Search PubMed⌕ Search

Biomedical subjects

S M Seltzer

Publications and source records attributed to S M Seltzer.

At least 19 recordsLinked to original sources

Monte Carlo calculations of the dose distribution in teeth due to internal exposure from 90Sr: application to EPR tooth dosimetry.

This paper addresses issues in the application of the electron paramagnetic resonance (EPR) retrospective dosimetry with dental tissues exposed by radionuclides accumulated in the dentin. A simple dosimetric model of a tooth incorporating 90Sr is presented. The tooth is modelled as two concentric cylinders: the inner cylinder composed of dentin, and the outer cylindrical shell of enamel. Extensive Monte Carlo calculations were done to obtain the distributions of absorbed dose in dentin and enamel for teeth of different sizes. The results were used to calculate the mean absorbed doses in enamel that are directly measurable by EPR. A relationship between such measured doses and the specific activity of 90Sr in dentin was derived based on a simple model of 90Sr accumulation. The roles of different tooth tissues as dose detectors are analysed, and the importance of dentin as a dosimetric material for internal exposure is pointed out.

Absorption↗

Correction factors in the EPR dose reconstruction for residents of the Middle and Lower Techa riverside.

During 1949-1956, the first Soviet nuclear weapons plant, Mayak, released about 7.6 x 10(7) m(-3) of liquid radioactive waste with a total activity of 10(17) Bq into the Techa River (Southern Urals, Russia). 90Sr contributed 11.6% to the total waste radioactivity. As a result of these radioactive discharges, about 28,000 local residents were exposed to ionizing radiation, and some of them received relatively high doses. Internal exposure of the population residing at the Middle and Lower Techa riverside was mostly from 90Sr deposited in bone and tooth tissues. In order to reconstruct radiation doses to this population group, a study of 35 teeth extracted from local residents was carried out using electron paramagnetic resonance measurements. A total of 73 samples from these 35 teeth (tooth enamel, 33; crown dentin, 20; and root dentin, 20) were prepared and measured with electron paramagnetic resonance. The study revealed high doses (up to 15 Gy) absorbed in tooth enamel of the individuals born during 1945-1949, which was attributed to very high local 90Sr concentration in tooth enamel of this particular age group in the population. The analysis presented here takes into account (a) the time courses both of the release/intake of 90Sr and of the tooth formation, and (b) expected variations in measured absorbed doses due to differing geometric sizes of tooth structures. This methodology enables a more consistent picture to be developed of the 90Sr intake by the Middle and Lower Techa riverside population, based on electron paramagnetic resonance tooth dosimetry.

Age Factors↗

AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology.

The American Association of Physicists in Medicine (AAPM) presents a new protocol, developed by the Radiation Therapy Committee Task Group 61, for reference dosimetry of low- and medium-energy x rays for radiotherapy and radiobiology (40 kV < or = tube potential < or = 300 kV). It is based on ionization chambers calibrated in air in terms of air kerma. If the point of interest is at or close to the surface, one unified approach over the entire energy range shall be used to determine absorbed dose to water at the surface of a water phantom based on an in-air measurement (the "in-air" method). If the point of interest is at a depth, an in-water measurement at a depth of 2 cm shall be used for tube potentials > or = 100 kV (the "in-phantom" method). The in-phantom method is not recommended for tube potentials < 100 kV. Guidelines are provided to determine the dose at other points in water and the dose at the surface of other biological materials of interest. The protocol is based on an up-to-date data set of basic dosimetry parameters, which produce consistent dose values for the two methods recommended. Estimates of uncertainties on the final dose values are also presented.

Air↗

Dosimetry characterization of 32P catheter-based vascular brachytherapy source wire.

Dosimetry measurements and Monte Carlo simulations for a catheter-based 32P endovascular brachytherapy source wire are described. The measured dose rates were obtained using both radiochromic dye film and an automated plastic scintillator. The investigated source has dimensions of 27 mm in length and 0.24 mm in diameter, and is encapsulated in NiTi. For the radiochromic film measurements, calibrated radiochromic dye film was irradiated at distances between 1 and 5 mm from the source axis in A-150 plastic, and read out with a high-resolution scanning densitometer. The depth-dose curve measured in A-150 is then converted to that in water using correction factors obtained from Monte Carlo calculations. For the scintillator system, direct measurements in water were acquired at distances between 1 and 6 mm from the center of the source, along the perpendicular bisector of the source axis. The scintillator was calibrated in terms of absorbed-dose rate in a reference beta-particle field at multiple depths. The measured dose rates obtained from the film and scintillator measurements were then normalized to the measured source activity, i.e., to convert the measured data to units of cGy/s/mCi. Theoretical dosimetry calculations of the catheter-based 32P wire geometry were also obtained from Monte Carlo simulations using the Electron Gamma Shower code (EGS4), the Monte Carlo N-particle transport code (MCNP4B), and CYLTRAN from the Integrated Tiger Series codes (ITS v.3) and found to be in good agreement. The results of both measurements and calculations are expressed as absorbed-dose rate in water per unit of contained activity (cGy/s/mCi). Comparisons indicate that the measured and calculated dosimetry are in good agreement (<10%) within the relevant treatment distances (1-5 mm). This work fully characterizes the radiation field around a novel 32P beta brachytherapy source in water. The depth-dose curve can be used to calculate the dose to the vessel wall from a 27 mm 32P source wire centered within the vessel lumen.

Algorithms↗

Well-ionization chamber response relative to NIST air-kerma strength standard for prostate brachytherapy seeds.

The response of well-ionization chambers to the emissions of 103Pd and 125I radioactive seed sources used in prostate cancer brachytherapy has been measured. Calibration factors relating chamber response (current or dial setting) to measured air-kerma strength have been determined for seeds from nine manufacturers, each with different designs. Variations in well-ionization chamber response relative to measured air-kerma strength have been observed because of differences in the emitted energy spectrum due to both the radionuclide support material (125I seeds) and the mass ratio of 103Pd to 102Pd (103Pd seeds). Obtaining accurate results from quality assurance measurements using well-ionization chambers at a therapy clinic requires knowledge of such differences in chamber response as a function of seed design.

Air↗

Choosing the right computer system.

We are living in a world where virtually any information you desire can be acquired in a matter of moments with the click of a mouse. The computer is a ubiquitous fixture in elementary schools, universities, small companies, large companies, and homes. Many dental offices have incorporated computers as an integral part of their management systems. However, the role of the computer is expanding in the dental office as new hardware and software advancements emerge. The growing popularity of digital radiography and photography is making the possibility of a completely digital patient record more desirable. The trend for expanding the role of dental office computer systems is reflected in the increased number of companies that offer computer packages. The purchase of one of these new systems represents a significant commitment on the part of the dentist and staff. Not only do the systems have a substantial price tag, but they require a great deal of time and effort to become fully integrated into the daily office routine. To help the reader gain some clarity on the blur of new hardware and software available, I have enlisted the help of three recognized authorities on the subject of office organization and computer systems. This article is not intended to provide a ranking of features and shortcomings of specific products that are available, but rather to present a process by which the reader might be able to make better choices when selecting or upgrading a computer system.

Appointments and Schedules↗

Report of the ad hoc committee of the AAPM radiation therapy committee on 125I sealed source dosimetry.

PURPOSE: Two developments in 125I-sealed source dosimetry have necessitated swift and accurate implementation of TG43 dosimetry in clinic: (a) the dosimetry constants of 125I endorsed by the AAPM Task Group 43 Report result in calculated dose rate that deviates by as much as 15% from currently accepted dose-rate distributions, and (b) The National Institute of Standards and Technology (NIST) has proposed modifying the 125I air-kerma strength standard by approximately 10%. METHODS AND MATERIALS: The ad hoc committee of AAPM Radiation Therapy Committee describes specific procedures to implement these two developments without causing confusion and mistakes. CONCLUSIONS: Confusion and mistakes may be avoided when the following two general steps are taken: 1) STEP I, TG-43 implementation, and 2) STEP II, new air-kerma strength standard implementation when available from NIST.

Brachytherapy↗

Using technology to market cosmetic dentistry.

The presentation of proposed dental treatment has been hampered by the absence of visual communication technologies. New high tech dentistry-related tools permit efficient production of case presentations for cosmetic dentistry and restorative dentistry. This review describes how to create computer-based case presentations using Microsoft PowerPoint (Microsoft Corp., Redmond, WA) and visual treatment proposals using Microsoft Word for Windows.

Esthetics, Dental↗

EPR dosimetry of cortical bone and tooth enamel irradiated with X and gamma rays: study of energy dependence.

Previous investigators have reported that the radiation-induced EPR signal intensity in compact or cortical bone increases up to a factor of two with decreasing photon energy for a given absorbed dose. If the EPR signal intensity was dependent on energy, it could limit the application of EPR spectrometry and the additive reirradiation method to obtain dose estimates. We have recently shown that errors in the assumptions governing conversion of measured exposure to absorbed dose can lead to similar "apparent" energy-dependence results. We hypothesized that these previous results were due to errors in the estimated dose in bone, rather than the effects of energy dependence per se. To test this hypothesis we studied human adult cortical bone from male and female donors ranging in age from 23 to 95 years, and bovine tooth enamel, using 34 and 138 keV average energy X-ray beams and 137Cs (662 keV) and 60Co (1250 keV) gamma rays. In a femur from a 47-year-old male (subject 1), there was a difference of borderline significance at the alpha = 0.05 level in the mean radiation-induced hydroxyapatite signal intensities as a function of photon energy. No other statistically significant differences in EPR signal intensity as a function of photon energy were observed in this subject, or in the tibia from a 23-year-old male (subject 2) and the femur from a 75-year-old female (subject 3). However, there was a trend toward a decrease (12-15%) in signal intensity at the lowest energy compared with the highest energy in subjects 1 and 3. Further analysis of the data from subject 1 revealed that this trend, which is in the opposite direction of previous reports but is consistent with theory, is statistically significant. There were no effects of energy dependence in the tooth samples.

Adult↗

Exposure-to-absorbed-dose conversion for human adult cortical bone.

The conversion of measured exposure to absorbed dose at a point in bone, under conditions of electron equilibrium, involves a factor (the f-factor) which is proportional to the ratio of the spectrum-averaged photon energy-absorption coefficient for bone to that for air. This paper gives mass energy-absorption coefficients and f-factors for three compositions of human adult compact or cortical bone recommended in publications by the ICRU and the ICRP, for photon energies from 1 keV to 1.5 MeV. Spectrum-averaged f-factors for a number of calibration x-ray beams ranging from 10 to 250 kVp have been calculated and compared to corresponding results obtained with the use of an equivalent photon energy derived from the measured thickness of the half-value layer. At low photon energies (approximately less than 200 keV), the new f-factor results reflect: (a) the rather large differences due to the differing calcium contents among the recommended compositions for bone: and (b) the generally poor predictions obtained when replacing a broad energy spectrum by an equivalent photon energy.

Adult↗