Search PubMedSearch

Biomedical subjects

S M Gehlbach

Publications and source records attributed to S M Gehlbach.

3 recordsLinked to original sources

Instantaneous and continuous cardiac output obtained with a Doppler pulmonary artery catheter.

A newly developed, flow-directed, Doppler pulmonary artery catheter, capable of measuring instantaneous and continuous cardiac output, was evaluated in both an in vitro pump model and an animal model. Quantitative flow was calculated with use of the instantaneous, space-average velocity (obtained from the velocity profile) and the instantaneous area (obtained from the vessel diameter) and compared with electromagnetic flow. Additionally, simultaneous thermodilution flow measurements were obtained. Doppler catheter-determined flow was highly predictive of electromagnetic flow in both continuous and pulsatile pump models (r2 = 0.98, slope or m = 1.04, SEE = 0.44; and r2 = 0.97, m = 1.04 and SEE = 0.33, respectively). Thermodilution was less predictive and appeared to underestimate electromagnetic flow in both the continuous and the pulsatile model (r2 = 0.99, m = 0.91, SEE = 0.20 and r2 = 0.95, m = 0.84 and SEE = 0.34, respectively). In the animal model, Doppler catheter-determined cardiac output appeared to modestly underestimate electromagnetic flow (r2 = 0.80, m = 0.87, SEE = 0.61). However, Doppler determinations of flow remained more accurate than did simultaneous thermodilution measurements (r2 = 0.73, m = 0.79, SEE = 0.72). Accurate, continuous and instantaneous cardiac output measurements appear possible with use of a flow-directed, Doppler pulmonary artery catheter. This catheter system also provides instantaneous diameter measurements and mapping of instantaneous velocity profiles within the main pulmonary artery and may lead to more accurate Doppler-derived assessment of cardiac output in humans.

Animals

Frequency diversity speckle processing.

Ultrasonic waveform data from a tissue-mimicking phantom containing low contrast targets was digitized, stored and processed prior to creating and displaying ultrasonic images. Speckle reduction was performed by digital filtering of the waveform data with appropriately spaced and weighted digital filters, prior to both coherent and incoherent image averaging. The resultant images showed increased signal-to-target boundaries was noted in the processed, compared to unprocessed, images. Incoherent and coherent processing were investigated, and appeared to be equivalent.

Humans

Scatterer-induced frequency variations in reflected acoustic pulses: implications for tissue characterization.

A Hilbert transform approach to the detection of the instantaneous center frequency of reflected ultrasonic pulses was performed for simulated reflected ultrasonic pulses, and digitized ultrasonic waveforms from tissue phantoms. Considerable center frequency modulation was observed for both simulated and recorded ultrasonic waveforms. This phenomenon of frequency modulation can be explained with the aid of a phasor model, in which variations in instantaneous frequency results from the interaction of a multitude of overlapping ultrasonic pulses arising from different scattering centers in tissue. The observed frequency modulation of ultrasonic signals has important implications for tissue characterization techniques, including the measurement of attenuation by the determination of the shift in ultrasonic center frequency.

Mathematics