osteoclastic resorption sites along the fracture lines indicated activated remodeling may have caused previous weakening. In one sample, smoothly ground fragments were found in a fracture gap. Bone collapse occurred when there was compaction of the fragmented matrix along the microfracture. Bone collapse and fracture lines through the calcified cartilage were associated with indentation of articular cartilage at the site.

Animals↗