Search PubMed⌕ Search

Biomedical subjects

S M Shnider

Publications and source records attributed to S M Shnider.

At least 37 records · Page 2Linked to original sources

Bupivacaine-induced cardiac arrhythmias in sheep.

Controversy persists about the cardiac toxicity of bupivacaine if accidentally administered intravenously during regional anesthesia. Using awake, unanesthetized sheep, we evaluated the cardiac effects of low and high equivalent doses of lidocaine and bupivacaine given intravenously over 10 s. All animals convulsed within 30 s of injections. Although both drugs significantly increased heart rate and systemic and pulmonary arterial blood pressure for up to 10 min, cardiac output was affected variably. The magnitude of hemodynamic changes that each drug produced did not differ significantly from each other at either dose level. However, of the sheep receiving intravenous lidocaine, none developed arrhythmias other than mild sinus tachycardia and minimal ST-T wave changes (which occurred in 25% of the animals). After intravenous bupivacaine injection, all sheep had transient changes on the EKG and/or arrhythmias (e.g., supraventricular tachycardia; atrioventricular condition blocks; ventricular tachycardia; multiform premature ventricular contractions; wide QRS complexes; ST-T wave changes; and in one animal, fatal ventricular fibrillation). Normal sinus rhythm usually returned within 8-10 min. Arterial blood gas and acid-base values stayed within the normal range during the studies, and serum potassium did not change significantly from control. In conclusion, in conscious adult sheep, equivalent doses of lidocaine or bupivacaine produced similar central nervous system (CNS) toxicity when rapidly injected intravenously. In the absence of marked hypoxia, respiratory or metabolic acidosis, hyperkalemia, or hypotension, serious cardiac arrhythmias occurred after bupivacaine but not lidocaine.

Animals↗

Pharmacokinetics, placental transfer, and neonatal effects of vecuronium and pancuronium administered during cesarean section.

Vecuronium and pancuronium were compared for placental transfer, pharmacokinetic variables, and neonatal effects during cesarean section under general anesthesia. Eighteen women underwent rapid-sequence intravenous induction using d-tubocurarine, succinylcholine, thiopental, and oxygen. Immediately after tracheal intubation, an intravenous injection of vecuronium (n = 11) or pancuronium (n = 7), 0.04 mg/kg, was given. Maternal venous blood samples were obtained before induction and at frequent intervals for 4 h after administration of vecuronium or pancuronium. Also, maternal venous and umbilical-cord arterial and venous blood samples were obtained at delivery. To describe placental transfer and maternal pharmacokinetics of the drugs, serum drug concentrations were determined using single-ion-monitoring mass spectrometry. The Apgar score and Neurologic and Adaptive Capacity Score (NACS) were used to evaluate neonatal condition. Both drugs crossed the placenta, as demonstrated by low concentrations of vecuronium (8.5-26.4 ng/ml) or pancuronium (12.2-34.2 ng/ml) found in umbilical venous blood. At delivery, the ratio of the drug concentration in umbilical venous blood to that in maternal venous blood was 0.11 +/- 0.02 for vecuronium and 0.19 +/- 0.03 for pancuronium. Vecuronium had a more rapid clearance (6.4 +/- 0.4 ml X kg-1 X min-1, mean +/- SE) and a shorter elimination half-life (36 +/- 1.8 min) than pancuronium (3.0 +/- 0.1 ml X kg-1 X min-1 and 72 +/- 6 min, respectively). No other pharmacokinetic differences were found between the drugs. Neonatal outcome was not affected adversely by either muscle relaxant, as assessed by Apgar scores and NACSs . The short duration of action, the minimal placental transfer, and the apparent lack of clinical neuromuscular effects on the newborn suggest that vecuronium should be a useful muscle relaxant for cesarean section.

Adult↗

Hyperbaric intrathecal morphine analgesia during labor in a patient with Wolff-Parkinson-White syndrome.

The Wolff-Parkinson-White syndrome can complicate the anesthetic management of the pregnant patient. These patients are prone to arrhythmia that can be accompanied by hypotension. Maintenance of a stable heart rhythm is necessary for both maternal and fetal well-being. An optimal anesthetic regimen that provides minimal cardiac and hemodynamic changes has not been determined. Intrathecal administration of opiates for obstetric analgesia has been found to provide hemodynamic stability because no motor or sympathetic blockade occurs. The authors report the successful use of intrathecal injection of morphine for labor analgesia in a patient with Wolff-Parkinson-White syndrome.

Adult↗

Efficacy of clear antacid prophylaxis in obstetrics.

We studied 33 women scheduled to undergo general anesthesia for cesarean section. Prior to induction of anesthesia, each patient received in a random fashion one of two prophylactic antacids. Group I (n = 17) received 30 ml Gelusil orally and Group II (n = 16) received 30 ml of 0.3 mol/l sodium citrate. After induction of general anesthesia an oro-gastric tube was passed. The amount and pH of the gastric aspirate were measured at the time of delivery and 45 min after delivery "before extubation." Both antacids elevated gastric pH above 3.5 in all patients but one in the Gelusil group. The pH remained elevated 45 min later. It is concluded that 0.3 mol/l sodium citrate is effective as an antacid when given orally prior to induction of anesthesia.

Adult↗

Epidural morphine analgesia after cesarean delivery.

The effectiveness and safety of 5 mg of epidurally administered morphine for postoperative analgesia was determined in 276 healthy women undergoing cesarean delivery. Overall pain relief, time to administration of additional analgesic medications, and adverse side effects were evaluated. Epidural injection of 5 mg of morphine provided good to excellent pain relief lasting 24 to 36 hours for 83% of patients. Also, review of hospital records for a subset of 34 patients revealed that requirements for additional systemic analgesics were markedly less when postoperative pain relief was provided by epidural administration of morphine than by conventional analgesia therapy. Pruritus, nausea, and vomiting occurred frequently, but were easily treated. Although late respiratory depression did not occur in this group, the authors continue to observe patients closely and monitor respiratory rates for 24 hours.

Cesarean Section↗

Maternal and neonatal effects of epidural morphine for labor and delivery.

To determine the efficacy of epidural morphine during labor and delivery, 40 healthy parturients who requested epidural analgesia were randomly given either a single injection of morphine sulfate (2 mg, n = 9; 5 mg, n = 10; or 7.5 mg, n = 11) or 0.5% bupivacaine (n = 10). Bupivacaine provided excellent analgesia in all patients. Morphine (2 or 5 mg) did not produce adequate analgesia and needed to be supplemented by local anesthesia. Morphine (7.5 mg) gave satisfactory analgesia in 7 of 11 patients until the end of the first stage of labor, and, in an additional patient, for almost 13 hr, at which time cephalopelvic disproportion was diagnosed. In all patients given epidural morphine, local anesthesia was needed for the second stage of labor if instrumentation or episiotomy was required. The only side effect was pruritus, which occurred in three patients. Epidural morphine did not produce neonatal depression, as evidenced by Apgar scores and neurologic and adaptive capacity scores. We conclude that 7.5 mg of epidural morphine can give satisfactory pain relief during labor but not delivery, and that 2 or 5 mg of morphine is ineffective. Although 0.5% bupivacaine provided better anesthesia, epidural morphine might prove useful for selected patients.

Acid-Base Equilibrium↗

Maternal catecholamines decrease during labor after lumbar epidural anesthesia.

To determine whether epidural anesthesia during labor affects maternal circulating catecholamines, blood samples were obtained from 15 patients at the peak of and immediately after two consecutive painful contractions. A lumbar epidural local anesthetic without epinephrine was then administered. After the onset of analgesia, four blood samples were again drawn. All samples were analyzed by a radioenzymatic assay for epinephrine and norepinephrine concentrations. Before anesthesia, the mean (+/-SEM) plasma epinephrine level was 280 +/- 49 pg/ml, and the mean norepinephrine level was 866 +/- 122 pg/ml. After anesthesia, epinephrine levels decreased 56% (p less than 0.01). Although norepinephrine levels decreased approximately 19%, this reduction was not statistically significant. At the height of a contraction, catecholamine levels did not differ significantly from those occurring between contractions. Lumbar epidural anesthesia during labor reduces maternal epinephrine levels, probably by eliminating the psychological and physical stress associated with painful uterine contractions or by denervating the adrenal medulla. Whatever the mechanism, reducing pain and activity of the sympathetic nervous system should increase uterine blood flow.

Anesthesia, Epidural↗

Epidural morphine for the relief of postoperative pain after cesarean delivery.

To determine the safety, efficacy, and dose response of epidurally administered morphine for analgesia after cesarean delivery, 40 healthy women who underwent cesarean delivery with epidural anesthesia were randomly assigned to receive one of four regimens for relief of postoperative pain: intramuscular administration of morphine, 7.5 mg (N = 10); or epidural administration of morphine, 2 mg (N = 10), 5 mg (N = 10), or 7.5 mg (N = 10). Evaluations were made of intensity and relief of pain, time to administration of additional analgesic medications, changes in vital signs and blood-gas tensions, and adverse effects. Intramuscular administration of 7.5 mg of morphine effectively relieved pain for only a short time. When morphine was administered epidurally, 2 mg proved ineffective whereas both 5 mg and 7.5 mg provided substantial pain relief for approximately 24 h. There were no significant changes in vital signs or blood-gas tensions. Side effects included pruritus and nausea, which occurred frequently but were usually mild and easily treated. We concluded that either 5 mg or 7.5 mg of morphine epidurally administered was effective and safe in providing prolonged analgesia after cesarean delivery.

Adult↗

Evaluation of neurotoxicity after subarachnoid injection of large volumes of local anesthetic solutions.

Recent case reports describing prolonged neurologic deficit after accidental spinal anesthesia with large volumes of 2-chloroprocaine have led to the suggestion that chloroprocaine may be more likely to cause such complications than other local anesthetics. We evaluated the neurologic effects of lumbar puncture alone and of large-volume subarachnoid administration of 2-chloroprocaine (3%), bupivacaine (0.75%), lidocaine (2%), Elliott's solution B (which is similar to CSF), or the carrier solution of 2-chloroprocaine (Nesacaine) in 48 sheep and 8 monkeys. Cerebrospinal fluid of sheep was collected on days 1 and 7 for biochemical and biological analyses, and CSF pressures of monkeys were recorded before and after injection. Animals were observed for neurologic deficits for seven days. Twelve sheep were unable to stand. Monkeys, on the other hand, had no apparent neurologic deficits. Autopsies revealed that 5 of the 12 sheep had lumbar subpial demyelination with macrophage infiltration: two of the five had received lidocaine; two received 2-chloroprocaine; and one had only a lumbar puncture. Two other sheep also had subpial demyelination: one had received lidocaine and one received 2-chloroprocaine. Three of the eight monkeys had lumbar subpial demyelination with macrophage invasion; two had received bupivacaine, and one received 2-chloroprocaine. No solution produced significant abnormalities in sheep CSF composition. We conclude that no local anesthetic or solution was more neurotoxic than another when injected in large volumes into the subarachnoid space of sheep or monkeys.

Anesthesia, Epidural↗

A new neurologic and adaptive capacity scoring system for evaluating obstetric medications in full-term newborns.

A variety of examinations are currently available for evaluating the neurobehavior of the newborn. These exams are often difficult and time-consuming to perform, require extensive training of the examiners, and produce results that may be difficult to interpret. The authors describe a new Neurologic and Adaptive Capacity Score (NACS) for full-term neonates and compare it with the Scanlon Early Neonatal Neurobehavioral Scale (ENNS), the most widely used test for evaluating effects of obstetric medication on the neonate. The NACS was designed as a screening test to detect central nervous system depression from drugs and also to differentiate these effects from those found after birth trauma and perinatal asphyxia. The NACS is based on 20 criteria, each of which is given a score of 0, 1, or 2. These criteria assess five general areas: 1) adaptive capacity; 2) passive tone; 3) active tone; 4) primary reflexes; and 5) alertness, crying, and motor activity (general observations). In contrast to the ENNS, the NACS places more emphasis on motor tone, avoids the use of noxious stimuli (pinprick, repeated Moro examinations), takes half the time to perform, and provides for any given baby a single number that immediately identifies a depressed or vigorous neonate.

Adaptation, Physiological↗

Choice of anesthesia for labor and delivery.

Skillful administration of a well-chosen anesthetic can ease the birth process for the mother, and can possibly prevent such signs of stress in the fetus as bradycardia and asphyxia, which are caused by uterine vasoconstriction. The survey summarizes current knowledge of physiologic changes in pulmonary, cardiac, renal, and other functions during pregnancy and childbirth and the ways in which anesthesia may affect them. Indications and contraindications for the use of various types of anesthesia in normal and complicated deliveries are discussed, as are ways to prevent or minimize adverse reactions in mother and child. This summary facilitates the practicing obstetrician's understanding of the techniques, advantages, and problems involved with obstetric anesthesia and analgesia.

Analgesia↗

Enflurane analgesia in obstetrics.

The effects of enflurane analgesia (approximately 0.5%) were studied in 55 patients during the second stage of normal vaginal delivery and were compared with effects of nitrous oxide (approximately 40%) in 50 similar patients. The enflurane and oxygen mixture was rated satisfactory by 89% of the mothers and 80% of the anesthesiologists. These ratings did not differ significantly from those for nitrous oxide. Obstetricians, however, rated the enflurane and oxygen mixture superior. The newborns of mothers receiving both agents wee vigorous and comparable when assessed by Apgar scores and cord blood gas tensions. The estimate of blood loss was similar in both groups. Serum inorganic fluoride concentrations in the mother after anesthesia were not significantly increased from preanesthetic levels with either agent. There was no biochemical evidence of renal toxicity. In neonates of mothers given enflurane, the mean umbilical cord concentration of serum inorganic fluoride ions was 2.4 +/- 0.2 micromoles/L, a value well below that associated with nephrotoxicity.

Adult↗

The effect of maternal administration of ephedrine on fetal heart rate and variability.

Ephedrine is the most popular vasopressor used in obstetrics to prevent or treat spinal or epidural hypotension. Fetal heart rate (FHR) changes during epidural anesthesia were studied in 71 patients; it was found that ephedrine administration (57 patients) was associated with significant increases in FHR and beat-to-beat variability. These changes were dose related and were not associated with fetal asphyxia as judged by measurement of fetal scalp blood pH or Apgar scores.

Anesthesia, Obstetrical↗

Uterine blood flow and plasma norepinephrine changes during maternal stress in the pregnant ewe.

Because maternal stress may adversely affect the fetus, the authors tested the effects of brief episodes (15-60 sec) of maternal stress in 18 awake pregnant ewes. Maternal agitation and stuggling occurred either following non-painful stimuli such as loud noises or sudden movements of personnel (ten animals) or following the brief application of the ewe's skin of a uniform electrical stimulus of 30 volts with a frequency of 167 Hz for 30-60 sec (eight animals). Stimulation of either type produced a 45-50 per cent increase in mean maternal arterial blood pressure and a concomitant 32-52 per cent decrease in uterine blood flow (P less than 0.05). The decreases in uterine blood flow were brief, lasting less than 3 min, and were not associated with fetal asphyxia. Maternal plasma norepinephrine levels were measured following electrically induced maternal stress and were increased 25 per cent. The authors conclude that maternal stress may decrease uterine blood flow secondary to release of endogenous norepinephrine.

Acid-Base Equilibrium↗

Dopamine treatment of spinal hypotension decreases uterine blood flow in the pregnant ewe.

In seven pregnant ewes, 3--5 min of hypotension resulting from spinal anesthesia decreased uterine blood flow 17 per cent. Dopamine, in doses sufficient to maintain blood pressure at control values (20--40 micrgram/kg/min) for 3--5 min, further decreased uterine blood flow to 56 per cent less than control and increased uterine vascular resistance to 50 per cent more than control. Following 30 min of hypotension, 30 min of dopamine administration in doses sufficient to restore blood pressure to control values (5--20 microgram/kg/min) similarly decreased uterine blood flow to 29 per cent less than control and increased uterine vascular resistance to 35 per cent more than control.

Anesthesia, Spinal↗

Anaesthetic considerations in caesarean section for quadruplets.

A case of a caesarean delivery with epidural analgesia of a term parturient with quadruplets is presented. Maternal considerations of hypotension, respiratory embarrassment and aspiration of gastric content and foetal considerations of prematurity and impaired placental function are discussed relative to the use of general anaesthesia or epidural analgesia.

Adult↗