Search PubMed⌕ Search

Biomedical subjects

S Lundin

Publications and source records attributed to S Lundin.

At least 19 recordsLinked to original sources

Microsatellite instability did not predict individual survival of unselected patients with colorectal cancer.

INTRODUCTION: High microsatellite instability (MSI-H) occurs in about 15% of colorectal cancers (CRC) and clinical as well as pathological features differ from tumours exhibiting low microsatellite instability (MSI-L) or microsatellite stability (MSS). Conflicting data exists about the relevance of MSI in predicting the prognosis and benefit of 5-fluorouracil (5-FU) based chemotherapy in patients with CRC. We investigated the usefulness of MSI as a predictor of distinct clinical attributes influencing recurrence rate and disease-free survival (DFS) subject to the use of adjuvant or palliative chemotherapy with 5-FU in stage II- stage IV CRC. METHODS: We collected data and tumours of 416 consecutive stage I to IV CRC patients from 2000 to 2002, and followed them for a median time of 33 months. Microsatellite loci recommended by the National Cancer Institute were analysed. Cox proportional hazard modelling was used to compare clinical data and survival as well as associations for MSI and 5-FU treatment status of patients with MSI-H, MSI-L or MSS CRC. RESULTS: We identified 52 MSI-H (13%), 21 MSI-L (5%) and 343 MSS (82%) tumours. CRC with MSI-H tended to have a decreased likelihood of metastasising to regional lymph nodes (p=0.055), whilst age of diagnosis and tumour location did not differ. In an analysis that did not take into account the use of chemotherapy, univariate and multivariate analyses failed to show a difference between MSI-H and MSS groups with respect to disease-free and overall survival. Furthermore, survival under application of 5-FU did not correlate with MSI status. CONCLUSION: No clear influence of MSI status on overall survival and response to 5-FU chemotherapy was found.

Aged↗

[Adjuvant and palliative chemotherapy of colorectal cancer in Germany outside controlled trials].

BACKGROUND AND OBJECTIVE: Colorectal cancer is the second most common malignant tumour in Germany with an unfavorable prognosis especially in a locally advanced or metastasizing stage. Although adjuvant and palliative chemotherapy significantly improve 5-year survival, consensus recommendations have in the past been inadequately transformed into clinical practice. It was the aim of this study to analyse the implementation of existing guidelines in a cohort from a defined area of Germany. PATIENTS AND METHODS: In a multicentre study done between January 2000 and January 2002, tumour stage, primary care, adjuvant or palliative chemotherapy and follow-up of 444 patients (216 males, 228 females) with newly diagnosed colorectal cancer were recorded. RESULTS: 301 patients had colonic and 143 patients rectal cancer. The median age at diagnosis was 65 11.3 years. 36 of 96 (38%) patients with stage II colon cancer and 66 of 87 (76%) with stage III disease received adjuvant chemotherapy. 8 of 51 (16%) patients with rectal cancer stage II and 22 of 38 (58%) patients with stage III underwent adjuvant radio- and chemotherapy. The 68 of 84 (81%) patients with stage IV CRC who received palliative chemotherapy were given almost exclusively 5-FU monotherapy. Initial or sequential combination chemotherapy with oxaliplatin or irinotecan were performed in only 24 of 84 (29%) patients. CONCLUSIONS: Stage III colon cancer was predominantly treated according to the existing standard guidelines. In contrast combined radio- and chemotherapy for rectal cancer stage II and III was only performed in one third of the patients, another third receiving neither adjuvant radiation nor chemotherapy. Initial combined or sequential combined chemotherapy for metastasizing colorectal cancer was rarely performed.

Adult↗

Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery.

BACKGROUND: Morbidly obese patients have an increased risk for peri-operative lung complications and develop a decrease in functional residual capacity (FRC). Electric impedance tomography (EIT) can be used for continuous, fast-response measurement of lung volume changes. This method was used to optimize positive end-expiratory pressure (PEEP) to maintain FRC. METHODS: Fifteen patients with a body mass index of 49 +/- 8 kg/m(2) were studied during anaesthesia for laparoscopic gastric bypass surgery. Before induction, 16 electrodes were placed around the thorax to monitor ventilation-induced impedance changes. Calibration of the electric impedance tomograph against lung volume changes was made by increasing the tidal volume in steps of 200 ml. PEEP was titrated stepwise to maintain a horizontal baseline of the EIT curve, corresponding to a stable FRC. Absolute FRC was measured with a nitrogen wash-out/wash-in technique. Cardiac output was measured with an oesophageal Doppler method. Volume expanders, 1 +/- 0.5 l, were given to prevent PEEP-induced haemodynamic impairment. RESULTS: Impedance changes closely followed tidal volume changes (R(2) > 0.95). The optimal PEEP level was 15 +/- 1 cmH(2)O, and FRC at this PEEP level was 1706 +/- 447 ml before and 2210 +/- 540 ml after surgery (P < 0.01). The cardiac index increased significantly from 2.6 +/- 0.5 before to 3.1 +/- 0.8 l/min/m(2) after surgery, and the alveolar dead space decreased. P(a)O2/F(i)O2, shunt and compliance remained unchanged. CONCLUSION: EIT enables rapid assessment of lung volume changes in morbidly obese patients, and optimization of PEEP. High PEEP levels need to be used to maintain a normal FRC and to minimize shunt. Volume loading prevents circulatory depression in spite of a high PEEP level.

Adult↗

Soil-to-plant halogens transfer studies 1. Root uptake of radioiodine by plants.

Long-term controlled experiments under natural conditions in the field have been carried out in the Chernobyl Exclusion zone in order to determine the parameters governing radioiodine transfer to plants from four types of soils (podzoluvisol, greyzem and typical and meadow chernozem) homogeneously contaminated in the 20-cm upper layer with an addition of (125)I. An absence of (125)I depletion in arable soil layers due to volatilization was noted up to one year after contamination. During one year, depletion due to the vertical migration of radioiodine from the arable layer of each of the soils did not exceed 4% of the total (125)I content. Radioiodine concentration ratios (CR) were obtained in radish roots, lettuce leaves, bean pods, and wheat grain and straw. The highest CR values were observed in podzoluvisol: 0.01-0.03 for radish roots and lettuce leaves, 0.003-0.004 for bean pods and 0.001 for wheat grains. In the other three soils, these values were one order of magnitude lower. The parameters relating to changes in radioiodine bioavailability were determined, based on the contamination dynamics of plants in field conditions.

Biological Availability↗

Soil-to-plant halogens transfer studies 2. Root uptake of radiochlorine by plants.

Long-term field experiments have been carried out in the Chernobyl exclusion zone in order to determine the parameters governing radiochlorine (36Cl) transfer to plants from four types of soil, namely, podzoluvisol, greyzem, and typical and meadow chernozem. Radiochlorine concentration ratios (CR) in radish roots (15+/-10), lettuce leaves (30+/-15), bean pods (15+/-11) and wheat seed (23+/-11) and straw (210+/-110) for fresh weight of plants were obtained. These values correlate well with stable chlorine values for the same plants. One year after injection, 36Cl reached a quasi-equilibrium with stable chlorine in the agricultural soils and its behavior in the soil-plant system mimicked the behavior of stable chlorine (this behavior was determined by soil moisture transport in the investigated soils). In the absence of intensive vertical migration, more than half of 36Cl activity in arable layer of soil passes into the radish, lettuce and the aboveground parts of wheat during a single vegetation period.

Chernobyl Nuclear Accident↗

Oral tolerization with peptide 336-351 linked to cholera toxin B subunit in preventing relapses of uveitis in Behcet's disease.

Behcet's disease (BD) specific peptide (p336-351) was identified within the human 60 kD heat shock protein (HSP60). Oral p336-351 induced uveitis in rats which was prevented by oral tolerization with the peptide linked to recombinant cholera toxin B subunit (CTB). This strategy was adopted in a phase I/II clinical trial by oral administration of p336-351-CTB, 3 times weekly, followed by gradual withdrawal of all immunosuppressive drugs used to control the disease in 8 patients with BD. The patients were monitored by clinical and ophthalmological examination, as well as extensive immunological investigations. Oral administration of p336-351-CTB had no adverse effect and withdrawal of the immunosuppressive drugs showed no relapse of uveitis in 5 of 8 patients or 5 of 6 selected patients who were free of disease activity prior to initiating the tolerization regimen. After tolerization was discontinued, 3 of 5 patients remained free of relapsing uveitis for 10-18 months after cessation of all treatment. Control of uveitis and extra-ocular manifestations of BD was associated with a lack of peptide-specific CD4+ T cell proliferation, a decrease in expression of TH1 type cells (CCR5, CXCR3), IFN-gamma and TNF-alpha production, CCR7+ T cells and costimulatory molecules (CD40 and CD28), as compared with an increase in these parameters in patients in whom uveitis had relapsed. The efficacy of oral peptide-CTB tolerization will need to be confirmed in a phase III trial, but this novel strategy in humans might be applicable generally to autoimmune diseases in which specific antigens have been identified.

Adjuvants, Immunologic↗

Increased frequency of activated T-cells in the Helicobacter pylori-infected antrum and duodenum.

Helicobacter pylori colonize the human stomach and duodenum. The infection has been shown to induce a strong T-cell response in the stomach, whereas the response within the duodenum has been poorly characterized. Furthermore, it remains to be elucidated whether the T-cell response may contribute to ulcer formation in the host. In this study, the frequency of different T-cell subsets, their degree of activation and expression of co-stimulatory receptors in biopsies from the duodenum as well as the antrum were studied by immunohistochemistry and flow cytometry. It was also evaluated whether there are differences in the T-cell responses between duodenal ulcer patients and asymptomatic carriers that might explain why only 10-15% of the infected subjects develop duodenal ulcers. The frequencies of CD4+, CD8+ and CD45RO+, i.e. memory T-cells, were significantly increased in the antrum, and the number of CD25+ cells was considerably higher in both the antrum and duodenum of duodenal ulcer patients and asymptomatic carriers as compared to uninfected individuals. Interestingly, the levels of immunosuppressive CTLA-4+ cells were significantly higher in the duodenum of duodenal ulcer patients, as compared to the asymptomatic carriers. H. pylori cause activation of T-cells in the duodenum as well as in the stomach. Our observation of higher levels of CTLA-4+ cells in the duodenum of duodenal ulcer patients than in the asymptomatic carriers suggests that a suppressive T-cell response may be related to the development of duodenal ulcers.

Adult↗

Alveolar pressure monitoring: an evaluation in a lung model and in patients with acute lung injury.

OBJECTIVES: We evaluated an algorithm for continuous on-line monitoring of alveolar pressure over time in a lung model with lower and upper inflection points and variable resistance ratios and in patients with acute lung injury. The algorithm is based on "static" pressure/volume curves obtained from tracheal pressure measurements under dynamic conditions. DESIGN AND SETTING: Experimental and clinical evaluation of algorithm in a university hospital laboratory and intensive care unit. PATIENTS: Ten patients undergoing postoperative respiratory therapy (feasibility of tracheal measurement) and ten patients with acute lung injury undergoing ventilator treatment (evaluation of algorithm). MEASUREMENTS AND RESULTS: Direct tracheal pressure measurements with a catheter inserted through the endotracheal tube. Comparison of measured alveolar and the dynostatic alveolar pressure vs. time in a lung model with changes in five ventilatory parameters. Examples of clinical monitoring are reported. In the model there was excellent agreement between alveolar pressures obtained by the algorithm, the dynostatic alveolar pressure, and measured alveolar pressure at all ventilator settings. For inspiratory/expiratory resistance ratios between 1:2.1-2.1:1, the dynostatic alveolar pressure was within +/-1.5 cm H(2)O of measured alveolar pressure. In patients the technique for direct tracheal pressure measurement using a catheter inserted through the endotracheal tube functioned satisfactorily with intermittent air flushes for cleansing. CONCLUSIONS: Using a thin tracheal pressure catheter inserted through the endotracheal tube alveolar pressure allows continuous bedside monitoring with ease and precision using the dynostatic algorithm. The method is unaffected by tube and connector geometry or by secretions.

Adolescent↗

Attitudes of Swedes to marginal donors and xenotransplantation.

The aim of our survey was to capture the attitudes of Swedes to marginal donors and xenotransplantation. Modern biotechnology makes it possible to replace non-functioning organs, cells, and genes. Nonetheless, people may have reservations and fears about such treatments. With the survey, Attitudes of the General Public to Transplants, we have sought to expose the ambivalence that arises when medical possibilities are juxtaposed with ideas of risk. The design of the questionnaire originates from the interdisciplinary cooperation between ethnologists, medical scientists, and geneticists. By combining qualitative and quantitative methods, it is possible to illustrate the complexity that characterises people's view of modern biomedicine. People's reflections are based on a personal and situation bound morality, which does not necessarily coincide with what they generally consider as ethically justifiable.

Adolescent↗

Dead-space reduction and tracheal pressure measurements using a coaxial inner tube in an endotracheal tube.

OBJECTIVE: To evaluate the effects on CO(2) washout of the coaxial double lumen tube (DLT) as compared to a standard endotracheal tube (ETT) and tracheal gas insufflation (TGI). Precision of tracheal pressure monitoring through the DLT and safety issues, including intrinsic PEEP (PEEPi) formation during DLT ventilation, were also evaluated. DESIGN: Lung model study. SETTING: University research laboratory. MEASUREMENTS AND RESULTS: CO(2) washout was analysed in a lung model by measuring single alveolar CO(2) concentration during DLT ventilation as compared to standard ETT ventilation, at different minute ventilation (6-14 l/min) and different CO(2)-output levels (180 ml/min, 240 ml/min, and 300 ml/min). At a CO(2) output level of 240 ml/min the CO(2) washout was also compared to tidal volume-adjusted continuous TGI and expiratory synchronised TGI. Precision of tracheal pressure monitoring and PEEPi formation during DLT ventilation was evaluated by comparing pressure in each limb above the tube to reference tracheal pressure, varying I:E ratios (1:2, 1:1, and 2:1), tidal volumes (300-700 ml), breathing frequencies (15-25), and compliance (20-50 ml/cmH(2)O). DLT ventilation had the same efficacy in removing CO(2) as continuous and expiratory synchronised TGI, reducing single alveolar CO(2) concentration by 9-21% compared to normal ventilation. Tracheal pressure could be measured through the DLT with high precision. There was only marginal formation of PEEPi at tidal volumes <or=600 ml, I:E ratio <or=1:1, and compliance <or=35 ml/cmH(2)O. CONCLUSIONS: The double lumen tube is as effective as tracheal gas insufflation in reducing CO(2) tension. Tracheal pressure and formation of PEEPi can be monitored with high precision without interrupting ventilation.

Calibration↗

Monitoring functional residual capacity (FRC) by quantifying oxygen/carbon dioxide fluxes during a short apnea.

BACKGROUND: Clinically applicable methods for measuring FRC are currently lacking. This study presents a new method for FRC monitoring based on quantification of metabolic gas fluxes of O2 and CO2 during a short apnea. METHODS: Base line exchange of oxygen and carbon dioxide was measured with indirect calorimetry. End-tidal ( approximately alveolar) O2 and CO2 concentrations were measured before and after a short apnea, 8-12 s, and FRC was calculated according to standard washin/washout formulas taking into account the increased solubility of CO2 in blood when the tension is increased during the apnea. The method was tested in a lung model with CO2 excretion and O2 consumption achieved by combustion of hydrogen and implemented in six ventilator-treated patients with acute respiratory failure (ARF). RESULTS: In the lung model the method showed excellent correlation (r = 0.98) with minimal bias (34 ml) and a good precision, limits of agreement being 160 and -230 ml, respectively, compared to the reference method. In six ARF patients changes in FRC induced by increase or decrease in PEEP and measured with the O2/CO2 flux FRC method corresponded well with changes in reference values of FRC (r = 0.76-0.94). CONCLUSIONS: A new method has been proposed in which FRC could be monitored from measurements of physiological fluxes of gases during a short apnea with the use of standard ICU equipment and some calculations. We anticipate that with further development, this technique could provide a new tool for monitoring respiratory changes and ventilator management in the ICU.

Adult↗

Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients.

BACKGROUND: Monitoring central hemodynamics is essential in critically ill patients and less invasive techniques are needed. In this study, the clinical and technical performance of a new non-invasive cardiac output monitor (NICO) based on partial CO2 rebreathing technique and a modified Fick equation were evaluated. The various sources of possible errors in measurement of cardiac output (CO), carbon dioxide production (VCO2) and pulmonary shunt were also assessed. METHODS: Simultaneous measurements of CO with partial CO2 rebreathing technique (CO(nico)) and thermodilution (CO(td)) were performed in 15 patients during major surgery or in the ICU. Pulmonary shunt was estimated from this device and compared to values obtained by standard shunt formula. The accuracy of VCO2 measurements was assessed in a mechanical lung model. RESULTS: A good correlation was found between CO(nico) and CO(td) (r = 0.96, within-subject correlation r = 0.88) with a small underestimation of cardiac output by the NICO of 0.04 L/min, limits of agreement (+/- 2 SD) being - 1.68 and 1.76 L/min. In hemodynamic unstable patients the method closely tracked changes in CO. Pulmonary shunt was underestimated by approximately 11%-units compared to standard shunt calculations using arterial and mixed venous blood gases. We also observed an underestimation in VCO2 measurements. CONCLUSION: Clinical evaluation shows that partial CO2 rebreathing technique provides a useful and accurate non-invasive estimate of cardiac output. Although this technique cannot fully replace the pulmonary artery catheter, it may be used to monitor central hemodynamics in a large number of critically ill patients.

Adult↗

[Organ transplantation, ethics and culture in Japan. Japanese citizens may choose between cardiac death and brain death].

The first heart transplantation in Japan was performed in 1968. However, the surgeon was prosecuted, and transplantations from cadaveric donors came to an end. A new law in 1997 offered the possibility to choose how one would be pronounced dead, and if one chose to be declared dead according to brain related criteria, then one could become a cadaveric donor, if certain conditions were fulfilled. The first donations and transplantations took place in 1999. The Japanese public has been reluctant to accept the concept of brain death. The integrity of the dead body seems to command greater respect in Japan than in Sweden, and there is a reluctance to treat body parts as exchangeable. At the same time many Japanese travel abroad to obtain organs. The act of 1997 is a very interesting way of trying to integrate a new technology in Japanese culture, and the process of obtaining informed consent from relatives relies on traditional cultural roles.

Brain Death↗

"Tolerosomes" are produced by intestinal epithelial cells.

The development of immunological tolerance to orally fed antigens depends on the sampling, processing and transportation events followed in the intestinal epithelium. We present here a description of a "tolerosome": a supra-molecular, exosome-like structure assembled in and released from the small intestinal epithelial cell. The tolerosome is a approximately 40 nm large vesicular structure that carries MHC class II (MHC II) with bound antigenic peptides sampled from the gut lumen. Tolerosomes isolated from serum shortly after antigen feeding or from an in vitro pulsed intestinal epithelial cell line are fully capable of inducing antigen specific tolerance in naive recipient animals. Purified tolerosomes represent a structure by which fed antigens can be efficiently presented to the immune system. Removal of the tolerosomes from serum by ultracentrifugation or absorption of MHC II results in abrogated tolerance development.

Animals↗

Continuous on-line measurements of respiratory system, lung and chest wall mechanics during mechanic ventilation.

OBJECTIVE: We present a concept of on-line, manoeuvre-free monitoring of respiratory mechanics during dynamic conditions, displaying calculated alveolar pressure/volume curves continuously and separating lung and chest wall mechanics. DESIGN: Prospective observational study. SETTING: Intensive care unit of a university hospital. PATIENTS: Ten ventilator-treated patients with acute lung injury. INTERVENTIONS: Different positive end-expiratory pressure (PEEP) and tidal volumes, low flow inflation. MEASUREMENTS AND RESULTS: Previously validated methods were used to present a single-value dynostatic compliance for the whole breath and a dynostatic volume-dependent initial, middle and final compliance within the breath. A high individual variation of respiratory mechanics was observed. Reproducibility of repeated measurements was satisfactory (coefficients of variations for dynostatic volume-dependent compliance: < or =9.2% for total respiratory system, < or =18% for lung). Volume-dependent compliance showed a statistically significant pattern of successively decreasing compliance from the initial segment through the middle and final parts within each breath at all respiratory settings. This pattern became more prominent with increasing PEEP and tidal volume, indicating a greater distension of alveoli. No lower inflection point (LIP) was seen in patients with respiratory rate 20/min and PEEP at 4 cmH2O. A trial with low flow inflation in four of the patients showed formation of a LIP in three of them and an upper inflection in one. CONCLUSIONS: The monitoring concept revealed a constant pattern of successively decreasing compliance within each breath, which became more prominent with increasing PEEP and tidal volume. The monitoring concept offers a simple and reliable method of monitoring respiratory mechanics during ongoing ventilator treatment.

Adult↗

Warning! Suctioning. A lung model evaluation of closed suctioning systems.

BACKGROUND: Closed system suctioning, CSS, has been advocated to avoid alveolar collapse. However, ventilator manufacturers indicate that extreme negative pressure levels can be obtained during closed system suctioning, impeding the performance of the ventilator. METHODS: Suctioning with a 12 or 14 Fr catheter with a vacuum level of -50 kPa was either performed with an open technology or a CSS, where the catheter is introduced through a tight-fitting connection through the endotracheal tube, EYT. The lung model was ventilated with a Servo 900C or 300 ventilator with an I:E ratio of 1:2, 1:1 and 2:1 and extrinsic positive end-expiratory pressure (PEEP) at 0 or 10 cm H20. Respiratory volumes and alveolar pressure were measured at the lung model alveolus. RESULTS: The initial suctioning flow was >40 l/min with a 14 Fr catheter. When inserting the catheter through a no. 7 ETT, PEEP rose from 11 to 23 cm H2O during volume control ventilation with an I:E ratio 1:1. During suctioning the alveolar pressure fell to 10 cm H2O below the set PEEP level. CSS during pressure control ventilation had fewer effects. Low tidal volumes, inverse I:E ratio and secretions in the tube resulted in pressures down to -92 cm H2O. CONCLUSION: CSS should not be used in volume control ventilation due to risk of high intrinsic PEEP levels at insertion of the catheter and extreme negative pressures during suctioning. Pressure control ventilation produces less intrinsic PEEP effect. The continuous positive airway pressure (CPAP) mode offers the least intrinsic PEEP during insertion of the catheter and least sub-atmospheric pressure during suctioning.

Air Pressure↗